As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DIVERTED, SMOKE IN THE CABIN. IN GALLEY 1A FOUND WIRE 18 ON PLUG J003 NOT LOCKED IN CONNECTOR. REPINNED WIRE WITH NEW SOCKET. REPLACED OVEN BANK AND LT OVEN CONTROLLER. REPLACED G1A COFFEEMAKER PRECAUTIONARY. PERFORMED OPS TEST OF OVENS AND COFFEE MAKERS. PERFORMED CABIN INTERPHONE AND COMPARTMENT LIGHTING TEST. NO DISCREPANCIES NOTED.