Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2004UALA01145Tear Strap · corrodedAFT PIT TEAR STRAP EXFOLIATED FWD AND AFT SIDE OF STA 1400 BETWEEN STR 27L AND 28L. SPLICE STRAP REPLACED.SDR 2004UALA01144Frame · dentedAFT PIT STA 1420 FRAME DENTED AT STR 25L. DENT CUTOUT AND J ANGLE REPAIR INSTALLED.SDR 2004UALA01143Frame · dentedAFT PIT STA 1580 FRAME DENTED AT STR 25R. DAMAGED WAS CUTOUT AND FRAME J ANGLE REPAIR WAS ACCOMPLISHED.SDR 2004UALA01142Floorbeam · corrodedCABIN FLOORBEAM STA 324 AND RBL 53 HAS CORROSION. REMOVED DAMAGED T CAP SECTION AND INSTALLED NEW SECTION SPLICED WITH DOUBLERS.SDR 2004UALA01136Light · deterioratedEMERGENCY EVACUATION LIGHT STRIP AT LAV AREA DETERIORATED. REPLACED LIGHT STRIP.SDR 2004UALA01135Shear Tie · corrodedBS 1400 AFT PIT FRAME SHEAR TIE CORRODED BETWEEN STR 27L & 28L. DAMAGE CAUSED BY CORROSION. REPLACED FRAME SECTION AND CORRODED SHEAR TIES.SDR 2004UALA01127Skin · damagedFUSELAGE SKIN HAS LIGHTNING STRIKE DAMAGE. DAMAGED SKIN WAS CUTOUT AND A DOUBLER REPAIR WAS INSTALLED.SDR 2004UALA01065Floorbeam · corrodedMAIN CABIN STA 324 RS FLOORBEAM CORRODED FROM RBL 40 TO CUSP. REMOVED CORROSION DAMAGE AND INSTALLED FLOORBEAM REPAIR.SDR 2004UALA01064Floorbeam · corrodedMAIN CABIN STA 365 FLOORBEAM CORRODED FROM RBL 26 TO RBL 0. REMOVED DAMAGE, FABRICATED AND INSTALLED REPLACEMENT FLOORBEAM.SDR 2004UALA01063Intercostal · corrodedAFT CARGO PIT STA 1620 RBL 3 INTERCOSTAL WEB HAS CORROSION. REMOVED CORROSION, FABRICATED AND INSTALLED NEW INTERCOSTAL WEB.SDR 2004UALA01062Floorbeam · corrodedSTA 365 RBL 58 TO 63 FLOORBEAM CORRODED. REMOVED CORROSION AND INSTALLED REPAIR TO FLOORBEAM.SDR 2004UALA01061Floor Support · corrodedMAIN CABIN FLOOR SUPPORT CORRODED STA 1660 TO 1680 AT RBL 50 TO 55. TYPICAL FLOOR CORROSION. REMOVED DAMAGE AND REPLACED THE FLOOR SUPPORT.SDR 2004UALA01060Skin · damagedEXTERNAL FUSELAGE STA 736.5 BETWEEN STR 27L AND 28L INTERCOSTAL FASTENER HAS STATIC DISCHARGE HOLE OUT OF LIMITS. REMOVED DAMAGE AND FABRICATED REPAIR DOUBLER FOR SKIN.SDR 2004UALA01114Frame · damagedFRAME AT BS 1400 STR 26L IS DAMAGED. CARGO PIT FRAME DAMAGE DUE TO CARGO HANDLING. FRAME SECTION REPLACED.SDR 2004UALA01066Skin · dentedEXTERIOR FUSELAGE SKIN AT STA 620 ABOVE STR 16L HAS 2 EACH DENTS. REMOVED EXISTING SKIN REPAIRS. REMOVED PORTION OF DAMAGED SKIN PANEL. ACCOMPLISHED A PARTIAL SKIN PANEL REPLACEMENT. SKIN PANEL SPLICED BY DOUBLER STRAPS AND TRIPLERS.SDR 2004UALA01059Frame · dentedAFT PIT STA 1440 FRAME DENTED AT STR 25L. INSTALLED J ANGLE REPAIR.SDR 2004UALA01058Shear Tie · crackedAFT PIT STA 1400 BETWEEN STR 29L AND 30L SHEAR TIE CRACKED. REPLACED SHEAR TIE.SDR 2004UALA01118Light · inoperativeR-2 DOOR EMERGENCY LIGHTS INTERIOR AND EXTERIOR INOP. REPLACED BATTERY PACK AND OPS CHECKED REF MM 33-51-00.SDR 2004UALA01117Wire · brokenR-2 DOOR EEL EXIT MARKER WIRE IS BROKEN. REPAIRED WIRE REF GNMM 2-0-15-001 AND OPS CHECKED.SDR 2004UALA01116Socket · faultyR-1 EXTERNAL EMERGENCY SLIDE ILLUMINATION LIGHT HAS A FAULTY SOCKET ASSEMBLY. REPLACED FAULTY SOCKET. PERFORMED SUCCESSFUL OPERATION CHECK OF LIGHT.SDR 2004UALA01108Frame · dentedAFT PIT FRAME DENTED AT RT SIDE BETWEEN STRINGERS S25R & S26R. REMOVED DAMAGED FRAME CAP AND INSTALLED NESTED J ANGLE REPAIR.SDR 2004UALA01107Frame · dentedAFT PIT FRAME DENTED AT STA 1480 BETWEEN STRINGERS S25L & S26L. REMOVED DAMAGED PORTION OF THE FRAME CAP. INSTALLED NESTED J ANGLE REPAIR.SDR 2004UALA01057Bear Strap · corrodedAFT PIT FUSELAGE SKIN AND BEAR STRAP WERE CORRODED. CORROSION WAS REMOVED AND EXTERNAL DOUBLER REPAIR WAS ACCOMPLISHED.SDR 2004UALA01056Frame · dentedAFT PIT FRAME INNER FLANGE DENTED AT BS 1320 ABOVE STR 26R. INSTALLED J ANGLE REPAIR.SDR 2004UALA01055Frame · dentedAFT PIT FRAME INNER FLANGE DENTED AT BS 1400 ABOVE STR 26L. INSTALLED J ANGLE REPAIR.SDR 2004UALA01054Frame · dentedAFT PIT FRAME DENTED AT STA 1580 ABOVE STRINGER S26L. INSTALLED NESTED ANGLE REPAIR.SDR 2004UALA01053Frame · dentedAFT PIT FRAME DENTED AT STA 1600 ABOVE STR S25L. INSTALLED NESTED ANGLE REPAIR.SDR 2004UALA01052Frame · dentedAFT PIT FRAME DENTED AT STA 1540 BETWEEN STRINGERS 25L & 26L. INSTALLED NESTED J ANGLE REPAIR.SDR 2005UALA00406Floorbeam · damagedFLOORBEAM AT STA 324 RBL 60 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED FLOORBEAM CHORD SPLICE REPAIR.SDR 2004UALA01048Floorbeam · damagedCABIN FLOORBEAM CAP AT BS 324 RBL 44, RBL 48, AND RBL 62 IS CORRODED. SUPPLEMENTAL DATA UPDATE, TYPICAL FLOORBEAM CORROSION. REMOVED DAMAGE AND INSTALLED REPAIR ANGLES TO FLOORBEAMS.SDR 2004UALA01109Frame · dentedAFT PIT FRAME DENTED AT STA 1420 BETWEEN STRINGERS 25L & 26L. TYPICAL CARGO PIT DENT DAMAGE DUE TO CARGO LOADING. REMOVED DAMAGED FRAME CAP AND INSTALLED NESTED J ANGLE REPAIR.SDR 2004UALA01051Frame · dentedAFT PIT FRAME INBOARD FLANGE DENTED AT BS 1320 BETWEEN STR 25L AND 27L. INSTALLED J ANGLE REPAIR.SDR 2004UALA01050Frame · dentedAFT PIT FRAME INNER FLANGE DENTED AT BS 1440 INBOARD OF STR 26L. TYPICAL CARGO PIT DENT DAMAGE. INSTALLED J ANGLE REPAIRS.SDR 2004UALA01049Frame · dentedAFT PIT FRAME INBOARD FLANGE DENTED AT STA 1520 ABOVE STR 26L. TYPICAL CARGO PIT DENT DAMAGE DUE TO CARGO LOADING. INSTALLED J ANGLE REPAIR.SDR 2004UALA01110Floorbeam · corrodedCABIN FLOORBEAM STA 1640 HAS CORROSION RBL 44 TO 52, UPPER CAP. CORRODED SECTION REMOVED AND A FLOORBEAM DOUBLER REPAIR WAS INSTALLED.SDR 2004UALA01119Floorbeam · buckledCARGO PIT FLOOR JUST IN FRONT OF DOORWAY IS SEVERELY BUCKLED.SDR 2004UALA01115Skin · dentedRIGHT FWD FUSELAGE DENTED AND SCRATCHED APPROX 1 FT AFT OF JACKING POINT. REMOVED EXISTING TIME-LIMITED SKIN DOUBLER AND REPLACED WITH NEW DOUBLER AND FILLER REPAIR.SDR 2004UALA01040Proximity Sensor · inoperativeDOORS 2L AND 2R ARMED LTS DO NOT COME ON WITH DOORS ARMED. GIRT BAR ANN LIGHT L406 FOR DOOR 2R FOUND SHORTED - REPLACED LIGHT. 2R FORWARD AND REAR PROXIMITY SENSORS FOUND BAD - BOTH SENSORS REPLACED.SDR 2004UALA01037A/C Pack · smokeCREW REPORTS SMOKE IN CABIN, ISOLATED TO RT PACK. ACM ON RT PACK HOT AFTER 15 MINS SHUTDOWN POSSIBLY DUE TO A FROZEN ACM. REPLACED ACM.SDR 2004UALA01030Floorbeam · corrodedCABIN FLOORBEAM CAP AT BS 310 CORRODED RBL 44. FABRICATED & INSTALLED NESTED ANGLE REPAIR WITH FILLERS & SHIMS.SDR 2004UALA01029Plate · corrodedAFT GALLEY AREA RT SIDE STA 1681-1691 RBL 52 GALLEY DECK PLATE UPPER SURFACE CORRODED. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA01033Slide · will not testEMERGENCY ESCAPE SLIDE 2 WILL NOT TEST. CYLINDER ASSEMBLY TEMPERATURE COMPENSATED PRESSURE SWITCH (TCPS) WAS DETERMINED TO HAVE BEEN DAMAGED DUE TO HANDLING.SDR 2004UALA01024Warning Light · illuminatedAPU SHUTDOWN IN DUE TO OIL QTY MESSAGE AND RIGHT GENERATOR OFF EICAS MESSAGE.SDR 2004UALA01018Floor Support · corrodedMAIN CABIN FLOOR SUPPORT CORRODED AT STA 1640 TO 1660 LBL 50 TO LBL 55. TYPICAL FLOOR STRUCTURE CORROSION. REPLACED FLOOR SUPPORT.SDR 2004UALA01017Floor Support · corrodedMAIN CABIN FLOOR SUPPORT CORRODED AT STA 1660 TO 1680 LBL 50 TO LBL 55. TYPICAL FLOOR STRUCTURE CORROSION. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOOR SUPPORT.SDR 2004UALA01010Skin · puncturedPUNCTURED HOLE IN FUSELAGE AT STA 1862 UPPER LT SIDE. PUNCTURE DAMAGE. FABRICATED & INSTALLED REPAIR DOUBLER AND FILLER.SDR 2004UALA01002Stringer · gougedCABIN STRINGER GOUGED ON LWR SIDE AT STA 620 STR 16L. DAMAGED DURING REPAIR TO SURROUNDING STRUCTURE. BLENDED OUT DAMAGE, FABRICATED HAT CHANNEL REPAIR.SDR 2004UALA00989Frame · dentedAFT PIT BODY FRAME DENTED AT STA 1340 BETWEEN STRINGERS 25R & 26R. MAJOR REPAIR ACCOMPLISHED. TYPICAL CARGO PIT DENT DAMAGE FROM CARGO LOADING. TRIMMED OUT DAMAGE & FABRICATED J-ANGLE REINFORCEMENT REPAIR.SDR 2004UALA01004Frame · dentedSTATION 1500 STRINGER 25L FRAME DENTED AFT PIT. TYPICAL CARGO PIT DENT DAMAGE DURING CARGO LOADING. CUTOUT DAMAGE AND INSTALLED DOUBLER REPAIR.SDR 2004UALA01003Brace · damagedNR 2 PYLON DIAGONAL BRACE HOLE BORES WERE FOUND MISLOCATED. ESTABLISHED CORRECT LOCATION OF DIAGONAL BRACE HOLE. MACHINED AND INSTALLED OVERSIZE BUSHING.
Back to Boeing 757-222