Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3580062Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 252XCF, BS 1200-1320 RT IS DELAMINATED AROUND UPPER SURFACE EDGES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580061Floor Panel · puncturedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 252XQF, BS 1540-1600 RT IS PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580056Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 232XVF BS 820-880 RT IS DELAMINATED AROUND UPPER EDGES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580055Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 232XSF BS 780-820 RT IS DELAMINATED ON UPPER SURFACE EDGES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580186Skin · chafedS3C1 INSPECTION, LT INBD T/E FLAP L/E IS CHAFED. CLEANED AND PREPPED, NOTED AREA OF DAMAGE ON LEFT INBD T/E FLAP L/E. REMOVED DELAMINATED FIBERGLASS PLIES TO EXPOSE PREVIOUS T/E FLAP NOSE SKIN REPAIR SRM 51-10-02-0G. NEED NDT INSPECTION HFEC IAW NTM 51-00-1 SDR IPXA3580170Floorbeam · corrodedDURING S3C1, BS 1520 FLOORBEAM LOWER FLANGE CORRODED AT RBL 47. REMOVED CORROSION ON FLOORBEAM AT BS 1520, IAW SRM 53-00-51-1A-1. FOUND TO BE OUT OF LIMITS IAW SRM 53-00 -51-1A-1, FIG 101.SDR IPXA3580063Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 231XTF IS DELAMINATED AT EDGES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580060Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 232XWF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580058Floor Panel · tornS3C1 INSPECTION, MAIN DECK FLOOR PANEL 232XRF HAS A TORN INSERT HOLE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580057Floor Panel · crackedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 252XLF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580054Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 231XUF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3580053Floor Panel · delaminatedS3C1 INSPECTION, MAIN DECK FLOOR PANEL 232XXF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2013082835804Floor Panel · damagedINSPECTION TYPE:S3C1, MAIN DECK FLOOR PANEL 252XFF IS MISSING FOUR SCREW INSERTS. REPLACE FOUR INSERTS IN MAIN DECK FLOOR PANEL IAW EO B757-5320-9 692-H.SDR IPXA3579905Floor Panel · crackedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XHF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579904Floor Panel · crackedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 231XHF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579903Floor Panel · crackedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 241XDF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579902Floor Panel · crackedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XJF IS CRACKED. FABRICATE A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579889Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 221XAF IS DELAMINATED ON THE FWD END FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-HSDR IPXA3579888Skin · dentedINSPECTION TYPE:C-8, NR 8 SLAT UPPER SURFACE DENTED AT OSS 451.6. REPAIRED NR 8 SLAT WEDGE IAW PF SRM 57-43-02 AND 51-70-10, REPAIR 4, FIG 201, SHT 1.SDR IPXA3579766Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XHC IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579877Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XQF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579876Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 232XCF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579875Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XAF IS DAMAGED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579874Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 221XCF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13579787Floorboard · damagedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 211XAF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO, B757-5320-9692-HSDR IPXA3579761Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XMF IS DAMAGED. FABRICATE NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579760Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XTF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579759Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XNF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579758Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XPF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579757Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XQF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579755Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XLF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579754Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XJF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579752Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251XBF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579751Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251-XFF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579750Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251XEF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579749Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 252XFF DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579707Control Unit · inoperativeACFT WOULD NOT PRESSURIZE. ALSO ACFT HAD LT FWD DOOR EICAS MESSAGE. LT FWD DOOR REMAINED WITH OVERHEAD ENTRY DOOR LT ON DESCENT 4300 WENT OUT, BACK ON AT 4200, STAYED ON UNTIL BLOCK IN. REPLACED NR 1 AUTO CABIN CONTROL UNIT IAW MM 21-31-02 IPC REF 12-31-02-SDR IPXA3580065Floorbeam · corrodedC-8 INSPECTION, MAIN CABIN FLOORBEAM TEE CORRODED AT BS 1100, LBL24-36. REPAIRED CORRODED TEE IAW EO B757-5310-51942-A AND REO-G16556, REV A.SDR IPXA3580064Floorbeam · corrodedC-8 INSPECTION, MAIN CABIN UNDER FLOORBEAM TEE IS CORRODED AT BS 1100, LBL 0 TO LBL 24. REPAIRED CORRODED TEE IAW EO B757-5310-51920-A AND REO-G16556, REV A.SDR IPXA3580048Frame · damagedC8 INSPECTION, BS 660 AT STRINGER 16L HAS A SCREW STRIKE. INSTALLED FRAME REPAIR IAW REO G16501, REV B.SDR IPXA2013083080016Frame · damagedC8 INSPECTION, BS 440 AT STRINGER 16R HAS SCREW STRIKE. DRILLED HOLE AT DAMAGE LOCATION AND INSTALLED RIVETS IAW EO B757-5310-51920-A & REO -G16538, REV IR.SDR IPXA3579970Attach Fitting · corrodedINSPECTION C8, MAIN CABIN ATTACH FRAME AT STA 1060, LBL 20 HAS CORROSION. REPLACE TEE, PN 144N5005-5.SDR IPXA3579957Support · corrodedINSPECTION C8, MAIN CABIN UNDER FLOORBOARD, ATTACH FRAME ON SEAT TRACK CORRODED AT STA 1050 TO STA 1100. REPLACED TRACK SUPPORT, PN 144N8031.SDR IPXA3579900Frame · corrodedINSPECTION TYPE:C8, MAIN CABIN FLOOR, ONE ATTACH FRAME CORRODED NR 1060, LBL 24-26. REPLACE TEE.SDR IPXA3579896Frame · corrodedINSPECTION TYPE:C8, MAIN CABIN CENTER SECTION UPPER ATTACH FRAME AT BS 1070, RBL 12 IS CORRODED. REPLACE TEE.SDR IPXA13579784Floor Panel · corrodedINSPECTION TYPE:C8, MAIN CABIN, UNDER FLOOR PANEL, AFT DECK PLATE HAS CORROSION BS 1680, RBL5. REPAIRED AFT DECK PLATE IAW SRM 53-60-51-2R-8.SDR IPXA13579783Deck Plate · corrodedINSPECTION TYPE: C8, MAIN CABIN PRESSURE DECK PLATE IS CORRODED AT NUTPLATE HOLES AT BS 1681, RBL 31-39. REMOVED CORROSION AND CHECKED LIMITS IAW SRM 53-60-51-1A-1, FOUND TO BE WITHIN LIMITS APPLIED PROTECTIVE TREATMENT IAW SRM 51-20-01.SDR IPXA3579734Floor Panel · damagedINSPECTION TYPE:C10, MAIN CABIN FLOOR PANEL 241XGF IS DAMAGED ON EDGES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580073Angle · corrodedINSPECTION TYPE:C8, MAIN CABIN BS 1610-1630, RBL 60 CREASE BEAM RETAINER ANGLE CORRODED IN TWO PLACES. R & R RETAINER ANGLE IAW PRODUCTION DWG 146N5353-70-2.SDR IPXA13579684Floor Panel · damagedINSPECTION TYPE: C1S3, MAIN DECK FLOOR PANEL 221XCF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.
Back to Boeing 757-24APF