Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2017090221252Shutoff Valve · inoperativeEMERGENCY DECLARED, DUIRING DESCENT TO FL 320, THE RIGHT PACK PRESSURE STARTED TO FLUCTUATE SHORTLY AFTER THE RT ENGINE BLEED EICAS INDICATION. THE CABIN ALTITUDE CLIMBED ABOVE 10,000 AND DESCENDED. REPLACED THE RT PRSOV IAW MM 36-11-09-002-017-001. REPLACSDR IPXA2017090621417Support Angle · corrodedINSPECTION TYPE: C10, RT AFT WING TO BODY FAIRING HAS CORROSION ON OUTER SUPPORT ANGLE AT BS 1180. REPLACED THE SUPPORT ANGLE.SDR IPXA2017091121600Support · corrodedINSPECTION TYPE: C-10, RT AFT WING TO BODY FAIRING SUPPORT HAS CORROSION, BS 1240. REPAIRED THE SUPPORT IAW SRM 51-70-12.SDR IPXA2017082320885O-Ring · leakingEMERGENCY DECLARED, THE LEFT HYDRAULIC RESEVOIR QTY LOW. FOUND A HYD LEAK ON FLAP STALL DEPRESSURIZATION MODULE ASSY CONNECTOR. R & R THE O-RING IAW AMM 20-10-19-404-001. SERVICED THE LT HYD SYS IAW AMM 12-12-01-301. LEAK CHECKED GOOD. NO LEAKS NOTED IAW AMSDR IPXA2017082220830Bracket · detachedINSPECTION TYPE: ASE, CAPTAIN'S EVAS MOUNT BRACKET SEPARATED FROM MOUNT HOLES. SECURED AND INSTALLED THE EVAS SYSTEM MOUNTING BRACKET IAW EO B757-2560-45127-H, APPX D, AND AMM 25-69-00.SDR IPXA2017081820672Actuator · trippedEMERGENCY DECLARED, ON APPROACH WHEN SELECTING FLAPS TO 1 ON APPROACH RECEIVED A LE SLAT DISAGREE MESSAGE APPEARED AS WELL AS THE LEADING EDGE LIGHT. THE FLAP NEEDLE WAS BETWEEN UP & 1. TROUBLESHOT AND FOUND THE NR 5 SLAT INBOARD GEARED ROTARY ACTUATOR TRIPPSDR IPXA2017080920322Controller · malfunctionedCABIN ALTITUDE AUTO 2 MESSAGE DISPLAYED. LOSS OF CABIN PRESSUE. EMERGENCY DECLARED. REPLACED THE NR 2 CABIN PRESSURE CONTROLLER IAW FIM 21-30-00-815-803, AND AMM 21-31-02-0401. OPS NORMAL.SDR IPXA2017080920323Indication Sys · malfunctionedTE FLAP DISAGREE ON FLAPS 1 SELECTION. FLAP INDICATOR BETWEEN 0 AND 1. REF SPEED 165 UPON LANDING. EMERGENCY DECLARED, PERFORMED A BITE AND T/E FLAP SYSTEM OPERATION IAW MM 27-51-00-201-862-004, AND AMM 27-51-01. NO FAULTS NOTED AT THIS TIME. CYCLED FLAP TWSDR IPXA2017080720249Floor Support · dentedAFT LOWER CARGO BAY FLOOR SUPPORT HAS DENT DAMAGE AT BS 1436, RBL 7. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02. DRILLED, PAINTED & INSTALLED NUTPLATES IAW SRM 51-40-02, & AMM 51-21-00.SDR IPXA2017080720206Pitot Tube · contaminatedAIRSPEED UNRELIABLE AFTER TAKEOFF, MESSAGES FOR MACH/SPEED TRIM IAS DISAGREE, RUDDER RATIO CAPTAIN`S INSTRUMENTS UNRELIABLE. PURGED CAPTAIN`S PITOT PROBE AND LINES FOUND INSECT CONTAMINATION. COMPLIED WITH PITOT SYS PRESSURIZATION TEST, AIRSPEEED INDICATOR SDR IPXA2017080920303Panel · corrodedINSPECTION TYPE: C-10, PANEL 198KR HAS EVIDENCE OF LIGHT SURFACE CORROSION IN MULTIPLE AREAS. FABRICATED A NEW PANEL IAW DWG 149N7720 REV DSDR IPXA2017080420128Light · inoperativeREF TO T/C NR 25-069-00 AND WAN 2601141. CAPTS EVAS LIGHT WILL NOT TURN ON REMOVED EVAS BOX FROM ITS HOLDER. TESTED PER AMM 25-69-00-200. OPS CHECKS GOOD. OK FOR SERVICE.SDR IPXA2017081220420Intercostal · corrodedINSPECTION TYPE: C, LT FWD WING TO BODY FAIRING STRUTURES BS 900, LBL 31 INTERCOSTAL HAS CORROSION AND MISSING ONE NUTPLATE.REMOVED CORROSION IAW SRM 51-10-02-0G. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-71-1A-1 FIG 101 DETAIL IX. FABRICATED NEW INTERCOSSDR IPXA2017081820671Floorbeam · corrodedINSPECTION TYPE: SEG2, AT BS 900 FLOORBEAM HAS CORROSION RBL 6 - LBL 50. REMOVED DAMAGED SECTION OF TEE AND FABRICATED REPAIR IAW SRM 51-70-12-0G. INSTALLED THE REPAIR IAW SRM 51-70-12-0G, AND SRM 51-40-02-0G.SDR IPXA2017080920307Floor Panel · delaminatedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017080920310Floor Panel · delaminatedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017082020719Structure · corrodedINSPECTION TYPE: SEG, RT WING TO BODY FAIRING STRUCTURE UNDER PANEL 198KR HAS CORROSION ON OUTSIDE SURFACE AND ALSO THE STRUCTURE IS SEPERATING AT FWD AND AFT FASTENER HOLES. REPAIRED THE RT WING TO BODY FAIRING STRUCTURE PANEL IAW SRM 51-70-12-0G.SDR IPXA2017081220419Support · corrodedINSPECTION TYPE: C, LT MLG WW PANEL 197AL SUPPORT CORRODED. REMOVED THE DAMAGE IAW SRM 51-10-02-0G. SUPPORT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-71-1A-1 FIG 101 DETAIL IX. FABRICATED NEW SUPPORT AND INSTALLED IAW SRM 51-40-02-0G.SDR IPXA2017080220059Fseu · malfunctionedR & R FSEV NR 1 DUE TO LE SLAT DISAGREE. COMPLIED WITH FIM 27-81-00-815-803. NO FAULTS. R & R FSEU NR 1 IAW MM 27-51-01/201 AND OPS CHECKED IAW MM 27-81-00-715-001. CHECKED GOOD.SDR IPXA2017081520569Wedge · delaminatedINSPECTION TYPE: SEG 2, NR 2 SLAT WEDGE HAS A 3 INCH DIAMETER DENT. REPAIRED IAW EA 757-5743-27-A2268 AND SRM 51-70-10-2R REP 4 5.SDR IPXA2017081020339Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XFF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017081020338Floor Panel · puncturedINSPECTION TYPE: CM, CARGO DECK FLOOR PANEL 241XCF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017081020337Floor Panel · damagedINSPECTION TYPE: CM, CARGO DECK FLOOR PANEL 241XDF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017080920317Floor Panel · delaminatedINSPECTION TYPE: SEG2, MCD FLOOR PANEL 241XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017080920315Floor Panel · damagedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 242XHF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-KSDR IPXA2017071719403Slat System · malfunctionedLE SLAT DISAGREE DISPLAYED WITH THE FLAP LEVER IN 1 BOTH FLAP POINTERS INDICATE 1/2 FLAP EXTEND SPEED WAS APPROX 237 FOR SELECTION FROM UP TO 1 POSITION. EMERGENCY DECLARED. OPS SYSTEM IAW FIM 27-81-00-815-803, PERFORMED PLAPS TO 1 TO 25 AND BACK TO 0 4 TIMESDR IPXA2017071419283Bulb · inoperativeEMERGENCY LIGHT HAS THREE INOPERATIVE BULBS. INSTALLED NEW BULBS IAW AMM 33-51-01-2SDR IPXA2017072219610Skin · dentedINSPECTION TYPE: C-12, NR 2 PYLON INBD SIDE SKIN PANEL DENTED. REPAIRED IAW EO B757-5430-64999-ASDR IPXA2017071219231Evas Unit · damagedLEFT EVAS DAMAGED. R & R THE EVAS IAW AMM 25-69-00. OP CHECKED GOOD.SDR IPXA2017071419292Slat System · malfunctionedLEADING EDGE SLAT DISAGREE ON FLAP RETRACTION. RAN QRH PROCEDURE RETRACTED IN ALTERNATE. EMERGENCY DECLARED. DISAGREE WAS BETWEEN 1 AND UPC/W FIM 27-81-00-815-803 NO EXISTING FAULTS ON FSEU'S, NO 60 DAY HISTORY OPS CKS GOOD IN NORMAL AND ALT UP AND DOWN OK FOSDR IPXA2017071319248Bushing · corrodedINSPECTION TYPE: SEG2, NR 2 PYLON TWO UPPER LINK BUSHINGS AT THE FWD END CORRODED. REMOVED AND REPLACED.SDR IPXA2017071019144Power Supply · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-51-07-201. OPS CHECKED GOOD.SDR IPXA2017071819464Floor Panel · puncturedINSPECTION TYPE:SEG4, MAIN DECK FLOOR PANEL 242XFF IS PUNCTURED AT TWO SPOTS. FABRICATED NEW FLOOR PANEL 252XFF PER SREO B757-5320-9692-K COMPLETED SERVICE DIFFICULTY REPORT SDR FORM 52-19-051 PER GMM 03.16.01.01.SDR IPXA2017071619338Structure · corrodedINSPECTION TYPE: C12, RT ELEVATOR WING TIP T/E WEDGE CORRODED. REPAIRED THE ELEVATOR T/E WEDGE IAW REO-G20920.SDR IPXA2017072419708Intercostal · corrodedINSPECTION TYPE: SEG4, LT WING TO BODY FAIRING STRUCTURE BS 900 LBL 31 INTERCOSTAL HAS CORROSION. REPAIRED DAMAGED IAW SRM 51-70-12.SDR IPXA2017070719033Altimeter · malfunctionedINSPECTION TYPE: PS-10140Z, BLOCK TURN BACK TO AFTER COMPLETING THE LEFT ENGINE START THE LEFT A/S IN, ALTIMETER, VSI ALL WENT INOP, ALONG WITH LEFT TRASPONDER. SWITCHING TO ALT POS ON AIR DATA CORRECTED PROBLEM. AFTER BLOCKIN AND SWITCH TO APU ALL INSTUMENSDR IPXA2017072219611Door Frame · gougedINSPECTION TYPE: C-12, FWD NOSE AREA DOOR 113AL FWD CUTOUT FRAME GOUGED. REPAIRED IAW EO B757-5310-64993-ASDR IPXA2017071319261Structure · corrodedINSPECTION TYPE: C-12, LEFT ELEVATOR TIP CORRODED, FOUND AFTER REMOVAL. REMOVED CORROSION IAW REO-620929.SDR IPXA2017071919497Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL IS PUNCTURED ON BOTTOM SIDE. FABBED PNL 231XFF FROM A402H-48X144 BAT 3119029 PER SREO B757-5320-9692-K.SDR IPXA2017071919496Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XJF IS PUNCTURED ON BOTTOM SIDE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071919495Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XDF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071919494Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XGF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071819466Floor Panel · damagedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XDF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071819465Floor Panel · puncturedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XHF IS PUNCTURED ON UPPER SURFACE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071819463Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XHF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017071319246Skin · dentedINSPECTION TYPE: C-12, LEFT HORIZONATL STAB UPPER SURFACE INBD L/E DENTED. REPAIRED THE DAMAGE IAW 51-70-10, REPAIR 2, AND 51-70-10-2R.SDR IPXA2017071319244Skin · dentedINSPECTION TYPE:C-12, LEFT HORIZONTAL STAB UPPER SURFACE INBD L/E DENTED. REPAIRED THE DAMAGE IAW 51-70-10, REPAIR 2, AND 51-70-10-2RSDR IPXA2017062918758Liner · corrodedLEFT ENGINE LP COMPRESSOR FROM CASE HAS NUMEROUS AREAS OF CORROSION UNDER ROTOR PATH LINING. REMOVED CORROSION AND FOUND A LARGE AREA OUT OF LIMITS IAW AMM 72-34-10-300-80.SDR IPXA2017072019564Wedge · chafedINSPECTION TYPE: C-12, LEFT WING NR 3 SLAT LOWER TRAILING EDGE CHAFED. REPAIRED THE DAMAGE IAW EO B757-5750-64988-A AND REO-G20909, REV IR.SDR IPXA2017062918745Power Supply · inoperativeEMERGENCY EXIT EXTERNAL EGRESS LIGHT INOPERATIVE. R & R THE POWER SUPPLY M731. SYS CHECKED OK, IAW AMM 33-51-07.
Back to Boeing 757-24APF