Boeing 757-24APF

Service difficulty reports · 16,067

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '75724APF'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA11565458Frame · damagedINSPECTION TYPE:C3, BS 500, FRAME HAS A PREVIOUS OVERSIZED HOLE THAT REQUIRES REPAIR JUST ABOVE STR 14R IN WEB OF FRAME. REPAIRED BS 500 FRAME IAW SRM 53-00-07-2R-1.Mar 8, 2011 · N404UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1565442Support · corrodedINSPECTION TYPE:C3, ACB FLOOR TO SIDEWALL SUPPORT IS CORRODED AROUND NUTPLATE HOLES BS 1530-1630, RBL 19. REMOVED FASTENERS IN BLEND AREA, BLENDED CORROSION, UT FOR REMAINING THICKNESS, FOUND TO BE OUT OF LIMITS, R & R IAW EO B757-5310-32833-B, SRM 51-40-05, Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565436Panel · corrodedINSPECTION TYPE:C3, RT SIDE PANEL IS CORRODED BS 1200 TO 1310. R & R IAW SRM 51-40-02.Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA1565431Skin · delaminatedINSPECTION TYPE:C3, RT WING INBD MAIN FLAP HAS DELAMINATION ON UPPER SURFACE AT 11" FROM T/E, 103.5" FROM INBD END. REPAIRED DELAMINATED SKIN AND REPLACED CORE TO FULL DEPTH IAW SRM 51-70-07-0G.Mar 8, 2011 · N462UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA1565408Angle · damagedINSPECTION TYPE:C3, MAIN CARGO DOOR FRAME HAS A SCREW STRIKE BS 487, 5 INCHES ABOVE THE LOWER BEAM. REMOVED, FABRICATED AND INSTALLED NEW ANGLE IAW SRM 51-40-02 AND DWG 65-25327.Mar 8, 2011 · N462UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA1565391Cargo Track · corrodedINSPECTION TYPE:C3, ACB CARGO TIE DOWN IS CORRODED AT BS 1460, RBL 22. REPLACE IAW SRM 51-40-02-0G.Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565390Cargo Track · corrodedINSPECTION TYPE:C3, ACB CARGO TIE DOWN IS CORRODED AT BS 1540, RBL 20. REPLACE IAW SRM 51-40-05-0G.Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565386Cargo Track · corrodedINSPECTION TYPE:C3, CORROSION ON ACB TIE DOWN BS 1580, RBL 20. REPLACE IAW SRM 51-40-05-0G.Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565372Support · corrodedINSPECTION TYPE:C3, AFT CARGO BAY - RT FLOOR TO SIDEWALL SUPPORT - CORROSION AROUND CARGO TIE DOWN POINTS ON 2ND FROM FWD SEGMENT BS 1310 TO 1380 REMOVED AND REPLACED IAW SRM 51-40-02.Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1565345Cargo Track · corrodedINSPECTION TYPE:C3, ACB CARGO TIE-DOWN IS CORRODED AT BS 1520, RBL 21. R & R IAW SRM 51-40-02.Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565332Cargo Track · gougedINSPECTION TYPE:C3, ACB CARGO TIE-DOWN IS GOUGED AT BS 1580 LBL 20. R & R FITTING IAW SRM 51-10-02-0G, 51-40-02-0G, AMM 25-50-02-4.Mar 8, 2011 · N462UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565328Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 440 TO 480, RBL 1 TO RBL 26 FLOORBOARD HAS DELAMINATION AND BROKEN EDGES. REPLACED FLOORBOARD REF EO B757-5320-9692G.Mar 8, 2011 · N455UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565744Flange · chafedINSPECTION TYPE:C3, NR 1 PYLON OTBD SIDE AFT MOUNTING FLANGE FOR PANEL 433FL IS CHAFED PPS 257. REMOVED, FABRICATED AND INSTALLED NEW NR 1 PYLON OTBD SIDE AFT MOUNTING FLANGE IAW SRM 51-10-02, SRM 51-40-05, SRM 51-40-08 AMM 51-21-10-7 AND BAC DWG 313N5022.Mar 7, 2011 · N462UP · Boeing 75724APF · Nacelle/Pylon, Attach FittingsSDR IPXA11565556Skin · crackedINSPECTION TYPE:C3 NR 1 SLAT COVE SKIN IS CRACKED AT THE INBD MAIN FLAP TRACK FITTING. R & R SKIN IAW SRM 51-40-02.Mar 7, 2011 · N462UP · Boeing 75724APF · Leading Edge DevicesSDR IPXA11565555Skin · crackedINSPECTION TYPE:C3 NR 2 SLAT COVE SKIN IS CRACKED AT THE INBD MAIN FLAP TRACK FITTING. R & R SKIN IAW SRM 51-40-02.Mar 7, 2011 · N462UP · Boeing 75724APF · Wing, Plate/SkinSDR IPXA1565841Floorbeam · damagedINSPECTION TYPE:C3, MCB FLOORBEAM HAS AREAS OF MECHANICAL DAMAGE ON UPPER SURFACE, BS 1100, WL 208, LBL 2 TO LBL 40 (MARKED). REPAIRED FLOORBEAM IAW ER 11-01830 AND EO B757-5310-42081-A.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA1565840Floorbeam · gougedINSPECTION TYPE:C3, MAIN CARGO BAY THE UPPER FLANGE OF THE BS 1200 FLOORBEAM IS GOUGED LBL 60-RBL 60, WL 208. REPAIRED FLOOR BEAM IAW ATS WE11-01829 AND EO B757-5310-42083-A.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA1565822Seat Track · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FITTING ON TOP OF THE SEAT TRACK IS GOUGED ON THE OTBD AND INBD SIDE BS 1675-1681, RBL 45, WL 208. REPAIRED IAW ER 11-01851, DATED 28MAR11 AND EO B757-5310-42064-A DATED 29MAR11.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565821Seat Track · gougedINSPECTION TYPE:C3, MAIN CARGO BAY FITTING ON TOP OF THE SEAT TRACK IS GOUGED ON THE OTBD SIDE BS 1675-1681, RBL 25, WL 208. REPAIRED FITTING IAW ER 11-01851, DATED 28MAR11 AND EO B757-5310-42064A, DATED 29MAR11.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565785Seat Track · damagedINSPECTION TYPE:C3, MCB SEAT TRACK HAS MECHANICAL DAMAGE BS 1080-1180 AND A CRACK AT BS 1080, LBL 0.7, WL 208 (MARKED). REPLACED SEAT TRACK IAW SRM 51-40-02 AND DWG 144N5024.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565751Seat Track · damagedINSPECTION TYPE:C3, MCB TRACK SUPPORT HAS MECH DAMAGE ON UPPER SURFACE ADJACENT TO SEAT TRACK, BS 1040-1076, LBL 1, WL 208 (MARKED). REPLACED TRACK SUPPORT IAW SRM 51-40-02 AND DWG 144N8031.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565750Seat Track · gougedINSPECTION TYPE:C3, MAIN CARGO BAY LBL 45 SEAT TRACK INBD AND OTBD FLANGES ARE GOUGED BS 1200, WL 208. REPAIRED SEAT TRACK BS 1180-1230 IAW SRM 53-00-52-2R 5 AND UPS EO B757-5340-20264-C.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565740Seat Track · damagedINSPECTION TYPE:C3, SEAT TRACK HAS MECHANICAL DAMAGE BS 1073 TO BS 1100 RBL 25.5 REPLACED SEAT TRACK IAW SRM 51-40-02 AND DWG 144N5002 AND DWG 144N5024.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565739Seat Track · damagedINSPECTION TYPE:C3, SEAT TRACK HAS MECHANICAL DAMAGE BS 1080-1180 AND A CRACK AT BS 1079, LBL 0.7, WL 208 (MARKED). REPLACED SEATY TRACK IAW SRM 51-40-02 AND DWG 144N5024.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565735Skin · dentedINSPECTION TYPE:C3, DENT IN EMPENNAGE SKIN AT BS 1979, 12 O'CLOCK POSITION. REPAIRED IAW ER 11-01822 AND EO B757-5330-42031-A.Mar 6, 2011 · N462UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA1565732Floorbeam · corrodedINSPECTION TYPE:C3, FLOOR SUPPORT HAS CORROSION ON UPPER SURFACE, BS 1055, LBL46-57, WL 208. R & R FLOOR SUPPORT IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA1565731Seat Track · damagedINSPECTION TYPE:C3, MAIN CARGO BAY RBL 45 SEAT TRACK INBD FLANGE HAS A DRILL START BS 1197 WL 208. REPLACED SEAT TRACK IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1565722Floorbeam · damagedINSPECTION TYPE:C3, FLOORBEAM HAS MECHANICAL DAMAGE BS 1054 RBL 1 TO RBL 24. R & R FLOORBEAM IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA1565721Floorbeam · damagedINSPECTION TYPE:C3, FLOORBEAM HAS MECHANICAL DAMAGE BS 1020 RBL 1 TO RBL 24 R & R FLOORBEAM IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA1565720Floorbeam · damagedINSPECTION TYPE:C3, FLOORBEAM HAS MECHANICAL DAMAGE BS 1020, RBL 25.5 TO RBL 44.5. R & R FLOORBEAM IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA1565715Seat Track · damagedINSPECTION TYPE:C3, SEAT TRACK HAS MECHANICAL DAMAGE BS 1073 TO 1100 RBL 44.5. MECHANICAL DAMAGE FOUND TO BE OUT OF LIMITS. R & R IAW SRM 53-40-52-0I 1, SRM 53-00-52-1A 1 SRM 51-40-05, SRM51-20-01, SRM51-40-02 AND DWG 144N5024.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565652Seat Track · corrodedINSPECTION TYPE:C3, MCB SEAT TRACK CORRODED AT 4EA NUTPLATE LOCATIONS ON INBD FLANGE, BS 1083 TO BS 1096, LBL 44, WL 208. REPLACED PART IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565651Seat Track · corrodedINSPECTION TYPE:C3, MCB SEAT TRACK CORRODED AT 4 EA NUTPLATE LOCATIONS ON INBD FLANGE, BS 1083 TO BS 1096, LBL 44, WL 208. REPLACED PART IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565650Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY LBL 45 SEAT TRACK INBD AND OTBD FLANGES CORRODED BS 1674, WL 208. REPLACED PART IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565649Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY, LBL 45, SEAT TRACK INBD AND OTBD FLANGES CORRODED BS 1674, WL 208. REPLACED PART IAW SRM 51-40-02-06.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565642Intercostal · corrodedINSPECTION TYPE:C3, CORROSION ON FLOOR INTERCOSTAL, SEVERAL AREAS ON UPPER SURFACE BA 310- BS 324. WL 208 LBL60. REPLACED PART IAW SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11565641Intercostal · corrodedINSPECTION TYPE:C3, CORROSION ON FLOOR INTERCOSTAL, SEVERAL AREAS ON UPPER SURFACE BS 297-310, WL 208, LBL60. REPLACED PART IAW SRM 51-40-2.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11565606Floor Support · crackedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SUPPORT UPPER ANGLE CRACKED AT STA 840-860, LBL 16. FOUND TO BE OUT OF LIMITS, REMOVED, REFABRICATED & REINSTALLED REPLACEMENT PART IAW SRM 51-20-01, AMM 51-21-00-7 & SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11565605Floor Support · crackedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SUPPORT UPPER ANGLE CRACKED STA 840 TO 860 RBL 16. FOUND TO BE OUT OF LIMITS, REMOVED, REFABRICATED & REINSTALLED REPLACEMENT PART IAW SRM 51-20-01, AMM 51-21-00-7 & SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11565580Cargo Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE CORROSION AT STA 681 RBL 26. REMOVED OLD SEAT TRACK, FABRICATED NEW SEAT TRACK AND INSTALLED IAW SRM 53-00-52-1A-1, 53-30-52-01I, 51-10-02-0G, 51-40-02-0G, 51-40-05-06, 51-40-08-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565578Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE HAS CORROSION AT STA 750 TO 770, RBL 44. R & R SEAT TRACK IAW SRM 53-30-52-0I, SRM 53-00-52-1A 1, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-40-08-OG, SOPM 20-41-02, SRM 51-20-01-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565566Seat Track · corrodedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR SEAT TRACK FLANGE HAS CORROSION AT STA 580, LBL 24. R & R SEAT TRACK IAW SRM 53-30-52-0I, SRM 53-00-52-1A, SRM 51-40-02-0G, SRM 51-40-05-0G, DWG 143N5278, AMM 51-24-13-7, DWG 143N5273.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565562Seat Track · damagedINSPECTION TYPE:C3, MCB SEAT TRACK HAS MECHANICAL DAMAGE ON UPPER SURFACE, BL 0, BS 1020 WL 208 (MARKED). R & R SEAT TRACK IAW SRM 53-00-52 1A1, SRM 51-40-02-0G, SRM 51-20-01-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA11565489Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1420-1540, LBL 45-60 WL 208 HAS 12 DAMAGED INSERTS. FABRICATED MCB FLOOR PANEL.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11565475Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1600-1681, RBL 45-60, WL 208 AFT OTBD CORNER IS DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11565472Beam · damagedINSPECTION TYPE:C3, MCB LONGITUDINAL BEAM HAS MECH DAMAGE ON UPPER SURFACE ADJACENT TO SEAT TRACK, BS 1040-1074, LBL 24, WL MARKED. REPLACED LONGITUDINAL BEAM IAW SRM 51-21-04-7, SRM 51-40-02-0G, SRM 53-40-51-0I.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA11565471Beam · damagedINSPECTION TYPE:C3, LONGITUDINAL BEAM HAS MECHANICAL DAMAGE BS 1054 TO 1073, RBL 25.5. R & R WITH NEW PART IAW DWG NR144N8017 AND SRM 51-40-02-0G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA1565438Beam · damagedINSPECTION TYPE:C3, LONGITUDINAL BEAM HAS MECHANICAL DAMAGE BS 1054 TO BS 1073, RBL 44.5. REPLACED PART IAW SRM 51-40-02 & DWG 144N8017.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA1565409Floor Panel · crackedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL BS 1681-1716, BL 0-RBL 57, WL 208 HAS THE AFT OTBD CORNER CRACKED. FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-G.Mar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1565354Floor Support · corrodedINSPECTION TYPE:C3, LONGITUDINAL BEAM HAS CORROSION ON UPPER SURFACE AT NUTPLATE LOCATIONS BS 1034, LBL 1.25, WL 208. BLENDED CORROSION IAW SRM 51-10-02-0G IN A 1.5X1.1X.009 FOUND TO BE WITHIN LIMITS ALODINED & REFINISHED IAW SRM 53-00-51-1A & SRM 51-20-01-0GMar 6, 2011 · N402UP · Boeing 75724APF · Fuselage Miscellaneous Structure
Back to Boeing 757-24APF