What was found
INSPECTION TYPE: C, MAIN CARGO FLOORBEAM, BS 1100, BL 0 TO RBL 45, CORRODED ON UPPER SURFACE AT NUTPLATE HOLES. REMOVED CORROSION ON FLOORBEAM, ORIGINAL MATERIAL .0196 LOSS OF .101 WITH .095. FOUND OUT OF LIMITS IAW SRM 53-00-51-1A1. REMOVED DAMAGE AND REPAIRED FLOORBEAM IAW EA 120225 IR B757-5310-46239-A.