Boeing 767-306
Service difficulty reports · 2,510
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020082481806Valve · malfunctionedLT IDG VALVE STATUS. REMOVED AND REPLACED IDG AIR COOLING VALVE IAW AMM 24-11-07. GROUND RAN #1 ENG IAW AMM 71-00-00. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR UIEA2020081971784Lamp · inoperativeR BLEED ISOL VALVE LIGHT INOP. RELAMPED R BLEED ISOLATION VALVE SWITCH IAW SWPM 20-84-13. OPS CHECK GOOD AT THIS TIME.SDR UIEA2020081701781Warning Message · intermittentINTERMITTENT R ENG BLEED OFF EICAS MSG DURING FLIGHT PERFORMED FIM 36-10 FAULT TREE 837 AND PERFORMED ENG RUN. IAW AMM 71-00-00. OPS CHECK GOOD.SDR UIEA2020081801810Lamp · inoperativeRIGHT DOME MOUNTED EMERGENCY LIGHT IS INOPERATIVE. REMOVED AND REPLACED LAMP, OPS CHECKS GOOD IAW AMM 33-51-11.SDR UIEA2020081981809Pitot Tube · warning messageL AUX PITOT MSG AFTER STARTING RT ENG ON PUSH BACK. REMOVED AND REPLACED L AUX PITOT PROBE IAW AMM 34-11-01 OPS CHECK GOODSDR P5CA2020081870284Lamp · inoperativeRIGHT ENGINE SPAR VALVE LIGHT INOPERABLE. RELAMPED RT SPAR VALVE LIGHT IAW B767 AMM 33-13-00. OPS CHECK GOOD.SDR UIEA2020081871791Connector · dirtyPNEUMATIC PRESSURE READS APPROXIMATELY 22 PSI LOWER ON RIGHT SIDE COMPARED TO LEFT PNEUMATIC INDICATOR BAD FROM STOCK R/H INDICATOR READS INCORRECTLY REMOVED AND REPLACED DUCT PRESSURE INDICATOR IAW AMM 36-21-02, OPS CHECK GOOD. REINSTALLED PNEUMATIC INDICSDR UIEA2020081741772Gcu · faultedR AC BUS OFF EICAS MSG AT TOUCHDOWN PERFORMED BPCU BITE TEST IAW FIM 24-20 FT 801. FOUND RH GCU AT FAULT, REPLACED GCU IAW AMM 24-22-02. BITE TEST NO FAULTS. ENG RUN CKS GOOD IAW AMM 71-00-00.SDR UIEA2020081741773Status Message · false activationT-R UNIT EICAS STATUS MSG T/S IAW FIM 24-32 FT 803, NO FAULTS. MSG CLEARED, CKS OK.SDR UIEA2020081401770Oil System · lowAPU FAULT ON START AFTER LANDING 2ND ATTEMPTS HUNG AT 20% RPM. SERVICED APU OIL. PERFORMED BITE TEST ON APU CONTROL. STARTED APU, START OK PER MM 49-41-00. OPS CHECK GOOD.<BR /></P>)SDR UIEA2020081431763Indicator · dimSTANDBY ENGINE INDICATOR GAUGE IS SO DIM IT'S NEARLY IMPOSSIBLE TO READ.(<P>REMOVED AND REPLACED STANDBY ENG IND IAW B767 AMM 77-41-01. OPS CHECKS GOOD AT THIS TIME.<BR /></P>)SDR UIEA2020081421759Warning Message · false activationWINDSHEAR SYS EICAS MSG(<P>BITE CHK LEFT AND RIGHT WEATHER RADAR RECEIVERS IAW 34-43 FT 805. INPUT OK AND RADAR OK ON BOTH SIDES. OPS CHECKED IAW 34-43-00, NO FAULTS NOTED. FLT CREW RECEIVED FAULT ON R TRANSCEIVER, PLACED PN 066-50008-0408 ON ORDER AS PRECAUTISDR UIEA2020081401739Pump · faultedLH AFT BOOST PUMP PRESS LIGHT INOP(<P>TRANSFER TO MDDR 132659 IAW DDG 24-42-01-01 CAT C, DUE DATE 20 AUG-20.</P><P><SPAN>LP #1296963 ITEM 1: REMOVED AND REPLACED THE LH AFT BOOST PUMP IAW AMM 28-22-03, OPS CHECK GOOD. THIS CLEARS MDDR #132659. MCC NOTIFIED. PLSDR UIEA2020081401747Pump · faultedL AFT FUEL PUMP EICAS MSG IN CRUISE PRIOR TO ETOPS ENTRY. CIRCUIT BREAKER ALSO POPPED. AIR TURN BACK TO HNL(<P>REMOVED AND REPLACED L/H AFT BOOST PUMP IAW AMM 28-22-03 OPS CHECKS GOOD<BR /></P>)SDR UIEA2020081411750Radar · malfunctionedLEFT RADAR INOP(<P>PERFORMED WX TEST IAW AMM 34-43-00. TEST PASSED. MESSAGE CLEARED.<BR /></P>)SDR P5CA202008110278Warning Message · false activationON CLIMB/DEPARTURE FWD CGO BACKUP EICAS MSG AND FAULT LIGHT ILLUMINATED(<P>RAN QRH FWD CGO BACKUP MSG CLEARED - NO FAULT ACTIONS. PERFORMED OPERATIONAL CHECK OF THE COMPLETED OPS CHECK GOOD. FORWARD CARGO A/C IAW AMM 21-28-00. PERFORMED ZONE TEMPERATURE CONTROSDR P5CA202008110279Fault Message · false activationAPU FAULT ON EICAS, LEFT ENGINE START OCCURED PRIOR TO ANY MOVEMENT OF APU SELECTOR. PERFORMED APU ECU BITE CHECK IAW AMM 49-61-05. PERFORMED APU START AND SHUTDOWN PROCEDURES IAW AMM 49-11-00. NO DEFECTS NOTED.SDR P5CA202008110280Control Valve · failedAPU INOPERATIVE. REMOVED AND REPLACED THE SURGE CONTROL VALVE IAW AMM 49-53-01, BITE CHECKED GOOD. OPS CHECKED GOOD.SDR UIEA2020081231686Wire · damagedLH ENGINE FIRE LOOP 1 EICAS MSG INTERMITTENT (ENGINE FIRE DETECTION SYSTEMS , DETECTION LOOPS. REPLACED WIRES W5324-452R-16 AND W5324-454R-16 IAW SPM 20-10-11 AND WDM 26-11-11. OPS CKS GOOD IAW AMM 26-11-00.SDR UIEA2020080631686Fire Loop · intermittentLEFT ENGINE FIRE LOOP NR 1, EICAS MESSAGE INTERMITTENT.SDR UIEA2020080501712Warning Message · false activationAFT EQ EXH FAN 2 STATUS MESSAGE AFTER ENGINE START. PERFORMED FIM 21-26 FT 806. MSG CLEARED. NO FURTHER DEFECTS NOTED.SDR UIEA2020080401697Blade · nickedDURING WALK AROUND FOUND NICKS ON NR 2 ENG FAN BLADES, 5 BLADES WITH NICKS. PERFORMED FAN ROTOR BLADE INSPECTION IAW AMM 72-31-02. REPAIRED THE ROTOR FAN BLADES IAW AMM 72-31-02.SDR UIEA2020080311657Control Panel · inoperativeAPU INOPERATIVE. OPERATIONS NOT ALLOWED. REMOVED AND REPLACED APU CONTROL PANEL ASSY IAW AMM 49-11-81, OPS CHECKED NORMAL.SDR UIEA2020072801638Control Valve · failedAPU AIR PRESSURE DROPS TO 10 PSI AND STAYS AT 10 PSI DURING START. REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW AMM 49-53-01, OPS AND LEAK CHECKED GOOD.SDR UIEA2020072901643Warning Message · false activationAFT EQUIPMENT EXHAUST FAN NR 2 STATUS MESSAGE. PERFORMED A TEST IAW 21-58-49. STATUS MESSAGE CLEARED. OK FOR SERVICE.SDR UIEA2020073071627Circuit Card · failedAFTER BLOCK OUT FWD EQPT OVHT EICAS MSG. AFTER QRH CHECKLIST ACCOMPLISHED, MSG STAYED EXTINGUISHED. T/S FIM 2158 FAULT TREE 999 FOUND VALVE ASSY AIR MODULATION INOP. REMOVED AND REPLACED VALVE ASSY AIR MODULATION IAW AMM 21-58-07. OPS TESTED OK. BOTH PACKS RSDR UIEA2020072971624Modulating Valve · inoperativeAFT CABIN TEMP CONTROL INOPERATIVE, PERFORMED A ZONE TEMP CONTROL BITE IAW FIM 21-60, FT 804. FOUND AFT TRIM VALVE INOPERATIVE. REMOVED AND REPLACED THE TRIM AIR MODULATING VALVE AFT CABIN IAW AMM 21-61-07. CHECKEDD GOOD.SDR UIEA2020072971634Warning Message · false activationSTATUS MESSAGE FOR WX SYS. CYCLED THE RT WXR SYS CIRCUIT BREAKER IAW FIM 34-43, TASK 801. MESSAGE CLEARED. OPS CHECKED GOOD.SDR UIEA2020072971630Heat Exchanger · crackedDURING DAILY CHK NOTICED ODOR COMING FROM A/C DUCTS, UPON INSP FOUND L/H PACK CONDENSER HEAT EXCHANGER CRACKED. REMOVED AND REPLACED L/H PACK HEAT EXCHANGER CONDENSER ASSY IAW AMM 21-51-10. OPS CHECK NORMAL. NO LEAKS NOTED.SDR UIEA2020072951613Adi · failedAT CRUISE, FL 330, CAPTAIN`S ADI FLICKERED THEN FAILED. AFTER SCREEN FAILED A STRONG ODOR AND NOXIOUS FUMES BECAME APPARENT ON GROUND, SAW ADI CIRCUIT BREAKER TRIPPED. PERFORMED INSPECTION OF CAPTAIN'S ADI. DETERMINED FAILURE OF CRT. REMOVED AND REPLACED THESDR UIEA2020072701628Warning Message · false activationHI FLOW INHIBIT DISPLAYED DURING CLIMB. FAULT COULD NOT BE DUPLICATED AT THIS TIME, SYS CKS NORMAL IAW REF FIM 21-51-875. PERFORMED T/S SYSTEM IAW FIM 21-51 FT 813. NO FAULTS NOTED. CHECKED GOOD.SDR UIEA2020072701629Switch · malfunctionedSPRING ON EMERGENCY LIGHT INOPERATIVE. REPOSITIONED THE EMERGENCY LIGHT TOGGLE SWITCH ARMING ARM, IAW MM 33-51-08. OPS CHECKED GOOD IAW 33-51-00.SDR UIEA2020072631604Duct · tornDURING APU INSPECTION, FOUND AIR SURGE DUCT TORN BEFORE SURGE VALVE. REMOVED AND REPLACED AIR SURGE DUCT BEFORE SURGE VALVE IAW AMM 49-53-01. OPS CHECKED NORMAL. NO LEAKS DETECTED.SDR UIEA2020072301605Warning Message · false activationRECEIVED A WINDSHEAR SYS EICAS AND WXR FAIL MESSAGE DURING TAXI OUT, WITH RT RADAR ON, SWITCHED TO LT, SYSTEM AND MESSAGE CLEARED. COMPLIED WITH A WEATHER RADAR TEST IAW AMM 33-43-00. NO EICAS MESSAGE PRESENT.SDR UIEA2020072301606Warning Message · false activationLEFT ENG EEC C1 STATUS MESSAGE. COMPLIED WITH ENG RUNS IAW AMM 72-00-00. NO STATUS MESSAGE PRESENT. COMPLIED WITH A BITE OF THE LT PIMU IAW FIM 73-21 FT 885. NO MESSAGES PRESENT.SDR UIEA2020072201597Fuel Filter · warning messageRIGHT ENGINE FUEL FILTER EICAS MESSAGE DISPLAYED TWICE DURING CLIMB. MESSAGE LASTED A FEW SECONDS THEN BECAME A STATUS MESSAGE. REMOVED AND REPLACED THE RT FUEL FILTER. NO FUEL FILTER STATUS, OPS AND LEAK CHECKED OK IAW AMM 73-11-02.SDR UIEA2020072101592Accelerometer · malfunctionedLEFT ENGINE VIB INDICATION INOPERATIVE. R & R THE NR 1 ENGINE ACCELEROMETER IAW 77-31-02, AND PERFORMED ENGINE RUNS IAW 71-00-00, OPS CHECKED GOOD.SDR UIEA2020072201598Warning Message · false activationHI FLOW INHIBIT STATUS MESSAGE. PERFORMED FIM 21-51, FT 813, SHUTDOWN LT AND RT PACKS FOR 15 SECONDS, SWITCHED THEM TO ON POSITION, VERIFIED MESSAGE DOES NOT COME BACK, SYSTEM CHECKED GOOD.SDR UIEA2020072211590Warning Message · false activationHIGH FLOW INHIBIT MESSAGE ON EICAS. BITE TESTED LT PACK CONTROLLER IAW AMM 21-51-00. NO FAULTS NOTED. RESET LT PACK CONTROLLER. MESSAGE CLEARED.SDR UIEA202007271577Valve · warning messageFWD EQUIP VALVE EICAS AFTER ENGINE START, MOVED SWITCH TO STAND BY MSG DID NOT CLEAR. REMOVED AND REPLACED OVERBOARD EXHAUST VALVE IAW AMM 21-58-05.SDR UIEA202007271578Outflow Valve · malfunctionedAFT EQUIP EX FAN 2 STATUS MESSAGE. REMOVED AND REPLACED OVERBOARD EXHAUST VALVE IAW AMM 21-58-05.SDR UIEA2020072100577Warning Message · illuminatedFWD EQUIPMENT VALVE EICAS AFTER ENGINE START, MOVED SWITCH TO STANDBY, MESSAGE DID NOT CLEAR.SDR UIEA2020072100578Status Message · illuminatedAFT EQUIPMENT EXHAUST FAN 2 STATUS MESSAGE.SDR UIEA2020072001583Status Message · false activationSTATUS MESSAGES: AIR/GRD DISAGREE, CABIN ALTITUDE AUTO 2, LANDING GEAR MONITOR. PERFORMED GROUND TEST IAW AMM 32-90-01, TEST PASSED, PERFORMED GROUND TEST IAW 21-31-00, TEST PASSED. PERFORMED GROUND TEST IAW AMM 32-61-00, MESSAGE CLEARED. OK FOR RETURN TO SERSDR UIEA2020072001582Oxygen Mask · malfunctionedFIRST OFFICER`S OXYGEN MASK WOULD NOT TEST DURING PRE-FLIGHT. PULLED THE MASK OUT AND AFTER 1-2 MINUTES OF TESTING IT STARTED WORKING. REMOVED AND REPACKED THE OXYGEN MASK IN STORAGE BOX. OPS CHECKED GOOD IAW MM 35-11-00.SDR UIEA2020071701564Gcu · faultedLEFT GENERATOR OFF EICAS MESSAGE IN FLIGHT, RAN CHECKLIST, TURNED APU ON, MESSAGE REMAINED. REMOVED AND REPLACED THE LT GENERATOR CONTROL UNIT IAW AMM 24-22-02-004-001 AS PART OF T/S.SDR UIEA2020071501555Warning System · false activationAPU FAULT MESSAGE ON FIRST START ATTEMPT AFTER LANDING, SECOND ATTEMPT STARTED NORMALLY. PERFORMED BITE CHECK OF APU ECU. NO FAULTS FOUND, REF AMM CHAP 49-00-00.SDR UIEA2020072411545Clamp · looseLEFT ENGINE FIRE LOOP 1 INOPERATIVE. PERFORMED A FIRE LOOP RESISTANCE MEASUREMENT IAW FIM 26-11 FAULT TREE 804 TABLE B, RESISTANCE FOUND WITHIN THE RANGE AND NO MESSAGE IS SHOWN. MCC NOTIFIED. PERFORMED TROUBLESHOOTING OF THE ENGINE FIRE DETECTION LOOP, RESDR UIEA2020071741545Fire Loop · malfunctionedLEFT ENG FIRE LOOP 1 INOPERATIVE. PERFORMED A FIRE LOOP RESISTANCE MEASUREMENT IAW FIM 26-11, FAULT TREE 804, TABLE B, RESISTANCE FOUND WITHIN THE RANGE AND NO MESSAGE IS SHOWN.SDR UIEA2020071401540Warning System · false activationON LANDING FWD EQUIP VLV EICAS MESSAGE DISPLAYED. PERFORMED OPS CHECK MANIFOLD INTERCONNECT VALVE AND OVERRIDE VALVE. REF AMM 21-58-00-705-161-008 REV 130, OPS CHECK GOOD.
Back to Boeing 767-306