Boeing 757-24APF
Service difficulty reports · 16,067
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '75724APF' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09557753Stanchion · crackedINSPECTION TYPE:C2 AFT CARGO COMPARTMENT LT SIDE WALL SUPPORT STRUCTURE, STANCHION ASSY BOX BEAM IS CRACKED AT BS 1420, LBL 50. REMOVED AND REPLACED STANCHION IAW ER NR 09-5065.SDR IPXA09557752Stanchion · crackedINSPECTION TYPE:C2 AFT CARGO COMPARTMENT LT SIDEWALL SUPPORT STRUCTURE, STANCHION ASSY BOX BEAM IS CRACKED AT BS 1400, LBL 50. REMOVED AND REPLACED CRACKED STANCHION IAW ER NR 09-5065.SDR IPXA09557751Bracket · bentINSPECTION TYPE:C2 AFT CARGO COMPARTMENT LEFT SIDEWALL SUPPORT STRUCTURE ANGLE BRACKET IS BENT AT BS 1400, LBL 50, WL 183, COMMON TO STANCHION ASSY BOX BEAM. REMOVED AND REPLACED SIDEWALL SUPPORT STRUCTURE ANGLE BRACKET AT BS 1400, LBL 50, WL 183.SDR IPXA09557750Bracket · bentINSPECTION TYPE:C2 AFT CARGO COMPARTMENT LEFT SIDEWALL SUPPORT STRUCTURE, ANGLE BRACKET IS BENT AT BS 1420, LBL 50, WL 183, COMMON TO STANCHION SUPPORT ASSY BOX BEAM. REMOVED AND REPLACED SIDEWALL SUPPORT STRUCTURE ANGLE BRACKET AT BS 1420 LBL 50 WL 183 IAW SSDR IPXA09557749Bracket · bentINSPECTION TYPE:C2 AFT CARGO COMPARTMENT LEFT SIDEWALL SUPPORT STRUCTURE ANGLE BRACKET IS BENT AT BS 1380, LBL 50, WL 183, COMMON TO STANCHION ASSY BOX BEAM. REMOVED AND REPLACED SIDEWALL SUPPORT STRUCTURE ANGLE BRACKET AT BS 1380, LBL 50 WL 183.SDR IPXA09557744Floorbeam · corrodedINSPECTION TYPE:C2 FLOORBEAM CORRODED OUT OF LIMITS BS 1200, LBL45 TO LBL 65. REPAIRED PER ATS EO NR 09-4920.SDR IPXA09557736Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED AT EDGES STA 1100-1200, LBL 24-LBL 48. DAMAGED AT FLOORBOARD WAS FOUND TO BE OUT LIMITS PER SRM 53-00-50-FIG 101. FABRICATED NEW FLOORBOARD ON MAE TR NR T9/806375 FROM MATL. P/N A402H PER IPXA EOB757-5320-9692GSDR IPXA09557735Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED AT EDGES STA 1100-1200, LBL 48-LBL 72. DAMAGED AT FLOORBOARD WAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-50 FIG 101. FABRICATED NEW FLOOR BOARD ON MAE TR NR T9/806376 FROM MATL. P/N A402H PER IPXA EO B757-5320-SDR IPXA09557734Floor Panel · damagedINSPECTION TYPE:C MAIN DECK FLOOR BOARD DAMAGED AT EDGES STA 1060 TO 1100, LBL48-LBL72. DAMAGED AT FLOOR BOARD WAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-50 FIG 101. FABRICATED NEW FLOOR BOARD ON MAE TR NR T9/806378 FROM MATL. P/N A402H PER IPXA EO B757-53SDR IPXA09557733Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED AT EDGES STA 1060 TO 1100, LBL24-LBL48. DAMAGE ON FLOORBOARD FOUND TO BE OUT OF LIMITS PER SRM 53-00 50 FIG 101. FABRICATED NEW FLOOR PANEL ON MAE TR NR T9/806379 MATL, P/N A402H PER IPXA EO NR B757-5320-969G.SDR IPXA09557707Support Bracket · bentINSPECTION TYPE:C2 AFT CARGO COMPARTMENT LT SIDE WALL SUPPORT STRUCTURE, ANGLE BRACKET IS BENT AT BS 1440, LBL 50, WL 183, COMMON TO STANCHION ASSY BOX BEAM. REMOVED AND REPLACED BRACKET PER SOPM 20-50-01SDR IPXA09557693Skin · chafedINSPECTION TYPE:C2 R/W INBD MAIN FLAP LWR SURFACE IS CHAFED AT T/E 10 INCH OTBDB OF INBD AFT FLAP OTBD END. FOUND TO BE OUT OF LIMITS ON CUST CARD NR 823314. REPAIRED IAW 757-200PF SRM 51-70-10-2R-4 FIG 202.SDR IPXA09557692Support Angle · crackedINSPECTION TYPE:C2 BS 1640 LOWER BULKHEAD SUPPORT ANGLE LBL 20 IS CRACKED JUST ABOVE FLOOR LEVEL. REMOVED AND REPLACED ANGLE PER SRM 51-40-02-0G.SDR IPXA09557691Angle · crackedINSPECTION TYPE:C2 1351640 LOWER BULKHEAD SUPPORT ANGLE RBL 20 IS CRACKED JUST ABOVE FLOOR LEVEL. REMOVED AND REPLACED ANGLE PER SRM 51-40-02-06.SDR IPXA09557676Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 800 RBL 22. REMOVED AND REPLACED FITTING PER SRM 51-40-02.SDR IPXA09557675Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 700 RBL 22. REMOVED AND REPLACED FITTING PER SRM 51-40-02.SDR IPXA09557670Support · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT UPPER SURFACE STA 765-845 RBL20-24. REPAIRED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT STA 765-845 RBL20-24 PER IPXA EO B757-5310-32833A.SDR IPXA09557661Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 760 RBL 22. REMOVED AND REPLACED FWD CARGO BAY TIE DOWN FITTING IAW SRM 51-40-02-0G.SDR IPXA09557659Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 820 RBL 22. REMOVED AND REPLACED PER SRM 51-40-02-0G.SDR IPXA09557656Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 840 RBL 22. REMOVED AND REPLACED MBA TIE DOWN FITTING AT BS 840 RBL 22 PER SRM 51-40-02-0G.SDR IPXA09557620Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 640 RBL 22. REMOVED AND REPLACED FITTING PER SRM 51-40-02-0G.SDR IPXA09557609Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 680 RBL 22. REMOVED AND REPLACED FITTING PER SRM 51-40-02-0G.SDR IPXA09557608Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON FWD CARGO BAY MBA TIE DOWN FITTING STA 660 RBL 22. REMOVED AND REPLACED FITTING PER SRM 51-40-02-0G.SDR IPXA09557594Attach Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON NET ATTACH FITTING, FWD CARGO BAY. CLEAN & TREAT PER SRM 51-10-02-0G.SDR IPXA09557593Attach Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON NET ATTACH FITTING, FWD CARGO BAY. CLEAN & TREAT PER SRM 51-10-02-0G.SDR IPXA09557592Attach Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON NET ATTACH FITTING FWD CARGO BAY. CLEAN & TREAT PER SRM 51-10-02-0G.SDR IPXA09557591Attach Fitting · corrodedINSPECTION TYPE:C2 CORROSION ON NET ATTACH FITTING FWD CARGO BAY. CLEAN & TREATED PER SRM 51-10-02-0G.SDR IPXA09557618Support Angle · crackedINSPECTION TYPE:C2 MLG WHEEL WELL RIGHT SIDE SUPPORT STRUCTURE AT BS 1060, RBL 60, THE SUPPORT ANGLE IS CRACKED. REMOVED AND REPLACED SUPPORT ANGLE IAW SRM 51-40-02-0G.SDR IPXA09557743Floorbeam · corrodedINSPECTION TYPE:C2 CORROSION ON FLOORBEAM BS 1100, LBL 55 TO RBL 55. REPAIRED PER ATS EO NR 09-4921.SDR IPXA09557742Floorbeam · corrodedINSPECTION TYPE:C2 CORROSION ON FLOORBEAM BS 1200, RBL55 TO LBL 55. REPAIRED PER ATS EO 09-4920.SDR IPXA09557702Skin · crackedINSPECTION TYPE:C LT WING FIXED LEADING EDGE SKIN AT FSS 436 HAS CRACK ACCOMPLISHED PERMANENT REPAIR OF FIXED LEADING EDGE SKIN IAW EO B757-5740-11855 APPENDIX B.SDR IPXA09557587Seat Track · corrodedINSPECTION TYPE:C2 SEAT TRACK HAS CORROSION BS 1080-1180 LBL 45. REMOVED AND REPLACED SEAT TRACK IAW SRM 53-00-52-1A1, SRM 51-10-02-0G, SRM 51-40-05-0G, SRM 51-40-08-0G, AND SRM 51-40-02-0G.SDR IPXA09557586Seat Track · corrodedINSPECTION TYPE:C2 SEAT TRACK HAS CORROSION BS 1077-1181 LBL 46. REMOVED AND REPLACED SEAT TRACK IAW SRM 53-00-52-1A1, SRM 51-10-02-0G, SRM 51-40-05-0G, SRM 51-40-08-0G, AND SRM51-40-02-0G.SDR IPXA09557566Structure · damagedINSPECTION TYPE:N/A FLOOR DAMAGED. FABRICATED NEW FLOOR IAW B757-5320-9692-G.SDR IPXA09557564Structure · damagedINSPECTION TYPE:N/A FLOOR DAMAGED. FABRICATED NEW FLOOR IAW B757-5320-9692-G.SDR IPXA09557563Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557562Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557561Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557560Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557559Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557558Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557557Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557556Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557555Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL P/N 141N5410-15 DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557619Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO BAY, LBL 30, FLOOR PANEL FWD END, PALLET STA 14 IS DAMAGED. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G AND MM 25-56-03-4.SDR IPXA09557585Skin · tornINSPECTION TYPE:C2 APU COMPARTMENT EXTERNAL RT DOOR SKIN AT BS 1918.9 IS TORN AT CENTRAL NUMBER (3) LATCH CUTOUT (MARKED). REPAIRED APU COMPARTMENT EXT RT DOOR SKIN IAW SRM 52-40-01-2R5 SRM 52-40-01-1A5.SDR IPXA09557584Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO BAY LBL 30 FLOOR PANEL FWD END PALLET STA 13 IS DAMAGED. REMOVED AND REPLACED FLOOR PANEL PALLET STATION 13 LBL 30 PER IPXA EO 757-5320-9692-G.SDR IPXA09557793Frame · dentedINSPECTION TYPE:C DENT ON FUSELAGE FRAME STA 1500 ALONG STR 25R BULK CARGO COMPT AREA. DENT AT FRAME STA 1500 FOUND TO BE OUT OF LIMITS PER SRM 53-00-07 1A1 FIG 101. TRIMMED OUT DAMAGE PER SRM 53-00-07-2R5. HFEC AT CUTOUT + HOLES PER NDT51-00-01/16 PT6. FASDR IPXA09557571Floor Panel · delaminatedINSPECTION TYPE:N/A PANEL 143N5457-3 DELAMINATED BEYOND REPAIR. FABRICATED FLOOR PANEL IAW B757-5320-9692-G.SDR IPXA09557570Floor Panel · damagedINSPECTION TYPE:N/A PANEL 143N5457-5 ON MCD DAMAGED. FABRICATED NEW FLOORBOARD PANEL PER EOB757-5320-9692-G.
Back to Boeing 757-24APF