Boeing 757-251
Service difficulty reports · 4,707
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757251' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757251' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13058445640Attach Fitting · corrodedFWD CARGO DOOR CUT OUT LOWER SILL ATTACH ANGLE CORRODED RBL 22 BS 600 . REMOVED AND REPLACED ATTACH FITTING IAW DRAWING 143N8560, 143N8522 AND SRM 51-40-02 .SDR DALA13058395640Bracket · corrodedRIGHT PASSENGER DOOR LOWER SILL UPPER SURFACE, THRESHOLD PLATE MOUNTING BRACKETS CORRODED. REMOVED CORROSION , FWD BRACKET WITHIN LIMITS, TREATED, PRIMED AND TOP COATED IAW SRM 51-20-01. AFT BRACKET FOUND TO BE OUT OF LIMITS. FABRICATED AND REPLACED AFT SDR DALA13061735639Doubler · corrodedFOUND DOUBLER CORRODED AND FOUND OUT OF LIMITS IAW SRM 53-00-01, PAGE 104, FIG 101, DETAIL II. FABRICATED , TREATED, PRIMED, AND APPLIED TOP COAT ON NEW REPLACEMENT DOUBLER, IAW SRM 51-30-01, PAGE 7,8, FIG. 3, PAG 13, SRM 51-40-05, FIG. 3. PAG 4, SRM 51-20SDR DALA13058405640Seat Track · corrodedPASSENGER CABIN FWD WET AREA SEAT TRACK CORRODED BS 377 LBL 24. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-52. REMOVED AND REPLACED SEAT TRACK IAW SRM 51-40-05 AND 51-40-02.SDR DALA13058375640Floor Support · corrodedPASSENGER CABIN FWD WET AREA FLOOR SUPPORT CORRODED, BS 334-342 LBL 21. REMOVED CORROSION IAW SRM 51-10-02 AND DRILL NEW FLOOR SUPPORT IAW DWG 141N1570 AND SRM 51-40-05 PG. 1.SDR DALA13058425640Shear Web · corrodedPASSENGER CABIN SHEAR WEB. CLEANED CORROSION, FOUND OUT OF LIMITS AND REPAIRED IAW SRM 53-60-51.SDR DALA13058415640Bracket · corrodedL4 DOOR LOWER SILL UPPER SURFACE, THRESHOLD PLATE MOUNTING BRACKET CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15. REMOVED BRACKET IAW SRM 757 51-40-02 PG 1-7. NEW BRACKET FABRICATED IAW DWG 146N8016.SDR DALA13056525655Battery Pack · inoperativeFOUND EMERGENCY LIGHTS OUT AT SEATS ROW 24-28 AND OVERHEAD ROW 29-37 FOUND BATTERY BAD ABOVE 31ABC. REPLACED WITH BATTERY PACK.SDR DALA13056555646Skin · puncturedFOUND SKIN PUNCTURED BS 1862 S-25L. DAMAGE OUT OF LIMITS IAW SRM 53-80-01 AND 53-00-01. ACCOMPLISHED ER/A 520161-14 AND NO OTHER DAMAGE FOUND.SDR DALA13058295640Floorbeam · corrodedPASSENGER CABIN AFT WET AREA UPPER SURFACE OF SHEAR WEB ABOVE BS 1681.8 FLOORBEAM IS CORRODED FROM APPROX LBL-2 TO LBL-31. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-60-51. REMOVED DAMAGE AND REPAIRED IAW SRM 53-60-51.SDR DALA13056435646Engine · leakingCREW ACCOMPLISHED AN AIR TURN BACK TO NRT DUE TO SMOKE, HAZE AND ODOR IN CABIN. MAINTENANCE FOUND 2.5 BLEED PORT WET WITH OIL SUSPECT BEARING SEAL LEAKAGE. REPLACED NR 1 ENGINE.SDR DALA13058385640Floor Support · corrodedPASSENGER CABIN FWD WET AREA FLOOR SUPPORT CORRODED BS 365, BL 0. REMOVED CORROSION IAW SRM 53-00-04. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02.SDR DALA13058285639Floor Panel · corrodedAFT CABIN DECK PLATE CORRODED IN MULTIPLE AREAS BS 1681-1720 BL 0- RBL 52. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-51. DECK PLATE REPLACED .SDR DALA13056325640Floor Support · corrodedPASSENGER CABIN LT AFT WET AREA FLOOR SUPPORT, INBD OF CUSP WEB, AT L4 DOOR SCUPPER DRAIN, BETWEEN BS 1640 AND 1661, LBL 58-56 CORODED. R & R FLOOR SUPPORT IAW SRM 51-40-02, DWG NR 146N8722 AND DWG 146N5230.SDR DALA13056315640Floor Support · corrodedPASSENGER CABIN LT AFT WET AREA FLOOR SUPPORT, INBD OF CUSP WEB, AT L4 DOOR SCUPPER DRAIN TROUGH, BETWEEN BS 1661 - 1681, LBL-54-56, CORRODED ON LOWER AND UPPER SURFACE. R & R FLOOR SUPPORT IAW DWG 146N5230.SDR DALA13061715639Floorbeam · corrodedFWD CABIN FLOORBEAM HAS COROSION AT BS 324 RBL 61. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-08, DETAIL IX, FIG 101, ALLOWABLE DAMAGE 1. REPAIRED FLOORBEAM IAW SRM 53-10-08, REPAIR 1, PG 201-204.SDR DALA13058275639Floor Panel · corrodedAFT CABIN LT GALLEY DECK PANEL HAS MULTIPLE CORROSION FROM BS 1681-1720, BL 0- LBL 52. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, PG 102-104. REMOVED, FABRICATED. LOCATED AND DRILLED AFT CABIN DECK PLATE IAW DWG 146N5300 AND SRM 51-40-05.SDR DALA13058265639Floor Panel · corrodedAFT CABIN LT GALLEY DECK PANEL HAS MULTIPLE AREAS OF CORROSION FROM BS 1768--1720 BL 0- LBL 52. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. LOCATED AND DRILLED AFT CABIN DECK PLATE FROM BS 1681 TO 1720.SDR DALA13063805639Fitting · corrodedCORROSION ON WRAP AROUND FITTING AT FWD CARGO DOOR CUTOUT, BS 600, AROUND LOWER BOLT. REMOVED TWO ANGLES AT FWD CARGO DOOR CUTOUT AND REMOVED CORROSION LOWER BOLT. FOUND TO BE WITHIN LIMITS IAW SRM 51-40-02.SDR DALA13058255639Seat Track · gougedMAIN CABIN SEAT TRACK BS 1280, LBL 45.5 HAS DEEP GOUGES ON CROWN. REPAIRED IAW SRM 53-00-52.SDR DALA13053415650Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE. R & R BATTERY PACK AND CHARGER IAW AMM 33-51-07. OPS CHECKED NORMAL. ACFT OK FOR SERVICE.SDR DALA13060225640Angle · corrodedAFT CARGO, BS 1508-1520 ZEE ANGLE CORRODED AROUND FASTNER HOLES. ZEE ANGLE REPLACED. CORROSION CLEANED OUT OF LIMITS IAW SRM 53-00-53.SDR DALA13060215640Angle · corrodedAFT CARGO, BS 1480-1500 ZEE ANGLE CORRODED AROUND FASTNER HOLES. ZEE ANGLE REPLACED. CORROSION CLEANED OUT OF LIMITS IAW SRM 53-00-53.SDR DALA13053005531Fuse · blownEMERGENCY LIGHT IN FIRST CLASS CABIN INOPERATIVE. REPLACED BLOWN FUSE IN POWER PACK IAW AMM 33-51-07, OPS CHECKED OK.SDR DALA13050605531Light · looseSEAT 22D, EMERGENCY LIGHT LOOSE. REPAIRED EMERGENCY LIGHT.SDR DALA13050595531Light · damagedEMERGENCY LIGHT DAMAGED. REPAIRED EMERGENCY LIGHT.SDR DALA13044905639Light · inoperativeSEAT 23C EMERGENCY PATH LIGHT INOPERATIVE. REPACED LAMP & REPLACED LIGHT ASSY. OPS CHECKED GOOD.SDR DALA13044445637Unknown · odorAPPROXIMATE 25 MINUTES AFTER TAKEOFF, CLIMBING THRU 35,000' SLIGHT BURNING, ELECTRICAL ODOR THROUGHOUT ENTER ACFT. COMPLETELY DISSIPATED AFTER 5 MINUTES, NO FURTHER ODOR FOR REMAINDER OF FLIGHT. CAPTAIN`S FMC CDU WAS VERY HOT, COULD NOT TOUCH. VISUALLY INSDR DALA13044435522Skin · scratchedFOUND A 7 INCH LONG SCRATCH IN FUSELAGE APPOXIMATELY 12 INCHES AFT OF L3 COCKPIT WINDOW LOWER AFT CORNER AND 10 INCHES BELOW LAP SEAM. BLENDED AND ACCOMPLISHED EDDY CURRENT. WITHIN LIMITS AND OK FOR SERVICE IAW SRM 53-00-01. HFEC 51-00-17 NO CRACKS.SDR DALA13044425519Panel · delaminatedLT WING FIXED PANEL OTBD OF INBD T/E FLAP OTBD OF OTBD CARRIAGE JUST FWD OF FLAP LWR SURFACE OF WING DELAMINATED. REPLACED T/E PANEL ASSY 113N1972-9 IAW DWG 113N1620 ON N/R CARD 003.SDR DALA13043655650Charger · inoperativeEMERGENCY LIGHTS POWERED BY BATTERY PACK INOPERATIVE. R & R BATTERY CHARGER AND BATTERY PACK. EMERGENCY LIGHTS OPS CHECKED NORMAL IAW AMM 33-51.SDR DALA13043615531Skin · dentedFOUND FOUR DENTS, LT SIDE FWD OF L4 DOOR BS 1610 18L DENTS OUT OF LIMITS IAW SRM 53-00-01, FIG 101. CUT OUT DAMAGE IAW SRM 53-00-01, FIG 201. PERFORMED HFEC AND BHEC OF REPAIR CUTOUT AND EXISTING FASTENER HOLES IAW SRM 53-00-01, FIG 201, REPAIR 2, NO CRACKS SDR DALA13042765532Controller · failedDUE TO R1 WINDOW SHATTERED. REPLACED WINDOW AND WINDOW HEAT CONTROLLER. OPS CHECKED OK.SDR DALA13042825641Battery Pack · inoperativeEMERGENCY LIGHTS FOR AISLE SEATS 24 THRU 28 INOPERATIVE. R & R BATTERY PACK, OPS CHECKED GOOD IAW MM 33-51.SDR DALA13042385638Fuse · failedEMERGENCY EXIT SIGN AT SEAT 21ABC AND SEAT 22DEF INOPERATIVE. FOUND FUSE OPEN OF POWER SUPPLY "M10567". REPLACED FUSE AND OPS CHECKED OK IAW AMM 33-51. ACFT OK FOR SVC.SDR DALA13042395530Connector · looseSEAT 4A/B EMERGENCY LIGHT INOPERATIVE AT CURVED EDGE OF STOWAGE BIN CK LIGHT ASSY CHECKED GOOD. RESEATED CONNECTOR ON M731 PWR SUPPLY-NOW OPS CK NML.SDR DALA13041805639Circuit Breaker · failedP-11 CIRCUIT BREAKER C36 BROKEN. "EMERGENCY CHARGER ALT". REPLACED CIRCUIT BREAKER C36 IAW WDM 33-51-11. CIRCUIT BREAKER IS INOPERATIVE IAW WDM.SDR DALA13041475654Power Supply · inoperativeEXIT LIGHTS INOPERATIVE. R & R POWER SUPPLY & BATTERY IAW MM 33-51. OPS CHECKED GOOD.SDR DALA13042835525Skin · damagedLIGHTNING STRIKE DAMAGE AT FS 1518, STRINGER 1. REMOVED DAMAGE IAW RI 518136-14, IN CONJUNCTION WITH SRM 53-00-01, REPAIR 2-431063. DAMAGE REMOVED IS .75" X 1.2". HFEC INSPECTION CUT-OUT AND BHEC HOLES IAW SRM 53-00-01, FIG 201- NO CRACKS. FABRICATED REPAISDR DALA13040045525Oven · smokeAT CRUISE THE F/A REPORTED SMOKE FROM F/C OVENS. THEY TURNED OVENS OFF AND SMOKE STOP IAW QRH. MX AND DISPATCH ADVISED TO CONTINUE FLIGHT. ONCE ON GROUND MX RAN OVENS FOR 20 MINUTES AND NO SMOKE OF FUMES.SDR DALA13040015523Stringer · corrodedCORROSION ON STRINGER 29R AT BS 1420 REMOVED STRINGER 29R BETWEEN BS 1405-1430 STARTED DRILLING NEW STRINGER SECTION IAW SRM 53-00-03, REPAIR 1, FIG 201. C/W HFEC INSPECTION NDT PART 6-51-00-16. NO ITEMS COMPLETED FABRICATION OF REPAIR PARTS IAW SRM 53-00-03SDR DALA13040005530Power Supply · inoperativeFWD EMERGENCY EXIT SIGN INOPERATIVE. REPLACED POWER SUPPY M730 IAW AMM 33-51.SDR DALA13040025523Skin · damagedSEVERAL RIVETS DAMAGED ON BELLY BELOW C2 CARGO DOOR. BS 1420, COMPLIED WITH ERA ORIG 517912-14.SDR DALA13038295530Charger · inoperativeEMERGENCY LIGHT IN OVERHEAD BIN ROW 4 A/B INOPERATIVE. R & R BATTERY CHARGER M731 IAW AMM 33-51 OPS CHECKED GOOD.SDR DALA13037605523Lens · damagedEMERGENCY LIGHT LENS DAMAGED 29D. INSTALLED A NEW LENS.SDR DALA13036875521Wire · looseDIVERTED, SMOKE IN THE CABIN. IN GALLEY 1A FOUND WIRE 18 ON PLUG J003 NOT LOCKED IN CONNECTOR. REPINNED WIRE WITH NEW SOCKET. REPLACED OVEN BANK AND LT OVEN CONTROLLER. REPLACED G1A COFFEEMAKER PRECAUTIONARY. PERFORMED OPS TEST OF OVENS AND COFFEE MAKERS.SDR DALA13035425521Lamp · burned outON S/C, FOUND EMERGENCY ESCAPE PATH RED LIGHT INOPERATIVE BY R2 DOOR. REPLACED LAMPS AND SECURED CONNECTION. LIGHT CHECKED OK. REF AMM 33-51.SDR DALA13034805507Audio Panel · smokeEXPERIENCED STRONG GRAY ELECTRICAL SMOKE FROM THE F/O'S AUDIO SELECT PANEL DURING BOARDING. TURNED OFF UTILITY BUSSES AND SMOKE DISSIPATED. REPLACED PANEL.SDR DALA13034585531Oven · dirtySMOKING BURNING PLASTIC ODOR. MX INSPECTED CONFIRMED TWO MEAL CARRIER CONTAINERS CONTAINED BURNED PLASTIC RESIDUE-CARRIERS REMOVED FROM ACFT AND RENDERED UNSERVICEABLE. FURTHER INSPECT OF OVENS NOTED NO CONTAMINATION-HEATED OVENS WITH NO DEFECTS.SDR DALA13033975522Connector · looseEMERGENCY LIGHTS ARE NOT LIGHTING IN THE AFT PART OF CABIN RESEATED CONNECTOR PLUG AT BATTERY PACK M734 IN AFT GALLEY OVERHEAD OPERATED LIGHTS ON AND OFF SEVERAL TIMES CKS NORMAL IAW AMM 33-51. OK FOR SVC.
Back to Boeing 757-251