Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10559356Floorbeam · corrodedINSPECTION TYPE:C4 WHILE WORKING CUST CARD 849615 FOUND CORROSION ON FLOORBEAM LWR SURFACE AT NUT PLATE HOLE BS 1681 LBL 19-21, WL 208. REPAIR PER ATS ER 10-2302 UPS EO B757-5310-37439-A.SDR IPXA10559122Floor Panel · crackedINSPECTION TYPE:C4, WHILE WORKING CUST CARD NR 849024, FOUND MAIN CARGO BAY FLOOR PANEL CRACKED AND HAS EXPOSED HONEYCOMB ON UPPER SURFACE BS 560 TO BS 620, RBL 25 TO BL 0, WL 208.1. PANEL WAS REPLACED IAW EO B757-5320-9692-G.SDR IPXA10559509Frame · damagedINSPECTION TYPE:C4, BS 580 FRAME BETWEEN STR 22 AND 23 LT HAD HOLES IN THE RADIUS DUE TO A SIDEWALL LINER REPAIR. REPAIRED IAW ER NR 10-2333.SDR IPXA10559470Floor Panel · corrodedINSPECTION TYPE:C4, AFT CARGO NR 2 FLOOR PANEL IS CORRODED. FABRICATED NEW PANEL IAW SRM 53-60-53-01.SDR IPXA10559280Floorbeam · corrodedINSPECTION TYPE:C4, FOUND CORROSION ON FLOOR SUPPORT AT BS 1020 LBL 25 TO LBL 45. R & R SUPPORT IAW SRM 51-40-02SDR IPXA10559197Floor Panel · corrodedINSPECTION TYPE:C4 AFT CARGO BAY 3 FLOOR PANEL IS CORRODED. REPAIRED IAW SRM 53-60-53-01-1, AND SRM 51-40-05-06-A.SDR IPXA10559354Floorbeam · corrodedINSPECTION TYPE:C4 WHILE WORKING CUSTOMER CARD 849334, FOUND CORROSION ON UPPER AND LOWER SURFACES OF FWD FLANGE OF UPPER CHORD, 1680 FLOORBEAM AT RBL 12.75. REPAIRED PER ATS ER 10-2302 UPS EO B757-5310-37439-A.SDR IPXA10559544Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION ON BS 1360 FLOORBEAM LOWER FLANGE, RBL 26.5 TO 34, WL 201. REPAIRED IAW ER NR 10-2331 IPXA EO NR: B757-5310-37537-A.SDR IPXA10559508Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION ON BS 1100 FLOORBEAM FROM LBL 1 TO 22 WL 208 REPAIRED IAW ER NR10-2335.SDR IPXA10559490Seat Track · corrodedINSPECTION TYPE:C4 CORROSION ON SEAT TRACK O/B FLANGE, BS 592, LBL 25. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REPAIR IAW SRM 53-30-52-01 1, SRM 53-00-52-2R, SRM 51-10-02, SRM 53-00-52-2R5, EO NO. B757-5340-20264-B.SDR IPXA10559466Floorbeam · corrodedINSPECTION TYPE:C4, BS1200 FLOORBEAM HAS CORROSION ON UPPER SURFACE OF UPPER FLANGE AT SEVERAL NUTPLATE LOCATIONS, LBL24 TO RBL50 WL208.1. (MARKED) REMOVED CORROSION IAW SRM 51-10-02, FOUND AREAS TO BE OUT OF LIMITS, FABRICATED REPAIR AND INSTALLED IAW REPAISDR IPXA10559413Support · corrodedINSPECTION TYPE:C4, AFT CARGO LT FLOOR TO SIDEWALL SUPPORT UPPER SURFACE IS CORRODED. CORROSION REMOVAL BEYOND ALLOWABLE DAMAGE. R & R SIDE PANEL.SDR IPXA10559411Threshold · corrodedINSPECTION TYPE:C4, CARGO DOOR CUTOUT LOWER SILL NUT PLATE STRIP FOR ENTRY THRESHOLD CORRODED. CORROSION REMOVAL BEYOND ALLOWABLE DAMAGE. REMOVED, FABRICATED, INSTALLED REPLACEMENT STRIP.SDR IPXA10559403Support · corrodedINSPECTION TYPE:C4, AFT CARGO FLOOR TO SIDEWALL SUPPORT UPPER SURFACE IS CORRODED AT END AND AROUND TIE DOWN STANCHIONS, CORROSION REMOVAL BEYOND LIMITS. R & R PANEL.SDR IPXA10559367Seat Track · gougedINSPECTION TYPE:C4 SEAT TRACK GOUGED BS 1592, RBL 45, WL 208. REPAIRED PER ATS ER 10-2357 UPS EO B757-5310-37413-A.SDR IPXA10559355Floorbeam · corrodedINSPECTION TYPE:C4 WHILE WORKING REPAIR OF WEB FOUND CORROSION ON UPPER AND LWR SURFACE OF FLOOR PANEL ATTACH NUT PLATE HOLE THRU BS 1681 FLOORBEAM, LBL 31, WL 208. REPAIR PER ATS ER 10-2302 UPS EO B757-5310-37439-A.SDR IPXA10559336Seal Depressor · damagedINSPECTION TYPE:C4 MCB DOOR CUTOUT STRUCTURE, SEAL DEPRESSOR DAMAGED AT BS 480 BETWEEN STR 6L TO 9L (MARKED). REPLACED SEAL DEPRESSOR AT BS 480 STR 6L TO 9L SRM 51-10-02-0G SRM 51-40-02-0G, SRM 51-40-05, AND AMM51-21-10-7 AND AMM51-31-01-2.SDR IPXA10559276Floor Support · corrodedINSPECTION TYPE:C4 FOUND CORROSION ON FLOOR SUPPORT AT STA 1055 LBL 41. REMOVED AND REPLACED SUPPORT PER SRM 51-40-02.SDR IPXA10559275Floor Support · corrodedINSPECTION TYPE:C4 FOUND CORROSION ON FLOOR SUPPORT AT STA 1020 ON LBL 3-22. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-40-02.SDR IPXA10559274Floor Support · corrodedINSPECTION TYPE:C4 FOUND CORROSION ON FLOOR SUPPORT AT STA 1015 TO 1018 RBL 30. REMOVED AND REPLACED SUPPORT PER SRM 51-40-02.SDR IPXA10559273Floor Support · corrodedINSPECTION TYPE:C4 FOUND CORROSION ON FLOOR SUPPORT AT STA 1055 FROM BL 0 - LBL 44. REMOVED AND REPLACED SUPPORT PER SRM 51-40-02.SDR IPXA10559327Seat Track · corrodedINSPECTION TYPE:C4, FOUND CORROSION ON SEAT TRACK AT STA 1083, LBL 60. REMOVED CORROSION ON SEAT TRACK FOUND TO BE OUT OF LIMITS RECEIVED NEW SEAT TRACK PN 348451 DRILLED, DEBURRED INSTALLED IAW SRM 53-40-52-0I, SRM SRM 51-40-03 IAW SRM 51-10-02-0G STEP 14A. SDR IPXA10559318Strap · corrodedINSPECTION TYPE:C4, CORROSION ON UPPER SURFACE OF RBL 25 STABILIZER STRAP BS 1401 TO BS 1419, WL 201. BLENDED CORROSION. FOUND TO BE OUT OF LIMITS. FABRICATED, LOCATED, DRILLED, ALODINED AND PRIMED, PAINTED. REPLACED STABILIZER STRAP IAW SRM 51-20-01-0G, SRM SDR IPXA10559285Floor Panel · delaminatedINSPECTION TYPE:C4, FLOOR BOARD BROKEN AT BS440, LBL65. CORNER DELAMINATED REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1 AND UPS EONR B757-5320-9692-GSDR IPXA10559269Seat Track · corrodedINSPECTION TYPE:C4, CORROSION ON SEAT TRACK UPPER SURFACE AT BS 1201 TO 1204 RBL 24-26 WL 208. R & R SEAT TRACK IAW SRM 51-40-02.SDR IPXA10559268Seat Track · corrodedINSPECTION TYPE:C4 FOUND CORROSION ON SEAT TRACK AT STA 1198 ON LBL 26 R&R SEAT TRACK IAW SRM 51-40-02.-SDR IPXA10559227Floor Panel · damagedINSPECTION TYPE:C4, MCB, BSTA. 1600 TO 1680, RBL 45 TO RBL 65, FLOOR PANEL IS DAMAGED. REPLACED IAW SRM 53-00-50-1A1, EO B757-5320-9692-G.SDR IPXA10559211Floorbeam · corrodedINSP TYPE:C4 BS 1200 FLOORBEAM HAS CORROSION ON UPPER SURFACE OF UPPER FLANGE AT SEVERAL NUTPLATE LOCATIONS, LBL 24 TO RBL 50, WL 208.1 (MARKED) REMOVED CORROSION IAW SRM 51-10-02 FOUND AREA TO BE OUT OF LIMITS. FABRICATED REPAIR AND INSTALLED IAW REPAIR DSDR IPXA10559178Floor Panel · puncturedINSPECTION TYPE:C4, FLOOR PANEL HAS PUNCTURE IN UPPER SURFACE AT BS 504 LBL 9. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10559165Floor Panel · crackedINSPECTION TYPE:C4, MAIN CARGO FLOOR PANEL STA 900 TO 1020 RBL46 TO 61 WL208 FLOOR PANEL CRACKED AT STA 940. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10559543Frame · dentedINSPECTION TYPE:C4, BS 1360 FRAME IS DENTED AT STR 26 RT. REPAIRED IAW SRM 53-00-07-2R 5, FIG 201 AND SRM 53-60-07-0I 1, FIG. 1.SDR IPXA10559507Frame · dentedINSPECTION TYPE:C4, BS 1360 FRAME IS DENTED AT STR 26 RT. REPAIRED IAW SRM 53-00-07-2R 5, FIG. 201 AND SRM 53-60-07-0I 1, FIG. 1.SDR IPXA10559463Support · corrodedINSPECTION TYPE:C4, AFT CARGO BAY: FLOOR TO SIDEWALL SUPPORT HAS SEVERAL AREAS OF CORROSION AT BS 1310-1380, RBL 19-26. CORRODED AREAS FOUND TO BE OUT OF LIMITS, REPLACED FLOOR TO SIDEWALL SUPPORT IAW SRM 53-60-53-0I FIG 1, SRM 53-00-53-1A FIG 101 DETAIL V, SSDR IPXA10559460Intercostal · gougedINSPECTION TYPE:C4, AFT CARGO BAY INTERCOSTAL BETWEEN STR 25-26R 1360-1380 IS GOUGED 3" FROM FWD EDGE. REPLACED IAW SRM 53-00-04-1A, 51-40-02-0G, DWG 146N8536.SDR IPXA10559421Support · corrodedINSPECTION TYPE:C4, FLOOR TO SIDEWALL SUPPORT CORRODED, BS 1440 TO 1530, RBL 19-26. R & R IAW SRM 51-40-02-0G.SDR IPXA10559412Stringer · corrodedINSPECTION TYPE:C4, AFT CARGO BAY: FWD BULKHEAD TO FLOOR SUPPORT HAS SEVERAL AREAS OF CORROSION. CORROSION REMOVAL BEYOND ALLOWABLE LIMITS. REMOVED AND REPLACED STRINGER.SDR IPXA10559381Fitting · corrodedINSPECTION TYPE:C4 AFT CARGO BAY TIE DOWN BS 1372 LBL 22 HAS CORROSION. REPLACED PER SRM 53-60-53-1, 51-40-02-0G.SDR IPXA10559380Support · corrodedINSPECTION TYPE:C4 AFT CARGO BAY: FLOOR TO SIDEWALL SUPPORT HAS SEVERAL AREAS OF CORROSION AT BS 1455-1520 LBL 16-26. REPLACED PER SRM 51-40-02, 53-60-53-1.SDR IPXA10559379Floor Support · corrodedINSPECTION TYPE:C4 AFT CARGO BAY FLOOR SUPPORT AT LBL 16 HAS CORROSION AT BS 1470. REPLACED PER SRM 53-00-53-1A-1, 51-40-02.SDR IPXA10559371Floor Support · corrodedINSPECTION TYPE:C4 AFT CARGO BAY FLOOR SUPPORT HAS SEVERAL AREAS OF CORROSION BS 1446 - 1500 RBL 16. REPLACED PER SRM 51-40-02, 53-00-53-1A, 53-60-53-01A.SDR IPXA10559353Panel · corrodedINSPECTION TYPE:C4 FLOOR TO SIDEWALL SUPPORT CORRODED, BS 1440 TO 1530, RBL 19-26. REMOVED AND REPLACED PER SRM 51-40-02-0G.SDR IPXA10559352Panel · corrodedINSPECTION TYPE:C4 FLOOR TO SIDEWALL PANEL CORRODED AT BS 1200-1310, RBL 19-26. REMOVED AND REPLACED PER SRM 51-40-02-0G.SDR IPXA10559281Floorbeam · corrodedINSPECTION TYPE:C4 MAIN CARGO FLOOR AT STA 1052 RBL 9-RBL 21 WL 208 CORROSION AROUND NUT PLATES. R & R SUPPORT IAW SRM 51-40-02.SDR IPXA10559277Cargo Track · corrodedINSPECTION TYPE:C4, AFT CARGO BAY CARGO TIE DOWN BS 1440 RBL 22 HAS CORROSION. R & R FITTING IAW SRM 51-40-02.SDR IPXA10559272Floor Support · corrodedINSPECTION TYPE:C4 AFT CARGO BAY FLOOR SUPPORT HAS SEVERAL AREAS OF CORROSION AT BS 1446-1500 RBL 11. R & R SUPPORT IAW SRM 51-40-02SDR IPXA10559271Floor Support · corrodedINSPECTION TYPE:C4, AFT CARGO BAY FLOOR SUPPORT LBL 2 HAS CORROSION AT BS 1470. R & R SUPPORT IAW SRM 51-40-02SDR IPXA10559270Floor Support · corrodedINSPECTION TYPE:C4 AFT CARGO BAY FLOOR SUPPORT AT BS 1445-1500 LBL 8 HAS SEVERAL AREAS OF CORROSION. R & R SUPPORT IAW SRM 51-40-02.SDR IPXA10559267Angle · crackedINSPECTION TYPE:C4, BS 480-500 RBL 10-RBL 10 WL 208-WL 208 L-ANGLE OF FLOOR WEB IS CRACKED. R & R UPPER CHORD IAW SRM 51-40-02SDR IPXA10559226Cargo Track · corrodedINSPECTION TYPE:C4, AFT CARGO BAY: CARGO TIE DOWN AT BS 1500, RBL 22 HAS CORROSION. REPLACED IAW SRM 53-60-53-1, SRM 51-40-05, SRM 51-40-02.SDR IPXA10559225Cargo Track · corrodedINSPECTION TYPE:C4, AFT CARGO BAY: CARGO TIE DOWN AT BS 1320, RBL 22 HAS CORROSION. REPLACED IAW SRM 53-60-53-1, SRM 51-40-05, SRM 51-40-02.
Back to Boeing 757-24APF