Boeing 757-224
Service difficulty reports · 3,824
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757224' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2010041200128Oven · shortedDURING CLIMB, MID GALLEY OVEN 305 BEGAN TO SMOKE WITH BURNING ODOR. REMOVED ALL FOOD ITEMS, REMOVED ALL ELECTRICAL POWER, SMOKE AND ODOR DISSIPATED. CONTINUED FLIGHT WITH OVEN UNPOWERED AND NO ADDITIONAL ABNORMALS WITH OVEN 305 C/B PULLED AND PLACARD INOP RESDR CALA2010040500116Light · damagedFOUND THE EMERGENCY EXIT SLIDE LIGHT AT L3 INOPERATIVE WITH LIGHT ASSEMBLY DAMAGED. REMOVED AND REPLACED EMERGENCY EXIT LIGHT ASSEMBLY REF AMM 33-5 1-06. OPS CHECK GOOD.SDR CALA2010032400099Angle · corrodedSUPPORT TASK. R-2 DOOR Z-ANGLE CORRODED. REMOVED AND REPLACED CORRODED ZEE ANGLE CHORD REFERENCE BOEING DRAWING 143N8328 AND SRM 51-40-02.SDR CALA2010031600081Skin · crackedFWD CARGO DOOR EXTERIOR LOWER CORNER SKIN CRACKED AND WORN. BLENDED OUT DAMAGE & INSTALLED REPAIR DOUBLER ON THE AFT LOWER CORNER OF THE FWD CARGO DOOR SKIN REF SRM 52-30-01 REPAIR 4. INITIATED A DIP TO REINSPECT REPAIR AT A THRESHOLD OF 37,500 TOTAL FLIGHT SDR CALA2010031600080Doubler · damagedEXISTING REPAIR DOUBLER AT APPROXIMATELY STA 320 BETWEEN STRINGERS 22RT AND 23RT HAS SEVERAL DINGS ON THE AFT END. REMOVED EXISTING DOUBLER, CUT OUT ADDITIONAL DAMAGE & INSTALLED NEW REPAIR DOUBLER REF SRM 53-00-01 REPAIR 2. INITIATED A DIP TO HFEC INSP SKINSDR CALA2010031000079Hose · rupturedIMMEDIATELY AFTER TAKEOFF, BOTH QYT MESSAGE AND LIGHT FOR L HYD PRESSURE WAS STILL GOOD. FIVE MINUTES LATER L PRESSURE WENT TO ZERO WITH PWR XFER UNIT STATUS MESSAGE. TEN MINUTES LATER LOST RUDDER RATIO AND L-YAW DAMPER. FOUND RT MAIN GEAR RETRACT ACTUATOR SDR CALA2010030800075Slide · malfunctionedREF NR 4359186, FOUND BOTTLE DISCHARGED BUT SLIDE DID NOT DE PLOY (LT OVERWING). PERFORMED TASK 25-65-00-715-033 OVERWING SLIDE DEPLOY SYSTEM WORKED NORMAL. LUBED ALL HINGES AND LOCKING SYSTEM ON SLIDE DOOR. REF NR 4359186 BOTTLE REPLACED PER AMM 25-65-02.SDR CALA2010030800074Fan · malfunctionedF/A AND PASSENGERS REPORT ELECTRICAL BURNING SMELL IN CABIN (MORE PRONOUNCED IN AFT CABIN). TURNED OFF CABIN LIGHTING (ALL) GALLEY OVENS AND EQUIPMENT, AND INFLIGHT ENTERTAINMENT SYSTEM. T/S AND FOUND CABIN AIR RECIRCULATING FAN VALVE INOP. REMOVED & REPLACSDR CALA2010030800061Floorbeam · corrodedAFT FLOORBEAM STA 1640 FROM LBL 4 TO RBL 4 HEAVY CORROSION. REPAIRED UPPER FLOORBEAM CAP REF SRM 53-00-51 REPAIR 3.SDR CALA2010030800058Floor Support · corrodedFLOOR SUPPORT HAS CORROSION, STA 680, RBL 38, JUST AFT OF THE O/B AFT G2A GALLEY MOUNT. DEPTH OF CORROSION MORE THAN 10 PERCENT MAX ALLOWABLE LIMITS. REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL STA 680, RBL 38 JUST AFT OF THE O/B - AFT G2A GALLEY REF BOEISDR CALA2010022600053Floorbeam · corrodedB757-53-3-0007 FLOORBEAM STA 720 HAS HEAVY CORROSION AT UPPER CAP FROM L2 DOOR THRESHOLD TO R2 DOOR THRESHOLD. REMOVED AND REPLACED UPPER FLOORBEAM CAP AT STA 720 FROM L2 DOOR THRESHOLD TO R2 DOOR THRESHOLD REF B757 SRM 51-40-02 AND EA 5320-01454.SDR CALA2010022600047Wire · disconnectedEMERGENCY LIGHT TEST SWITCH AT L1 DOOR INOP FOUND WIRING DISCONNECTED BEHIND SWITCH. RECONNECTED WIRING, OPS CHECKS GOOD.SDR CALA2010022600038Fastener · shearedLEFT WING I/B FLAP, O/B TRACK, AFT FAIRING (572HB), FWD I/B MOUNT BRACKET HAS SHEARED FASTENERS FOR ATTACHMENT TO LOWER SURFACE OF FLAP. REMOVED FITTING, CUTOUT DAMAGE, INSTALLED FREEZE PLUGS, REPAIR STRAPS AND FILLERS REF ECRA 5750-04299.SDR CALA2010021500032Light · inoperativeEMERGENCY LIGHT AT R2 INOP. R&R R2 EMERGENCY EXIT LIGHT BULB EXTERIOR, REF AMM 33-51-06. ALL EXTERIOR LIGHTS OPS CHECK NORMAL.SDR CALA2010020500027Unknown · odorRECEIVED A LAV SMOKE EICAS MESSAGE. F/A REPORTED, SMELLED SMOKE IN AFT LAV. ON FINAL ALL LAVS SMOKE DETECTORS SOUNDED. AFTER LANDING DETECTORS STOPPED WHEN LAV OPENED. FOUND EMPLOYEE NUMBER REPORTING THIS DISCREPANCY INACTIVE. INSPECTED GENERAL AREA OF AFSDR CALA2010020200021Frame · corrodedCORROSION ON BOTTOM SIDE OF INNER (UPPER) CHORD, AFT CARGO DOOR OPENING, FWD FRAME, LOWER CORNER, AT STA 1380, JUST O/B OF CARGO TIE DOWN PLATE. REF DWG 146N8511 FRAME 3 OF 7, BL 26, WL 148. REPAIRED CARGO FRAME ASSY STA 1380 INNER CORD S26R-S27R REF ECR A 5SDR CALA2010012500017Skin · corrodedBS 984 RIGHT UPPER SURFACE OF CENTER TANK HAS EXFOLIATION UNDER STUB BEAM. PERFORMED REPAIR TO CORROSION AT BS 984 RIGHT UPPER SURFACE OF CENTER TANK UNDER STUB BEAM COMPLYING WITH STEPS 1-12 OF EC/RA 5730-02583.SDR CALA2010010400005Shutoff Valve · leakingCREW 02 PRESS LOW SERVICED CREW 02 FOUND SHUTOFF VALVE LEAKING AND BENT. REMOVED AND REPLACED CREW 02 BOTTLE REF AMM 35-11-00, A/C OK TO CONTINUE. ROTABLE PARTS CHANGE WAS INDICATED - TT 1384230 S/N OFF 06820 BOTTLE, OXY, AI OFF 29-3511-9-9001 8620 ON 29-3SDR CALA2010010400004Light · inoperativeEXTERIOR EMERGENCY EXIT LIGHT BEHIND L3 DOOR IS INOPERATIVE. REMOVED AND REPLACED EXTERIOR EMERGENCY EXIT LIGHT BEHIND L3 DOOR REF AMM 33-51-01.SDR CALA2010010400001Charger · inoperativeCOACH CABIN EMERGENCY LIGHTS AISLE PATH ROWS 15-25 NOT WORKING DURING TEST T/S FOUND M10699 BAD AT RT ROW 22. REMOVED AND REPLACED CHARGER AND BATTERY. OPS CHECK NORMAL AT THIS TIME.SDR CALA2009122800772Battery · dischargedAFT F/A FLASHLIGHT BATTERY DISCHARGED. REPLACED EMERGENCY FLASHLIGHT BATTERY. OPS CHECK NORMAL.SDR CALA2009122800771Light · inoperativeFLOOR LEVEL EMERGENCY EXIT SIGN AT LEFT FWD EMERGENCY OVERWING EXIT HAS BULB INOPERATIVE. REMOVED AND REPLACED BULBS IN EXIT SIGN, OPS CHECK GOOD IAW AMM 33-51-10.SDR CALA2009122800770Bottle · defectiveFOUND EMERGENCY SLIDE RT BOTTLE PRESSURE TEST INOPERATIVE. REMOVED AND REPLACED RT EMERGENCY SLIDE PRESSURE BOTTLE AS PER M/M CHAP 25-65-02, OPS CHECKS GOOD. ROTABLE PARTS CHANGE WAS INDICATED - TT 1265237 S/N OFF 05379 BOTTLE, ESCAPE OFF 19-2565-9-9007 537SDR CALA2009122800764Floorbeam · corrodedCABIN FLOORBEAM UPPER FRONT FLANGE UNDER SIDE HAS HEAVY CORROSION AT STA 1681, LBL 48. REPAIRED DAMAGED FLOORBEAM STA 1681 LBL 48 REF ECRA 5310-05066.SDR CALA2009122800763Floorbeam · corrodedCABIN FLOORBEAM AT STA 1681, LBL 5 HAS CORROSION ON FWD EDGE LOWER SURFACE, SEEN FROM BELOW. REPAIRED DAMAGED FLOORBEAM STA 1681, LBL 5 REF ECRA 5310-05066.SDR CALA2009121600726Power Supply · inoperativeOVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE WHEN TESTED LOCATED CENTER AISLE ENTRYWAY TO COCKPIT. REPLACED PWR SUPPLY LOCATED AFT OF AND ABOVE CTR AISLE WAY TO COCKPIT. OPS CHECKS GOOD. P/N 2012-1 M/M 33-51-07.SDR CALA2009121600721Charger · inoperativeROW 21 LT OVERHEAD BULKHEAD EMERGENCY LIGHT INOPERATIVE. FOUND BATTERY CHARGER (POWER SUPPLY) DEFECTIVE, REMOVED AND REPLACED, OPS CHECK NORMAL, REF AMM 33-51-07.SDR CALA2009121600725Light · inoperativeEXTERIOR EMERGENCY EXIT SLIDE LIGHT OUT AT L2 DOOR. REPLACED LAMP AT L2 MAIN DOOR EMERGENCY EXIT EXTERIOR SLIDE LIGHT. OPS CHECKS GOOD.SDR CALA2009121600724Battery Pack · dischargedEMERGENCY AISLE LIGHTS AT ROWS 7 THRU 14 INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT SEAT 9DEF. OPS CHECK GOOD.SDR CALA2009121600723Battery Pack · dischargedEMERGENCY FLASHLIGHT AT DOOR 1L INOPERATIVE. REPLACED FLASHLIGHT BATTERY AND SAFETY STRAP, OK TO CONTINUE.SDR CALA2009121600722Charger · inoperativeEMERGENCY LIGHTS INOPERATIVE AT L1 MAIN DOOR EXTERIOR. PATH LIGHTS BUSINESS 1ST, BULL NOSE 1, 3 AND 4AB. REPLACED BATTERY PACK AND PWR SUPPLY, OPS CHECKS GOOD AT EMERGENCY LIGHTS AS NOTED ABOVE. PWR SUPPLY REPLACED M731 PER W/D 33-51-01.SDR CALA2009121600720Battery Pack · dischargedROW 7 TO ROW 14, EMERGENCY LIGHTS ON SEATS INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY PACK ABOVE SEAT 9DEF FOR ROWS 7 TO 14. REF AMM 33-51-07, OPS CHECKS GOOD.SDR CALA2009121600719Light · inoperativeTHE 34D EMERGENCY EXIT LIGHT INOPERATIVE. BULB REPLACED, NOW SATISFACTORY P/N 1317.SDR CALA2009121600718Light · inoperativeR2 DOOR EMERGENCY LIGHT EXTERIOR INOPERATIVE. REMOVED AND REPLACED BULB AT R2 DOOR, OPS CHECK GOOD IAW AMM 33-51-06.SDR CALA2009121600717Battery Pack · dischargedL2 DOOR EMERGENCY EXTERIOR LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK IN CHARGER M00737, OPS CHECK GOOD, IAW AMM 33-51-07.SDR CALA2009121600716Battery Pack · dischargedLAST FOUR EMERGENCY EXIT LIGHTS ARE INOPERATIVE. REPLACED BOTH AFT BATTERY PACK AND AFT GALLEY EMERGENCY LIGHTS SWITCH. PER W/D 33-51-15, TESTED LIGHTS, OPS CHECKS GOOD.SDR CALA2009120800698Floorbeam · corrodedCABIN FLOORBEAM STA 1640 RBL 6 TO LBL 6 HAS HEAVY CORROSION. CORRODED AREA WAS FOUND TO BE BEYOND ALLOWABLE LIMITS. REMOVED DAMAGED AREA ON FLOORBEAM, FABRICATED AND INSTALLED REPAIR SECTION OF UPPER CHORD AND ALL REQUIRED ATTACH PARTS PER SRM 53-00-51 REPAISDR CALA2009113000692Power Supply · discharged(MULT-33-3-0004) EMERGENCY LIGHTS ASSOCIATED WITH POWER SUPPLY M730 INOP IN FWD CABIN AREA. REMOVED AND REPLACED M730 EMERGENCY LIGHT POWER SUPPLY REF MM 33-51-07. OPS CHECKS NORMAL.SDR CALA2009112000685Gcu · malfunctionedLT AND RT UTILITY BUSES TRIPPED FOR ABOUT 3-4 SECONDS IN FLIGHT. ALSO LT AND RT UTILITY BUS MESSAGE APPEARED ON EICAS. UTILITY BUSES RESET THEMSELVES. GALLEY POWER AND VIDEO TURNED OFF. T/S PER MM 24-22-00, REMOVED AND REPLACED LT AND RT GCU AND BPCU AS PESDR CALA2009110900680Skin · crackedR-4 DOOR LIGHTENING HOLE NEAR VERTICAL ADJUSTMENT TORQUE TUBE HAS CRACK. ACCOMPLISHED REPAIR PER ECRA 5210-02105.SDR CALA2009110900677Psu · malfunctionedRAPID DE-PRESSURIZATION OF CABIN CAUSED PASSENGER O2 MASKS TO DEPLOY, 51 SEAT ROWS COULD NOT ACTIVATE O2 GENERATORS, MASK LANYARD JAMMED AND WOULD NOT PULL FIRING PIN. THE ACFT LOST PRESSURIZATION DURING CRUISE FLIGHT WHEN THE LEFT PACK FAILED. RT PACK WAS OSDR CALA2009102300647Oven · smokeOVEN 413 SMOKES WHEN IN USE. REMOVED AND REPLACED OVEN 413, GROUND OPS CHECK NORMAL AT THIS TIME. OVEN, LARGE, SG OFF 99-2533-9-0002 SN 0370, ON 99-2533-9-0002 SN 0165.SDR CALA2009102200638Light · inoperativeL1 EXTERIOR EMERGENCY EXIT LIGHT IS INOPERATIVE. RELAMPED L1 EMERGENCY EXIT LIGHT PER AMM 33-51-06. SYSTEM OP CHECKS NORMAL.SDR CALA2009102000635Charger · inoperativeDURING NR 3 SERVICE CHECK INSPECTION FOUND CABIN EMERGENCY LIGHTS ROW 15-24 INOPERATIVE. REPLACED EMERGENCY LIGHT BATTERY CHARGER, OPS CHECK NORMAL.SDR CALA2009101600630Floorbeam · misrepairedSTATION 720 FLOORBEAM APPROXIMATELY LBL 45 PREVIOUS REPAIR IMPROPERLY ACCOMPLISHED. REMOVED AND REPLACED REPAIR PER B757 SRM 53-00-51.SDR CALA2009101500625Floorbeam · corrodedSTATION 1640 T-CAP ON FLOORBEAM HAS CORROSION NEAR BUTTLINE 0 FOUND CORROSION OUT OF LIMITS. REPAIRED T-CAP PER SRM 53-00-51 REPAIR 3.SDR CALA2009101300622Light · inoperativeL-4 MAIN DOOR EMERGENCY EXIT EXTERIOR SLIDE LIGHT IS OUT. REPLACED LAMP AT LT L-4 MAIN DOOR SLIDE EMERGENCY EXIT LIGHT, OPS CHECKS GOOD.SDR CALA2009100900612Light · inoperativeEMERGENCY EXIT LIGHT ON EXTERIOR OF AFT CARGO DOOR IS OUT. REPLACED LAMP AT EMERGENCY EXIT LIGHT ON AFT CARGO DOOR. OPS CHECKS GOOD.SDR CALA2009100900611Light · inoperativeEMERGENCY EXIT LIGHT ON OVERHEAD LEFT OVERWING EXIT DOORS MORE THAN 50 PERCENT OF LIGHTS INOPERATIVE. REPLACED 15 LAMPS AT EMERGENCY EXIT LIGHT ASSY WHICH WERE BURNED OUT AT LEFT OVERWING EMERGENCY EXIT OVERHEAD. OPS CHECKS GOOD.SDR CALA2009100700609Light · inoperativeL2 AND R1 DOOR EXTERIOR EMERGENCY LIGHTS ARE INOPERATIVE. RELAMPED EXTERIOR LIGHTS, OPERATIONAL CHECKS GOOD.
Back to Boeing 757-224