Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015081392328Lamp · inoperativeFIVE LAMPS INOPERATIVE IN EMERGENCY EXIT SIGN. REPLACED THE LAMPS IN EMERGENCY EXIT SIGN, IAW AMM 33-51-01.SDR IPXA2015081492332Strap · brokenELT MOUNT STRAP BROKEN, R & R 406 ELT MOUNT STRAP IAW MM 25-60-00-401.SDR IPXA2015081592377Floorboard · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBOARD 242XHF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592376Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XHF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015081592375Floorboard · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBOARD 242XJF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592374Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOORBOARD 241XJF DAMAGED. FABRICATED MCD FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592373Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOORBOARD 242XCF DAMAGED . FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592372Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOORBOARD DAMAGED 241XDF. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015081592370Floor Panel · damagedINSPECTION TYPE:C, MAIN CARGO DECK FLOORBOARD DAMAGED 241XCF. FABRICATED MCD FLOOR PANEL 241XCF, PN 144N5361-54 IAW SREO B757-5320-9692-H FROM A402H-48X144 BATCH NR 2749199.SDR IPXA2015082892835Stringer · corrodedINSPECTION TYPE: C-12, AFT CARGO STRINGER UPPER FLANGE CORRODED BS 1450, STR 29L. REPAIRED THE STRINGER IAW REO-G19145, REV A.SDR IPXA2015082792800Skin · dentedINSPECTION TYPE:C-12, FWD RT EXTERIOR FUSELAGE SKIN DENT BS 314 STRINGER 16R. REPAIRED AREA IAW REO-G19126, REV B AND EO B757-5330-58497-A.SDR IPXA2015082592726Frame · dentedINSPECTION TYPE:C-12, AFT CARGO BAY LT SIDE BS 1340, STRINGER 26L, FRAME DENTED. REPAIRED THE FRAME IAW SRM 53-00-07-2R-5.SDR IPXA2015081992520Skin · dentedINSPECTION TYPE:C-12, AFT RT EXTERIOR FUSELAGE SKIN DENT BS 1639 S18R. REMOVED DAMAGE AND INSTALLED REPAIR IAW SRM 53-00-01-2R-3.SDR IPXA2015082392621Seal Depressor · dentedINSPECTION TYPE: C9, AFT CARGO DOOR NEAR THE AFT UPPER DOOR STOP FRAME DENTED. R & R THE SEAL DEPRESSOR IAW SRM 51-40-02.SDR IPXA2015082192549Skin · dentedINSPECTION TYPE:C-12, AFT LOWER CARGO DOOR, LOWER AFT CORNER DENTED, FOUND TO BE OUT OF LIMITS, REPLACED WITH NEW SERVICEABLE -4 CORNER.SDR IPXA2015082892811Skin · dentedINSPECTION TYPE:C-12, NR 3 SLAT DENT NR 16 FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY. REPAIRED NR 3 SLAT UPPER SURFACE DENT IAW REO-G19140 AND SRM 51-70-10.SDR IPXA2015082892810Wedge · dentedINSPECTION TYPE:C-1234, SLAT DENT NR 1 FOUND TO BE OUT OF LIMITS DUE TO DELAMINATION. REPAIRED UPPER SKIN NOTED AREA IAW SRM 51-70-10 AND REO-19141, REV IR.SDR IPXA2015091593569Floor Support · dentedINSPECTION TYPE:C-17, AFT CARGO FLOOR SUPPORT HAS NUMEROUS DENTS BS 1360-1390, LBL 16.10. REMOVED AND REPLACED WITH NEW A FLOOR SUPPORT IAW DWG 146N5390, REV D.SDR IPXA2015082792803Skin · dentedINSPECTION TYPE:C-9, AFT FUSELAGE EXTERNAL SKIN DENTED APPROX 36" ABOVE AFT RT CORNER OF APU CUTOUT. INSTALL INTERIM REPAIR IAW SRM 51-70-10-2R, REPAIR 2 AND REPAIR GENERAL PARA. 5.0, 3.SDR IPXA2015080391924D-Ring · missingSAFETY HARNESS MISSING D-RING, CARBINER, FROM QTY 2 HARNESS NEAR CREW DOOR, REPLACED D-RINGS IAW MM 25-61, QTY 2.SDR IPXA2015081592369Frame · dentedINSPECTION TYPE:C, FWD CARGO FRAME AT SLOPING AREA RT BS 680 INNER CHORD HAS DENT REPAIRED DAMAGE IAW SRM 53-00-07-2R, REPAIR 5, TABLE 3.SDR IPXA2015081392319Panel · corrodedINSPECTION TYPE :C, AFT CARGO BS 1200-1310, RT SIDE PANEL CORRODED. R & R AFT CARGO SIDE PANEL IAW SRM 51-40-02-0G.SDR IPXA2015081192256Intercostal · corrodedINSPECTION TYPE:C, AFT CARGO, BS 1400-1420, LBL 2.9 INTERCOSTAL CORRODED. R & R INTERCOASTAL, PN:146N5425U19 WITH BACR15FV6, BATCH 0001771118, BACR15FT6, BATCH 0002699949 AND BACB130MY6, BATCH 0002779208 IAW DWG 146N145399 AND 146N3300 AND IAW SRM 51-40-02.SDR IPXA2015080792126Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XJFS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SR EO B757-5320-9692H.SDR IPXA2015080792125Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SR EO B757-5320-9692H.SDR IPXA2015072991740Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 232XJF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991739Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 231XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991738Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK CARGO FLOORBOARD 232XCF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991737Floorboard · damagedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 231XSF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991736Floor Panel · delaminatedINSPECTION TYPE:C, MAIN CARGO FLOOR PANEL 231XCF FOUND DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B7575320-9692H.SDR IPXA2015081192271Floor Panel · corrodedINSPECTION TYPE:C, FWD CARGO FLOOR PANEL 121BF HAS CHAFE MARKS/CORROSION ALSO INCLUDING UNDER AND AROUND THE MBA SYSTEM. BLENDED CHAFE MARKS AND CORROSION ON FWD CARGO FLOOR PANEL 121BF, ORG MAT=0.071, MAT REMOVED=0.011 MAT REM=0.0606 USING TR17809. FOUND TOSDR IPXA2015072891654Eec · malfunctionedFLAMES SHOOTING OUT OF LT ENGINE DURING START REPORTED BY A MECHANIC. CREW REPORTED NO ABNORMAL INDICATIONS DURING ENGINE START. R & R LT ENGINE ELECTRONIC ENGINE CONTROL MM 73-21-04-024-609-P00, TEST NR 7 AND NR 3 BOTH CHECK GOOD. REF MM 71-00-00, IPC 73-2SDR IPXA2015080792127Floor Panel · damagedINSPECTION TYPE: C, ELECTRICAL EQUIPMENT CENTER FLOOR PANEL 119AF HAS TORN FASTENER HOLES. FABRICATED A NEW FLOOR PANEL.SDR IPXA2015073191792Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK CARGO FLOOR PANEL 241XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191791Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK CARGO FLOOR PANEL 242XCF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191790Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK CARGO FLOOR PANEL 242XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191789Floor Panel · delaminatedINSPECTION TYPE: C, MCD FLOOR PANEL 241XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191788Floor Panel · damagedINSPECTION TYPE :C, MAIN DECK CARGO FLOOR PANEL 241XHF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015073191787Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK CARGO FLOOR PANEL 242XLF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015081892490Casting · corrodedINSPECTION TYPE:C, CORROSION ON LT ELEVATOR LOWER OTBD SKIN SURFACE AT TIP CAP. REMOVED DAMAGED TIP CASTING IAW SRM 51-40-02-0G, FABRICATED SPLICE PLATES IAW DWG 183N2007, FROM 6061-0, .063B, HEAT TREAT TO T-4 WELDED TIP CASTING IAW DWG 183N2902 ON VT MAE TRSDR IPXA2015081892489Casting · corrodedINSPECTION TYPE:C, CORROSION ON RT ELEVATOR LOWER OTBD SKIN SURFACE AT TIP CAP. REMOVED DAMAGED TIP CASTING IAW SRM 51-40-02-0G FABRICATED SPLICE PLATES IAW DWG 183N2007, FROM 6061-0 0.063B, HEAT TREAT TO T-4 WELDED TIP CASTING IAW 183N2902 VTMAE TRAVELER T1SDR IPXA2015072391483Bulb · inoperativeEMERGENCY LIGHT HAS FIVE INOPERATIVE BULBS. REPLACED THE BULBS IN THE EMERGENCY LIGHT IAW AMM 33-51-01-2.SDR IPXA2015072291422Strap · corrodedINSPECTION TYPE:C, APU INLET STRAP,CORRODED.SDR IPXA2015072291421Angle · corrodedINSPECTION TYPE:C, APU INLET ANGLE CORRODED.SDR IPXA2015072291420Angle · corrodedINSPECTION TYPE:C, APU INLET ANGLE CORRODED.SDR IPXA2015072191359Sensor · malfunctionedLEFT FWD ENTRY DOOR LIGHT ILLUMINATED. R & R IAW MM 52-71-00, SENSOR. OPS CHECKS NORMAL.SDR IPXA2015072991702Floor Panel · damagedINSPECTION TYPE: C, MCD FLOOR PANEL 232XYF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA2015072991701Floor Panel · damagedINSPECTION TYPE: C, MCD FLOOR PANEL 241XBF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015072891687Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 232XSF HAS EDGE DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015072191352Skin · dentedSKIN DENTED AND GOUGED AT BS 460 BELOW STR 16 LT, INSTALLED DOUBLER REPAIR. REPAIR IAW EO B757-5330-57237-C.
Back to Boeing 757-24APF