Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2002UALA00845Floorbeam · corrodedCABIN FLOORBEAM TOP FLANGE CORRODED BODY STATION 1640, RBL 44 THROUGH RBL 62. MAJOR REPAIR ACCOMPLISHED. INSTALLED SPLICE REPAIR.SDR 2002UALA00844Splice · corrodedFUSELAGE STRINGER SPLICE STRINGER 27R STATION 1486 CORRODED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.REPLACED STRINGER SPLICE.SDR 2002UALA00837Frame · corrodedAFT PIT FRAME CORRODED, STATION 1480 RBL 27 STRINGER 27 UNDERNEATH RT Z ANGLE. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA00836Pressure Panel · corrodedAFT CABIN PRESSURE DECK CORRODED AT STATION 1681 RBL 12. MAJOR REPAIR ACCOMPLISHED. INSTALLED FILLER AND DOUBLER.SDR 2002UALA00835Floorbeam · corrodedCABIN FLOORBEAM 1681 RBL 12 CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP AND ANGLE REPAIRS WITH FILLER.SDR 2002UALA00831Floorbeam · corrodedCABIN FLOORBEAM UPPER CAP STATION 1640, RBL 51 CORRODED. MAJOR REPAIR ACCOMPLISHED. STRAP REPAIR INSTALLED.SDR 2002UALA00830Angle · corrodedMID CABIN DOOR SILL Z-ANGLE INNER AT STATION 720 CORRODED. MAJOR REPAIR ACCOMPLISHED. REPAIRED WITH A NEW SILL BEAM.SDR 2002UALA00819Actuator · bypassingGEAR UP DISAGREE LIGHT ILLUMINATED. NLG RETRACT ACTUATOR BYPASSING AND NOT RETRACTING GEAR. REPLACED NLG RETRACT ACTUATOR.SDR 2002UALA00828Seat Track · crackedLH OB SEAT TRACK CRACKED AT OB FASTENER HOLE STATION 1200. MAJOR REPAIR ACCOMPLISHED.SPLICED IN NEW SEAT TRACK SECTION.SDR 2002UALA00827Skin · dentedLEFT HAND EXTERIOR FUSELAGE SKIN BODY STATION 610, 8" BELOW 17L STRINGER IS DENTED. MAJOR REPAIR ACCOMPLISHED.REMOVED DAMAGE AND INSTALLED DOUBLER AND FILLER.SDR 2002UALA00826Web · damagedCABIN INTERCOSTAL BETWEEN STATION 540 AND 560 AT C-L UPPER ANGLE MISDRILLED AND WEB WAS DAMAGED. MAJOR REPAIR ACCOMPLISHED. INTERCOSTAL UPPER ANGLE AND WEB REPLACED.SDR 2002UALA00825Floorbeam · gougedCABIN FLOORBEAM STATION 1420 TOP SURFACE HAS GOUGES AROUND FASTENER HOLES, LBL 18 TO RBL 5 AT WL 208. MAJOR REPAIR ACCOMPLISHED. INSTALLED REINFORCEMENT STRAPS.SDR 2002UALA00818Oil Filter · dirtyRIGHT ENGINE OIL FILTER LIGHT ILLUMINATED. OIL FILTER AND CHIP DETECTORS CHECKED CLEAN. BYPASS SWITCH CHECKED GOOD. OIL FILTER REPLACED.SDR 2002UALA00824Floor Support · corrodedCABIN FLOOR SUPPORT ANGLE CORRODED AT STATION 736, RBL 68, WL 208. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM ANGLE.SDR 2002UALA00823Frame · dentedAIRCRAFT FRAME IN AFT PIT DENTED, STATION 1420 BETWEEN STRINGER 25 AND STRINGER 26L. MAJOR REPAIR ACCOMPLISHED.REMOVED DAMAGE, INSTALLED DOUBLER.SDR 2002UALA00822Splice Plate · corrodedAFT PIT FRAME SPLICE PLATE AT STATION 1520 STRINGER 25R WAS BLENDED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED.SPLICE PLATE WAS REPLACED.SDR 2002UALA00821Beam · damagedCABIN FLOOR STATION 345-365 BELOW I-BEAM IS DAMAGED. MAJOR REPAIR ACCOMPLISHED. I-BEAM REPLACED.SDR 2002UALA00804Crease Beam · corrodedCABIN CREASE BEAM WEB UPPER SURFACE CORRODED BODY STATION 982, LBL 71 WL 208. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM WEB.SDR 2002UALA00795Frame · dentedAFT PIT FRAME AT STATION 1470 STRINGER 25L IS DENTED. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.INSTALLED DOUBLER REPAIR.SDR 2002UALA00794Frame · damagedFORWARD PIT CENTER LINE CIRCUMFERENTIAL FRAME STATION 800 HAS LOADER JACK-SCREW DAMAGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.INSTALLED DOUBLER REPAIR ON FRAME.SDR 2002UALA00790Crease Beam · corrodedMID CABIN CREASE BEAM HAS EXCESSIVE MATERIAL LOSS AT BODY STATION 1408 RBL71. MAJOR REPAIR ACCOMPLISHED.REPLACED CREASE BEAM.SDR 2002UALA00786Flange · wornAFT PIT FRAME FLANGE AFT SIDE LIP WORN, 2 EACH AREAS FROM FASTENERS STA 1520 BETWEEN STRINGER 22R AND 23R. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.L-ANGLE DOUBLER INSTALLED.SDR 2002UALA00785Floorbeam · corrodedCABIN FLOORBEAM IS CORRODED AT STA 1640, RBL 50 TO RBL 60. MAJOR REPAIR ACCOMPLISHED. SPLICED IN A NEW FLOORBEAM CAP.SDR 2002UALA00784Floorbeam · corrodedCABIN FLOORBEAM CORRODED AT BODY STATION 345, RBL 36. MAJOR REPAIR ACCOMPLISHED. DAMAGED AREA CUT OUT RBL 34.5 - 37 FORWARD FLANGE ONLY. NESTED DOUBLE ANGLE AND STRAP APPLIED TO FLOORBEAM, RBL 31-41.SDR 2002UALA00783Battery Pack · dischargedEMERGENCY FLOOR LIGHTING INOP BEGINNING ROW 27 GOING AFT. REPLACED BATTERY PACK.SDR 2002UALA00765Control UnitFUEL CONFIGURATION LIGHT ILLUMINATED. SUPPLEMENTAL DATA UPDATE THE CAUSE WAS A COMBINATION OF A LEAK IN THE RIGHT ENGINE DRY BAY AND A DEFECTIVE RIGHT MAIN TANK FUEL FILL VALVE CONTROL UNIT. THE PRIMARY CAUSE OF IMBALANCE CAN BE ATTRIBUTED TO THE FUEL FILL VASDR 2002UALA00762Frame · corrodedFORWARD PIT STATION 780 BELOW FUSELAGE FRAME UPPER CAP HAS EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2002UALA00761Frame · damagedFORWARD PIT STATION 760 BEL0W FUSELAGE FRAME DAMAGED FROM LOADER JACKSCREW. MAJOR REPAIR ACCOMPLISHED.INSTALLED DOUBLER REPAIR.SDR 2002UALA00755Frame · damagedSTATION 740 BEL0W FORWARD PIT FUSE FRAME HAS DAMAGE FROM TELESCOPING LOADER JACKSCREW. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER AND STRAP REPAIR.SDR 2002UALA00732Threshold · corrodedAFT CARGO PIT THRESHOLD LOWER BEAM PREVIOUS REPAIR HAD SEVERE EXFOLIATION CORROSION AT REPAIR ANGLE AND BOTH SPLICE PLATES STATION 1436 TO STATION 1383. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. INSTALLED FILLER SECTION AND TWO EA REPAIR ANGLES.SDR 2002UALA00731Frame · dentedAFT PIT STATIO 1400 BETWEENS TATION 25L AND 26L FRAME IS DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED EXTERNAL DOUBLER REPAIR.SDR 2002UALA00724Crease Beam · corrodedAFT PIT STATION 1638, LT CREASE BEAM, OUTER CHORD ANGLE CORRODED. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2002UALA00723Floorbeam · corrodedCABIN FLOORBEAM UPPER CAP HAD CORROSION ON UNDER SIDE AT STATION 365 AT APPROX RBL 36 STRINGER 17R. MAJOR REPAIR ACCOMPLISHED. REMOVED PORTION OF UPPER T-CAP AND USED SPLICE REPAIR IN INSTALLING NEW UPPER T-CAP.SDR 2002UALA00718Plate · corrodedAFT CABIN DECKPLATE CORRODED STATION 1690 TO 1694 RBL 50. MAJOR REPAIR ACCOMPLISHED. REPAIRED DOUBLER INSTALLED.SDR 2002UALA00708Floorbeam · corrodedCABIN FLOORBEAM STATION 1640 DAMAGED AND CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED T-CAP.SDR 2002UALA00707Frame · dentedAFT PIT FUSELAGE FRAME INNER FLANGE DENTS STATION 1380 STRINGER 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR ON FLANGE.SDR 2002UALA00709Frame · gougedAFT CARGO PIT FRAME STATION 1280 LBL 23 IS GOUGED. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE AND INSTALLED TWO REPAIR STRAPS.SDR 2002UALA00710Frame · damagedAFT PIT FRAME BODY STATION 1620 ABOVE STRINGER 26R EDGE DAMAGED FROM DRILL START. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED.DOUBLER REPAIR APPLIED TO WEB AND INBD CAP.SDR 2002UALA00679Floorbeam · corrodedFORWARD CABIN FLOORBEAM AT STATION 297 RBL 40 CORRODED. MAJOR REPAIR ACCOMPLISHED DOUBLER REPAIR INSTALLED.SDR 2002UALA00678Floorbeam · corrodedFLOORBEAM AT STATION 365 RBL18 MATERIAL LOSS BEYOND 10 PERCENT LIMIT FORWARD EDGE. MAJOR REPAIR ACCOMPLISHEDFILLER INSTALLED AND TWO EACH ANGLES NESTED UNDER FLOORBEAM CAP.SDR 2002UALA00673Crease Beam · corrodedCABIN CREASE BEAM INBOARD CHORD VERTICAL LEG CORRODED STATION 900 TO 1040, LBL 64. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA00672Crease Beam · corrodedCAB FLOOR CREASE BEAM INNER CHORD UPPER FLANGE BETWEEN STATION 1580 TO 1600, RBL 44, IS CORRODED. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR WAS PERFORMED ON CREASE BEAM AT STATION 1580 TO 1600, RBL 44.SDR 2002UALA00671Frame · dentedAFT PIT FRAME LT SIDE AT STA 1520 ABOVE STRINGER 26L IS DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED TRIPLER REPAIR TO FRAME AT STA 1520, STRINGER 26L.SDR 2002UALA00663Floor Support · crackedAFT PIT FLOOR SUPPORT STATION 1340 TO STATION 1440 RBL 3 IS CRACKED AND CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOOR SUPPORT.SDR 2002UALA00658Floorbeam · corrodedCABIN FLOORBEAM HAD CORROSION MATERIAL REMOVED EXCEEDS LIMITS, STATION 345 RBL 52 UPPER FLANGE AFT SIDE. MAJOR REPAIR ACCOMPLISHED. UPPER CAP REPAIRED.SDR 2002UALA00652Floor Support · corrodedFORWARD PIT STATION 684, RBL 16, FLOOR SUPPORT ANGLE CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOOR SUPPORT ANGLE.SDR 2002UALA00651Floorbeam · corrodedCABIN FLOOR BEAM UPPER CHORD STATION 1640 LBL 56 HAS EXCESSIVE MATERIAL REMOVED. MAJOR REPAIR ACCOMPLISHED. FLOORBEAM UPPER CHORD AFT FLANGE REPAIRED AND STRAP INSTALLED.SDR 2002UALA00643Crease Beam · corrodedLEFT HAND CREASE BEAM WEB AT BODY STATION 1020-1023 HAS EXCESSIVE MATERIAL LOSS AFTER REMOVAL OF CORROSION. MAJOR REPAIR ACCOMPLISHED. CREASE BEAM WEB REPLACED.SDR 2002UALA00642Crease Beam · corrodedLEFT HAND CREASE BEAM WEB AT BODY STATION 1020-1023 HAS EXCESSIVE MATERIAL LOSS AFTER REMOVAL OF CORROSION. MAJOR REPAIR ACCOMPLISHED. CREASE BEAM WEB REPLACED.SDR 2002UALA00641Floor Support · corrodedCABIN FLOOR SUPPORT AT STATION 365 RBL 45 HAS EXCESSIVE MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. FILLER AND DOUBLER INSTALLED.
Back to Boeing 757-222