INSPECTION TYPE: SEG2, AT BS 900 FLOORBEAM HAS CORROSION RBL 6 - LBL 50. REMOVED DAMAGED SECTION OF TEE AND FABRICATED REPAIR IAW SRM 51-70-12-0G. INSTALLED THE REPAIR IAW SRM 51-70-12-0G, AND SRM 51-40-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: SEG2, AT BS 900 FLOORBEAM HAS CORROSION RBL 6 - LBL 50. REMOVED DAMAGED SECTION OF TEE AND FABRICATED REPAIR IAW SRM 51-70-12-0G. INSTALLED THE REPAIR IAW SRM 51-70-12-0G, AND SRM 51-40-02-0G.