SDR IPXA1564952Skin · dentedINSPECTION TYPE:C2, FUSELAGE EXTERNAL SKIN DENT, BS 1595, JUST BELOW STR 4R, LAP. DENT TO BE REPAIRED ON CARD NR925118 IN CONJUCTION WITH AND ADJACENT DENT.SDR IPXA11564920Skin · chafedINSPECTION TYPE:2C14, NR 3 SLAT EXTERNAL LOWER SKIN T/E CHAFED AT SEVERAL AREAS. REMOVED DAMAGE 2.7" X .7" AND HOT BOND REPAIRED IAW SRM 51-70-10.SDR IPXA11564911Support Bracket · crackedINSPECTION TYPE:C1, CRACKED CEILING SUPPORT BRACKET BS 520, BL 0, WL 202, IN FWD CARGO BAY. R & R BRACKET IAW SRM.SDR IPXA1564813Floor Panel · delaminatedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS DELAMINATED ON UPPER SURFACE BS 1016-1055, LBL 25-45. FABRICATED REPLACEMENT FLOOR PANEL IAW EO 757-5320-9692-G.SDR IPXA1564812Floor Panel · delaminatedINSPECTION TYPE:C2, FLOOR PANEL NR 242XDF AFT EDGE DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1564811Floor Panel · delaminatedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS DELAM ON UPPER SURFACE BS 1020-BS 1055, LBL 45-60. FABRICATED REPLACEMENT PANEL IAW EO 757-5320-9692-G.SDR IPXA1565044Door Frame · wornINSPECTION TYPE:C2, RT APU DOOR NR 316AR FWD INNER FLANGE WORN AT OTBD EDGE. R & R FRAME IAW SRM 51-40-05-0G, SRM 51-20-01-0G AND AMM 51-20-00-0.SDR IPXA1564965Handle · gougedINSPECTION TYPE:C2, FWD CARGO DOOR EXTERNAL HANDLE, INNER SURFACE GOUGED AT SEVERAL PLACES, 3" FROM AFT END, MARKED. BLENDED GOUGED AREA ON LOWER LIP OF CARGO DOOR EXTERNAL HANDLE INTERNAL SURFACE 2"X .7" X .020" IAW EO NR B757-5230-36432-UPS, FIG 1. FOUND RSDR IPXA11564850Access Panel · damagedINSPECTION TYPE:MOD, NR 2 PYLON UNDERWING FAIRING STRUCTURE, OTBD AFT ACCESS PANEL NR 443ER HAS A DAMAGED FASTENER HOLE, LOCATED AT THE FWD LWR CORNER P/N 313N5004-4. FABRICATED NEW ACCESS PANEL NR 443ER IAW SRM 51-40-05-0G, SRM 51-40-08-0G, DWG 313N5004, AMMSDR IPXA1564724Sill · damagedINSPECTION TYPE:C1, FWD ENTRY DOOR SILL WEB ASSY HAS SEVERAL SCREW STRIKES AT BS 297-321. REMOVED DAMAGED WEB, FABRICATED AND INSTALLED NEW WEB, IAW SRM 53-10-15-1A.SDR IPXA1564699Frame · dentedINSPECTION TYPE:C3, AFT PIT STA 1300, RBL 26", FRAME DENTED REPAIRED IAW EA 110056 AND EO B757-5310-41366.SDR IPXA1564772Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO FLOOR PANEL MISSING INSERTS BS 1320-1420, LBL 25-45. FABRICATED NEW BOARD IAW EO 757-5320-9692-G.SDR IPXA1564774Angle · crackedINSPECTION TYPE:MOD NR1 PYLON AFT FAIRING STRUCTURE INBD AND OTBD NUT PLATE. SUPPORT BRACKETS ABOVE DRAIN LINES ARE CRACKED. R & R INBD AND OTBD SUPPORT BRACKETS IAW SRM 51-40-02-0G.SDR IPXA1564802Support Bracket · crackedINSPECTION TYPE:MOD, NR2 PYLON AFT FAIRING STRUCTURE INBD AND OTBD NUTPLATE SUPPORT BRACKETS ABOVE DRAIN LINES ARE CRACKED AND WORN. R & R BOTH INBD AND OTBD NUTPLATE SUPPORT BRACKETS IAW SRM 51-40-02-0G.SDR IPXA1564727Floorboard · damagedINSPECTION TYPE:C1, MAIN CARGO FLOORBOARD. BS 560-620, LBL 45-65 HAS MISSING INSERT. REPLACED FLOORBOARD ASSY IAW EO B757-5320-9692-G, SRM 53-00-50-1A1.SDR IPXA1564719Floor Panel · delaminatedINSPECTION TYPE:C1 MAIN CARGO FLOOR PANEL BS 338-440 RBL 25 IS DELAMINATED AND HAS MISSING INSERTS. REPAIRED IAW EO B757-5320-9692-G, DATED: 04/15/2009.SDR IPXA1564718Floor Panel · delaminatedINSPECTION TYPE:C1, FLOOR PANEL, BS 333-440 LBL 25, HAS DELAMINATION ON LOWER SURFACE AND A MISSING INSERT. REPAIRED IAW EO B757-5320-9692-G, DATED 04/15/2009.SDR IPXA1564776Casting · mismanufacturedINSPECTION TYPE:4C12, WHILE WORKING CUSTOMER CARD NR 915055 (716941), FOUND THE MAIN CARGO DOOR FWD LIFT ACTUATOR CASTING TO HAVE EXISTING FASTENER HOLES THAT ARE NOT DRILLED PERPENDICULAR TO THE SURFACE. R & R IAW SRM 51-40-02-0G, SECTION 1 THRU 9, DWG 65-2SDR IPXA1564775Casting · mismanufacturedINSPECTION TYPE: 4C12, WHILE WORKING CC 915055 (916741) FOUND THE MAIN CARGO DOOR AFT LIFT ACTUATOR CASTING TO HAVE EXISTING FASTENER HOLES THAT ARE NOT DRILLED PERPENDICULAR TO THE SURFACE. R & R IAW SRM 51-40-026G, SECTION 1 THRU 9 & DEG 65-25327.SDR IPXA1565070Floorboard · brokenINSPECTION TYPE:C3, CORNER OF FLOORBOARD IS BROKEN AT BS 1187, LBL 65. REPLACED IAW EO B757-5320-9692-G.SDR IPXA1564950Fitting · corrodedINSPECTION TYPE:MOD, NR 1 PYLON MID SPAR FITTING ON THE ACFT INBD SURFACE AROUND THE BUSHING IS PITTED AND WORN. REPAIRED FITTING IAW EO B757-5440-41606-A, DATED 24 FEB 2011 AND ATS ER 11-01495, DATED 23 FEB 11.SDR IPXA1564949Fitting · gougedINSPECTION TYPE:MOD, NR 1 PYLON INBD MID SPAR FITTING ON ACFT INBD AND OTBD SURFACE AROUND THE BUSHING ARE WORN AND GOUGED. REPAIRED FITTING IAW EO B757-5440-41606-A AND ER 11-01495.SDR IPXA1564947Skin · chafedINSPECTION TYPE:MOD, RT WING LOWER SKIN AT FSS 295 IS CHAFED FROM 7-14 INCHES AFT OF THE SKIN L/E. REPAIRED IAW SRM 57-20-01-1A1, EO B757-5730-41559-A, DATED 23 FEB 2011, AND ATS ER 11-01575 DATED 23 FEB, 2011.SDR IPXA1564946Skin · chafedINSPECTION TYPE:MOD, LT WING LOWER SKIN IS CHAFED AT FSS 295, FROM 2-14 INCHES AFT OF THE SKIN L/E. REPAIRED IAW SRM 57-20-01-1A1, ATS ER 11-01575, DATED 23, FEB 2011, EO B757-5730-41559-A DATED 23, FEB 2011.SDR IPXA11564860Support · wornINSPECTION TYPE:MOD, NR 2 PYLON AFT FAIRING STRUCTURE FWD INBD UPPER NUT PLATE SUPPORT WORN AROUND LOWER NUT PLATE. FABRICATED NEW FWD INBD UPPER NUT PLATE SUPPORT IAW SRM 54-50-71-1A1, SRM 51-30-01-0G, SRM 51-40-05-0G, AMM 51-21-11-7, AMM 51-21-10-7.SDR IPXA11564848Support · wornINSPECTION TYPE:MOD, NR 2 PYLON AFT FAIRING STRUCTURE FWD OTBD UPPER NUTPLATE SUPPORT WORN AROUND NUTPLATES. REMOVED, FABRICATED AND INSTALLED NEW NUTPLATE SUPPORT IAW SRM 54-50-70-1A1, SRM 51-40-02-0G, SRM 51-40-05-0G, AMM 51-21-10-7, AMM 51-21-11-7.SDR IPXA1564773Skin Panel · crackedINSPECTION TYPE: MOD, NR2 PYLON AFT FAIRING STRUCTURE LOWER AFT CLOSE-OUT SKIN CRACKED ABOVE DRAIN LINE. R & R LOWER AFT CLOSE-OUT SKIN IAW SRM 51-40-02-0G.SDR IPXA1564748Fairing · gougedINSPECTION TYPE:MOD, NR1 PYLON AFT FAIRING STRUCTURE FWD INBD UPPER NUTPLATE SUPPORT IS WORN AROUND NUTPLATES. REMOVED, FABRICATED, AND INSTALLED IAW DWG NR313N5033, AND SRM 51-40-02.SDR IPXA1564786Skin · crackedINSPECTION TYPE:MOD, NR1 PYLON AFT FAIRING STRUCTURE LOWER T/E SKIN PANEL IS CRACKED ABOVE DRAIN LINES. R & R SKIN PANEL IAW SRM 51-40-02-0G.SDR IPXA1565012Floorbeam · damagedINSPECTION TYPE:C1, FLOORBEAM STA 900, RBL 25-45 HAS MECH DAMAGE. R & R FLOORBEAM IAW SRM.SDR IPXA1564951Shear Web · corrodedINSPECTION TYPE:C1, SEVERAL AREAS OF CORROSION ON SHEAR WEB (MARKED) AT BS 440-BS 660, LBL 45-LBL 60, WL 208. REPAIRED IAW SRM 51-10-02-0G, SRM 53-30-15-0I1, SRM 51-40-02-0G, ATS ER NO 11-01491 DATED 2/24/2011, AND EO B757-5310-41615-A, DATED 02/24/11.SDR IPXA1564939Floorbeam · corrodedINSPECTION TYPE:C1, CORROSION ON BS 1681 FLOORBEAM, LBL 40 ON THE UNDERSIDE OF THE J FLANGE. REPAIRED IAW ATS ER 11-01477, DATED 2/24/11.SDR IPXA1564750Floorbeam · gougedINSPECTION TYPE:C1, FLOORBOARD SUPPORT AT STA 900, LBL 25-45, HAS MECHANICAL DAMAGE. R & R IAW SRM 51-40-02 AND DWG PL 144N5005.SDR IPXA1564749Floorbeam · corrodedINSPECTION TYPE:C1, FLOORBOARD SUPPORT AT STA 900, RBL 0-25, IS CORRODED. R & R IAW SRM 51-40-02 AND DWG PL 144N5005.SDR IPXA1564814Floorbeam · corrodedINSPECTION TYPE:C, CORROSION ON T-CHORD INBD FLANGE AT BS 324, LBL 60, WL 208. REPAIRED CHORD IAW EO 757-5310-41500-A AND ER 11-01476.SDR IPXA1564729Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 440 TO 480 LBL 45-60, DAMAGE FWD END OTBD SIDE MARKED. REPLACED FLOORBOARD IAW EO B757-5320-9692-9 AND SRM 53-00-50-2R1, SRM 53-00-50-1A1.SDR IPXA1564726Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 720-820, LBL 45-60, DAMAGE AT AFT END STA 800 MARKED. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, TABLE I AND EO B757-5320-9692-G.SDR IPXA1564720Intercostal · crackedINSP TYPE:C1, INTERCOSTAL CRACKED AT BS 857, LBL 16, WL 208. FABRICATED INTERCOSTAL AND INSTALLED IAW SRM 51-40-05-0G.SDR IPXA1564716Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD DAMAGED MID OTBD SIDE BS 480 TO 560, LBL 25-45. FABRICATED REPLACEMENT FLOORBOARD IAW EO NR B757-5320-9692.SDR IPXA11564655Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 879 TO 900 RBL 45-60, DAMAGED AT FWD END. R & R FLOORBOARD IAW EO 757-5320-9692G.SDR IPXA11564829Floorboard · damagedINSPECTION TYPE:C1, MISSING INSERT IN FLOORBOARD AT STA 1610, RBL44. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1564728Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD STA 1100 TO 1200, BL0 TO RBL 25, FWD END AND OTBD AFT END DAMAGED AND MARKED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G, SRM 53-00-50-1A1.SDR IPXA1564715Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD STA 1100 TO 1200, RBL 25 TO 45, FWD AND AFT ENDS DAMAGED AND MARKED. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA1564698Floorboard · damagedINSPECTION TYPE:C1, MISSING INSERT IN FLOORBOARD AT STA 1590, RBL44. REPLACED MCB FLOORBOARD AT BS 1540-1600, RBL 44, IAW EO B757-5320-96 92-G.SDR IPXA11564635Floorboard · damagedINSPECTION TYPE:C1 FOUND FLOORBOARD AT STA 1055-1100, RBL 25-45, OTBD SIDE DAMAGED (MARKED) AND MISSING INSERT. R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564634Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 1020-1055, RBL 45-60, AFT END DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD ANEL IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564633Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 900-1020, BL 0- LBL 25, FWD CORNER DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564632Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 900-1120, RBL 25-45, FWD CORNER DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564631Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 900-1020, LBL 45-60, OTBD SIDE DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5820-9692-G.SDR IPXA1564940Skin · gougedINSPECTION TYPE:C1, LT FUSELAGE SKIN GOUGED FROM LOWER STAB SEAL AT BS 1861 JUST ABOVE STRINGER 17. REPAIRED IAW ATS ER 11-01526, DATED 2/21/11.
Back to Boeing 757-24APF