Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA01858Skin · corrodedAFT PIT LOWER SKIN ANTENNA CUTOUT CORRODED AT STA 1430 LBL 2. MAJOR REPAIR ACCOMPLISHED: REMOVED ANTENNA DOUBLER TO FACILITATE CORROSION REMOVAL. FABRICATED & INSTALLED A NEW -31 DOUBLER.SDR 2007UALA01872Proximity Switch · inoperativeSLIDE ARMED LIGHT AT DOOR 2L IS DIM. [08-07-07] REPLACED MAIN LANDING GEAR DOOR WARNING MAGNETIC PROXIMITY SWITCH ASSY.SDR 2007UALA01845Light · inoperativeEEL STRIP AT ROW 15ABC INOPERATIVE. [06-22-07] REPLACED 15 ABC EEL STRIP. OPS CHECK OK.SDR 2007UALA01844Light · inoperativeEMERGENCY EXIT LIGHT AT 25ABC IS INOPERATIVE. REPLACED LAMP.SDR 2007UALA01843Sign · inoperativeCEILING EMERGENCY EXIT SIGN AT OVERWING DOORS IN INOP. [06-22-07] REPLACED BATTERY.SDR 2007UALA01842Strip · tornEXIT PATH LIGHTING STRIP IS TORN AND A TRIPPING HAZARD AT 13ABC & 29ABC. [06-22-07] SECURED COVERS. LIGHTS OP NORMAL.SDR 2007UALA01841Charger · malfunctionedNR 2 LEFT MED EMERGENCY LIGHT SIGN INOPERATIVE. [06-22-07] REPLACED CHARGER.SDR 2007UALA01822Bottle · lowLOW BOTTLE PRESSURE. REPLACED SLIDE.SDR 2007UALA01832Rivet · meltedSECTION 41, STATION 399.5 HAS 6 MELTED RIVETS. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE & INSTALLED DOUBLER REPAIR.SDR 2007UALA01809Light · inoperativeEXTERIOR EMERGENCY EXIT LIGHT OUT AT DOOR 2L. [06-22-07] RELAMPED.SDR 2007UALA01808Light · inoperativeFLOOR MOUNTED ESCAPE PATH LIGHT STRIP INOP AT MID LAV. [06-22-07] RECONNECTED LAMP TO FWD POWER CABLE.SDR 2007UALA01807Light · inoperativeEXT EMERGENCY EXIT LIGHT INOP DOOR 4R. RELAMPED EMERGENCY LIGHT.SDR 2007UALA01802Harness · tornDOOR L2 ESCAPE SLIDE HARNESS AT LATCH YOKE IS TORN, PEELING. [08-07-07] INSTALLED NEW HARNESS.SDR 2007UALA01806Light · inoperativeF/O AISLE LIGHT INOPERATIVE. [06-22-07] RELAMPED OPS CHECK OK.SDR 2007UALA01805Inverter · inoperativeEEL LIGHTS INOP FROM ROW 30 TO AFT GALLEY. REPLACED INVERTER. OP CHECKS OKAY.SDR 2007UALA01786Battery · faultyFOUND EMERGENCY FLASHLIGHT FAULTY. [07-24-07] REPLACED ALL EMERGENCY FLASHLIGHT BATTERIES.SDR 2007UALA01744Generator · failedFLIGHT DIVERTED DUE TO LOSS OF NR 2 GENERATOR. [08-07-07] RT GENERATOR DRIVE DISC LIGHT ILLUMINATED WITH EICAS MSG. REPLACED RIGHT GCU. RESET DRIVE DISC AND SERVICED IDG AS PRECAUTIONARY.SDR 2007UALA01740Light · inoperativeDOOR 2R ARMING LIGHT INOPERATIVE. [06-20-07] REPLACED DOOR 2R PROX SENSOR.SDR 2007UALA01731Structure · crackedNR 2R MED CABIN DOOR UPPER HINGE CUTOUT CRACKED. [06-20-07] MAJOR REPAIR ACCOMPLISHED. REPAIRED 2R MAIN ENTRY CABIN DOOR UPPER HINGE CUT OUT PER UA ENGINEERING SPECIFICATIONS.SDR 2007UALA01735Sill · dirtyDOOR 3R WOULD NOT ARM. [06-20-07] CLEANED DEBRIS FROM DOOR SILL AREA. ATTRIBUTED THIS DISCREPANCY TO IMPROPER SKIRTING UNDERNEATH DOOR AND INADEQUATE CLEANING.SDR 2007UALA01734Slide · faultyL-1 DOOR HARD TO ARM AND DISARM. [06-20-07] REMOVED AND REPLACED SLIDE DUE TO SKIRTING MATERIAL INTERFERING WITH GIRT BAR,SDR 2007UALA01730Oxygen System · leakingCREW O2 PRESSURE APPEARS TO HAVE A SLOW LEAK. STARTED OUT WITH 1640 PSI NOW READS 1600 PSI AFT. [06-20-07] REMOVED BOTTLE AND SVC'D TO 1650PSI. NOTED THAT LEAK WAS EVIDENT AT BOTTLE AFTER CYCLING SHUTOFF VALVE SEVERAL TIMES, NO LEAK NOTED. REPLACED CREW OSDR 2007UALA01727Structure · dentedFWD CARGO DOOR DENTED ON AFT EDGE OF FWD CARGO DOOR APPROX DAMAGE TO MEASURE QUARTER INCH IN DEPTH AND HALF INCH IN LENGTH. MAJOR REPAIR ACCOMPLISHED: INSTALLED EXTERNAL DOUBLER REPAIR.SDR 2007UALA01726Strap · crackedCRACKED FLOORBEAM STABILIZING STRAP AT BS 375, LBL 25. MAJOR REPAIR ACCOMPLISHED: REPAIRED & INSTALLED STRAP.SDR 2007UALA01724Pump · failedRTFL DUE TO LEFT AFT FUEL BOOST PUMP FAILURE. [06-20-07] LT AFT FUEL BOOST PUMP INOP. AFT FUEL BOOST PUMP PRESSURE SWITCH WAS REPLACED.PLAN TO LAND APPROX 10K OVERGROSS ON RETURN FOR FUEL BOOST PUMP FAILURE. ACCOMPLISHED PHASE 1 ACFT INSPECTION AND NO DAMSDR 2007UALA01711Light · looseEMERGENCY STRIP LIGHTING IN FRONT OF 1ST CLASS CABIN LOOSE. RE-SECURED STRIP TO FLOOR.SDR 2007UALA01741Engine · faultyNR 1 ENGINE HIGH OIL CONSUMPTION EXCEEDS LIMIT. [06-20-07] STARTER CARBON SEAL WAS FOUND LEAKING. REPLACED SEAL.SDR 2007UALA01713Feeder Cable · damagedAFT C-ZONE & FWD A-ZONE EEL FEEDERS ARE DAMAGED. REPAIRED EEL FEEDER.SDR 2007UALA01712Light · inoperativeEMERGENCY LIGHT INOP AT ROW 22ABC. RELAMPED EMERGENCY LIGHT.SDR 2007UALA01708Fitting · damagedNR 1 PYLON AT NAC STA 201, INBOARD MID SPAR FITTING, LOWER TANG, FASTENER HOLE ELONGATED. MAJOR REPAIR ACCOMPLISHED: CLEANED UP DAMAGE. FABRICATED & INSTALLED A FREEZE PLUG.SDR 2007UALA01707Fitting · damagedINBOARD SIDE LOAD FITTING, INBOARD FWD HOLE DAMAGED RIGHT WING. MAJOR REPAIR ACCOMPLISHED: REAMED HOLE OVERSIZED. COLD WORKED HOLE & FINAL REAMED FOR OVERSIZED FASTENER INSTALLATION.SDR 2007UALA01706Frame · dentedAFT PIT, LEFT STA 1580, STR 25L AREA, MAIN FRAME DENTED. MAJOR REPAIR ACCOMPLISHED: REMOVED DENT DAMAGE ON FRAME INBOARD FLANGE BETWEEN STR 23L - 24L & BETWEEN 26L-27L. REMOVED EXISTING PRODUCTION SPLICE. FABRICATED & INSTALLED A NEW PRODUCTION SPLICE ANGLSDR 2007UALA01705Frame · dentedAFT PIT, LEFT SIDE STA 1440, STR 25L AREA, MAIN FRAME DENTED. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE ON FRAME INBOARD FLANGE BETWEEN STR 23L - 23L & 25L, REMOVED EXISTING PRODUCTION SPLICE. FABRICATED & INSTALLED A NEW PRODUCTION SPLICE ANGLE. FABRICATESDR 2007UALA01704Frame · dentedAFT PIT, LEFT SIDE STA 1420 BETWEEN STR 24- 25L, MAIN FRAME DENTED. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE & EXISTING PRODUCTION SPLICE. FABRICATED & INSTALLED A NEW PRODUCTION SPLICE ANGLE. FABRICATED & INSTALLED 2 EA -15 STRINGER CLIPS.SDR 2007UALA01703Frame · crushedFWD PIT- LEFT SIDE, STA 600 BETWEEN STR 22- 25L MAIN FRAME CRUSHED (RIB). MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. FABRICATED & INSTALLED A J-ANGLE REPAIR NESTED INSIDE THE FRAME INBOARD FLANGE. FABRICATED & INSTALLED 2 EA -80 STRINGER CLIPS. FABRICATEDSDR 2007UALA01680Frame · bentFWD PIT LEFT SIDE, STA 580, STR 24L - 25L MAIN FRAME BENT (RIB). MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE AND EXISTING PRODUCTION SPLICE AND FABRICATED A REPAIR ANGLE AND INSTALLED. ALSO FABRICATED & INSTALLED 1 EA -80 STRINGER CLIP.SDR 2007UALA01679Frame · dentedAFT PIT, LEFT SIDE, STA 1480 BETWEEN STR 24 - 25L, MAIN FRAME HAS 2 EA DENTS. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE AND FABRICATED A J-REPAIR ANGLE AND INSTALLED NESTED INSIDE THE FRAME INBOARD FLANGE.SDR 2007UALA01678Frame · dentedFWD PIT, LEFT SIDE, STA 680, BETWEEN STR 23 - 24L, MAIN FRAME HAS DENT (RIB). MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE AND FABRICATED A J-REPAIR ANGLE AND INSTALLED TO NEST INSIDE THE FRAME INBOARD FLANGE.SDR 2007UALA01677Frame · dentedAFT PIT, RIGHT SIDE, STA 1580 AT STR 25R AREA, MAIN FRAME DENTED. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE AND FABRICATED A J-ANGLE REPAIR PIECE AND INSTALLED NESTED INSIDE FRAME INBOARD FLANGE.SDR 2007UALA01676Frame · dentedAFT PIT RIGHT SIDE, STA 1560 AT STR 25R, MAIN FRAME DENTED (RIB). MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE AND FABRICATED A J-ANGLE REPAIR PIECE AND INSTALLED NESTED INSIDE FRAME INBOARD FLANGE.SDR 2007UALA01675Frame · dentedFWD PIT, LEFT SIDE, STA 660, BETWEEN STR 24 -25L, MAIN FRAME DENTED (RIB). MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE AND EXISTING PRODUCTION SPLICE. FABRICATED A NEW PRODUCTION SPLICE AND 1 EA -30 STRINGER CLIP.SDR 2007UALA01710Light · inoperativeBOTH FWD & AFT LEFT WING EXTERIOR OVERWING AND ROW 2CD BULLNOSE EXIT EMERGENCY LIGHTS ARE INOPERATIVE. RELAMPED EMERGENCY LIGHTS.SDR 2007UALA01674Frame · dentedAFT PIT, LEFT SIDE, STA 1400, STR 25L AREA, MAIN FRAME HAS DENT. MAJOR REPAIR ACCOMPLISHED: REMOVED EXISTING REPAIR FROM FRAME INBOARD FLANGE AT STR 27L. FABRICATED & INSTALLED A NESTED J-ANGLE REPAIR WHICH IS NESTED INSIDE THE EXISTING CHORD BETWEEN STR 25SDR 2007UALA01673Door Frame · crackedR-2 DOOR, FORWARD FRAME AT UPPER HINGE CUTOUT IS CRACKED. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED A CRES DOUBLER.SDR 2007UALA01689Switch · brokenDOOR 1L EMERGENCY LIGHT TEST SWITCH BROKEN. REPLACED SWITCH.SDR 2007UALA01681Slide · unsecureDOOR SLIDE 1L FELL OUT ON TO AIR STAIR DUE TO NOT BEING DISARMED. [06-20-07] REMOVED AND REPLACED DOOR 1 LT SLIDE AND EMERGENCY POWER RESERVOIR.SDR 2007UALA01649Acm · inoperativeFLIGHT DIVERTED AFTER THE CABIN WOULD NOT PRESSURIZE. [08-07-07] FOUND ACM NOT RUNNING. ACCOMPLISHED SERVICE TIP AND OP CHECKED OK.SDR 2007UALA01688Target · dirtyLEFT AFT ENTRY DOOR EICAS ON GROUND TAXIING IN. INDICATIONS NORMAL AT GATE. *S/D* CLEANED DEBRIS FROM PROXIMITY TARGET PLATE AND GROUND PROX SENSOR. NO COMPONENTS REPLACED.SDR 2007UALA01690Oven · sparksFIRST CLASS OVEN NR 107 ELECTRICAL SPARKS FROM BEHIND. TURNED OFF, NO MORE SPARKS. [06-20-07] NO DAMAGE TO AC WIRING NOTED, FOUND GUIDE PIN PUSHED INTO OVEN. REPLACED CONVECTION OVEN,SDR 2007UALA01685Rivet · damagedRIVET DAMAGED BY LIGHTNING STRIKE STA 720 WL 160 ON LEFT SIDE OF FUSELAGE. REMOVED 1EA BLIND FASTENER, STEPPED UP HOLES AS REQUIRED, HFEC REVEALED NO CRACKS. INSTALLED SOLID FASTENER.
Back to Boeing 757-222