SDR IPXA10560459Floorbeam · corrodedINSPECTION TYPE:C4, FLOOR SUPPORT FLANGE CORRODED AT BS 1016, LBL 25 TO LBL 45, WL 208. REMOVED FABRICATED AND REPLACED FLOOR SUPPORT TEE IAW SRM 51-40-05, SRM 51-10-02-0G STG R NR 8.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560458Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON INBD FLANGE OF FRAME AT B/S 640, BETWEEN STRINGERS 15R AND 16R. REPAIRED SCREW STRIKE ON INBD FLANGE OF FRAME IAW SRM 51-00-07-1A1, SRM 51-40-05-0G AND ER 10-2870.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560436Door Frame · damagedINSPECTION TYPE:C2, MAIN CARGO DOOR FRAME AT BS 570.5" UP FROM LWR FRAME HAS A SCREW START. REMOVED DAMAGE AND REPAIRED IAW ER NR 10-2844May 17, 2010 · N428UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10560427Floorbeam · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1420, LBL 45.5 TO LBL 60 FLOORBEAM UPPER SURFACE IS CORRODED AROUND FASTENER HOLE. REPAIR IAW ATS ER 10-2875.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560425Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT LBL 25 BS 1075 TO 1180. REPLACED SEAT TRACK IAW DWG 144N5024, SRM 51-40-02.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560405Floorbeam · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1540, LBL45.5 TO LBL 60 FLOORBEAM UPPER SURFACE IS CORRODED AROUND FASTENER HOLE. REPAIR IAW ATS ER 10-2852.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560391Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT LBL 45 BS 1075-1180. FOUND TO BE OUT OF LIMITS R & R WITH REPLACEMENT PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560389Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT RBL 45 BS 1075 TO 1180. FOUND TO BE OUT OF LIMITS R & R WITH REPLACEMENT PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560355Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK OF LBL 60 BS 1080- 1186. R & R SEAT TRACK IAW SRM 51-40-02.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560354Skin · chafedINSPECTION TYPE:C2, LT WING OTBD FWD FLAP LWR EDGE OF BULL NOSE IS CHAFED FROM INBD END TO 18 INCHES OTBD WHERE FLAP MAKES CONTACT WITH WING T/E PANEL. REPAIRED IAW ATS ER 10-2910.May 17, 2010 · N428UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA10560309Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION ON UPPER SURFACE OF FLOORBEAM COMMON TO 2 EA FASTNERS HOLES. BS 1200, RBL 48 TO RBL 52, WL 207. REPAIRED IAW ATS 10-2828.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560315Seat Track · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1661 TO STA 1681.8 LBL 45.5 SEAT TRACK HAS INBD FLANGE IS CORRODED AROUND FASTENERS HOLE. R & R SEAT TRACK IAW SRM 51-40-02-0G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560313Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKESON INBD FLANGE OF FRAME AT BS 780, BETWEEN STRINGERS 15L & 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560312Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKES ON INBD FLANGE OF FRAME AT BS 740, BETWEEN STRINGERS 15L AND 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560308Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKES ON INBD FLANGE OF FRAME AT BS 700, BETWEEN STRINGERS 15L AND 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560307Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKES ON INBD FLANGE OF FRAME AT BS 820, BETWEEN STRINGERS 15L AND 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560199Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO STA 1400, LBL 60 FLOOR PANEL HAS 1EA INSERTS MISSING. FLOOR PANEL ORIGINAL FOUND TO BE OUT OF LIMITS IAW SRM 53-00-50-IA 1 LOCATED MATERIAL, THEN CUT OUT SIZE, DRILLED AND INSTALLED INSERTS APPLIED SAFETY WALK NON-SKID FINISH.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560198Seat Track · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1180 TO STA 1200, LBL 45.5 SEAT TRACK HAS INBD AND OTBD FLANGE CORRODED GROUND FASTENER HOLES. BLENDED CORROSION FROM SEAT TRACK, FOUND IT TO BE OUT OF LIMITS, REMOVED DAMAGED SEAT TRACK, RECEIVED A NEW REPLACEMENT SEAT TRACMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560197Seat Track · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1180 TO STA 1200, LBL 24.75 SEAT TRACK HAS INBD AND OTBD FLANGE CORRODED GROUND FASTENERS HOLES. REMOVED CORROSSION FROM THE SEAT TRACK. FOUND IT OUT OF ALLOWABLE DAMAGE. R & R SEAT TRACK, DRILLED, PRIME AND PAINTED NEW REPMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560146Support Angle · crackedINSPECTION TYPE:C1, WING TO BODY FAIRING FORMER SUPPORT BRACKET IS CRACKED AT BS 1300, STR 24R, AT THE UPPER END OF THE FLANGE AGAINST THE SKIN REPLACED SUPPORT BRACKET IAW SRM 51-40-02-0G.May 17, 2010 · N437UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560137Wedge · delaminatedINSPECTION TYPE:C2, RT WING INBD MID FLAP PREVIOUS REPAIR ON UPPER T/E JUST OTBD OF AFT FLAP IS DELAMINATED. REPLACED T/E WEDGE IAW SRM51-40-02-0G AND 51-40-05-0G.May 17, 2010 · N428UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA10560129Floor Panel · dentedINSPECTION TYPE:C4 MCB FLOORBOARD PANEL DENTED BS 900 - 1016 LBL 45 - 62 FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560089Wedge · chafedINSPECTION TYPE:C4, RT WING NR 8 SLAT T/E WEDGE LOWER SURFACE HAS CHAFING JUST ABOVE OTBD MAIN TRACK (FOUND TO BE OUT OF LIMITS ON CARD NR 861178) REPAIRED RT WING NR 8 SLAT T/E WEDGE LOWER SURFACE IAW SRM 51-70-10-2R REPAIR 4.May 17, 2010 · N454UP · Boeing 75724APF · Leading Edge DevicesSDR IPXA10560067Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION ON UPPER SURFACE OF FLOORBEAM UPPER CHORD COMMON TO 4EA FASTENER HOLES BS 1100 RBL 48 TO RBL 54 WL 207. ENTIRE UPPER CHORD OF BS 1100 TRANVERSER FLOORBEAM WILL BE R & R ON CUST ID NR 861458.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560066Floorbeam · corrodedINSPECTION TYPE:C4, 6EA NUTPLATES CORRODED ON TRANSVERSE FLOORBEAM AT BS 1100 LBL 45-62. REMOVED 6EA NUTPLATES FROM FLOORBEAM, BLENDED CORROSION., NOTE. THE ENTIRE UPPER CHORD OF BS 1100 TRANVERSE FLOORBEAM WILL BE R & R ON CUST ID 861458.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560065Floorbeam · corrodedINSPECTION TYPE:C4, TRANSVERSE FLOORBEAM UPPER CHORD FLANGE IS CORRODED AT BS 1100 LBL 0-25, WL 208. ENTIRE UPPER CHORD OF BS 1100 TRANVERSER FLOORBEAM WILL BE R & R ON CUST. ID 861458.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560036Frame · damagedINSPECTION TYPE:C4, MAIN CARGO DOOR INNER SURFACE, FRAME AT BS 482 BETWEEN STR 14-17 HAS S SCREW START. REMOVED GOUGE, NDI FOUND NO CRACKS, FOUND TO BE WITHIN LIMITS IAW SRM 52-30-02 DETAIL IV ALODINED & PRIMED.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560010Floorboard · damagedINSPECTION TYPE:C4, MCB FLOORBOARD PANEL DAMAGED BS 1016-1055 LBL 45-62. FABRICATED REPLACEMENT FLOOR PANEL.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560009Floorboard · damagedINSPECTION TYPE:C4, DAMAGED FLOORBOARD AT 1100-1200 LBL 45-62. FABRICATED REPLACEMENT PANEL.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560008Floor Panel · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1681.8 TO STA 1661 FLOOR PANEL HAVE 4 EA INSERTS CORRODED BL 0 TO RBL 24.75. FABRICATED REPLACEMENT PANEL.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560007Floor Panel · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1420 TO STA 1540, LBL 45.5 TO LBL 60 FLOOR PANEL HAVE 8 EA INSERTS CORRODED FABRICATED REPLACEMENT PANEL.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560006Floorboard · dentedINSPECTION TYPE:C4, MCB FLOORBOARD PANEL DENTED BS 900-1016 LBL 45-62. FABRICATED REPLACEMENT PANEL.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560005Floorboard · damagedINSPECTION TYPE:C4 MCB FLOORBOARD PANEL DAMAGED BS 1055-1100 LBL 45-62. FABRICATED REPLACEMENT PANEL.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10559979Stringer Clip · corrodedINSPECTION TYPE:C4, CORROSION ON STRINGER CLIP B/S 620 STRINGER 5R. FABRICATED AND REPLACED STRINGER CLIP B/S 620, STRINGER 5R.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA10559969Skin · corrodedINSPECTION TYPE:C2, LT HORIZONTAL STAB SKIN EXTERIOR SURFACE HAS CORROSION APPROX 44 INCHES FROM CTR AND 9" FROM THE FWD EDGE. SKIN WAS TREATED IAW SRM 55-10-01-1A1.May 17, 2010 · N428UP · Boeing 75724APF · Horizontal Stabilizer, Plate/SkinSDR IPXA10560585Floorbeam · corrodedINSPECTION TYPE:C1, DUE TO RCD PROCESS, REPAIR REQUIRED AT BS 1200 FLOORBEAM, FWD FLANGE, RBL9, WL 208. REPAIRED IAW EO B757-5310-37909-A.May 16, 2010 · N437UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560503Stanchion · crackedINSPECTION TYPE:C4, BULK CARGO COMPARTMENT (LT) UPPER SIDEWALL SUPPORT STANCHION IS CRACKED AT UPPER FWD STA 1560. R & R WITH REPLACEMENT PART IAW DWG NR 453N1662.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560443Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON FRAME FLANGE AT BS 418 BETWEEN S-15R AND S-16R. REPAIRED IAW ATS ER 10-2850.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560440Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON FRAME FLANGE AT BS 365.25 BETWEEN S-15L AND S-16L. REPAIRED IAW ATS ER 10-2848.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560409Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON FRAME FLANGE AT BS 365.25 BETWEEN S-15R AND S-16R. BLENDED DAMAGE AND RE-FINISHED IAW ER 10-2846.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560343Skin · puncturedINSPECTION TYPE:C4, RT WING AILERON LWR SURFACE PUNCTURED JUST INBD OF 2ND FROM OTBD STATIC WICK. RT WING AILERON LWR SURFACE WAS REPLACED IAW SRM 51-70-04 AND SRM 51-60-01-OG.May 16, 2010 · N454UP · Boeing 75724APF · AileronsSDR IPXA10560267Support · corrodedINSPECTION TYPE:C4 BULK CARGO BAY FLOOR TO SIDEWALL HAS 4 CORRODED NUT PLATES BETWEEN SPLICE STATION 1410 TO 1530 LBL17 AND 19. SIDE WALL SUPPORT WAS REPLACED IAW SRM 51-40-02-GMay 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560265Cargo Track · gougedINSPECTION TYPE:C4 THE MAIN CARGO FLOOR TRACK HAS TWO GOUGES AT BS534 AND BS537 LBL62 WL208. FLOOR TRACK SECTION WAS REPLACED PER SRM 51-40-02-GMay 16, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560171Support · corrodedINSPECTION TYPE:C4, AFT CARGO BAY; FLOOR TO SIDEWALL SUPPORT HAS CORROSION AROUND CARGO TIE-DOWN FITTING, STA 1320 AND 1340, RBL 20. R & R FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G, SRM 53-60-53-0I, SRM 51-10-02.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560163Support · corrodedINSPECTION TYPE:C, BULK CARGO BAY; FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUTPLATE. R & R FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-OG, SRM 51-10-02.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560156Support · corrodedINSPECTION TYPE:C4, AFT CARGO BAY; FLOOR TO SIDE WALL SUPPORT HAS CORROSION AROUND CARGO TIE-DOWN FITTING, STATION 1300, RBL 20. REPLACED FLOOR TO SIDE WALL SUPPORT IAW SRM 51-40-02-0G AND EO B757-5310-32833-A.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560154Support · corrodedINSPECTION TYPE:C4, AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION AROUND NUMEROUS NUTPLATES STA 1340 AND 1380 RBL 19. FOUND TO BE OUT OF REPAIRABLE LIMITS IAW SRM 53-0053-1A1. ENTIRE SECTION OF FLOOR TO SIDEWALL SUPPORT WILL BE REPLACED ON CUSTOMER CAMay 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560119Floorboard · damagedINSPECTION TYPE:C4, CREW COMPARTMENT UPPER FLOORBOARD HAS MULTIPLE AREAS OF DAMAGE ON EDGE, A PUNCTURE, CORROSION ON INSERTS REPLACED IAW EO B757-5320-9692.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560064Floor Support · corrodedINSPECTION TYPE:C4, BULK CARGO BAY; FLOOR PANEL SUPPORT HAS 2 EA CORRODED NUTPLATES, STA 1469, AND 1470, LBL 16. 10. REMOVE NUTPLATES; REMOVED CORROSION FROM SUPPORT. FOUND TO BE OUT OF LIMITS, ORDERED AND RECEIVED NEW FLOOR SUPPORT LOCATED AND INSTALLED IAMay 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560035Intercostal · corrodedINSPECTION TYPE:C4, CREW ENTRY DOOR AREA INTERCOSTAL BELOW DRAIN PAN HAS CORROSION AT NUTPLATES. REMOVED CORROSION FROM PART - FOUND TO BE WITHIN REPAIRABLE LIMITS IAW SRM 53-00-51. ALODINED & PRIMED REWORK AREA IAW AMM 51-21-04-7.May 16, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous Structure
Back to Boeing 757-24APF