Boeing 757-24APF

Service difficulty reports · 16,067

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '75724APF'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA10560003Floorboard · delaminatedINSPECTION TYPE:C2, FLIGHT COMPT. STA 297 TO STA 330, RBL 10 TO RBL 65 FLIGHT COMPT. STA 2 HAS AREA DELAMINATED FABRICATED FLOOR BOARD PANEL IAW SRM 53-00-50-1A-1, B757-5320-9692-G, SRM 53-00-50-2R-1.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560002Floor Panel · damagedINSPECTION TYPE:C2, MAIN CARGO BAY FLOOR PANEL IS MISSING AN INSERT AT STA 1328, RBL 45. FABRICATED NEW FLOOR PANEL IAW SRM 53-00-50-1A-1, B757-510033281-BMay 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560001Floor Panel · damagedINSPECTION TYPE:C2, MAIN CARGO BAY FLOOR PANEL IS MISSING AN INSERT AT STA1253 LBL60 FABRICATED NEW FLOOR PANEL IAW SRM 53-00-50-1A-1, B757-5320-9692.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560000Floor Panel · damagedINSPECTION TYPE:C2, MCB FLOOR PANEL IS BROKEN AT INSERT, BS 620 TO BS 560 LBL 1 TO LBL 24 WL 208. FABRICATED NEW FLOOR PANEL IAW SRM 53-00-50-1A 1 B757-5320-9692G AND B757-5100-33281-B.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559978Floor Panel · puncturedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS PUNCTURE DAMAGE ON LWR SURFACE, BS 820 TO BS 880 LBL 45 TO LBL 26, WL 208 PANEL WAS REPLACED IAW EO B757-5320-9692-G.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559977Floor Panel · damagedINSPECTION TYPE:C2, MCB FLOOR PANEL DAMAGED ON LWR SURFACE, BS880 TO BS900 LBL 1 TO LBL24 WL208. PANEL WAS REPLACED IAW EO NR B757-5320-9692-G.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559976Floor Panel · puncturedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS PUNCTURE DAMAGE TO LWR SURFACE AND DELAMINATION BS620 TO BS560, LBL45 TO LBL 25, WL208 PANEL WAS REPLACED IAW EO NR B757-5320-9692-G.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559975Floor Panel · damagedINSPECTION TYPE:C2, MAIN CARGO BAY FLOOR PANEL BS1060-1100, LBL25-45 IS DAMAGED. PANEL WAS REPLACED IAW EO B757-5320-9692-G.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559974Floor Panel · damagedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS PUNCTURE DAMAGE. LBL45-60, BS440 REMOVED/FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559973Floorboard · damagedINSPECTION TYPE:C2, MAIN CARGO BAY FLOORBOARD PANEL BS 1100-1200, LBL 25-45 IS DAMAGED. REMOVAL FABRICATED FLOOR PANEL IAW B757-5320-9692-G.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559972Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL IS DAMAGED AT LOWER SURFACES BS 345-440 BL 0 TO LBL 25 WL 208. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A, FIG 101 AND UPS EO B757-5320-9692-G.May 19, 2010 · N422UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559966Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD DAMAGED IN NUMEROUS SPOTS, BOTTOM SIDE BS 620-720 LBL 45-65. REPLACED IAW EO B757-5320-9692-G, B757-5100-33281-B.May 19, 2010 · N437UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559963Floor Panel · puncturedINSP TYPE:C2, MCB FLOOR PANEL HAS PUNCTURE DAMAGE, LBL 25-45, BS 440 TO BS 480, WL 208. REPLACED FLOOR PANEL IAW EO NR B757-5320-9692 G.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559962Floor Panel · dentedINSPECTION TYPE:C2, MAIN CARGO BAY FLOORBOARD PANEL BS 1060-1100 LBL 45-62 IS DENTED. REPLACED FLOOR PANEL IAW EO B757-5320-9692G AND B757-5100-33281B.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559960Floor Panel · brokenINSPECTION TYPE:C2, MCB FLOOR PANEL IS BROKEN AT 2 INSERTS, BS 820 TO 880, LBL 45 TO LBL 60, WL 208. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G; EO B757-5100-33281.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559959Floor Panel · delaminatedINSP TYPE:C2, MAIN CARGO STA 340 TO STA 440 FLOORBOARD IS DELAMINATED NUMEROUS PLACES AT LOWER SURFACE. REPLACED FLOOR PANEL IAW EO NR B757-5320-9692 CH.May 19, 2010 · N428UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559928Window · bindingDURING PRE FLIGHT CAPT'S SIDEVIEW WINDOW WILL NOT UNLOCK AND BINDS. R & R CAPT NR 2 WINDOW OPERATIONAL IAW AMM 56-11-02-4. PERFORMED ADJUSTMENT IAW AMM 56-11-02-5. FOUND SATISFACTORY C/O LEAK TEST, NO LEAKS NOTED.May 19, 2010 · N431UP · Boeing 75724APF · Flight Compartment WindowsSDR IPXA0560650Shear Web · corrodedINSPECTION TYPE:C2, MAIN CARGO STA 340 TO 360. BL TO RBL 24.75 SHEAR WEB IS CORRODED NUMEROUS PLACES. REPAIRED SHEAR WEB CORROSION IAW SRM 53-00-51-1A-1, SRM 51-10-02-OG.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA0560649Shear Web · corrodedINSPECTION TYPE:C2, MAIN CARGO STA 340 TO STA 418 RBL 45.5 TO RBL 24.75 SHEAR WEB IS CORRODED. REPAIRED SHEAR WEB CORROSION IAW SRM 53-00-51-1A-1 ER 10-2932.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560531Seat Track · corrodedINSPECTION TYPE:C2, MAIN CARGO STA 340 TO STA 395 LBL45.5 SEAT TRACK OTBD FLANGE IS CORRODED. REPAIRED SEAT TRACK IAW ER 10-2949, SRM53-00-52 R8 SRM53-00-52-1A, FIG 101, DETAIL VIII.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560502Floorbeam · corrodedINSPECTION TYPE:C2, FLIGHT COMPT STA 310.5, BL 0 TO LBL 65 FLOORBEAMS ARE CORRODED AROUND FASTENERS HOLE. REPAIRED IAW ATS ER NR 10-2876 DATED 10JUN10 AND EO B757-5310-37937-A.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560470Floor Support · corrodedINSPECTION TYPE:C4 MULTIPLE AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT LBL 45 BS 1040 TO 1080. BLENDED MULTIPLE AREAS OF CORROSION ON FLOORBEAM, FOUND FLOORBEAM OUT OF LIMITS REMOVED FLOORBEAM, FABRICATED A NEW FLOORBEAM, LOCATED HOLES, DRILLED THRU HOLEMay 18, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560469Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT RBL 45 BS 1040 TO BS 1080. BLENDED MULTIPLE AREAS OF CORROSION ON FLOORBEAM, FOUND FLOORBEAM OUT OF LIMITS, REMOVED FLOORBEAM, FABRICATED NEW FLOORBEAM IAW DWG, LOCATED FASTENER HOLMay 18, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560396Shear Web · corrodedINSPECTION TYPE:C2, SHEAR WEB IS CORRODED AT LBL37 TO LBL43. REPAIRED BY BLENDING, INSTALLATION OF REPAIR DOUBLER IAW ER10-2941.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560282Sill · corrodedINSPECTION TYPE:C2 CREW ENTRY DOOR LOWER SILL IS CORRODED AT STA 297 TO 324, LBL 65 UPPER SURFACE. REMOVED CORROSION AND REMOVED AND REPLACED CREW ENTRY DOOR LOWER SILL AFT SECTION PER SRM 51-40-02-0G AND DWG 141N5140 REV "-"May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560149Panel · corrodedINSPECTION TYPE:C2, FLOOR TO SIDEWALL PANEL IS CORRODED, RBL 22, BS 645 TO 765. REPLACED PANEL IAW SRM 53-00-53-1A.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560141Support · corrodedINSPECTION TYPE:C2, FLOOR TO SIDEWALL SUPPORT PLATE IS CORRODED BS 765 TO 845, LBL 20. REMOVED, FABRICATED, AND INSTALLED IAW SRM 53-00-53-1A1.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560131Handle · gougedINSPECTION TYPE:C2, AFT CARGO DOOR EXTERNAL HANDLE GOUGED ON LWR AFT INTERNAL SURFACE. R & R DOOR HANDLE IAW CMM 52-34-14.May 18, 2010 · N428UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA10560083Shear Web · corrodedINSPECTION TYPE:C, MAIN CARGO STA. 440, RBL. 45.5 TO RBL 60. SHEAR WEB HAS AREA CORROSION. REPAIRED PER SRM 53-00-51-1A.May 18, 2010 · N428UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560838Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON SEAT TRACK AT LBL 60 BS 895-1080. R & R TRACK IAW SRM51-40-02.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560698Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT RBL 60, BS 1080 TO 1186 (REPAIR IS A MINOR/FAB FLOOR PANEL MAJOR) FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560657Floorbeam · corrodedINSPECTION TYPE:C4, TRANSVERSE FLOORBEAM UPPER CHORD FLANGE IS CORRODED AT BS 1100 LBL 25-45 WL 208. UPON INVESTIGATION FOUND 100 PERCENT MATERIAL LOSS OF BS 1100 FLOORBEAM, ACCOMPLISHED CONDUCTIVITY TEST OF BEAM, REMOVED FLOORBEAM, FABRICATED NEW REPLACEMENTMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA0560652Doubler · damagedINSPECTION TYPE:C4, MAIN CARGO DOOR, INNER SURFACE, FRAME AT BS 487 BETWEEN STR 14-17 HAS SEVERAL SCREW STARTS. REMOVED GOUGED AREA, UT MEASURED THICKNESS FORMED NEW DOUBLER FOUND GOUGED DOUBLER OUT OF LIMITS, ROUTED NEW DOUBLER FOR HEAT TREAT, DRILLED ALODINMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA0560644Shear Web · damagedINSPECTION TYPE:C1, WHILE WORKING CUSTOMER CARD 860401, FOUND FIG 8 HOLE AT BS 336, LBL 61, WL 208. REPAIRED IAW ATS ER NR 10-2816.May 17, 2010 · N437UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA0560620Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON INBD FLANGE OF FRAME AT B/S 680, BETWEEN STRINGERS 15R AND 16R. REPAIRED IAW EO NR 10-2866 DATED 6-16-10.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560595Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION ON FLOORBEAM UPPER CHORD BS 879, LBL 48-LBL 55. REPAIRED IAW ATS ER 10-2838.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560581Beam · corrodedINSPECTION TYPE:C4, CORROSION COMMON TO FASTENER HOLE IN STUB BEAM BS 901, RBL 49, WL 208. REPAIRED IAW ER NR 10-3017, DATED 16-JUN-2010.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10560580Beam · corrodedINSPECTION TYPE:C4, CORROSION ON B/S 900 STUB BEAM UPPER CHORD LBL49-55 REPAIRED IAW ATS ER NR 10-3017.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10560501Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORRISION ON LOGNITUDINAL FLOORBEAM AT LBL 25 - B.S. 895 TO B.S. 1070. REPLACED PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560500Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT LBL 45 BS 895 TO 1040. REPLACED PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560476Floor Support · corrodedINSPECTION TYPE:C4, FLOOR SUPPORT CORRODED. FOUND FLOOR SUPPORT OUT OF LIMITS, REPLACED IAW SRM 53-40-51-01I, SRM 51-40-02-0G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560475Floor Support · crackedINSPECTION TYPE:C4, FLOOR SUPPORT CRACKED BS 900, RBL 15, FLOOR SUPPORT OUT OF LIMITS, REPLACED IAW SRM 53-40-51-0I1, SRM 51-40-02-0G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560473Floor Support · corrodedINSPECTION TYPE:C4, AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT RBL 45 BS 895 TO BS 1040. R& R LONGITUDINAL FLOORBEAM UPPER CHORD IAW SRM 51-40-02-0G, SRM 51-40-05.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560472Floorbeam · corrodedINSPECTION TYPE:C4, UPPER SURFACE OF FLOORBEAM SUPPORT CORRODED COMMON TO 2 EA FASTENER HOLES BS 1054, RBL 53 TO RBL 57, WL 207. R & R FLOOR BOARD SUPPORT IAW SRM 51-40-02-0G, 51-21-04-7.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560471Floorbeam · corrodedINSPECTION TYPE:C4, FLOORBEAM FLANGE CORRODED AT BS 900, LBL 0-25, WL 208 BLENDED FLOORBEAM FLANGE AT BS 900, FOUND TO BE OUT OF LIMITS. REMOVED FLOORBEAM, FABRICATED NEW REPLACEMENT FLOORBEAM. DRILLED TRIMED ALODINED, PRIMED AND INSTALLED NEW FLOORBEAM IAW SMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560468Floorbeam · corrodedINSPECTION TYPE:C4, UPPER SURFACE OF FLOORBOARD SUPPORT CORRODED AT FASTENER HOLE B/S 1054, RBL34, WL 207. R & R FLOOR SUPPORT IAW SRM 51-40-02-0G, SRM 51-40-06-0G, AND DWG 144N5005.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560467Door Frame · damagedINSPECTION TYPE:C2, MAIN CARGO DOOR FRAME AT BS, 570.5" FROM LWR FRAME HAS A SCREW START. REPAIRED FRAME IAW ATS ER 10-2844.May 17, 2010 · N428UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10560466Stop Fitting · gougedINSPECTION TYPE:C2, MAIN CARGO AFT UPPER FRAME MOUNTED DOOR STOP FITTING GOUGED. REPLACED STOP FITTING IAW SRM 51-40-05-0G, 51-40-02.May 17, 2010 · N428UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10560465Stop Fitting · gougedINSPECTION TYPE:C2, MAIN CARGO DOOR FWD UPPER FRAME MOUNTED DOOR STOP FITTING IS GOUGED. REPLACED DOOR STOP FITTING IAW SRM 51-40-02, 51-40-05.May 17, 2010 · N428UP · Boeing 75724APF · Cargo/Baggage DoorsSDR IPXA10560460Door Frame · damagedINSPECTION TYPE:C2, MAIN CARGO DOOR FRAME AT BS 487, 5" UP FROM LWR FRAME HAS 3 EA SCREW STARTS. REPLACED FRAME DOUBLER IAW DWG 65-25327, SRM 51-40-02-0G AND SRM 51-40-05.May 17, 2010 · N428UP · Boeing 75724APF · Fuselage Main, Structure
Back to Boeing 757-24APF