What was found
INSPECTION TYPE:C-16, RT NR 6 SLAT UPPER INBD T/E HAS AREA OF DELAMINATION. REPAIRED SLAT WITH METAL BOND REPAIR IAW SRM 57-43-02 & 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C-16, RT NR 6 SLAT UPPER INBD T/E HAS AREA OF DELAMINATION. REPAIRED SLAT WITH METAL BOND REPAIR IAW SRM 57-43-02 & 51-70-10.