SDR IPXA09557537Floor Panel · damagedINSP TYPE: C, DAMAGED TOP SKIN OF FLOOR PNL ON MAIN CARGO DECK STA. 878-900 LBL45-61. REMOVED DAMAGED FLOOR PANEL BET STA 878-9002) FAB. NEW FLOOR PANEL ON MAE TRAV NR T9/805673, PN UP143N5457-99 USING A402H, BATCH NR 1654769, PO NR MST27652 IAW UPS EO. NR B7SDR IPXA09557575Web · damagedINSPECTION TYPE:C1 LT WING DRY BAY CUTOUT WEB FOR PNL 532FZ HAS AREA OF DAMAGE ON AFT FACE WHERE PNL CONTACTS AT LWR OUTBOARD. REPAIRED PER SRM 51-70-07-0G & B757-5720-27753-A.SDR IPXA09557522Frame · dentedINSPECTION TYPE:C2 BS 1300 FRAME DENTED AT STR 26R. REPAIRED DENTED AREA IAW SRM 53-00-07-1A AND ER 09-4632.SDR IPXA09557532Attach Bracket · crackedINSPECTION TYPE:C1 WHILE WORKING CUSTOMER CARD 822126 FOUND WIRE CONDUIT ATTACH BRACKET C CRACKED IN HALF UNDER PANEL 435AL. REMOVED, FABRICATED AND INSTALLED REPLACEMENT BRACKET PER SRM 51-40-02.SDR IPXA09557539Floor Panel · corrodedINSPECTION TYPE:C1 AFT CARGO BAY NR 2 FLOOR PANEL HAS CORROSION. REMOVED & REPLACED PER SRM 53-00-53-1A1, 51-40-08-0G.SDR IPXA09557466Floorboard · damagedINSPECTION TYPE:N/A FLOORBOARD DAMAGED. REPAIRED FLOORBOARD.SDR IPXA09557576Skin · damagedINSPECTION TYPE:C1 LT HAND SIDE OF RUDDER HAS DAMAGE ON T/E (EXPOSED FIBERS) 22.5 INCHES BELOW LWR STATIC WICK BASE. REPAIRED PER SRM 51-70-05-0G.SDR IPXA09557549Floorboard · damagedINSPECTION TYPE:C1 EFN 43320001011 MCD FLOOR PANEL B/S 900-1060, LBL 0-25, TOOL MARKS ON LOWER SURFACE AND DAMAGE AROUND EDGES. REQUIRES REPAIR VALIDATION. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G AND AMM 25-55-04-4.SDR IPXA09557548Floorboard · damagedINSPECTION TYPE:C1 EFN 43300010/0 MCD FLOOR BOARD BS 1020-1060 LBL 25-45 TOOL MARKS AND PUNCTURES ON LOWER SURFACE AND EDGES DAMAGED. REQUIRES REPAIR VALIDATION. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G AND AMM 25-55SDR IPXA09557521Plate · crackedINSPECTION TYPE:C1 RT WING LOWER T/E INNER SURFACE WIGGLE PLATE IS CRACKED AT STA 335. REMOVED AND REPLACED PLATE PER SRM 51-40-02.SDR IPXA09557520Plate · crackedINSPECTION TYPE:C1 LT WING LWR T/E WIGGLE PLATE IS CRACKED AT WSTA 333. REMOVED AND REPLACED PLATE PER SRM 51-40-02.SDR IPXA09557470Floor Panel · damagedINSPECTION TYPE:C1 EFN 43320001015 MCD FLOOR PANEL BS 1020-1060 RBL 0-25 TOOL MARKS ON LOWER SURFACE EDGES AND CORNERS DAMAGED. REQUIRES REPAIR VALIDATION. FABRICATED REPLACEMENT FLOOR PANEL IN ACCORDANCE WITH EO B757-5320-9692-G.SDR IPXA09557577Skin Panel · dentedINSPECTION TYPE:C1 WHILE WORKING EO B757-5100-30760C FOUND DENT IN FUSELAGE SKIN BY EXISTING REPAIR AT BS 588 BELOW STR 19L. REPAIR IAW ER 09-4725.SDR IPXA09557547Wedge · delaminatedINSPECTION TYPE:C1 RT I/B MAIN FLAP T/E WEDGE IS DELAMINATED. REMOVED AND REPLACED T/E WEDGE.SDR IPXA09557546Skin Panel · crackedINSPECTION TYPE:C1 RT WING FIXED L/E SKIN CRACKED AT FSS 433.5. REPAIRED PER STANDARD EO B757-5740-11855-D.SDR IPXA09557507Bracket · crackedINSPECTION TYPE:C1 CRACKED ANGLE ON NR 2 NACELLE STRUT OUTBOARD STRUCTURE AT LOWER FWD ATTACH AREA OF PANEL 445AR. REMOVED AND REPLACED BRACKET PER SRM 51-40-02.SDR IPXA09557506Bracket · crackedINSPECTION TYPE:C1 NR 1 ENGINE AFT PYLON STRUCTURE RT CUTOUT FOR PANEL 435AR FWD LOWER ANGLE BRACKET IS CRACKED. REMOVED AND REPLACED BRACKET PER SRM 51-40-02.SDR IPXA09557449Transmitter · faultyINSPECTION TYPE:N/A WHEN FLAPS 15 DEG SELECTED, RECEIVED EICAS MSG "TRAILING EDGE FLAP DISAGREE". FLAP INDICATOR NEEDLES STOPPED PRIOR TO THE FLAP 15 DEG WHITE BAND. EMERGENCY DECLARED. NO SHORT IN RUN FROM NR 1 FSEA PLUG B-E/6 TO K10095 RELAY. REMOVED ANDSDR IPXA09557552Structure · corrodedINSPECTION TYPE:C1 TAIL COMPARTMENT, RT BS 1792, APU INLET DOOR FWD MOUNT STRUCTURE IS CORRODED AT NUT PLATES. REPAIR PER ER 09-4726.SDR IPXA09557538Floor Panel · crackedINSPECTION TYPE:C1 EFN 4330001008 MCD FLOOR PANEL BS 900-1020 LBL 25-45 NUMEROUS CRACKS & TOOL MARKS ON LOWER SURFACE AND EDGE DAMAGED REQUIRES REPAIR VALIDATION. REMOVED AND REPLACED EO B757-5320-9692.SDR IPXA09557535Floor Panel · damagedINSPECTION TYPE:C1 EFN 43320001019 MCD FLOOR PANEL BS 1060-1100 LBL 25-45 FWD I/B CORNER DAMAGED REQUIRES REPAIR VALIDATION. REMOVED, FABRICATED AND INSTALLED REPLACEMENT PANEL PER EO B757-5320-9692-G.SDR IPXA09557469Floor Panel · damagedINSPECTION TYPE:C-1 EFN 43320001012 MCD FLOOR PANEL BS 900-1060 RBL 0-25 TOOL MARKS ON LOWER SURFACE EDGES AND CORNERS DAMAGED. REQUIRES REPAIR VALIDATION. FABRICATED NEW FLOOR PANEL PER EO B757-5320-9692.SDR IPXA09557468Floor Panel · damagedINSPECTION TYPE:C-1 EFN 43320001017 MCD FLOOR PANEL BS 1100-1200 LBL 0-25, 2 EA INSETS MISSING OR DAMAGED AT FWD O/B CORNER. REQUIRES REPAIR VALIDATION. FABRICATED NEW FLOOR PANEL PER ER B757-5320-96-G.SDR IPXA09557452Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO BAY FLOOR PANEL BS 1000-1040 LBL 45-60 WL 208 HAS 1 DAMAGED INSERT. REPLACED INSERT PER SRM ADDENDUM B757-5320-9692-G.SDR IPXA09557451Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO BAY FLOOR PANEL BS 900-1000 LBL 45-60 WL 208 HAS 1 DAMAGED INSERT. REPLACED INSERT PER SRM ADDENDUM B757-5320-9692-G.SDR IPXA09557450Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO BAY FLOOR PANEL BS 900-1000 LBL 45-60 WL 208 HAS 7 DAMAGED INSERTS. REPLACED INSERTS PER SRM ADDENDUM B757-5320-9692-G.SDR IPXA09557427Acm · seizedINSPECTION TYPE:N/A FLT DECK FAILS TO MAINTAIN DESIRED TEMP IN AUTO. DURING CLIMB AT 8K LT EEC INOP LIGHT & LT LIMITER LIGHT WITH ASSOCIATED EICAS MESG. CAPTS SLIDING WINDOW W/N OPEN. EICAS MSG R PACK TEMP AND RT PACK INOP LIGHT DISPLAYED. AT 13K MSL SMELLSDR IPXA09557455Panel · corrodedINSPECTION TYPE:C2 SIDE PANEL CORRODED, BS 520, LBL 19, WL 156. REMOVED, FABRICATED, AND INSTALLED PER SRM 51-40-02.SDR IPXA09557454Floor Panel · corrodedINSPECTION TYPE:C2 CORROSION ON NR 3 FLOOR PANEL IN FWD CARGO BAY. REMOVED, FABRICATED, AND INSTALLED PER SRM 53-00-53.SDR IPXA09557445Attach Fitting · corrodedINSPECTION TYPE:C2 FWD CARGO BAY DOOR CUTOUT LOWER THRESHOLD ATTACH FITTING STATION 607 LOWER AFT FASTENER MOUNT HOLE IS CORRODED. REMOVED AND REPLACED PER SRM 51-40-02-0G.SDR IPXA09557444Attach Fitting · corrodedINSPECTION TYPE:C2 FWD CARGO BAY DOOR CUTOUT: LOWER THRESHOLD ATTACH FITTING STATION 574 LOWER FWD FASTENER MOUNT HOLE IS CORRODED. REMOVED AND REPLACED FITTING.SDR IPXA09557442Frame · dentedINSPECTION TYPE:C2 BS 1240 FRAME DENTED AT STR 25L. REPAIRED REV ATS ER 09-4631.SDR IPXA09557433Flap · damagedINSPECTION TYPE:C2 RT OUTBOARD AFT FLAP TRAILING EDGE TIP HAS FIBER DAMAGE AT OUTBOARD FLAP TRACK FAIRING. REMOVED DAMAGE & REPAIRED PER SRM 57-53-01-0I-1 FIG 2 SHEETS 1-10&13 & DETAIL VII ITEM.SDR IPXA09557428Floor Panel · corrodedINSPECTION TYPE:C2 FWD CARGO NR 4 FLOOR PNL HAS AREAS OF CORROSION ON UPPER SURFACE AT MBA SYS CONTACT POINTS. FABRICATED REPLACEMENT FCB NR 4 FLOOR PANEL IAW SRM 51-40-05-0G.SDR IPXA09557463Floor Support · corrodedINSPECTION TYPE:C-2 MAIN CARGO COMPARTMENT BS 1020, BL 0 - RBL 25, FLOOR SUPPORT IS CORRODED AT FASTENER HOLES. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR SUPPORT IAW DWG 144N5005 AND SRM 51-40-02-0G.SDR IPXA09557435Bracket · crackedINSPECTION TYPE:C2 FWD CARGO BAY CEILING PANEL TO FLOORBEAM ATTACH BRACKET IS CRACKED BS 520 BL 0, WL 200. REMOVED, FABRICATED AND INSTALLED BRACKET PER SRM 51-30-01-0G AND DWG 453N1858.SDR IPXA09557531Floorbeam · corrodedINSPECTION TYPE:C-2 MAIN CABIN, 1100 FLOORBEAM UPPER T-CHORD, LBL 65 TO RBL 65 IS CORRODED IN NUMEROUS AREAS. REPAIR PER ATS ER 09-4596.SDR IPXA09557530Floorbeam · corrodedINSPECTION TYPE:C-2 MAIN CABIN, 1200 FLOORBEAM UPPER T-CHORD, LBL 10 IS CORRODED. REPAIRED PER ATS ER 09-4583.SDR IPXA09557529Floorbeam · corrodedINSPECTION TYPE:C-2 MAIN CABIN, 1200 FLOORBEAM UPPER CHORD, RBL 45 - RBL 65 HAS CORROSION ON UPPER AND LOWER SURFACE. REPAIRED PER ATS ER 09-4538.SDR IPXA09557526Skin Panel · crackedINSPECTION TYPE:C2 RT WING FSS 440 FIXED LOADING EDGE 6 INCHES CRACK IN FIBER. ACCOMPLISHED WORK EO B757 5740-11855-D APPENDIX B.SDR IPXA09557519Wedge · debondedINSPECTION TYPE:C2 LT WING L/E NR 4 SLAT HAS DISBOND ON UPPER SURFACE T/E WEDGE 50.5 FROM O/B END 7 INCHES FROM T/E. REMOVED AND REPLACED NR 4 SLAT ASSY IAW MM 27-81-02-4.SDR IPXA09557509Seat Track · corrodedINSPECTION TYPE:C2 MAIN CABIN RBL 45, BS 1180 - BS 1200 SEAT TRACK FLANGE HAS CORROSION AT FASTENER HOLES. REMOVED CORROSION, VERIFIED NO CRACKS EXIST, FILLED DIVIT, APPLIED CPC.SDR IPXA09557508Seat Track · corrodedINSPECTION TYPE:C2 MAIN CABIN RBL 25, BS 1180 - BS 1200, SEAT TRACK FLANGE HAS CORROSION AT FASTEN HOLES. REPAIRED SEAT TRACK FLANGE IAW ER 09-4627.SDR IPXA09557467Floor Panel · corrodedINSPECTION TYPE:C2 AFT/BULK CARGO COMPARTMENT NR 2 FLOOR PANEL HAS EXCESSIVE CORROSION UNDERNEATH THE MBA SYSTEM. FLOOR PANEL OUT OF LIMITS, FABRICATED NEW FLOOR PANEL PER SRM 53-00-53-1A, SRM 51-40-05-06.SDR IPXA09557462Floor Support · corrodedINSPECTION TYPE:C-2 MAIN CABIN, BL 0 - LBL 25, BS 1050, FLOOR SUPPORT HAS CORROSION AT FASTENER HOLES. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR SUPPORT IAW DWG 144N5005 AND SRM 51-40-02-0G.SDR IPXA09557461Floor Panel · corrodedINSPECTION TYPE:C2 AFT CARGO BAY NR 4 FLOOR PANEL IS CORRODED. REMOVED, FABRICATED, AND INSTALLED FLOOR PANEL PER SRM 51-20-05 AND SRM 51-40-08.SDR IPXA09557456Beam · corrodedINSPECTION TYPE:C2 LONGITUDINAL BEAM CORRODED, BS 1040 TO 1076, LBL 24, WL 208. REMOVED, FABRICATED, AND INSTALLED PER SRM 51-40-02, AND DWG 144N8017.SDR IPXA09557434Skin Panel · crackedINSPECTION TYPE:C2 LEFT O/B MAIN FLAP LOWER SURFACE HAS POSSIBLE CRACK 11 INCHES FROM AFT AND 2 INCHES FROM O/B END. REPAIRED MAIN FLAP PER 757-200 PR SRM 57-53-01-2R-4.SDR IPXA09557408Floor Panel · corrodedINSPECTION TYPE:C2 AFT CARGO BAY NR 1 FLOOR PANEL IS EXCESSIVELY CORRODED UNDERNEATH THE MBA SYSTEM. FABRICATION NEW FLOOR PANEL AND INSTALLED IAW SRM 53-00-53-1A AND MM25-50-04-4.SDR IPXA09557400Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOOR PANEL AT BS 900-1020 RBL 45-65 HAS A PREVIOUS INSTALLED REPAIR AT BS 974, RBL 54. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692 APPENDIX B.
Back to Boeing 757-24APF