SDR IPXA10563431Stringer Clip · damagedINSPECTION TYPE:C4, RCD PURBPSE: FABRICATE STRINGER CLIP FOR BS 1560; STR 25 USING ALTERNATE MATERIAL IAW ER 10-05132. REPAIRED IAW ATS ER 10-05132, DATED 10-27-10.SDR IPXA10563390Floor Panel · misrepairedINSPECTION TYPE:C4, FABRICATE NEW FLOOR PANEL TO ACCOMODATE FLOOR BEAM ATTACH FASTENERS ON BS 1100 BEAM, RELOCATED BY BEAM REPAIR BS 1055-BS 1100 BL0- RBL 25. REPLACED FLOOR PANEL IAW B757-5320-9692-G; EO B757-5100-33281-B.SDR IPXA10563389Floor Panel · misrepairedINSPECTION TYPE:C4, FABRICATE NEW FLOOR PANEL TO ACCOMODATE FLOORBEAM, ATTACH FASTENERS ON BS 1100 BEAM, RELOCATED BY BEAM REPAIR BS 1055-1100 BL0- LBL 25. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G; EO B757-5100-33281-B.SDR IPXA10563326Bracket · crackedINSPECTION TYPE:C4, BRACKET AT BS 1700 BETWEEN STR 25L AND 26L IS CRACKED. REPLACED BRACKET IAW SRM 51-40-2.SDR IPXA10563251Compressor · stalledFLIGHT CREW REPORTED THAT ON TAKEOFF AT 400 FT THE LT ENGINE COMPRESSOR STALLED 6 OR 7 TIMES WITH SIGNIFICANT YAW. SUPPLEMENTAL ETOPS REPORT ACCOMPLISHED NR1 ENGINE. R & R IAW UPS TASK CARDS 5001(RR0, 5001-1 (RR) AND 5002RR.SDR IPXA10563514Floorbeam · corrodedINSPECTION TYPE:C4, FOR RCD PURPOSESW, BS 1200 FLOORBEAM REQUIRES REINFORCEMENT BETWEEN LBL 8 AND LBL 28, WL 208. REPAIRED IAW ATS ER 10-05127, DATED 30OCT2010.SDR IPXA10563513Floorbeam · corrodedINSPECTION TYPE:C4, FOR RCD PURPOSE SW BS 1200 FLOORBEAM REQUIRES REINFORCEMENT BETWEEN LBL 8 AND RBL 60, WL 208. REPAIRED IAW ER 10-05127, DATED 30OCT2010.SDR IPXA10563516Shear Web · corrodedINSPECTION TYPE:C4, MCB AFT SHEAR WEB UPR SURFACE HAS AREAS OF CORROSION BS 1680-1681, LBL 2.5-23, WL 208. REPAIRED SHEAR WEB UPR SURFACE IAW ER NR 10-05130.SDR IPXA10563264Floorboard · misrepairedINSPECTION TYPE:C4, FWD ENTRY FLOOR PANEL REQUIRES FABRICATION IAW ENGINEERING TO ADD STEPCUTS AT AREAS TO ACCOUNT FOR REPAIR DOUBLERS AT LBL26-33 AND LBL37-43 STA 323 TO EDGE OF PANEL. FABRICATED REPLACEMENT FLOOR PANEL WITH REQUIRED STEPCUTS IAW EO B757-532SDR IPXA10563458Structure · crackedINSP TYPE:C4, CREW ENTRY WAY GUTTER ASSY IS CRACKED ON THE AFT END. REPAIRED ENTRY WAY GUTTER ASSY IAW EO B757-5320-40392-A AND ATS ER 10-05209.SDR IPXA10563441Frame · dentedINSPECTION TYPE:C4, AFT CARGO BAY FRAME INNER FLANGE IS DENTED BS 1300, STR 26-27R. REPAIRED IAW ATS ER 10-04981, DATED 10-28-10.SDR IPXA10563029Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL ZONE 131 OTBD HAS DAMAGE TO EDGE. MFG AND INSTALLED NEW FLOOR PANEL IAW EO B757-5320-9692-G AND AMM-53-01-01.SDR IPXA10563028Floor Panel · damagedMAIN CARGO DECK ZONE 131 INBD FLOOR PANEL HAS DAMAGE TO EDGE, CRUSHED. MFG AND REPLACED FLOOR PANEL IAW EOB757-5320-9692-G AND AMM-53-01-01.SDR IPXA10563320Floor Panel · corrodedINSPECTION TYPE:C4, ACB NR 2 FLOOR PANEL IS CORRODED. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G & SRM 51-40-08-0G.SDR IPXA10563314Floor Panel · corrodedINSPECTION TYPE:C4, ACB NR 4 FLOOR PANEL IS CORRODED. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G AND SRM 51-20-01-0G.SDR IPXA10563313Floor Panel · corrodedINSPECTION TYPE:C4, ACB NR3 FLOOR PANEL IS CORRODED. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G AND SRM 51-20-01-0G.SDR IPXA10563286Floorboard · brokenINSPECTION TYPE:C4, MCB FLOOR PNL BS 1020-1060 LBL 25-45 HAS EDGE DAMAGE AND CORNERS ARE BROKEN. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563254Floor Panel · brokenINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1100-1200 LBL 45-65 WL 208 HAS BROKEN AND MISSING INSERTS. FABRCATED REPLACEMENT FLOOR PANEL PER UPS E.O. B757-5320-9692-GSDR IPXA10563246Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1100-1200, LBL 25-45, WL 208 HAS 3 AREAS OF EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563245Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1020-1060 LBL 45-65 WL 208 CORNER IS DAMAGED AND LOWER SURFACE IS PUNCTURED. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10563159Floorboard · puncturedINSPECTION TYPE:C4, MCB FLOOR PNL BS 1100-1200 BL 0-RBL25 UPR SURFACE PUNCTURED, 1 MISSING 1 BROKEN INSERT. FABRICATED FLOOR PANEL REPLACEMENT IAW EO B757-5320-9692-G.SDR IPXA10563101Floor Panel · brokenINSPECTION TYPE:C4 MAIN CARGO BAY FLOOR PANEL BS 900-1020, LBL 45 - 65, WL 208 HAS EDGE DAMAGE AND BROKEN END OF PANEL. FABRICATED REPLACEMENT PANEL IAW ER B757-5320-9692-G.SDR IPXA10563055Floor Panel · damagedINSPECTION TYPE:C4, MCB FLOOR PANEL, BS 900-1020 LBL 25-45 HAS EDGE DAMAGE AT CORNER. REPLACED FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10563539Stiffener · corrodedINSPECTION TYPE:C4, LAV PAN INNER AFT SUPPORT STIFFENER AT BS 360, STR 22R, RBL45 IS CORRODED (DAMAGE IS BEYOND SRM LIMITS). R & R DOUBLER IAW SRM 51-40-02.SDR IPXA10563529Floor Support · corrodedINSPECTION TYPE:C4, FRETTING DAMAGE ON FLOOR STRUCTURE COMMON TO FLOORBOARD ATTACHMENT HOLES BS 900 THROUGH 1005 LBL 23, WL 208. REPAIRED LONGITUDINAL BEAM IAW ER 10-05116 AND EO B757-5310-40439-A.SDR IPXA10563527Floor Support · corrodedINSPECTION TYPE:C4, CORROSION ON FLOOR STRUCTURE AT BS 1015, LBL 23.5, WL 208. REPAIRED LONGITUDINAL BEAM IAW ER 10-05116 AND EO B757-5310-40439-A.SDR IPXA10563521Shear Web · corrodedINSPECTION TYPE:C4, MCB AFT SHEAR WEB UPPER SURFACE HAS AREAS OF CORROSION BS 1705-1713, LBL 7-15, WL 208. REPAIRED SHEAR WEB IAW ER 10-05227 AND EO B757-5310-40446-A.SDR IPXA10563520Shear Web · corrodedINSPECTION TYPE:C4, MCB AFT SHEAR WEB UPR SURFACE HAS AREAS OF CORROSION BS 1712-1714, LBL 32-38. REPAIRED SHEAR WEB IAW ER 10-05130, EO B757-5310-38268-C.SDR IPXA10563517Shear Web · gougedINSPECTION TYPE:C4, MCB AFT SHEAR WEB UPR SURFACE HAS GOUGED AREA BS 1682.5-1713, BL 0, WL 208. REPAIRED SHEAR WEB IAW ER NR 10-05130.SDR IPXA10563454Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON FRAME CAP AT BS 1100 BETWEEN STR 15L AND 16L. REPAIRED FRAME CAP IAW EO B757-5310-40266-A ATS ER 10-05118.SDR IPXA10563237Seat Track · corrodedINSPECTION TYPE:C4, CORROSION ON SEAT TRACK FLOORBOARD ATTACHMENT HOLES AT BS 900 THRU 1030 RBL 60, WL 208. REPLACED SEAT TRACK IAW SRM 51-40-05-0G, SRM 51-40-08-0G, AND SRM 51-40-02-0G.SDR IPXA10563078Stringer Clip · brokenINSPECTION TYPE:C4, STRINGER 1 CLIP AT BS 330 END IS BROKEN OFF. R & R CLIP IAW SRM 51-40-02.SDR IPXA10563034Floor Support · corrodedINSPECTION TYPE:C4, CORROSION ON FLOOR SUPPORT AT BS 1020 LBL 52 WL 208 FABRICATED NEW FLOOR SUPPORT IAW SRM 51-40-05-0G, SRM 51-40-08-0G DWG 144N5081,SDR IPXA10563528Floor Support · corrodedINSPECTION TYPE:C4, BS 1020 TO 1040, LBL 25, FLOORBEAM CORRODED. REPAIRED LONGITUDINAL BEAM IAW ER 10-05116 AND EO B757-5310-40439-A.SDR IPXA10563526Shear Web · corrodedINSPECTION TYPE:C4, MCB AFT SHEAR WEB UPR SURFACE HAS AREAS OF CORROSION BS 1706-1711, RBL 11-17.5, WL 208. REPAIRED SHEAR WEB IAW ER 10-05227 AND EO B757-5310-40446-A.SDR IPXA10563522Shear Web · corrodedINSPECTION TYPE:C4, MCB AFT SHEAR WEB UPR SURFACE HAS AREA OF CORROSION BS 1697, RBL 24.5, WL 208. REPAIRED SHEAR WEB IAW ER 10-05227 AND EO B757-5310-40446-A.SDR IPXA10563519Shear Web · corrodedINSPECTION TYPE:C4, MCB AFT SHEAR WEB UPPER SURFACE HAS AREA OF CORROSION BS 1708, LBL 53, WL 208. REPAIRED SHEAR WEB IAW ER 10-05130, EO B757-5310-38268-C.SDR IPXA10563518Seat Track · corrodedINSPECTION TYPE:C4, BODY STATION 1196, BUTT LINE 0 CORRODED STRUCTURE AT NUTPLATE HOLES. REPAIRED IAW EO B757-5310-40443A AND ER 10-05178 DATED, 02-NOV-2010.SDR IPXA10563512Floorbeam · corrodedINSPECTION TYPE:C4, FLOORBEAM UPR SURFACE HAS CORROSION AROUND NUTPLATE HOLES BS1200, RBL65 TO LBL65. REPAIRED IAW ER 10-05127, DATED 30OCT2010.SDR IPXA10563511Floor Support · corrodedINSPECTION TYPE:C4, MCB FLOORBEAM STABILIZER STRAP HAS CORROSION ON UPPER SURFACE AT NUT PLATES BS1400-1420, RBL 45, WL201. REPAIRED IAW EO B757-5310-40425-A, DATED 01NOV10 AND ATS ER 10-05211, DATED 29OCT2010.SDR IPXA10563499Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION AT NUT PLATE HOLES FLOORBEAM BS 1100, BL0-25, WL208. REPAIR IAW ATS ER 10-05071, DATED 10-29-10.SDR IPXA10563492Floor Skin · corrodedINSP TYPE:C4, CORROSION ON FLOOR, AROUND BASE OF FO'S INBD FWD SEAT TRACK BS 240 TO 257. REPAIRED CORROSION DAMAGE IAW EO B757-5310-40356-A AND ER 10-05121.SDR IPXA10563491Floor Support · corrodedINSPECTION TYPE:C4, FLOORBEAM STABILIZER STRAP HAS CORROSION ON UPPER SURFACE AT NUT PLATES BS1400-1420, RBL 45, WL201. REPAIRED IAW EO B757-5310-40425-A DATED 01-NOV-10.SDR IPXA10563490Floor Support · corrodedINSPECTION TYPE:C4, FLOORBEAM STABILIZER STRAP HAS CORROSION ON UPPER SURFACE AT NUT PLATES BS1400-1420, RBL25, WL201. REPAIRED IAW EO B757-5310-40425-A, DATED 01-NOV-10.SDR IPXA10563489Floor Support · corrodedINSPECTION TYPE:C4, FLOORBEAM STABILIZER STRAP UPR SURFACE HAS CORROSION AT NUT PLATES BS 1220-1240, LBL 25, WL 201. REPAIRED IAW EO B757-5310-40425-A DATED 01NOV10.SDR IPXA10563480Seat Track · corrodedINSPECTION TYPE:C4, BS 1180 RBL 25 SEAT TRACK IS CORRODED. R & R SEAT TRACK IAW SRM 51-40-02, SRM 51-40-28 AND DWG 144N5204.SDR IPXA10563474Floor Skin · corrodedINSPECTION TYPE:C4 CORROSION ON FLOOR, BS 253.5, RBL 6 REPAIRED IAW ATS ER 10-05226 DATED 10-30-10.SDR IPXA10563460Seat Track · corrodedINSP TYPE:C4, BS 1180 RBL 25 SEAT TRACK IS CORRODED. R & R SEAT TRACK IAW SRM 51-40-02, SRM 51-40-05, SRM 51 -40-28 AND DWG 144N5204.SDR IPXA10563453Floor Skin · corrodedINSPECTION TYPE:C4, CORROSION ON FLOOR BS 274, RBL 13. REPAIRED IAW ER 10-05121.SDR IPXA10563452Floor Skin · corrodedINSPECTION TYPE:C4, CORROSION ON FLOOR AROUND BASE OF F/O'S AFT OTBD SEAT TRACK BS 254-271, RBL 26-35. REPAIRED IAW ER NR10-05121.
Back to Boeing 757-24APF