Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA1565349Floor Panel · delaminatedINSPECTION TYPE:C3, FLOOR PANEL HAS DAMAGE AND DELAMINATION BS 1100-1200 LBL 25-45 WL 208 (MARKED). FABRICATED NEW FLOOR PANEL IAW EO NR B757-5320-9692-G.SDR IPXA1565342Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW B757-5320-9692G.SDR IPXA1565341Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD HAS EDGE DAMAGE AND DAMAGED INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692G.SDR IPXA1565340Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY SEAT TRACK AFT END IS CORRODED BS 1681, RBL 45, WL 208. CLEANED AND TREATED IAW SRM 53-60-52-01I, 53-00-52-1A1, AND 51-10-02-0G.SDR IPXA1565338Floor Panel · delaminatedINSPECTION TYPE:C3, FLOOR PANEL HAS DAMAGED INSERTS AND FOUND TO BE DELAMINATED. REPLACED FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA1565337Floor Panel · delaminatedINSPECTION TYPE:C3, FLOOR PANEL HAS DAMAGED INSERTS AND FOUND TO BE DELAMINATED. REPLACED FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA1565336Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA1565335Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 335-BS 440, RBL 25-RBL 45, WL 208 HAS SEVERAL AREAS OF EDGE DAMAGE. REPLACED FLOOR PANEL BS 335-440, RBL 25-45 IAW SRM 53-00-50-1A1 AND IAW EO B757-5320-9692-G.SDR IPXA1565334Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE AND DELAMINATION BS 1100-1200, LBL 45-60, WL 208 (MARKED). REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1 AND EO B757-5320-9692-G.SDR IPXA1565333Floor Panel · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL BS 1320-1420 WL 208 HAS 2 MISSING INSERTS. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1 AND EO B757-5320-9692-G.SDR IPXA1565322Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1020 TO BS 1054, RBL 26 TO RBL 45 HAS EDGE DAMAGE, LOOSE INSERTS. FABRICATED FLOORBOARD BS 1020 TO BS 1054, RBL 26 TO RBL 45 IAW EO NR B757-5320-9692-G, SRM 53-00-50-1A.SDR IPXA1565321Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1020 TO BS 1054, RBL 46 TO RBL 61 HAS EDGE DAMAGE, AND LOOSE INSERTS. FABRICATED FLOORBOARD BS 1020 TO BS 1054, RBL 46 TO RBL 61 IAW SRM 53-00-50-1A, EO B757-5320-9692-G.SDR IPXA1565320Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1100 TO BS 1200, RBL 26 TO RBL 45 HAS EDGE DAMAGE. FABRICATED FLOORBOARD BS 1100 TO BS 1200, RBL 26 TO RBL 45 IAW SRM 53-00-50-1A, EO NO B757-5320-9692.SDR IPXA1565319Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD BS 1100 TO BS 1200, RBL 46 TO RBL 61 HAS EDGE DAMAGE, AND LOOSE INSERTS. FABRICATED FLOORBOARD BS 1100 TO 1200, RBL 46 TO RBL 61 IAW SRM 53-00-50-1A, EO B757-5320-9692.SDR IPXA1565318Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 1055-1100, LBL 25-45, WL 208 HAS EDGE DAMAGE. FABRICATED FLOOR PANEL BS 1055-1100, LBL 25-45, WL 208 IAW SRM 53-00-50-1A, EO B757-5320-9692.SDR IPXA1565314Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRRODED AT BS 1680, RBL 2.5-16.5, WL 208, BLENDED CORROSION.SDR IPXA1565313Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1681, LBL 40, WL 208, BLENDED CORROSION.SDR IPXA1565312Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1715, LBL .5, WL 208, BLENDED CORROSION.SDR IPXA1565311Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1714.5, RBL .5, WL 208, BLENDED CORROSION.SDR IPXA1565310Shear Web · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS CORRODED AT BS 1715, RBL 36, WL 208. BLENDED CORROSION.SDR IPXA1565309Shear Web · gougedINSPECTION TYPE:C3, MAIN CARGO BAY AFT SHEAR WEB UPPER SURFACE IS GOUGED AT BS 1682-1715 BL 0, WL 208. BLENDED GOUGE.SDR IPXA1565308Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL 1100-1200, LBL 0-25, WL 208 HAS DAMAGE. FABRICATED NEW FLOOR BOARD.SDR IPXA1565307Floor Panel · crackedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 900-1200, LBL 45-60, WL 208 IS CRACKED. FABRICATED NEW FLOORBOARD.SDR IPXA1565306Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1320-1420, RBL 0-25, WL208 IS DAMAGED FABRICATED NEW FLOORBOARD.SDR IPXA1565305Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1200-1320, LBL 0-25, WL208 IS DAMAGED FABRICATED NEW FLOORBOARD.SDR IPXA1565304Floor Panel · crackedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1540-1600, RBL 45-63, WL208 IS CRACKED. FABRICATED NEW FLOOR BOARDSDR IPXA1565294Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 440 TO 480 LBL 46 TO LBL 61 HAS AREAS OF DELAMINATION AND EDGE DAMAGE. REPLACE PANEL IAW B757-5320-9692G.SDR IPXA11565186Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY 1540 FLOORBEAM UPPER AFT FLANGE IS CORRODED AT LBL 37, WL 208. VALIDATED REPAIR IAW SRM 53-60-51-1A, FIG 1 AND 53-00-51-1A, FIG 101. REMOVED CORROSION L1.75" X 2.0"W X .002" D ORIGINAL THK .220", REMAINING THK .218" AT BS 15SDR IPXA11565185Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE HAS CORROSION AT STA 719, LBL 1. VALIDATED REPAIR IAW SRM 53-00-51-1A-1. REMOVED CORROSION 15" W X 1.5"L ORIGINAL THK .220", REMOVED .022" REMAINING THK .198" AT BS 720, RBL 27 TO RBL 42 IAW 51-10-02SDR IPXA11565184Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE HAS CORROSION AT STA 719, LBL 1. VALIDATED REPAIR IAW SRM 53-00-52-1A-1, FIG 101 AND 53-30-52-01. REMOVED CORROSION 1" X 1.73" X .067" ORIGINAL THK .070+.02-.00", REMOVED .023" REMAINING THK .067" ASDR IPXA11565183Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1681 FLOORBEAM NUT PLATE STRAP IS CORRODED RBL 52, WL 207 ON FWD UPPER FLANGE LOWER SIDE. AFTER INVESTIGATION NO ALLOWABLE DAMAGE AVAILABLE IN SRM FOR NUT PLATE STRAP. REMOVED NUT PLATE STRAP AT BS 1681, RBL 52, WL 207 ISDR IPXA11565182Floorbeam · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY BS 1540 FLOORBEAM UPPER AFT FLANGE IS CORRODED RBL 36.5 AND 40 WL 208. VALIDATED REPAIR IAW SRM 53-60-51-1A, FIG 1 AND 53-00-51-1A, FIG 101. REMOVED CORROSION L2.5" X 1.5" WX.002D ORIGINAL THICKNESS .220". REMAINING THICKNESDR IPXA1565827Support Bracket · damagedINSPECTION TYPE:C3, RT WING T/E - INBD MAIN FLAP - LOWER SURFACE - JUST INBD OF OTBD FLAP TRACK - FAIRING SUPPORT BRACKET HAS FRETTING DAMAGE. R & R BRACKET IAW ATS ER 11-01898.SDR IPXA11566031Panel · gougedINSPECTION TYPE:C3, PANEL NR 666BR IS GOUGED ON INTERNAL SIDE (MARKED). REPAIRED IAW ATS ER 11-01823 DATED 4-8-11, EO B757-5750-42137, A DATED 4-11-11, DWG 113N3500, SRM 51-30-01, SRM 51-40-08.SDR IPXA1565839Door Frame · damagedINSPECTION TYPE:C3, MAIN CARGO DOOR, MECHANICAL DAMAGE ON FRAME BS 529, WL 217, AND 222. REPAIRED FRAME IAW ER NR 11-01807 AND UPS EO B757-5230-42080-A.SDR IPXA11565479Web · gougedINSPECTION TYPE:C3, VERTICAL WEB IS DENTED AND GOUGED IN THE MAIN E BAY 4.5" ABOVE THE DOOR LATCH PLATE AT BS 468, RBL 8, WL 157. REMOVED DAMAGED PART & FABRICATED REPLACEMENT & INSTALLED IAW SRM 51-40-2 & DWG NR 284N1038, REV BF.SDR IPXA11565476Door Frame · damagedINSPECTION TYPE:C3, MAIN CARGO DOOR, MECHANICAL DAMAGE ON FRAME BS 484, WL 217 AND 222. FABRICATED FRAME DOUBLER AND INSTALLED IAW SRM 52-30-02-1A, SRM 51-40-02-0G, DWG 65-25327, SRM 51-20-01-0G.SDR IPXA1565339Bracket · crackedINSPECTION TYPE:C3, APU FIRE BOTTLE MOUNT BRACKET IS CRACKED. R & R BRACKET IAW SRM 51-40-02.SDR IPXA1565108Unknown · odorEMERGENCY DECLARED - INTERMITTENT HOT ELECTRICAL ODOR COMING FROM F/O'S SIDE OF FLIGHT DECK SEEMS TO BE COMING FROM THE INSTRUMENT PANEL AREA. REMOVED INSTRUMENT PANEL, SPEAKER AND 02 REGULATOR FROM F/O SIDE. VISUAL INSP OF WIRING INDICATES NO FAULTS. REINSTSDR IPXA11565520Floor Support · corrodedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 1180 TO 1200, LBL 24 FLOOR SUPPORT HAS LIGHT CORROSION AT FASTENER HOLES SPLICED IN NEW FLOOR SUPPORT IAW SRM 53-00-52-2R-5.SDR IPXA1565036Strap · corrodedINSPECTION TYPE:C2, FOUND APU INLET DOOR HOUSING CUTOUT AFT STRAP CORRODED. FABRICATED AND REPLACED STRAP IAW ER 11-01645.SDR IPXA1565718Floorbeam · corrodedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 1681, LBL 42" TO LBL 54" FLOOR HAS CORROSION. REMOVED CORROSION ORIGINAL THICKNESS .071 LOSS .013 WITH .058 REMAINING IS OUT OF LIMITS IAW SRM 53-00-51-1A . ACCOMPLISHED BLEND REPAIR FOR EXTENDED LIMITS IAW EASDR IPXA11565518Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 560 TO 620, RBL 46 TO RBL 61 IS PUNCTURED AND CRACKED. REPLACED FLOORBOARD.SDR IPXA11565484Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 340 TO 440, LBL 1 TO LBL 24 HAS NUMEROUS PUNCTURES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11565482Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1060 TO 1100, BL 0 TO LBL 2 AFT EDGE DAMAGED, CRUSHED, FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11565449Floor Panel · damagedINSPECTION TYPE:C4 MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 879 TO 900 RBL 26 TO RBL 45 HAS DAMAGE REPLACED PANEL PER B757-5320-9692-GSDR IPXA11565447Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 780 TO 820 RBL 46 TO RBL 61 HAS EDGE DAMAGE AND BROKEN CORNER. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1565331Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 820 TO 879, RBL 46 TO RBL 61 HAS SEVERAL PUNCTURES. REPLACED PANEL IAW EO B757-5320-9692G.SDR IPXA1565330Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 340 TO 440, RBL 1 TO RBL 24 HAS AREAS OF EDGE DAMAGE. REPLACED PANEL IAW EO B757-5320-9692G.SDR IPXA1565329Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 620 TO 720, LBL 46 TO LBL 61 HAS A BROKEN CORNER AND A DRILLED OFF SCREW. REPLACED PANEL IAW EO B757-5320-9692G.
Back to Boeing 757-24APF