Boeing 757-2B7
Service difficulty reports · 3,730
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAABB01129Light · inoperativePHL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW FOUR INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB01126Battery Pack · dischargedMCO - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 6, 23, 26 AND 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACKS. (M)SDR USAABB01118Light · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 13 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB01112Light · inoperativePIT - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 9 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB01111Battery · dischargedBDL - FOUND FLOOR MOUNTED EMERGENCY LIGHTS AT ROWS 4, 6, 9, 13, 18, 23, 26, 29 AND 33 DIM. MAINTENANCE REPLACED ALL THE BATTERIES. (M)SDR USAABB0114Battery · dischargedBWI - FOUND EXIT IDENTIFIERS AT DOORS L3, R3 AND R4 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB0113Battery · dischargedBWI - FOUND FLOOR MOUNTED EMERGENCY LIGHTS AT ROWS 29 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB01110Light · inoperativeLAX - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 1 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB01109Battery · dischargedCLT - FOUND THE FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 1, 4, 6 AND 9 DIM. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAA011332Floorbeam · crackedCLT - FOUND FLOORBEAM STRAP CRACKED 2 INCHES, BS 365.25, LBL 27. INSTALLED DOUBLER REPAIR PER SRM 53-10-51. (M)SDR USAABB01106Battery · dischargedBDL - FOUNDS R4 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB01104Light · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 18 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB01105Light · inoperativeBDL - FOUND L2 EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAA011308Crease Beam · corrodedCLT - FOUND CREASE BEAM CORRODED .250 INCH BY .250 INCH, LEFT DOOR SILL AREA L4. REMOVED AND REPLACED PER SRM 51-10-00. (M)SDR USAABB01103Battery · inoperativePHL - FOUND FLOOR LEVEL EMERGENCY LIGHT INOPERATIVE AT ROW 29. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB01102Battery · dischargedCLT - FOUND R4 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAA011269Skin · dentedCLT - FOUND SKIN DENT .375 INCH WIDE BY .035 DEEP, LEFT FUSELAGE STATION 600 BETWEEN S15L AND S19L. INSTALLED REPAIR DOUBLER. (M)SDR USAABB01097Battery · dischargedPIT - FOUND FLOOR LEVEL EMERGENCY LIGHTS INOPERATIVE AT ROWS 1, 6 AND 25. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB01098Warning System · malfunctionedPHL - FLT 186 - ON APPROACH TO PIT, CREW RECEIVED THE EICAS MESSAGE 'GEAR DISAGREE' AND THE NOSE GEAR DOWN LIGHT DID NOT ILLUMINATE. WITH THE GEAR RETRACTED, A HEAVY VIBRATION FROM THE NOSE AREA WAS FELT AND THE GEAR DOORS LIGHT STAYED ILLUMINATED. THE CREW SDR USAABB01096Battery · dischargedCLT - FOUND FLOOR LEVEL EMERGENCY LIGHTS AT ROWS 1, 4, 6, 9, 13, 18, 23, 26 AND 29 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAA011227Frame · dentedFOUND FRAME DENTED .75 INCH BY 1.25 INCH, AFT CARGO BS 1540. INSTALLED REPAIR DOUBLER PER EA NR 85390. (M)SDR USAABB01095Coffeemaker · faultyPIT - FLT 36 - APPROXIMATELY FIVE MINUTES PRIOR TO LANDING, CREW NOTED AN ELECTRICAL SMELL IN THE AFT GALLEY. MAINTENANCE REPLACED THE 4B-11 COFFEEMAKER. (M)SDR USAABB01094Light · inoperativeBDL - FOUND LOW LEVEL EMERGENCY LIGHTS AT ROWS 4 AND 13 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLIES. (M)SDR USAA011208Frame · dentedCLT - FOUND FUSELAGE FRAME DENTED APPROXIMATELY .25 INCH BY .125 INCH, BS 580, 10 INCHES ABOVE TRANSITION ANGLE LEFT SIDE. CUT OUT DAMAGE, FABRICATE FILLER AND DOUBLER PER EA 85312. (M)SDR USAABB01093Light · inoperativeBDL - FOUND LOW LEVEL EMERGENCY LIGHT AT ROW 6 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAA011192Structure · crackedCLT - FOUND FLANGE CRACKED .5 INCH, BETWEEN BS 1620 AND BS 1640 BL 0. INSTALLED DOUBLER AND FILLER PER DRAWING 146N5180. (M)SDR USAA011191Frame · dentedCLT - FOUND FRAME DENTED 1 INCH BY 1 INCH, FORWARD CARGO, LEFT FRAME 10 INCHES ABOVE TRANSITION ANGLE. TRIM OUT DAMAGE, NDT AREA, INSTALL FILLER AND DOUBLER PER EA 85262. (M)SDR USAA011195Intercostal · corrodedCLT - FOUND INTERCOSTAL CORRODED 3 INCHES BY 5 INCHES, BS 395 AT RBL 12. REMOVED AND REPLACED PART NR 1840009 PER DWG NR 1840009. (M)SDR USAA011194Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED 3 INCHES BY 3 INCHES, BS 377.7 AT LBL 26. REMOVED AND REPLACED PART WITH PART NR 141N5131-1 PER DWG NR 141N5131-1. (M)SDR USAA011193Seat Track · corrodedCLT - FOUND SEAT TRACK CORRODED 3 INCHES BY 3 INCHES, BS 377.7 AT LBL 26. REMOVED AND REPLACED PART NR 141N5131-1 PER DWG NR 141N51311. (M)SDR USAA011187Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 2 INCHES, FS 377.7 AT LBL 49 AND LBL 21. REMOVED DAMAGED SECTION OF T-CAP AND INSTALLED NEW PER T/R 53-15-01 EA 69911. (M)SDR USAA011168Intercostal · corrodedCLT - FOUND INTERCOSTAL CORRODED 2 INCHES BY 4 INCHES, L1 DOOR THRESHOLD INTERCOSTAL AT BS 345, LBL 64. REMOVED AND REPLACED INTERCOSTAL PER SRM 51-40-02. (M)SDR USAA011167Angle · corrodedCLT - FOUND ANGLE CORRODED 2 INCHES BY 8 INCHES, ANGLE AFT OF L1 DOOR BS 395 AT LBL 64. BLENDED CORROSION PER 757 SRM 53-00-51 FIG 101. (M)SDR USAA011158Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED, BS 1640 RBL 22, 30, 36, 42, 49. REMOVED AND REPLACED T-CAP. (M)SDR USAABB01089Fcu · faultySEA - FLT 108/9280 - WHILE AWAITING TAKEOFF IN SEA, CREW RECEIVED A RIGHT IDG WARNING. FLIGHT WAS REDISPATCHED WITH THE RIGHT GENERATOR ON MEL AND THE APU OPERATING. APPROXIMATELY THIRTY MINUTES INTO FLIGHT, THE APU FAULTED AND SHUTDOWN. FLIGHT RETURNED TO SDR USAA011153Intercostal · crackedCLT - FOUND INTERCOSTAL CRACKED IN THREE PLACES 1 INCH EACH, BS 1660/1680 AT RBL 11. INSTALLED NEW INTERCOSTAL ANGLE PER DWG NR 14GN5191-39 SRM 51-40-05. (M)SDR USAABB01087Battery · inoperativeBDL - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 4 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAA011147Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED, BS 310.5 BL 0. REPAIRED FLOORBEAM PER SRM T-CAP REPAIR PER SRM 51-70-12. (M)SDR USAABB01085Battery · inoperativeBWI - FOUND THE EMERGENCY LIGHT AT ROW 9 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. OPERATIONAL CHECK GOOD. (M)SDR USAABB01086Light · inoperativeBWI - FOUND THE LIGHT ASSEMBLY AT ROW 1 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. OPS CHECK GOOD. (M)SDR USAA011143Floorbeam · corrodedCLT - FOUND CHORD CORRODED 2.5 INCH BY 53 INCHES, BS 1640 BL 0 TO RBL 53. INSTALLED NEW T-CAP AT BS 1640 BL 0 TO RBL 53. (M)SDR USAA011130Skin · damagedCLT - FOUND FUSELAGE SKIN WITH PREVIOUSLY INSTALLED DOUBLER 7 INCHES BY 7 INCHES, BS 1737 BETWEEN STRINGER 27L AND 29L. REMOVED DAMAGE, INSTALLED DOUBLER PER EA 66258A. (M)SDR USA011135Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .5 INCH, BS 365 RBL 60. (M)SDR USAA011134Floor Support · corrodedCLT - FOUND FLOOR SUPPORT CORRODED 20 INCHES BY 5 INCHES, BS 345 AND 365.25. (M)SDR USAA011133Floor Support · corrodedCLT - FOUND FLOOR SUPPORT CORRODED 1.5 INCH, BS 324 AND 6 INCHES INBOARD OF RIGHT FUSELAGE SKIN. (M)SDR USAA011132Floorbeam · corrodedFOUND FLOORBEAM CORRODED .5 INCH, BS 377 RBL 9. SPLICED IN NEW T-CAP SECTION PER TR 53-15-01. (M)SDR USAA011131Floorbeam · damagedCLT - FOUND FLOORBEAM WITH .5 INCH DAMAGE, BS 377 LBL 2. SPLICED IN NEW T-CAP SECTION PER TR 53-15-01. (M)SDR USAA011125SkinCLT - FOUND SKIN WITH LIGHTNING STRIKE, BS 620 - 2.5 INCH, BETWEEN STRINGER 18L AND 19L. DRILLED OUT DAMAGE AND INSTALLED RIVET PER SRM 53-00-01. (M)SDR USAABB01081Battery · inoperativeBOS - FOUND FLOOR LEVEL EMERGENCY LIGHT INOPERATIVE AT ROW 4. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB01080Battery · inoperativeBWI - FOUND FLOOR LEVEL EMERGENCY LIGHT AT ROW 26 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)
Back to Boeing 757-2B7