Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015072991720Floorboard · damagedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 231XLF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072991745Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XSF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5230-9692H.SDR IPXA2015072991741Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XCF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072891682Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XXF HAS EDGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891680Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 242XJF HAS EDGE DAMAGE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891679Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 231XRF HAS EDGE DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891678Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XQF HAS EDGE DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891677Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XHF HAS EDGE DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891686Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 252XLF HAS EDGE DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072891684Floorboard · damagedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 231XUF HAS EDGE DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO 757-5320-9692-H.SDR IPXA2015072891683Floorboard · damagedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 232XWF HAS EDGE DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072091345Battery Pack · inoperativeEMERGENCY LIGHT DOES NOT STAY ON DURING TEST. R & R EMERGENCY LIGHT BATTERY PACK IAW MM 33-51-07, OPS CHECK NORMAL.SDR IPXA2015072991703Floor Support · corrodedINSPECTION TYPE:C, MAIN DECK CARGO FLOOR BETWEEN BS 480-500, LBL 38 INTERCOASTAL UPPER SURFACE AROUND NUTPLATES HOLES HAS CORROSION. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-04-1A-1, FIG 101. FABRICATED A NEW PART IAW DWG 284N1020.SDR IPXA2015071891254Bulb · inoperativeEMERGENCY EXIT LIGHT HAS TEN INOPERATIVE BULBS. R & R THE 10 INOPERATIVE BULBS IN THE EMERGENCY LIGHT IAW AMM 33-51-01-2.SDR IPXA2015071691197Pin · shearedINSPECTION TYPE: IN, CAPTAIN`S NR 2 WINDOW CRANK HANDLE PIN SHEARED. R & R THE PIN IAW AMM 56-11-04-404-013. OPS CHECKED GOOD.SDR IPXA2015073191815Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 252XTF FOUND DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015073091776Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 231XAF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2015073091773Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 232XBF DELAMINATED, FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072991744Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 251XJF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991743Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 221XBF FOUND DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA2015072991742Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 232XGF FOUND DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5230-9692H.SDR IPXA2015072891692Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 222XAF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891691Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK CARGO FLOORBOARD 221XAF DELMINATED. FABRICATED MCD FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891690Floorboard · delaminatedINSPECTION TYPE:CMAIN DECK FLOORBOARD 221XCF DELAMINATED. FABRICATED MCD FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891689Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 231XBF DELAMINATED. FABRICATED MCD FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015072891688Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 232XAF DELAMINATED. FABRICATED MCD FLOOR PANEL 232XAF, PN 143N5457-5 IAW SREO B757-5320-9692-H FROM A402H-48X144, BATCH 2749199.SDR IPXA2015072991700Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK CARGO FLOORBOARD 222XCF DELAMINATED. FABRICATED MCD FLOOR PANEL 222XCF, PN 141N5410-20 IAW SREO B757-5320-9692H FROM A402H-48 X 144 BATCH 2749199.SDR IPXA2015072991699Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK CARGO FLOORBOARD 222XBF DELAMINATED. FABRICATED MCD FLOOR PANEL 222XBF, PN 141N5410-19 IAW SREO B757-5320-9692-H FROM A402H-48X144 BATCH 2749199.SDR IPXA2015071591184Battery Pack · no testEMERGENCY LIGHTS WILL NOT TEST. REPLACED BATTERY PACK IAW AMM 33-51-07-902-001.SDR IPXA2015070790928Smoke Goggles · crackedOBSERVERS SMOKE GOGGLES ARE CRACKED. REPLACED THE SMOKE GOGGLES.SDR IPXA2015072191373Stiffener · corrodedINSPECTION TYPE:C, UPON REMOVAL OF LT OTBD WING UPPER T/E PANEL, INBD THE SUPPORTING STIFFENER, PN:113N1183-1, FOUND EXFOILATED BETWEEN STA 705.27-735.23. R & R LT OTBD WING UPPER LT OTBD WING UPPER T/E PANEL, INBD SUPPORTING STIFFENER, PN:113N1183-1 AT WS 70SDR IPXA2015072191372Stiffener · corrodedINSPECTION TYPE:C, UPON REMOVAL OF LT OTBD WING, UPPER T/E PANEL OTBD. THE SUPPORTING STIFFENER ASSY, PN:113N1184-1, FOUND EXFOLIATED BETWEEN WS 735.23-775.45. FABRICATED NEW STIFFENER, PN:113N1184-3 ON VT MAE TRAV T15/1149433 IAW DWG 113N1640.SDR IPXA2015071491142Access Panel · corrodedINSPECTION TYPE:C, ACCESS PANEL 542BB AREA BETWEEN MILL STEP AND SEAL CORRODED. CLEANED THE ACCESS PANEL AND FOUND IT TO BE OUT OF LIMITS IAW SRM 57-20-01-2R-5, DETAIL I, FIG 201 SHEET 2 AND NOTE B, REPLACEDTHE ACCESS PANEL.SDR IPXA2015071491132Access Panel · corrodedINSPECTION TYPE: C, ACCESS PANEL 543CB, BETWEEN SEAL AND MILL STOP AREA CORRODED. ACCESS PANEL REPLACED DUE TO SRM 57-20-01-2R-5, DETAIL I, FIG 201.SDR IPXA2015072291415Strap · corrodedINSPECTION TYPE:C, APU INLET MIDDLE STRAP CORRODED. REPAIR OF THE MIDDLE STRAP COMPLETED IAW SRM 53-80-15-2R, R1 DETAIL REV 93.00, THE REPAIR IS CLASSIFIED AS A MAJOR REPAIR.SDR IPXA2015071491170Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XCF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015071491157Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XAF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015071491156Floor Panel · brokenINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XKF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015071491155Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 241XGF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015071491145Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015071491143Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XJF HAS EDGE DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015072191371Skin · corrodedINSPECTION TYPE: C, NR 2 PYLON LT SIDE SKIN, EXTERNAL BELOW PANEL 443GL HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-02-0G, CHECKED LIMITS AND FOUND CORROSION TO BE OUT OF LIMITS IAW SRM 54-50-01-1A-1, DETAIL III. REPAIRED AREA IAW EA 757-5451-27-A2181 ANDSDR IPXA2015071491131Skin · damagedINSPECTION TYPE:C, FUSELAGE SKIN, BS207 BETWEEN S-14R AND S-15R LIGHTNING STRIKE. REPAIRED LIGHTNING STRIKE AT FUSELAGE SKIN BS207 BETWEEN S-14R AND S-15R IAW SRM 53-00-01-2R-6 SECTION I, PARAGRAPHS 1, 2, AND 3 INSTALLED REPAIR FASTENER.SDR IPXA2015063090702Floor Panel · damagedINSPECTION TYPE:C, MCD FLOOR PANEL 231XJF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015063090701Floor Panel · damagedINSPECTION TYPE: C, MCD FLOOR PANEL 231XFF DAMAGED. FABRICATED A NEW FLOOR PANE IAW SREO B757-5320-9692-H. 2.SDR IPXA2015070190734Engine · overtempRT ENGINE OVERTEMP ON DEPARTURE. THE EGT REACHED 655 DEGREES C. REDUCED THRUST LEVER TO NORMAL RANGE. DECLARED EMERGENCY. RETURNED. ACCOMPLISHED OVERTEMP VISUAL INSPECTION ON RT ENGINE MAX TEMP 654, DEGREES C. DURATION 9 SEC STEADY STATE. EPCS MSG EGT REDSDR IPXA2015070190711Wedge · puncturedINSPECTION TYPE:C-9L/W WING NR 2 L/E SLAT INBD T/E WEDGE DENTED, PUNCTURED ON LOWER SURFACE. REPAIRED WITH METAL HOT BOND IAW SRM 51-70-10 AND REO-G19023, REV A.SDR IPXA2015062590545Latch · crackedINSPECTION TYPE: C, BARREL NUT HOLE WAS FOUND TO BE CRACKED. NEW LATCH SUPPORT FITTING INSTALLED ON CARD 038704.SDR IPXA2015062490515Bulb · inoperativeEMERGENCY LIGHT HAS INOPERATIVE BULBS. REPLACED THE BULBS IAW AMM 33-51-01-2.SDR IPXA2015062690567Deflector · brokenINSPECTION TYPE:C-9, DURING LEAK CHECK OF THE NR 1 ENGINE THRUST REVERSER, FOUND DEFLECTOR RING ASSEMBLY TO BE BROKEN AT THE 1 O'CLOCK POSITION OF THE OTBD T/R. R & R DEFLECTOR RING IAW AMM 78-31-28-004-001-R00.
Back to Boeing 757-24APF