Boeing 757-2B7
Service difficulty reports · 3,730
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAABB02055Battery · dischargedBDL - FOUND R2 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAA020185Skin · corrodedSKIN CORRODED STA 1310-1660 BETWEEN S27L-S27R AROUND FASTENERS. CLEARED, POLISHED AND BEAD BLASTED AREAS, TREATED AND PAINTED.SDR USAABB02051Battery · dischargedPHL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB02049Battery · dischargedBOS - FOUND LOW LEVEL EMERGENCY LIGHTS AT ROWS 13, 26, AND 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. M)SDR USAABB02048Battery · dischargedBOS - FOUND L2 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB02050Battery · dischargedMCO - FOUND LOW LEVEL EMERGENCY LIGHT AT ROW 1 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB02042Odor · detectedBWI - FLT 1800 - PASSENGER AND FLIGHT ATTENDANT NOTED AN ELECTRICAL SMELL IN THE CABIN. CREW CHECKED FOR ABNORMAL READINGS AND CIRCUIT BREAKER TRIPS. NO PROBLEM WERE FOUND. FLIGHT LANDED AT BWI WITH NO FURTHER INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT CSDR USAABB02040Battery · dischargedCLT - WITH ATTENDANTS PANEL SWITCH ON, MULTIPLE FLOOR LEVEL EMERGENCY LIGHTS WERE EXTINGUISHED. MAINTENANCE REPLACED ALL OF THE FLOOR LEVEL LIGHT BATTERIES. (M)SDR USAABB02039Battery · dischargedBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB02038Light · inoperativePIT - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 13 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB02035Battery · dischargedLAX - FOUND ALL FLOOR LEVEL EMERGENCY LIGHTS INOPERATIVE, ROWS 1, 4, 6, 9, 13, 18, 23, 26, 29 AND 33. MAINTENANCE REPLACED ALL TEN BATTERIES. (M)SDR USAABB02032Sign · inoperativeBDL - FOUND EXIT IDENTIFIER AT R1 DOOR INOPERATIVE. MAINTENANCE REPLACED THE EXIT IDENTIFIER ASSEMBLY. (M)SDR USAABB02031Light · inoperativeBDL - FOUND LOW LEVEL EMERGENCY LIGHT AT ROW 6 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB02030Battery · dischargedBDL - FOUND LOW LEVEL EMERGENCY LIGHTS AT ROWS 22 AND 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB02028Battery · dischargedBDL - FOUND L1 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB02023Switch · malfunctionedPIT - FLOOR LEVEL EMERGENCY ILGHT AT ROW 26 WOULD NOT EXTINGUISH. MAINTENANCE CYCLED THE EMERGENCY LIGHT SWITCH. (M)SDR USAABB02018Battery · dischargedBOS - FOUND LOW LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB02017Light · inoperativeCLT - FOUND FLOOR LEVEL EMERGENCY LIGHT INOPERATIVE AT ROW 29. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAA020079Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED 1 INCH BY 3 INCHES, STATION 377 LBL 45. CORROSION LEVEL 1, TASK NR C53-221-03. FABRICATED AND INSTALLED SEAT TRACK SECTION LBL 45 BETWEEN STATION 377 AND 440 PER SRM 53-00-52. (M)SDR USAA020078Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 20 INCHES LONG, STATION 377 LBL 25 AT SEAT TRACK ATTACH. CORROSION LEVEL 1, TASK NR C53-221-03. T-CAP FLOORBEAM REPAIR FROM LBL 51 TO LBL 13 PER T/R 53-15-01. (M)SDR USAA020077Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 20 INCHES LONG, STATION 377 LBL 45 AT SEAT TRACK ATTACH. CORROSION LEVEL 1, TASK NR C53-221-03. T/R 53-15-01 T-CAP FLOORBEAM REPAIR FROM LBL 51 TO LBL 13. (M)SDR USAA020080Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED 1 INCH BY 3 INCHES, STATION 377 LBL 25. CORROSION LEVEL 1, TASK NR C53-221-03. FABRICATED AND INSTALLED SEAT TRACK SECTION LBL 25 BETWEEN STATION 377 AND 440 PER SRM 53-00-52. (M)SDR USAABB02014Duct · leakingLAX - FLT 46 - CREW RECEIVED THE LEFT ENGINE 'OVHT' LIGHT AFTER TAKEOFF FROM LAX. FLIGHT RETURNED TO LAX AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE PERFORMED FIM PROCEDURES 26-11-00 AND RAN THE LEFT ENGINE FOR FIVE MINUTES. NO FAULTS WERE FOUND AND THSDR USAABB02013Link · brokenCLT - FLT 171 - AFTER TAKEOFF FROM CLT, CREW RECEIVED THE E/M 'GEAR DOORS' AND THE 'DOORS' LIGHT ILLUMINATED WHEN THE GEAR WAS RETRACTED. CREW EXTENDED THE GEAR AND LIGHT REMAINED ON. FLIGHT RETURNED TO CLT AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE RSDR USAABB02011Light · inoperativeCLT - FOUND FLOOR LEVEL EMERGENCY LIGHT INOPERATIVE AT ROW 9. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB02010Battery · dischargedBDL - FOUND SEAT MOUNTED EMERGENCY LIGHT AT ROW 13 DIM. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB02005Panel · looseCLT - FLT 803 - AFTER TAKEOFF, CREW NOTED AND IRRITATING, OILY ODOR IN THE COCKPIT. THE ODOR DIMINISHED WHEN THE LT PACK WAS SECURED, AND RETURNED WHEN THE PACK WAS OPERATED. THE LEFT PACK WAS SECURED FOR THE REMAINDER OF THE FLIGHT. MAINTENANCE REPLACED THSDR USAABB02002Light · malfunctionedCLT - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 ILLUMINATED. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB01156Sign · inoperativePHL - FOUND R1 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE ASSEMBLY. (M)SDR USAABB01154Light · malfunctionedMCO - FLOOR LEVEL EMERGENCY LIGHT AT ROW 1 REMAINED ILLUMINATED. MAINTENANCE CHECKED THE SYSTEM AND COULD NOT DUPLICATE THE DISCREPANCY. REPLACED THE BATTERY. (M)SDR USAABB01151Bolt · looseDEN - FLT 82 - EN ROUTE FROM SFO TO PHL, SMOKE IN THE COCKPIT. A HAZE WAS NOTICED IN THE CABIN. THE AFT LT LAV SMOKE DETECTOR SOUNDED, CREW SHUT DOWN BOTH RECIRCULATION FANS AND THEN RT PACK TO ISOLATE FAULT. THE AFT RT LAV SMOKE DETECTOR SOUNDED AND THE CRSDR USAABB02008Battery · dischargedBDL - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 9 AND 13, 26 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB01148Battery · dischargedBOS - FOUND EXIT IDENTIFIER FOR THE L1 DOOR INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB011146Battery Pack · dischargedBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 23 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK. (M)SDR USAABB01147Battery Pack · dischargedBDL - FOUND EXIT IDENTIFIER AT R3 DOOR INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK. (M)SDR USAA011402Frame · corrodedCLT - FOUND CHORD ANGLE CORRODED 1 INCH, FORWARD FACE OF FRAME STATION 263 RBL 10. REPLACED CHORD ANGLE. (M)SDR USAA011400Skin · dentedCLT - FOUND SKIN DENTED 20 INCHES, STATION 460 AND STATION 480 STRINGER 5 AND 6L. REPAIRED PER SRM 53-00-01 FIG 206. (M)SDR USAA011385Latch · corrodedCLT - FOUND DOOR LATCH BRACKET CORRODED 3 INCHES BY 3 INCHES, BS 600, FORWARD CARGO DOOR SILL. REPLACED PER SRM 51-10-00. (M)SDR USAABB01141Odor · detectedCLT - BAD ODOR EMANATING FROM THE AIR CONDITIONING SYSTEM. MAINTENANCE RAN THE PACKS WITH BOTH THE APU AND ENGINES AND COULD NOT DUPLICATE THE SMELL. THE MM OIL CONTAMINATION PROCEDURES WAS PERFORMED. BOTH RECIRC FILTERS AND ALL GALLEY VENT FILTERS WERE REPSDR USAA011401Skin · damagedCLT - FOUND SKIN REPAIRED 7 INCHES BY 8 INCHES, STATION 600 S16L. REPAIRED PER EA 66755A. (M)SDR USAABB01144Battery · dischargedMCO - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 4, 13 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB01143Light · inoperativePHL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 33 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAA011410Skin · dentedCLT - FOUND SKIN DENTED WITH A 1 INCH CREASE, STATION 331, S22R. REPAIRED PER EA 85791. (M)SDR USAA011399Skin · damagedCLT - FOUND SKIN WITH 1 INCH HOLE, BS 1695, STRINGER S20R. REPAIRED PER SRM 53-00-01 FIG 208. (M)SDR USAABB01140Sign · inoperativeMCO - FOUND R1 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE IDENTIFIER ASSEMBLY. (M)SDR USAABB01138Valve · failedPIT - FLT 1570 - IN CRUISE, CREW NOTED THAT THE LEFT DUCT PRESSURE WAS LOW (10 PSI). CABIN CREW ALSO NOTED A SLIGHT BURNING SMELL. MAINTENANCE REPLACED THE LEFT FAN AIR MODULATING VALVE. (M)SDR USAABB01135Socket · shortedCLT - ELECTRICAL SMELL IN CABIN NEAR ROW 29. MAINTENANCE FOUND THE CEILING LIGHTS SHORTED OUT AND REPLACED THE LIGHT SOCKET. (M)SDR USAABA01135Battery · dischargedFOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 13 AND 26 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES.SDR USAABB01132Battery · dischargedPHL - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 1 AND 18 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB01128Battery · dischargedPHL - FOUND SEVEN FLOOR LEVEL EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)
Back to Boeing 757-2B7