SDR IPXA3580304Wire · burnedINSPECTION ASE, UPON APPROACH WITH POWER STRONG ACRID RUBBER BURNING ODOR, LASTED APPROX 45 SEC TO 1 MIN, THEN DISSIPATED. FOUND RT TURNOFF LIGHT SWITCH WIRES BURNED, REMOVED PANEL LIGHT CTL LOCKOUT ALL C/B'S FOR PANEL LIGHT CTL. FOUND RT TURN OFF LIGHT SWITSDR IPXA3580297Battery · inoperativeEMERGENCY EXIT LIGHT OVER DOOR WAY WILL NOT TEST. REPLACED EXIT LIGHT BATTERY IAW 33-51-07-902-001 & 33-51-01-402-003. TEST NORMAL. IPC REF 33-57-11-01-045. PN ON/OFF 2013-1A, SN ON 369, SN OFF 50771.SDR IPXA3580358Floor Panel · delaminatedINSPECTION C1S2, MAIN DECK FLOOR PANEL 241XFF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580357Floor Panel · tornINSPECTION C1S2, MAIN DECK FLOOR PANEL 232XXF TORN AT INSERT HOLE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580356Floor Panel · damagedINSPECTION S1C2, MAIN DECK FLOOR PANEL 231XVF HAS LOWER INSERT SPINNING IN PANEL. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-H.SDR IPXA3580355Floor Panel · delaminatedINSPECTION C1S2, MAIN DECK FLOOR PANEL 242XEF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580354Floor Panel · tornINSPECTION C1S2, MAIN DECK FLOOR PANEL 231XWF TORN ON BOTTOM SIDE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580353Floor Panel · damagedINSPECTION C1S2, MAIN DECK FLOOR PANEL 241XDF IS PUNCTURED AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580249Floorboard · damagedINSPECTION TYPE:C10, MAIN CABIN FLOORBOARD 241XDF IS DAMAGED. FABRICATE NEW FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA3580369Door Frame · bentINSPECTION C10, MAIN DECK CARGO COMPARTMENT DOOR INTERNAL FRAME BENT. PERFORMED REPAIR IAW EO B757-5230-52228-A.SDR IPXA3580329Floor Panel · damagedINSPECTION C10, MAIN CABIN FLOOR PANEL 242XCF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580228Floor Panel · damagedC-10 INSPECTION, MAIN CABIN FLOOR PANEL 241XJF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580227Floor Panel · damagedC-10 INSPECTION, MAIN CABIN FLOOR PANEL 242XJF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580226Floor Panel · damagedC-10 INSPECTION, MAIN CABIN FLOOR PANEL 241XFF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580225Floor Panel · damagedC-10 INSPECTION, MAIN CABIN FLOOR PANEL 241XDF DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580155Battery Pack · inoperativeDURING PS-1, EMERGENCY LIGHT OVER L1 DOOR IS INOPERATIVE. R & R BATTERY PACK IAW AMM 33-51-07-9. EMERGENCY LIGHTS OPERATE NORMALLY.SDR IPXA3580345Skin · gougedINSPECTION TYPE:C10, LT WING OTBD FORE FLAP L/E GOUGED AT OTBD END. REPAIRED IAW SRM 57-53-01-2R-3.SDR IPXA3580134Eec · malfunctionedRT ENGINE INFLIGHT SHUTDOWN, DUE TO HIGH OIL TEMP. COMPLIED WITH HIGH OIL TEMP PER MM 72-00-00-206-547-P00. COMPLETED INSPECTION PER MM 72-00-00-206-547-P00. EEC REPLACED. RAN ENGINE AT MULTIPLE THROTTLE SETTINGS FOR 30 MINUTES. ALL ENGINE PARAMTERS NORMALSDR IPXA3580090Torque Tube · failedON DEPARTURE RECEIVED A T/E FLAP ASSY FLAPS STUCK AT 15 DEGRESS. R & R RT WING NR 8 FLAP TRANSMISSION AND RT WING T/E DRIVE TORQUE TUBE.SDR IPXA3580322Frame · damagedINSPECTION C-8, SCREW STRIKE ON MAIN CABIN FRAME BS 1200. ACCOMPLISHED NEO B757-5310-52182-A.SDR IPXA3580321Frame · damagedINSPECTION C-8, SCREW STRIKE ON MAIN CABIN FRAME BS 1240. ACCOMPLISHED EO B757-5310-52176-A.SDR IPXA3580177Floorboard · damagedDURING C-8, MAIN CABIN FLOORBOARD BS 781-820, RBL 45 - 65 HAS BAD INSERTS. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580100Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 231XMF HAS EDGE DAMAGE AND IS PUNCTURED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580099Floor Panel · delaminatedC-8 INSPECTION, MAIN CABIN FLOOR PANEL 231XEF HAS DELAMINATED CORNER. FABRICATED NEW FLOOR PANEL IAW UPS SREO B757-5320-9692-H.SDR IPXA3580098Floorboard · delaminatedC-8 INSPECTION, MAIN CABIN FLOORBOARD 231XDF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580097Floor Panel · damagedC-8 INSPECTION, MAIN CABIN FLOOR PANEL 232XTF HAS SEVERAL PUNCTURES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580095Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 232XSF HAS BAD INSERT. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580094Floorboard · damagedC-8 INSPECTION, MAIN CABIN FLOORBOARD 231XAF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580141Floorboard · delaminatedDURING C-8 INSPECTION, MAIN CABIN FLOORBOARD 232XJF HAS DELAMINATED CORNER. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580121Floorboard · damagedDURING C-8 INSPECTION, MAIN CABIN FLOORBOARD 231XRF HAS SEVERAL PUNCTURES. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580312Floorbeam · corrodedINSPECTION C-8, MAIN CABIN FLOORBEAM, BS 1200, LBL 25-45. REMOVED CORROSION ORIG MATERIAL .220, MATERIAL REMOVED .003, MATERIAL REMAINING .217. AREA HAS PREVIOUS REPAIR AT THIS AREA.SDR IPXA3580311Floorbeam · corrodedINSPECTION C-8, MAIN CABIN FLOORBEAM BS 1200, LBL 45-57. REMOVED CORROSION ORIG MAT .220, MAT REMOVED .056, MAT REMAINING .164. PREVIOUS REPAIR AT THIS AREA.SDR IPXA3580308Floorbeam · corrodedINSPECTION C8, MAIN CABIN FLOORBEAM BS 1200, BL 0 - LBL 25. REMOVED CORROSION, ORIG MATERIAL .220, MATERIAL REMOVED .041, MATERIAL REMAINING .179. PREVIOUS REPAIR INSTALLED IN THIS AREA.SDR IPXA3580307Floorbeam · corrodedINSPECTION C-8, MAIN CABIN FLOORBEAM BS 1200 BL 0 - RBL25 CORRODED. REMOVED CORROSION, ORIG MATERIAL .220, MATERIAL REMOVED .021, MATERIAL REMAINING .199 AR, EA HAS PREVIOUS REPAIR FWD FLANGE OF AREA AFT FLANGE FOUND TO BE OUT OF LIMITS. INSTALLED REPAIR ANGSDR IPXA3580291Floorbeam · corrodedINSPECTION C-8, MAIN CABIN FLOORBEAM BS 1100, LBL 25-45 CORRODED. ACCOMPLISHED REPAIR EO B757-5310-52106-A.SDR IPXA3580182Floorboard · brokenINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XLF BROKEN AND MISSING INSERT FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3580180Floor Panel · delaminatedDURING C-8, MAIN CABIN FLOOR PANEL 251XFF DELAMINATED AND MISSING INSERT FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580179Floor Panel · delaminatedDURING C-8, MAIN CABIN FLOOR PANEL 242XEF DELAMINATED IN THE CORNER FABRICATED NEW FLOOR PANEL IAW SREO B757-5370-9692-H.SDR IPXA3580176Floor Panel · damagedDURING C-8, MAIN CABIN FLOOR PANEL 232XTF FOUND DAMAGED ON BOTTOM. FABRICATED NEW FLOOR PANEL IAW SREO B757-5370-9692-H.SDR IPXA3580173Floor Panel · delaminatedDURING C-8, MAIN CABIN FLOOR PANEL 242XFF DELAMINATED AND HAS EDGE DAMAGE FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-H.SDR IPXA3580142Floor Panel · damagedDURING C-8 INSPECTION, MAIN CABIN FLOOR PANEL 252XTF HAS EXCESSIVE EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580122Floor Panel · damagedDURING C-8 INSPECTION, MAIN CABIN FLOOR PANEL 231XSF DAMAGED ON BOTTOM. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580107Floor Panel · damagedDURING S3C1 INSPECTION, FLOOR PANEL 232ZAF HAS TWO DENTS OF APPROXIMATELY 2" W X 5" L. THERE ARE CRACKS IN AND AROUND THE DENTED AREA OF THE SKIN. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580106Floor Panel · puncturedDURING S3C1 INSPECTION, FLOOR PANEL 251XEF TOP SURFACE PUNCTURED, FARICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580104Floor Panel · damagedDURING S3C1 INSPECTION, FLOOR PANEL 232XFF HAD SEVERAL AREAS OF EDGE DAMAGE ALONG THE FASTENER ROW, THE LOWER SURFACE OF THE PANEL, SEVERAL ARE CRACKED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580059Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 252XAF UPPER SURFACE IS DENTED AND PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2013082835805Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 242XCF HAS BROKEN SCREW INSERTS. REPLACED INSERTS IN FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2013082835803Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 241XCF HAS BROKEN SCREW INSERTS. REPLACED INSERTS IN MAIN CABIN FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2013082835802Floor Panel · damagedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 242XJF HAS BROKEN SCREW INSERTS. REPLACED INSERTS IN MAIN DECK FLOOR PANEL IAW EO B757-5320-9692- H.SDR IPXA3580105Floor Panel · debondedDURING S3C1 INSPECTION, MAIN DECK FLOOR PANEL, 251XRF, BS 1680-1720 IS DISBONDED FROM HONEYCOMB. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.
Back to Boeing 757-24APF