Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2571645Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 232XWF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 232XWF IAW EO B757-5320-9692-H.SDR IPXA2571644Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 241XLF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 241XLF IAW EO B757-5320-9692-H.SDR IPXA2571643Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 241XGF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 241XGF IAW EO B757-5320-9692-H.SDR IPXA2571642Floor Panel · damagedINSPECTION TYPE:C-CK MAIN CARGO FLOOR PANEL 241XHF IS DELAMINATED AND DAMAGED. FABRICATED MAIN CARGO FLOOR PANEL 241XHF IAW EO B757-5320-9692-H.SDR IPXA2571641Floor Panel · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 242XKF IS DELAMINATED AND MISSING INSERTS. FABRICATED MAIN CARGO FLOOR PANEL 242XKF IAW EO B757-5320-9692-H.SDR IPXA2571640Floor Panel · dentedINSPECTION TYPE:C-CK MAIN CARGO FLOOR PANEL 242XLF IS DENTED AND MISSING INSERTS. FABRICATED MAIN CARGO FLOOR PANEL 242XLF IAW EO B757-5320-9692-HSDR IPXA2571636Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XCF IS DENTED MISSING INSERTS. FABRICATED MAIN CARGO FLOOR PANEL 251XCF IAW EO B757-5320-9692-H.SDR IPXA2571635Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XBF IS DENTED, DELAMINATED. FABRICATED MAIN CARGO FLOOR PANEL 251XBF IAW EO B757-5320-9692-H.SDR IPXA2571634Floor Panel · dentedINSPECTION TYPE:C-CK MAIN CARGO FLOOR PANEL 251XEF IS DENTED HOLES. FABRICATED MAIN CARGO FLOOR PANEL 251XEF IAW EO B757-5320-9692-H.SDR IPXA2571633Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XDF IS DENTED. FABRICATED MAIN CARGO FLOOR PANEL 251XDF IAW EO B757-5320-9692-H.SDR IPXA2571632Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 241XJF HAS DENT DAMAGE AND MISSING INSERTS. FABRICATED MAIN CARGO FLOOR PANEL 241XJF IAW EO B757-5320-9692-H.SDR IPXA2571631Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252 XPF HAS DENT DAMAGE, DELAMINATED. FABRICATED MAIN CARGO FLOOR PANEL 252XPF IAW EO B757-5320-9692-H.SDR IPXA2571630Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XNF HAS DENT DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 252XNF IAW EO B757-5320-9692-H.SDR IPXA2571629Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XQF HAS DENT DAMAGE, DELAMINATED. FABRICATED MAIN CARGO FLOOR PANEL 252XQF IAW EO B757-5320-9692-H.SDR IPXA2571628Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XJF HAS DENT DAMAGE, DELAMINATED. FABRICATED MAIN CARGO FLOOR PANEL 252XJF IAW EO B757-5320-9692-H.SDR IPXA2571627Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XDF HAS DENT DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 252XDF IAW EO B757-5320-9692-H.SDR IPXA2571626Floor Panel · brokenINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XEF IS BROKEN. FABRICATED MAIN CARGO FLOOR PANEL 252XEF IAW EO B757-5320-9692-H.SDR IPXA2571625Floor Panel · brokenINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XFF IS BROKEN. FABRICATED MAIN CARGO FLOOR PANEL 252XFF IAW EO B757-5320-9692-H.SDR IPXA2571621Floor Panel · dentedINSPECTION TYPE:C-CK MAIN CARGO FLOOR PANEL 252XAF HAS DENT. FABRICATED MAIN CARGO FLOOR PANEL 252XAF IAW EO B757-5320-9692-H.SDR IPXA2571619Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XCF HAS DENTED AND MISSING INSERTS. FABRICATED MAIN CARGO FLOOR PANEL 252XCF IAW EO B757-5320-9692-H.SDR IPXA2571618Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XGF IS DENTED. FABRICATED MAIN CARGO FLOOR PANEL 251XGF IAW EO B757-5320-9692-H.SDR IPXA2571617Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XLF HAS DENTED AND EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 251XLF IAW EO B757-5320-9692-H.SDR IPXA2571616Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XKF HAS DENT. FABRICATED MAIN CARGO FLOOR PANEL 251XKF IAW EO B757-5320-9692-H.SDR IPXA2571615Floor Panel · crackedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XMF IS CRACKED. FABRICATED MAIN CARGO FLOOR PANEL XMF IAW EO B757-5320-9692-H.SDR IPXA2571614Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XHF IS DENTED AND EDGE DAMAGED. FABRICATED MAIN CARGO FLOOR PANEL 251XHF IAW EO B757-5320-9692-H.SDR IPXA2571613Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XJF IS DENTED AND MISSING INSERTS. FABRICATED MAIN CARGO FLOOR PANEL 251XJF IAW EO B757-5320-9692-H.SDR IPXA2571589Window · delaminatedWHILE PERFORMING PDC FOUND F/O'S SLIDING WINDOW HAZY AND SEPARATION AT LOWER AFT CORNER. R & R FO'S SLIDING WINDOW IAW AMM 56-11-02-04.SDR IPXA12571582Floorboard · delaminatedINSPECTION TYPE:C-CK, FLT DECK 212XAF FLOORBOARD DELAMINATED AFT OTBD CORNER AND INSERT MISSING. FABRICATED FLT DECK 212XAF FLOORBOARD DELAMINATED IAW EO B757-5320-96 92-H.SDR IPXA12571578Seat Track · corrodedINSPECTION TYPE:C-CK, STA 1180+5, RBL 60, SEAT TRACK HAS CORROSION ON INNER FLANGE. REPAIRED IAW EA 120120 AND EO B757-5310-45881-A.SDR IPXA12571577Seat Track · corrodedINSPECTION TYPE:C-CK, STA 1200, RBL 60, SEAT TRACK HAS CORROSION ON INNER FLANGE. REPAIRED IAW EA NR 120119.SDR IPXA12571576Sill · corrodedINSPECTION TYPE:C-CK, MAIN CARGO DOOR SILL WEB STA 560, LBL 60, WL 208 HAS CORROSION AT SCREW HOLE. REPAIRED IAW EA 120113 AND EO B757-5310-45870-A.SDR IPXA2572188Crease Beam · corrodedINSPECTION TYPE: C, MAIN CARGO BAY BS 1577 RT CREASE BEAM CORRODED. REPAIRED CREASE BEAM IAW EA 120255 IR, AND EO.SDR IPXA2572184Cargo Track · corrodedINSPECTION TYPE: C, MAIN CARGO TRACK BS 1080 TO 1200, RBL 45, CARGO TRACK CORRODED ON UPPER SURFACE AT NUTPLATE HOLES. REMOVED CORROSION ORIGINAL THICKNESS .080 LOSS OF .032 WITH .047 IS OUT OF LIMITS. R & R CARGO TRACK IAW SRM 51-40-02 AND DWGS 146N5218 ANDSDR IPXA2572183Floor Panel · corrodedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT STA 1660 TO 1680, LBL 26, 7EA FLOOR PANEL FASTENER HOLES HAVE CORROSION. REMOVED CORROSION ORIGINAL THICKNESS .080 LOSS OF .036 WITH .044 IS OUT OF LIMITS. R & R SEAT TRACK IAW SRM 51-40-02 AND DWGS 146N5220 AND 146SDR IPXA12572152Floorbeam · corrodedINSPECTION TYPE: C, MAIN CARGO FLOORBEAM STA 1200, LBL 45 TO RBL 55 FLOORBEAM CORRODED ON UPPER FLANGE AT NUTPLATE HOLES. REMOVED CORROSION. ORIGINAL THICKNESS .270, MATERIAL REMOVED IS .025-.05, REMAINING THICKNESS .180-.205, OUT OF LIMITS IAW SRM 53- 00-5SDR IPXA12572149Floor Panel · corrodedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT STA 1680, RBL 3 TO RBL 23, FLOOR DECKING HAS CORROSION. REMOVED CORROSION AT STA 1680, RBL 3 TO RBL 23, ORIGINAL THICKNESS IS .075, LOSS OF .003- .017 WITH .072- .058 REMAINING IS OUT OF LIMITS. REMOVED DAMAGE AND SDR IPXA12572148Cargo Track · corrodedINSPECTION TYPE: C, MAIN CARGO TRACK STA 1060 TO 1100, LBL 60, 3 EA NUTPLATES CORRODED. REMOVED CORROSION. ORIGINAL MATERIAL THICKNESS .075 MAX LOSS OF .020 WITH .055 REMAINING IS OUT OF LIMITS IAW 53-00-52-1A1. ACCOMPLISHED STEPS OF EA 120230 IR EO B757-53SDR IPXA12572144Floorbeam · corrodedINSPECTION TYPE: C, MAIN CARGO BAY BS 1680, LBL 3 TO LBL 14, FLOORBEAM HAS CORROSION. REMOVED CORROSION, ORIGINAL THICKNESS IS .075 LOSS OF .005-.025 WITH .070- .050 REMAINING IS OUT OF LIMITS. REMOVED DAMAGE AND REPAIRED IAW EA 128249 EO B757-5310-46277-A.SDR IPXA12572143Floorbeam · corrodedINSPECTION TYPE: C, MAIN CARGO BAY BS 1680, RBL 27 TO RBL 41, FLOORBEAM HAS CORROSION. REMOVED CORROSION ORIGINAL THICKNESS IS .075, LOSS OF .003- .030 WITH .072- .045. REMAINING IS OUT OF LIMITS, REMOVED DAMAGE AND REPAIRED IAW EA 128249. EO B757-5310-46277SDR IPXA12572096Floorbeam · corrodedINSPECTION TYPE: C, MAIN CARGO FLOORBEAM, BS 1100, BL 0 TO RBL 45, CORRODED ON UPPER SURFACE AT NUTPLATE HOLES. REMOVED CORROSION ON FLOORBEAM, ORIGINAL MATERIAL .0196 LOSS OF .101 WITH .095. FOUND OUT OF LIMITS IAW SRM 53-00-51-1A1. REMOVED DAMAGE AND REPAISDR IPXA2572031Floor Support · corrodedINSPECTION TYPE:C, MAIN CARGO COMPARTMENT RT SIDE BS 1055, RBL 41 AT FLOOR SUPPORT HAS (2) AREAS OF CORROSION AT SCREW HOLES. REMOVED CORROSION, ORIGINAL MATERIAL THICKNESS .050 100 PERCENT MATERIAL LOSS AT FASTENER HOLE FABRICATED AND REPLACED FLOOR SUPPORTSDR IPXA12571753Frame · crackedINSPECTION TYPE:C-CK, MAIN CARGO BS 520 FRAME IS BENT AND CRACKED JUST BELOW STRINER 16R. INSTALLED FRAME REPAIR IAW EA 120160 IR AND EO B757-5310-45965-A.SDR IPXA2571639Floor Panel · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XNF IS DELAMINATED. FABRICATED MAIN CARGO FLOOR PANEL 251XNF IAW EO B757-5320-9692-H.SDR IPXA2571638Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XQF HAS COMPOSITE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 251XQF IAW EO B757-5320-9692-H.SDR IPXA2571637Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XPF HAS COMPOSITE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 251XPF IAW EO B757-5320-9692-H.SDR IPXA2571624Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XTF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 252XTF IAW EO B757-5320-9692-H.SDR IPXA2571623Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XSF HAS EDGE DAMAGE. FABRICATED MAIN CARGO FLOOR PANEL 252XSF IAW EO B757-5320-9692-H.SDR IPXA2571622Floor Panel · damagedINSPECTION TYPE:C-CK MAIN CARGO FLOOR PANEL 252XRF HAS EDGE DAMAGE FABRICATED MAIN CARGO FLOOR PANEL 252XRF IAW EO B757-5320-9692-HSDR IPXA12571558Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 232XMF HAS INSERT DAMAGE. FABRICATED MAIN CARGO COMPARTMENT FLOOR PANEL IAW EO B757-5320- 9692-H.SDR IPXA12571555Floor Panel · damagedINSPECTION TYPE:C-CK, FLOOR PANEL 212XAF HAS PUNCTURES AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL 212XAF IAW EO B757-5320-9692-H.
Back to Boeing 757-24APF