Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2003UALA00259Actuator · leakingCENTER HYDRAULIC SYSTEM QUANTITY EICAS MESSAGE. SYSTEM SECURED AT .23. EXCESSIVE HYDRAULIC LEAKAGE FROM LEFT AILERON POWER CONTROL ACTUATOR (PCA). REPLACED SUBJECT ACTUATOR WITH SERVICEABLE UNIT.SDR 2003UALA00258Fuel Control · failedNUMBER 1 ENGINE N1 OVERSPEED OF 103 PERCENT FOR 40 SECONDS. N1 PASSED 100.5 REDLINE FOR 42 SECONDS AND REACHED A MAXIMUM OF 103.0. NO OTHER EXCEEDENCES OCCURRED. INITIAL PROGNOSIS IS A MECHANICAL FAULT IN THE FUEL CONTROL UNIT.SDR 2003UALA00254Floor Support · corrodedCABIN FLOOR SUPPORT CORROSION ON UPPER SURFACE, STA 367, RBL 9. MAJOR REPAIR ACCOMPLISHED. REPLACED SUPPORT AT BS 367, STR 9, WL 208.SDR 2003UALA00257Light · burned outDOOR 1R EMERGENCY SLIDE LIGHT ON OUTSIDE OF FUSELAGE IS INOP. REPLACED/RELAMPED BURNED OUT LIGHT.SDR 2003UALA00255Floor Panel · damagedCABIN PRESSURE DECK FLOOR HAS EXCESS MATERIAL LOSS AT STA 1681, RBL 43 AND RBL 52. MAJOR REPAIR ACCOMPLISHED. DOUBLER APPLIED.SDR 2003UALA00256Light · burned outDOOR 4R EMERGENCY SLIDE LIGHT ON OUTSIDE OF FUSELAGE IS INOP. SLIDE LIGHT REPLACED/RELAMPED.SDR 2003UALA00253Switch · failedA/C RECEIVED NR 1 ENGINE OIL FILTER BYPASS MESSAGE. DELTA PRESSURE SWITCH AND OIL FILTER REPLACED.SDR 2003UALA00237Module · shortedA/C RECEIVED WHEEL WELL FIRE INDICATION. WHEEL WELL FIRE INDICATION FOUND TO BE CAUSED BY P-3 WHEEL WELL FIRE ANNUNCIATOR L445. ANNUNCIATOR MODULE REPLACED AND OPERATED NORMAL. REMOVED PART TO BE EVALUATED BY VENDOR.SDR 2003UALA00236Actuator · wornWHILE PLACING FLAPS IN UP POSITION, LEADING EDGE SLAT DISAGREE INDICATION CAME ON. INHIBITED SLAT MOVEMENT DUE TO FAULTED NR 11 LEADING EDGE SLAT ACTUATOR. REMOVED AND REPLACED THE SUBJECT LEADING EDGE SLAT ACTUATOR WITH NEW SERVICEABLE ACTUATORSDR 2003UALA00234Light · inoperativeEEL STRIP INOPERATIVE, IN FRONT OF AFT LAV. REPLACED EEL STRIP.SDR 2003UALA00235Actuator · wornSLAT DISAGREE INDICATION CAME ON AFTER TAKE-OFF. INHIBITED SLAT MOVEMENT DUE TO FAULTED NR 11 LEADING EDGE SLAT ACTUATOR. REMOVED AND REPLACED THE SUBJECT LEADING EDGE SLAT ACTUATOR WITH NEW SERVICEABLE ACTUATORSDR 2003UALA00224Skin · dentedSTA 600 FUSELAGE EXTERNAL SKIN HAS 3 EA DENTS AND GOUGES ABOVE DOUBLER AT STR 17L. MAJOR REPAIR ACCOMPLISHED. SKIN PANEL WAS REPLACED FROM STA 594 TO 660 BUTT JOINT AND FROM STR 14L SKIN LAP TO STR 19L SKIN LAP, SPLICE DOUBLER AT STA 594.SDR 2003UALA00203Skin · crackedFUSELAGE EXTERNAL SKIN IS DENTED AND CRACKED AT BS 1520, STRINGER 23R. MAJOR REPAIR ACCOMPLISHED. SKIN REPAIRED WITH DOUBLER.SDR 2003UALA00194Shear Tie · damagedLEFT AT STA 640 SHEARTIE BETWEEN STR 14L AND 15L DAMAGED. MAJOR REPAIR ACCOMPLISHED. SHEAR TIE CLIP REPLACED.SDR 2003UALA00192Floor Panel · corrodedAFT CABIN FLOOR PLATE CORR0DED AT STA 1680 - 1684, RBL 45 TO RBL 53. RECHECKED FOR EXCESSIVE MATERIAL LOSS AT STA 1681 RBL 49-50 AND RBL 51-53. MAJOR REPAIR ACCOMPLISHED. AFT CABIN FLOOR DECK PLATE CORROSION BLENDED AND REPAIR DOUBLER INSTALLED AT STA 1681SDR 2003UALA00225Crease Beam · dentedCABIN CREASE BEAM DENTED AT STA 638, STR 17L, WL 207. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASEBEAM OUTER CHORD FROM STA 630 TO 662 WITH SPLICE AT STA 630.SDR 2003UALA00180Controller · failedRT ENGINE HIGH STAGE LIGHT ON DURING TAKE OFF ROLL. SUPPLEMENTAL DATA UPDATE ROOT CAUSE: HIGH STAGE CONTROLLER OVER PRESSURE SENSOR & ANTI-ICE SWITCHER CALIBRATION WAS OUT. REPLACED CONTROLLER.SDR 2003UALA00171Skin · cutFWD CARGO DOOR, AFT LOWER CORNER, FOUND DAMAGE TO DOOR OUTER SKIN. 3-16 BY 1-4 INCH V CUT IN DOOR SKIN. MAJOR REPAIR ACCOMPLISHED. BELENDED OUT DAMAGE BY MANUFACTURING DOUBLER.SDR 2003UALA00161Skin · damagedSKIN DAMAGE BY JETWAY FORWARD OF DOOR 2L. MAJOR REPAIR ACCOMPLISHED. FUSELAGE SKIN REPLACED.SDR 2003UALA00160Smoke · detectedFLASH REPORTED NEAR MID-LAV, THEN SMOKE COMING OUT OF LAV. NO FLAME OR FIRE REPORTED.SDR 2003UALA00143Crease Beam · damagedMID CABIN BS 612 CREASE BEAM LEFT SIDE, TOOLING DAMAGE ON BOTTOM OF HORIZONTAL FLANGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED AREA AND INSTALLED 2 EACH UPPER AND LOWER REPAIR ANGLES.SDR 2003UALA00132Skin · crackedNR 1 PYLON STRUT OUTBOARD SIDE SKIN IS CRACKED AT FORWARD ACCESS HOLE. MAJOR REPAIR ACCOMPLISHED. REPAIRED WITH DOUBLERS.SDR 2003UALA00131Skin · dentedDENT LEFT SIDE OF A/C BETWEEN STRINGER 14 & 15 AT STATION 1615. A OVER Y IS 32. DIA 3-64 BY 1.5 INCHES. HFEC ACCOMPLISHED/NO CRACKS NOTED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND INSTALLED DOUBLER AND TRIPLER REPAIR.SDR 2003UALA00103Link · failedLEFT MAIN LANDING GEAR DID NOT RETRACT AFTER TAKEOFF. CYCLED GEAR STILL DID NOT RETRACT. SEQUENCE VALVE LINK FAILED. REPLACED LINK ASSEMBLYSDR 2003UALA00105Skin · dentedSCRAPE ON BOTTOM SURFACE OF RIGHT WING, 3 FEET INBD FROM TIP. FOUND DENT 3 BY 6 INCHES WITH DELAM. MAJOR REPAIR ACCOMPLISHED. ACCOMPLISHED QUADRUPLER REPAIR.SDR 2003UALA00133Structure · delaminatedTRAILING EDGE WEDGE SLAT NR 5 DELAMINATED. MAJOR REPAIR ACCOMPLISHED. REPAIRED RIGHT T/E IN SHOP.SDR 2003UALA00104Pressure Panel · damagedAFT CABIN PRESSURE DECK WEB, STA 1681 - RBL 50 TO 52, HAS EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. REPAIRED DECK WITH FILLER AND DOUBLER.SDR 2003UALA00070Skin · dentedLH EXTERNAL FUSELAGE SKIN HAS DENT 6" AFT OF CABIN PRESSURE STATIC PORT BETWEEN STRINGER 22L-23L, STA. 1370. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2003UALA00063Indicator · failedCAPTAINS AIRSPEED INDICATOR FLAGGED. CAPTAIN'S MACH/AIRSPEED INDICATOR FAILED AND WAS REPLACED.SDR 2003UALA00064Floorbeam · crackedFLOORBEAM CRACKED AT FLOOR SUPPORT ATTACH CLIP, STA 700 LBL 46. MAJOR REPAIR ACCOMPLISHED. INSTALLED T-CAP REPAIR.SDR 2003UALA00060Skin · dentedSHARP DENT FOUND ON SKIN REPAIR DOUBLER BETWEEN BS600 AND 620 AND STR 16L AND 17L; MORE DENTS BETWEEN BS600 AND 660, STR 14L AND 19L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER SKIN.SDR 2003UALA00057Floorbeam · crackedSTATION 660, LBL 46, FLOORBEAM IS CRACKED AT FLOOR SUPPORT ATTACH CLIP. MAJOR REPAIR ACCOMPLISHED AT FLOOR BEAM UPPER CAP. PERFORMED SPLICE REPAIR.SDR 2003UALA00056Floorbeam · corrodedSTATION 680, CABIN FLOORBEAM UPPER CAP CORRODED. MAJOR REPAIR ACCOMPLISHED. UPPER FLANGE REPAIRED WITH DOUBLER.SDR 2003UALA00046Controller · failedLEFT ENGINE BLEED PRESSURE REGULATING AND SHUTOFF VALVE FAILURE PRIOR TO ENTERING ETOPS ENVIRONMENT. SUPPLEMENTAL DATA UPDATE HIGH STAGE PILOT CONTROLLER FAILED. REPLACED HIGH STAGE PILOT CONTROLLER.SDR 2003UALA00048Floorbeam · corrodedCABIN FLOOR BEAM UPPER CHORD HAS INTERGRANULAR CORROSION BODY STATION 310, RBL 40-45. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOORBEAM UPPER CAP.SDR 2003UALA00049Sensor · failedFIRE IN THE LEFT AFT LAV UNDER THE SEAT SHROUD. LIQUID LEVEL SENSOR FAILED INTERNALLY CAUSING A FIRE THAT DAMAGED THE SENSOR ITSELF ALONG WITH THE TOILET SEAT SHROUD AND A NEARBY AIR VENT. REPLACED LIQUID LEVEL SENSOR, TOILET SHROUD, AND VENT ASSEMBLY AND RSDR 2003UALA00039Floorbeam · corrodedSTATION 1640 RBL 58 FLOORBEAM UPPER CAP CORRODED. MAJOR REPAIR ACCOMPLISHED. REPAIR T CAP INSTALLED.SDR 2003UALA00028Idg · failedNR 1 GENERATOR DRIVE LIGHT ILLUMINATED PRIOR TO ENTERING ETOPS. DISCONNECTED GENERATOR. APU SUPPLIED POWER. LEFT AC INTEGRATED DRIVE GENERATOR (IDG) FAILURE. REPLACED THE LEFT IDG. CARRIER SHAFT FROZEN. REPLACED THE SHAFT AND OVERHAULED THE IDG.SDR 2003UALA00017Web · corrodedCABIN FLOOR STRUCTURE AT STATION 998 TO 1002 LBL 67 AT STRINGER 17L CREASE BEAM WEB CORRODED ON UPPER SURFACE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.INSTALLED NEW WEB.SDR 2003UALA00016Plate · corrodedSTATION 1680 TO 1684, RBL44 TO RBL54.5, AFT DECK PLATE CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.SDR 2003UALA00002Floorbeam · corrodedCABIN FLOORBEAM UPPER CHORD CORRODED, STA 365, RBL 5-15. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR ANGLES.SDR 2002UALA01901Blade · failedRT ENGINE EICAS MSG FOR FUEL FILTER. SUPPLEMENTAL DATA UPDATE AT ENGINE TEARDOWN, A STAGE 2 TURBINE BLADE FAILURE WAS FOUND TO BE THE CAUSE.SDR 2002UALA01891Skin · lightning strikeLEFT HAND FUSELAGE SKIN LIGHTNING STRIKE LOCATION STATION 654 ON STRINGER 21L. MAJOR REPAIR ACCOMPLISHED. HFEC ACCOMPLISHED AND REINSTALLED FASTENER.SDR 2002UALA01853Control Valve · malfunctionedON CLIMBOUT LEFT PACK CYCLED ON AND OFF EVERY TWO SECONDS. TURNED LEFT PACK OFF. RIGHT PACK UNABLE TO HOLD CABIN PRESSURE. REPLACED, LEFT PACK FLOW CONTROL VALVE / LEFT ENGINE PRSOV. FOUND RIGHT PACK DUCT SUPPLY TUBE SEPARATED FROM CHECK VALVE. WHEN LEFT SDR 2002UALA01852Floorbeam · corrodedSTATION 1640, RBL 57 FLOORBEAM UPPER CAP CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPAIR ANGLE INSTALLED.SDR 2002UALA01850Floorbeam · corrodedCABIN FLOORBEAM UPPER CAP CORRODED AT STA 324, RBL 45, 50, 53, 57 AND 58 (BOTH FWD AND AFT SIDES OF UPPER CAP) MAJOR REPAIR ACCOMPLISHED. FLOORBEAM CAP REPLACED.SDR 2002UALA01849Sill · damagedLT ENTRY DOOR WAY CUT OUT UPPER SILL HAS 4 HOLES DRILLED INTO IT. MAJOR REPAIR ACCOMPLISHED. REPAIR STRAP.SDR 2002UALA01840Floorbeam · corrodedCABIN FLOORBEAM HAS CORROSION UNDER GUTTER AT BS 365, RBL 59-61. MAJOR REPAIR ACCOMPLISHED. INSTALLED CABIN FLOOR BEAM UPPER CAP "I" BEAM REDUCED SPLICE LENGTH REPAIR.SDR 2002UALA01838Floor Support · crackedFWD NOSE COMPARTMENT STATION 202, AT STRINGER 18 RIGHT HORIZONTAL FLOOR SUPPORT ANGLE CRACKED IN RADIUS AND ALONG HORIZONTAL FLOOR WEB. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOOR SUPPORT ANGLE WEB.SDR 2002UALA01837Crease Beam · corrodedCABIN CREASE BEAM HAS CORROSION AT STATION 324 RBL 62. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REPLACED INBOARD CREASE BEAM CHORD.
Back to Boeing 757-222