SDR UALA2013032701953Access Panel · leakingFUEL LEAKING FROM ACCESS PANEL UNDER RIGHT WING. FOUND ACCESS PANEL 642AB IMPROPERLY INSTALLED. REMOVED AND INSTALLED ACCESS PANEL. LEAK CHECKED GOOD, NO DEFECTS NOTED.SDR UALA2013032701952Pan · gougedL4 DOOR PAN AT BUTTERFLY HANDLE HAS A DEEP GOUGE. BLENDED GOUGE MEASURED TO BE WITHIN LIMITS PER SRM. ACCOMPLISHED REPAIR, REF ECRA 5210-02364.SDR UALA2013032701951Warning Message · false activationFLAP/SLAT STATUS MESSAGE DISPLAYED AND WILL NOT ERASE. RESET FLAP UNIT BITE, SYSTEM OPERATES NORMAL.SDR UALA2013032601908Module · damagedRT ENGINE START VALVE LIGHT INOPERATIVE. SPRING IN LIGHT ASSY WEAK. REPLACED MASTER MODULE, TESTED OK ON ENGINE START.SDR UALA2013032701940Skin · debondedNR 9 SLAT UPPER T/E WEDGE DEBONDED 11 INCHES FROM I/B END. REPAIRED NR 9 SLAT IAW SRM 51-70-10 REPAIR 4 FIG 202.SDR UALA2013032701939Skin · debondedNR 9 SLAT LOWER SURFACE HAS DEDBONDED AT OSS 584 TWO PLACES 1.5" APART. REPAIRED NR 9 SLAT IAW SRM 51-70-10 REPAIR 4 FIG 202.SDR UALA2013032701938Skin · debondedA 1.5 X 1.5 INCH ON LOWER SURFACE OF NR 1 SLAT T/E WEDGE 19 INCHES FROM O/B EDGE AND 8 INCHES FROM T/E DEDBONDED. REPAIRED NR 1 SLAT IAW SRM 51-70-10 REPAIR 2 FIG 203.SDR UALA2013032701937Skin · debondedNR 1 SLAT T/E WEDGE BOTTOM SURFACE 9 INCHES FROM O/B END DEBONDED. REPAIRED NR 1 SLAT T/E WEDGE IAW SRM 51-70-10 REPAIR 2 FIG 203.SDR UALA2013032701936Skin · delaminatedSKIN DEBONDED ON LOWER SURFACE I/B EDGE OF NR 4 SLAT T/E. REPAIRED NR 4 SLAT IAW SRM 51-70-10 REPAIR 2 FIG 203.SDR UALA2013032701935Skin · delaminatedNR 7 SLAT DISBONDED LOWER SURFACE T/E WEDGE 40 INCHES FROM I/B END. REPAIRED NR 7 SLAT IAW SRM 51-70-10 REPAIR 2 FIG 203.SDR UALA2013032902050Seal · leakingNR 2 ENG OIL CONSUMPTION CONTINUES TO INCREASE THE DEOILER ROTATING RING AND SEALS HAVE BEEN REPLACED. NOW CHECK FOR OIL LEAKS PER MM 79-00-95 PG 201 AND MM71-05-00 FIG 109. IF NO LEAKS FOUND ON VISUAL CHECKS RUN ENG AT 80% N1 FOR MINIMUM OF 10 MINUTES WITH SDR UALA2013032902034Blade · nickedSEVERAL BLADES IN INLET OF NR 1 ENGINE HAVE NICKS IN THEM. BLENDED BLADES PER 72-31- 02. PERFORMED HFEC INSPECTION OF BLADES REF NDT MANUAL PT 6 72-31-401, NO CRACK INDICATIONS.SDR UALA2013032701949Seal · out of positionTHE 4R DOOR SEAL SQUEAL AT ALT AND DESCENT FWD TOP. INSPECTED DOOR 4R DOOR SEAL AND DOOR FRAME FROM INSIDE AND FROM LIFT TRUCK, FOUND INNER DOOR FRAME COSMETIC SEAL PULLED OUT OF ITS TRACK AND INTERFERING WITH DOOR PRESSURE SEAL AT FWD TOP SIDE, SUSPECT THIS SDR UALA2013032701948Outflow Valve · faultyOVERBOARD EX VAL TEST STATUS MESSAGE WILL NOT CLEAR, HAD HARD FAULT THAT WOULD NOT CLEAR. REPLACED OVERBOARD EXHAUST VALVE AND AIR FILTER ASSY. OPS CHECKS GOOD. FAULTS CLEARED.SDR UALA2013032601921Connector · unsecureEMERGENCY LIGHTS AT SEATS 21-23ABC AND 25-26ABC ARE INOPERATIVE. SECURED CONNECTOR UNDER SEAT 24ABC. CHECKED LIGHTS AT 21-23 AND 24-25 ABC. CHECKED OKAY.SDR UALA2013032601916Filter · warning messageRIGHT ENGINE FUEL FILTER EICAS, RETURNED TO FIELD. REPLACED FUEL FILTER PER AMM. OPS & LEAK CHECKED GOOD. NO DEFECTS NOTED.SDR UALA2013032601905Pitot Tube · failedCREW REPORTS R AUX PIPOT EICAS ON TAXI OUT AFTER ENG START. REPLACED R AUX PITOT TUBE L. LEAKED AND OP CHECKED REF AMM. CHECKED OKAY.SDR UALA2013032601911Lens · crackedFOUND EMERGENCY LIGHT LENS CRACK AFT OF LEFT WING. REPLACED LENS. OPS CHECKED OKAY.SDR UALA2013032601902Apu · faultyAPU INOPERATIVE.SDR UALA2013032501876Lamp · inoperativeFOUND LT WING OFF WING SLIDE EMERGENCY LIGHT INOP. RELAMPED PER MM, OPS CHECKED NORMALSDR UALA2013032902039Window · damagedDURING CRUISE, ICE IN BETWEEN WINDOW PANES AT SEAT 20A. REPLACED PASSENGER WINDOW ASSY.SDR UALA2013032601906Mechanism · faultyR4 DOOR SLIDE ARMED LIGHT INOPERATIVE. REPLACED GIRT BAR MECHANISM BEARINGS. ADJUSTED GIRT BAR MECHANISM PER AMM, OPS CHECKED NORMAL.SDR UALA2013032601889Support Fitting · corrodedCORROSION ON MAIN CABIN GALLEY SUPPORT BS 365-377 RBL 57. REMOVED CORROSION FROM GALLEY SUPPORT BS 365-377 RBL57, OUT OF SRM LIMITS. REPLACED GALLEY SUPPORT IAW SRM 53-00-04 FIG 101, 51-40-02 FIG 12, AMM 51-00-53 PG 201-234, DWG 141N5161.SDR UALA2013032601888Support Fitting · corrodedCORROSION ON MAIN CABIN GALLEY SUPPORT BS 365-377.7 RBL 12. REMOVED AND CORROSION FROM GALLEY SUPPORT FITTING, FOUND OUT OF SRM LIMITS. REMOVED AND REPLACED GALLEY SUPPORT IAW SRM 53-00-04 FIG 101, 51-40-02 PG 4-7 FIG 1 2, 51-00-53 PG 201-234 DWG 141N5161.SDR UALA2013032501885Light · unsecureEMERGENCY LIGHT BY 40C IS COMING APART. SECURED EMERGENCY LIGHT, LIGHT OPS NORMAL.SDR UALA2013032902049Cover · damagedEMERGENCY FLOOR LIGHTING LOOSE ROW 40. REPLACED DAMAGED EMERGENCY LIGHT TRACK COVER AND EMERGENCY LIGHT ILLUMINATION, TESTED GOOD.SDR UALA2013032902044Selector · malfunctionedSTATUS MSG CABIN ALT AUTO 1 WILL NOT CLEAR. PLEASE TROUBLESHOOT TO CONFIRM NEED. REF FIM 21-30-00 PG 111 FIG 104 FOR TROUBLESHOOTING. RPL- :4 HITS ON BITE TEST OF AUTO 1 PRESS CONTROLLER FOR SELECTOR, REPLACED SELECTOR AND TESTED PER MM, CHECKS GOOD.SDR UALA2013032601890Stringer · damagedSTRINGER 18L UPPER FLANGE BETWEEN FRAMES 560L - 580L HAS HOLE. DAMAGE WAS REMOVED AND REPAIRED IAW SRM 53-00-03 REPAIR 3.SDR UALA2013032601887Skin · dentedEXTERNAL SKIN DENT WITH GOUGE ON AFT PIT LWR AFT CORNER. REPAIRED SKIN IAW SRM 52-30-01 FIG 201 REPAIR 4.SDR UALA2013032701958Antenna · damagedLOWER FWD FUSELAGE VHF ANTENNA HAS DELAMINATION AND SURFACE CORROSION MARKED. REMOVED AND REPLACED LOWER FWD FUSELAGE VHF ANTENNA IAW B757 AC MM 23-12-03 GND TEST NORMAL.SDR UALA2013032601909Apu · inoperativeAPU INOPERATIVE. REPLACED APU.SDR UALA2013032601907Girt Bar · dirtyDEBRIS IN DOOR SILL AND GIRT BAR AREA. REMOVED DEBRIS. REMOVED MED SLIDE PACK L4 AND LUBED BEARINGS. INSTALLED SAME SLIDE PACK ARM DISARM FUNCTION AND SLIDE LIGHT CHECKED OK.SDR UALA2013032601904Amu · failedACARS FAILED IN FLIGHT. REPLACED AMU PER MM, OPS CHECKED NORMAL.SDR UALA2013032601903Lanyard · out of positionLONG PIECE OF STRING HANGING OUT SLIDE PACK DOOR 2L RESTOWED LANYARD.SDR UALA2013032501874Skin · damagedFORWARD LOWER FUSELAGE EXTERIOR SKIN BS 500 BETWEEN STR 28-29L. REPAIRED IAW SRM 53-00-01 FIG 201 REPAIR 3 PG201-206.SDR UALA2013032501873Frame · corrodedCORROSION ON FORWARD SIDE OF FRAME BS 1460 BETWEEN S29-30L. REPAIRED IAW ECRA 5310-05711.SDR UALA2013032501872Structure · corrodedFOUND CORROSION FWD AND AFT SIDE STA 1400 BETWEEN 29L-30L.SDR UALA2013032501870Threshold · damagedTOOL DAMAGE AT S15L BS 1702-1717. REPAIRED IAW ECRA 5331-01697.SDR UALA2013032501869Threshold · bulgedREPAIR DOUBLER BS 1710 STR 15L BULGED. INSPECTED THRESHOLD, REPAIRED PER ECRA 5331-01697. MAJOR REPAIRSDR UALA2013032501886Generator · faultyAPU GENERATOR FIELD OFF LIGHT ILLUMINATED. WILL NOT RESET. BPCU BIT FOR APU SHOWS GENERATOR TRIPPED REPLACED GENERATOR DIODE. APU GENERATOR WILL NOT TAKE LOAD AND SHOWS NO FREQUENCIES AND VOLTS. REPLACED APU GENERATOR. RAN APU AND LOADED GENERATOR. GENERSDR UALA2013032501877Transmitter · unsecureFOUND FUEL LEAKING FROM NR 2 ENGINE FUEL FLOW TRANSMITTER. RESECURED MOUNTING BOLTS. RAN ENGINE LEAK CHECK GOOD.SDR UALA2013032701976Transceiver · faultedLEFT HF NOT TUNING, NOT RECEIVING, TRANSMITS INTERMITTENTLY. REPLACED LEFT HF TRANSCEIVER, GROUND CHECKED GOOD IAW 23-11-00 & 23-11-03.SDR UALA2013032501847Floorbeam · corrodedCORROSION ON MAIN CABIN FLOORBEAM BS 365, BL 0-RBL 65. REMOVED AND REPLACED FLOORBEAM TEE.SDR UALA2013032701957Skin · dentedDENT 3" FORWARD OF DOOR 2L, 4" BELOW THE SILL. INSPECTED DENT SMOOTH NOT FASTENERS STRIPED INVOLVED SRMS 3 00 01. DENT IS 2"X.062"DEEP, SMOOTH, NO CRACKS GOUGES OR PULLED FASTENERS. WITHIN LIMITS OF SRM 53-00-01.SDR UALA2013032601920Spring · faultyR1 DOOR LOWER FWD HINGE COVER WILL NOT SPRING OUT. REMOVED THE HINGE COVER AND ALL PARTS, REPLACED SPRING .SDR UALA2013032501882Warning Light · illuminatedSTATUS PAGE SHOWS RT ENG PRI CONT MESSAGE AND THE EPCS PAGE SHOWS P HCC-EEC, P 351-19. REF JRH EEC STATIC TEST 2-5-73 EPCS MESSAGES COME BACK AFTER POWER EEC.SDR UALA2013032501881Windshield Wiper · brokenFIRST OFFICERS SIDE WIPER ARM IS BROKEN. REPLACED FIRST OFFICERS WIPER BLADE ASSY PER REF AMM.SDR UALA2013032501861Chiller · inoperativeGALLEY CHILLER INOPERATIVE. REMOVED AND REPLACED GALLEY CHILLER. OPS CHECKED NORMAL.SDR UALA2013032501868Structure · dentedDENT FOUND AT UPPER FUSELAGE BS 651.5 BETWEEN STR 2L-4L FOUND TO BE OUT OF LIMITS PER SRM 53-00 -01 FIG 101 DETAIL III. MAJOR REPAIR ACCOMPLISHED: REPAIR DAMAGE PER ECRA 5331-01699.SDR UALA2013032501839Smoke Detector · miswiredFOUND CB N8 AT P11 POPPED WHEN FIRST CLASS LAV DOOR LATCH SWITCH LOCKED. CONNECTOR D42 CHECKED NO DAMAGE FOUND. FOUND SMOKE DETECTOR WIRES IN FWD LAVATORY INSTALLED INCORRECTLY. INSTALLED AND SECURED WIRES REF WDM 26-14-11, OPS CHECKED GOOD.
Back to Boeing 757-222