Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA13577332Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XKF IS DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577331Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 252XLF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577330Floorboard · damagedINSPECTION TYPE: S4C8, FLOORBOARD 252XNF IS DAMAGED. REPAIRED FLOORBOARD IAW SRM 53-00-50-1A-1, TABLE 1.SDR IPXA13577329Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 251XLF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577328Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 251XPF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577327Floorboard · damagedINSPECTION TYPE:S4C8, FLOORBOARD 251XNF IS DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577326Floorboard · damagedINSPECTION TYPE:S4C8, UPPER CARGO FLOORBOARD 241XJF HAS TORN OUT INSERTS. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577325Floorboard · tornINSPECTION TYPE:S4C8, UPPER CARGO FLOORBOARD 242XMF HAS TORN OUT INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577324Floorboard · damagedINSPECTION TYPE:S4C8, UPPER CARGO FLOORBOARD 252XBF HAS TORN OUT INSERTS. FABRICATED UPPER CARGO FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577323Floorboard · tornINSPECTION TYPE:S4C8, UPPER CARGO FLOORBOARD 251XBF HAS TORN OUT INSERTS. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577322Floorboard · tornINSPECTION TYPE:S4C8, UPPER CARGO FLOORBOARD 251XCF HAS TORN OUT INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13577321Floorboard · tornINSPECTION TYPE:S4C8, UPPER CARGO FLOORBOARD 251XFF HAS TORN OUR INSERTS. FABRICATED UPPER CARGO FLOORBOARD IAW SREO B757-532-9692-H.SDR IPXA13577320Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 231XKF HAS INSERTS AND EDGES BROKEN. FABRICATED CABIN FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577319Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 232XEF INSERTS AND EDGES DAMAGED. FABRICATED CABIN FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577318Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 232XFF HAS INSERTS AND EDGES DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-53200-9692-H.SDR IPXA13577317Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 232XMF HAS INSERTS AND EDGES BROKEN. FABRICATED CABIN FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577316Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN FLOOR PANEL 231XGF HAS INSERTS AND EDGES BROKEN. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3577447Floor Panel · damagedINSPECTION TYPE:S4C8, MCD FLOOR PANEL 231XJF CRACKED. FABRICATED NEW FLOOR PANEL.SDR IPXA3577416Floor Panel · damagedINSPECTION TYPE:S4C8, MCD FLOOR PANEL 231XFF HAS MISSING INSERT AND EDGE DAMAGE DOT 11-58. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3577415Floor Panel · damagedINSPECTION TYPE:S4C8, MCD FLOOR PANEL 232XCF HAS BROKEN OUT INSERT AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692- H.SDR IPXA13577388Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN LT OTBD FLOOR PANEL 231XLF HAS TWO INSERTS BROKEN. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577315Floor Panel · brokenINSPECTION TYPE:S4C8, CABIN RT INBD FLOOR PANEL 232XTF HAS 3 INSERTS BROKEN. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13577314Floor Panel · crushedINSPECTION TYPE:S4C8, MCD FLOOR PANEL 232XBF MISSING INSERTS AND HAS SEVERAL CRUSHED AREAS. FABRICATED MCD FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577313Floor Panel · puncturedINSPECTION TYPE:S4C8, MCD FLOOR PANEL 222XBF PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13577301Floor Panel · damagedINSPECTION TYPE:S4C8, CABIN LT OTBD FLOOR PANEL 231XQF HAS THREE INSERTS AND EDGES BROKEN OFF. DOT 3537. FABRICATED NEW FLOOR PANEL IAW EO R757-5320-9692-H.SDR IPXA13577179Skin · damagedINSPECTION TYPE:C-16, LT WING OTBD MAIN FLAP UPPER SURFACE NUMEROUS HOLES. REPAIRED IAW SRM 57-53-01-2R-1 & 51-70-06.SDR IPXA13577143Wedge · delaminatedINSPECTION TYPE:C-16, RT NR 6 SLAT UPPER INBD T/E HAS AREA OF DELAMINATION. REPAIRED SLAT WITH METAL BOND REPAIR IAW SRM 57-43-02 & 51-70-10.SDR IPXA13577142Skin · damagedINSPECTION TYPE:C-16 RUDDER RT SIDE HAS A HOLE. REPAIRED IAW SRM 51-70-04 & 55-40-01SDR IPXA13577137Wedge · gougedINSPECTION TYPE:C-16, RT WING OTBD AFT FLAP, LOWER SURFACE GOUGED JUST OTBD OF OTBD FAIRING. REPAIRED AFT FLAP IAW SRM 51-70-04.SDR IPXA13577048Wedge · chafedINSPECTION TYPE:C16, RT WING NR 8 SLAT T/E WEDGE CHAFED. REPAIRED THE SLAT IAW SRM 51-70-10, REPAIR NR 4, FIG NR 202, SHEET NR 8.SDR IPXA13577116Floorboard · damagedINSPECTION TYPE:S3C8, FLOORBOARD 232XPF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA13577007Transmission · inoperativeEMERGENCY DECLARED, FLAPS FAILED TO MOVE, T/E LIGHT ON AND EICAS MESSAGES T/E FLAP DISAGREE DISPLAYED FLAPS ALSO INOPERATIVE ON T/E ALTERNATE SYS. ACCOMPLISHED FIM 27-51-00-815-805 AND FIM 27-51-00-815-808 FOUND NR 4 FL FLAP TRANSMISSION OVERLOAD INDICATOR TSDR IPXA13577020Charger · inoperativeEXTERIOR EMERGENCY LIGHT IS INOPERATIVE. REPLACED EMERGENCY BATTERY CHARGER IAW AMM 33-51-11-01, ITEM 21.SDR IPXA3578107Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 251XMF HAS DELAMINATED EDGES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577000Lamp · inoperativeEMERGENCY LIGHT ASSY HAS FOUR LAMPS INOPERATIVE. INSTALLED LAMPS IAW AMM 33-51-01.SDR IPXA3576981Receptacle · dirtyEXTERIOR EMERGENCY LIGHT INOPERATIVE. CLEANED LIGHT ASSY RECEPTACLE, INSTALLED BULB. OPS CHECKED GOOD IAW MM 33-50-00.SDR IPXA3576943Wedge · dentedNR 2 SLAT T/E WEDGE DENT REPAIR, REF D496328. REPAIRED IAW EO B757-5750-49562-C.SDR IPXA13577176Floor Panel · crackedINSPECTION TYPE: S3C8, MAIN DECK FLOOR PANEL 241CXF CRACKED. FABRICATED MAIN DECK FLOOR PANEL IAW SERO B757-5320-9692-H.SDR IPXA13577162Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 251XKF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577161Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 251XRF HAS EDGE DAMAGE. FABRICATED MAIN DECK FLOOR PANEL IAW SREO NR B757-5320-9692-H.SDR IPXA13577160Floorboard · damagedINSPECTION TYPE:S3C8 CABIN FLOORBOARD 231XPF EDGES ARE DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577159Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 252XBF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577158Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 252XAF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577157Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 252XTF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577156Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 231XKF EDGES ARE DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577155Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 231XNF EDGES ARE DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577154Floorboard · damagedINSPECTION TYPE:S3C8, CABIN FLOORBOARD 231XMF EDGES ARE DAMAGED (PANEL RACK) DOT NR 17-98. FABRICATED CABIN FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577153Floor Panel · dentedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 241XBF UPPER SURFACE DENTED NR 53-122. FABRICATED FLOOR PANEL IAW SREO NR B757-5320-9692-H.SDR IPXA13577152Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 241XEF HAS EDGE DAMAGE NR 53-120. FABRICATED FLOOR PANEL 241XEF IAW SREO NR B757-5320-9692-H.SDR IPXA13577151Floor Panel · damagedINSPECTION TYPE:S3C8, MAIN DECK FLOOR PANEL 252XUF HAS EDGE DAMAGE. FABRICATED MAIN DECK FLOOR PANEL IAW SREO B757-5320-9692-H.
Back to Boeing 757-24APF