SDR 2008UALA00453Structure · damagedR-2 DOOR UPPER HINGE ARM CUTOUT IS DAMAGED. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00452Frame · dentedFWD PIT AT STA 600, STR 24L FRAME IS DENTED ON INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00434Strap · unsecureDOOR 2L WOULD NOT ARM. FOUND RETAINER STRAP INTERFERENCE. SECURED RETAINER STRAP, DOOR FUNCTIONS NORMALLY.
SDR 2008UALA00433Slide · disengagedSLIDE AT DOOR 1R IS DISENGAGED FROM DOOR. REINSTALLED SLIDE.SDR 2008UALA00401Wire · burnedF/A REPORTED HOT ODOR IN AREA OF AFT GALLEY SHORTLY AFTER TAKEOFF. FOUND COFFEE MAKER HEATER SHORTED WITH WIRES BURNED. REPAIRED WIRING, REPLACED HEATER, COFFEE MAKER OPS CHECKED NORMAL. NO REPEATS.SDR 2008UALA00400Lanyard · brokenLEFT OVERWING SLIDE SAFETY PIN STRING BROKEN. THIS PIN KEEPS SLIDE FROM UNRAVELING. REMOVED AND REPLACED LT OVERWING SLIDE.SDR 2008UALA00399Support · crackedRIGHT O/B FLAP I/B TRACK FWD LWR JACKSCREW SUPPORT CRACKED. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00398Support · crackedLEFT O/B FLAP I/B SIDE TRACK, FWD LWR JACK SCREW SUPPORT CRACKED. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00397Frame · dentedAFT PIT AT STA 1500, APPROX AT STR 26L FRAME DENTED ON INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00396Frame · dentedAFT PIT FRAME HAS 2 EACH DENTS ON INBOARD FLANGE BETWEEN STR 25L AND 26L AT STA 1400. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00395Frame · dentedAFT PIT AT STA 1600, APPROX STR 26L, FRAME DENTED ON INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00394Frame · dentedAFT PIT FRAME DENTED JUST OUTBOARD OF STR 26L AT STA 1440, INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00393Frame · dentedAFT PIT AT STA 1540, APPROX AT STR 26L, FRAME DENTED ON INBOARD FLANGE. ACCOMPLISHED MAJOR REPAIR AT GSO.SDR 2008UALA00406Battery Pack · dischargedEMERGENCY AISLE LIGHTS AT SEAT'S 15A AND 18A INOP. REPLACED BATTERY PACK.SDR 2008UALA00407Battery · faultyFLASHLIGHT DOOR 2L INOPERATIVE. FOUND FAULTY BATTERY. REPLACED ENTIRE FLASHLIGHT ASSY, OPS CHECKED NORMAL.SDR 2008UALA00362Girt Bar · obstructed1R WILL NOT ARM. DEBRIS UNDER GIRT BAR FITTINGS. CLEANED DEBRIS FROM GIRT BAR AREA ON FLOOR. DOOR ARMS AND DISARMS NORMALLY.SDR 2008UALA00328Fuse · blownL-1 AND R-1 EXTERIOR EMERGENCY LIGHTS INOPERATIVE. REPLACED FUSE.SDR 2008UALA00331Frame · dentedAFT PIT AT STA 1440 STR 26L, FRAME HAS DENT. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00330Support Fitting · crackedRIGHT WING OUTBOARD FLAP FAIRING, SUPPORT FITTING CRACKED, LOCATED INBOARD OF AILERON. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00329Doubler · dentedLEFT FUSELAGE REPAIR DOUBLER HAS DENT BETWEEN FRAMES 600 AND 620LT, AND STRINGERS 17L AND 16L. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00334Light · inoperativeSEVERAL EEL AISLE LIGHTS ARE INOP THROUGHOUT THE CABIN. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00333Feeder Cable · defectiveEEL LIGHTS FROM ROWS 32-34 ARE INOPERATIVE. REPLACED FEEDER.SDR 2008UALA00327Light · looseEMERGENCY FLOOR LIGHTING LOOSE NEAR 12C. RESECURED LIGHTING.SDR 2008UALA00332Panel · shortedEVACUATION COMMAND - SIGNAL IN COCKPIT OVERHEAD PNL HAS DARK AREAS. ELECTRICAL SHORTING ON PANEL ITSELF. REPLACED COCKPIT EVAC PANEL, NORMAL OPERATION.SDR 2008UALA00337Light · inoperativeEMERGENCY LIGHT AT SEAT 29 ABC ON BULLNOSE BIN PNL IS INOP. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00336Light · inoperativeLEFT FWD EXT EMERGENCY SLIDE LIGHT INOP. RELAMPED EMERGENCY LIGHT.SDR 2008UALA00301Unknown · smokeFLIGHT CREW REPORTS SMOKE IN COCKPIT. UNABLE TO DUPLICATE ON GROUND. PERFORMED TEST OF RT AND LT RECIRCULATION FANS, OPS CHECKED EQUIPMENT COOLING FANS, RAN APU WITH AI ON, TRIED DIFFERENT CROSSBLEED CONFIGS, NO ODOR EVER NOTED. THIS ISSUE NEVER APPEARED ASDR 2008UALA00265Control Rod · out of adjustMAIN CABIN DOOR 3L VERY DIFFICULT TO DISARM. DOOR CONTROL ROD OUT OF ADJUSTMENT. ADJUSTED RETRACTABLE DOOR MECH CONTROL ROD. ACCOMPLISHED DOOR OPS CHECK, OPS CHECKED NORMAL.SDR 2008UALA00203Processing Unit · faultyFLIGHT DIVERTED DUE TO A FUEL QUANTITY PROBLEM. FUEL QTY PROCESSOR UNIT FAULTY. REPLACED THE FQPU, ALL SYSTEMS CHECKED NORMALLY.SDR 2008UALA00268Lamp · inoperativeRIGHT FWD OVERWING ESCAPE HATCH LIGHT IS INOPERATIVE. RELAMPED.SDR 2008UALA00261Frame · dentedAFT PIT AT STA 1400 BETWEEN STR 25L AND STR 26L, FRAME HAS DENT 3 PLACES. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00260Structure · damagedL2 DOOR UPPER HINGE ARM ASSY CUTOUT HAS DAMAGE. MAJOR REPAIR ACCOMPLISHED.SDR 2008UALA00284Idg · lowRIGHT GEN DRIVE LIGHT IS OUT WITH ENGINE SHUTDOWN. POSSIBLY A LOW OIL CONDITION (OVERHEAT). SERVICED IDG AND ACCOMPLISHED TEST RUN OF RIGHT IDG, NO LEAKS NOTED AND IDG WAS INDICATING NORMAL. NO REPEATS.SDR 2008UALA00231Lamp · inoperativeDOOR 2L EXTERIOR EMERGENCY LIGHT INOP. RELAMPED.SDR 2008UALA00230Stringer · damagedLIGHTNING STRIKE AT STA 445, STRINGER 7L, IS BEYOND ALLOWABLE LIMITS. ACCOMPLISHED MAJOR REPAIR.
SDR 2008UALA00216Hinge · damagedR2 DOOR UPPER HINGE ARM ASSY CUTOUT REQUIRES DOUBLER INSTALLATION. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00215Frame · damagedFUSELAGE FRAME AT BS 1420 STR 26L HAS DAMAGE. ACCOMPLISHED MAJOR REPAIR.
SDR 2008UALA00186Stringer · corrodedAFT CARGO FLOOR STRINGER CORRODED AT STA 1358-1362 RBL 7. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00184Skin · dentedL2 DOOR EXTERNAL SKIN HAS 2 DENTS ABOVE LOWER GATE. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00183Intercostal · corrodedSURFACE CORROSION ON INTERCOSTAL AT BS 1600-1612 BL 0 WL 138 TO WL 142. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00181Skin · dentedR1 DOOR EXTERNAL SKIN HAS A DENT BY LOWER HINGE ARM CUTOUT. ACCOMPLISHED MAJOR REPAIR.SDR 2008UALA00173Light · inoperativeEMERGENCY ESCAPE PATH LIGHT AFT LAV DOOR THRESHOLD IS INOP. ACCOMPLISHED REPAIR OF ESCAPE LIGHT PATH LIGHTING.SDR 2008UALA00171Actuator · leakingDISPATCH REPORTS LOSS OF LEFT GEN INFLIGHT. APU GEN ONLINE. RECURRED ON FLT 116-16JAN FOUND FUEL LEAK FROM NR 1 2.5 BLD ACT. REPLACED LT IDG, NR 1 ENG FUEL/OIL COOLER AND 2.5 BLEED ACTUATOR.SDR 2008UALA00170Battery · inoperativeEMERGENCY FLASHLIGHT AT DOOR 2 LEFT DOESN'T FLASH. FOUND BATTERY FAILED.
REPLACED BATTERY, OPS CHECKED OK.SDR 2008UALA00160Light · unsecureEEL AT 13C NOT SECURED TO FLOOR. SECURED EEL TRACK TO FLOOR.SDR 2008UALA00159Battery · weakEMERGENCY EEL STRIP LIGHT IS NOT WORKING FROM ROWS 16-23. FOUND BATTERY CHARGE WEAK. RECHARGED FOR 30 MIN, OPS CHECKED OK. NO REPEATS.SDR 2008UALA00151Floorbeam · corrodedFLOORBEAM UPPER CAP CORRODED AT BS 1640 BL 8L TO 57R WL 208. PERFORMED MAJOR REPAIR.SDR 2008UALA00150Door Frame · damagedL-2 DOOR UPPER HINGE ARM CUTOUT REQUIRES DOUBLER INSTALLATION, FRAME DAMAGE PREVIOUSLY ROUTED OUT. MAJOR REPAIR ACCOMPLISHED.SDR 2008UALA00149Door Frame · damagedR-2 DOOR UPPER HINGE ARM CUTOUT REQUIRES A REPAIR DOUBLER, FRAME DAMAGE PREVIOUSLY ROUTED OUT. MAJOR REPAIR ACCOMPLISHED.SDR 2008UALA00148Frame · dentedAFT PIT AT BS 1480 BETWEEN STR 25L & STR 26L, FRAME HAS DENT IN 2 PLACES. ACCOMPLISHED MAJOR REPAIR.