Boeing 767-306
Service difficulty reports · 2,510
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019070504684Control Valve · malfunctionedLEFT PACK TEMP EICAS MSG AND AUTO SHUT DOWN(<P>REMOVED AND REPLACED LEFT PACK TEMPERATURE CONTROL VALVE IAW AMM 21-51-12 OPS CHECK GOOD </P>)SDR P5CA2019070500144Valve · faulty FWD CABIN TEMP EICAS MESSAGE APPEARED DURING CRUISE (<P>UPON INSPECTION FOUND INOP LIGHT ILLUMINATED T/S PER FIM 21-60 FT 806 BITE CHECK ZONE TEMP CONTROLLER. FOUND FWD CABIN ZONE TRIM AIR VALVE LIGHT ON. ITEM TRANSFERRED TO MDDR 114274 PER DDG 21-61-04-02 CASDR UIEA2019070404671Idg · lowRIGHT GENERATOR DRIVE EICAS MESSAGE INTERMITTENT. (<P>SERVICED ENG # 2 IDG REF 12-13-03 AND PERFORMED ENGINE RUN REF AMM 71-00-00. IDG COMES ONLINE AS REQUIRED, PUT A LOAD, NO DEFECTS NOTED AT THIS TIME. A/C OK FOR SERVICE. </P>)SDR UIEA2019070404673Control Valve · malfunctionedRIGHT PACK TEMP EICAS MESSAGE. (<P>C/W BITE CHECK ON TEMP CONTROL BOX IAW AMM 21-51-00. FOUND FAULT ON TEMP CONTROL VALVE, REPLACED RIGHT TEMP CONTROL VALVE AND OPS CHECKED IAW AMM 21-51-12-004-001/404-013. OPS CHECK GOOD, NO FAULTS NOTED. </P>)SDR UIEA2019070304668Placard · missingCOCKPIT FIRST AID KIT IN OVERHEAD BINS MISSING PLACARD, P/N 368-11-00-91615-429. (<P>LOCATED AND INSTALLED NEW PLACARD AT COCKPIT OVERHEAD BIN IAW AMM 20-10-13-964-001.</P>)SDR UIEA2019070304667Warning System · false activationAFT EQ COOLING FAN 2 STATUS MSG (<P>AFT EQ EXH FAN 2 DEFERRED PER MEL 21-58-05. THIS BECOMES DMI 114127, CAT 'C', DUE 12JUL19. <BR /></P><P>LP 1080455 - M6: C/W FIM TASK 21-26 FAULT TREE 809. FIM TEST PAST, NO DEFECTS NOTED. THIS CLEARS DMI #114127. MCC NOTIFISDR UIEA2019070104627Ecu · malfunctionedAPU PRODUCED 21 PSI FOR #2 ENGINE START AND ONLY 10 PSI FOR #1 ENGINE START. CROSS START REQUIRED. (<P>TRANSFERRED TO MDDR 114030 IAW MEL 49-11-01-01. PNEUMATIC FUNCTION OF APU INOP. CAT 'C', DUE 11-JUL-19. R&R APU SURGE BLEED OPS CHECK GOOD IAW AMM 49-53-01SDR P5CA2019070100138Screen · dirty"FWD CABIN TEMP" EICAS WITH FWD CAB INOP LIGHT ALSO ILLUMINATED. (<P>CLEANED FWD CABIN TEMP SENSOR SCREEN IAW AMM 21-61-00. OPS CHECK GOOD AT THIS TIME.</P>)SDR UIEA2019070204654Warning System · false activationRT PACK TEMP EICAS MSG.(<P>PERFORMED BITE TEST CHECK ON TEMP CONTROLLER COMPT IAW FIM 21-51-803. NO FAULTS NOTED AT THIS TIME ON RIGHT HAND PACK.</P>)SDR UIEA2019070204655Control Unit · malfunctionedLEFT PACK TEMP EICAS MSG.(<P>PERFORMED BITE TEST ON LEFT PACK TEMP CONTROL UNIT IAW FIM 21-51-803. NO FAULTS NOTED AT THIS TIME, OPS TEST OK.</P>)SDR UIEA2019063004623Isolation Valve · closedAPU ONLY PRODUCED 10 PSI FOR #1 ENGINE START. CROSS START REQUIRED TO START ENGINE 1.(<P>FOUND RT ISOLATION VALVE CLOSED. VALVE RESET, CYCLED, OPERATE OK REF 36-15-00.</P>)SDR UIEA2019063004619Warning System · false activationR PACK TEMP EICAS MESSAGE ON GROUND. EICAS MESSAGE WENT AWAY AFTER A FEW MOMENTS. (<P>PERFORMED RT PACK OPS TEST AND BITE TEST OF RT PACK TEMP CONTROLLER IAW AMM 21-51-00. NO FAULTS NOTED AT THIS TIME.</P>)SDR P5CA2019062800136Valve · malfunctionedFWD EQUIPMENT VALVE ADVISORY MESSAGE. REMOVED AND REPLACED DAMAGED EQUIPMENT COOLING EXHAUST DUCT IN FWD LOWER CARGO FLOOR WITH NEW. LEAK CHECKS GOOD IAW AMM 27--58-05. REMOVED AND REPLACED OVERBOARD EXHAUST VALVE IAW AMM 21-58-05 OPS AND CHECKS LEAK CHECSDR UIEA2019062864590Idg · malfunctionedLT GENERATOR DRIVE LIGHT AND EICAS MESSAGE AFTER ENGINE START. REACTIVATED IDG ON LT ENG IAW AMM 24-11-01. SERVICED IDG IAW AMM 12-13-03. RAN LH ENG. IDG OPS CHECK GOOD. PER MCC REQUEST. DEACTIVATED LT ENG IDG IAW DDG PROCEDURES. REMOVED AND REPLACED THE SDR UIEA2019062704601Bowl · damagedNR 1 ENGINE OIL SCAVENGE FILTER BOWL WAS DAMAGED. REMOVED, INSPECTED, AND INSTALLED THE NR 1 ENGINE OIL SCAVENGE FILTER BOWL IAW AMM 79-21-04 AND 79-21-08. NO DAMAGE NOTED. LEAK CHECK ACCOMPLISHED ON T/C T2031.SDR UIEA2019062704602Ecu · no testAPU ECU FAILS OPS CHECK WITH "ECU" MINI FLAG. REMOVED AND REPLACED ECU IAW B767 AMM 49-61-05.SDR UIEA2019062704603Gcu · failedDURING PERIODIC BUSS POWER CONTROL UNIT TEST, RECEIVED "LEFT GEN CT LOOP GROUND DISCONNECT TRIP". REMOVED AND REPLACED L GCU. PERFORMED SATISFACTORY OPS CHECK IAW AMM 24-22-02.SDR UIEA2019062704604Terminal · brokenDURING ENGINE RUN PNEUMATIC CHECKS, LH PRV NOT OPENING. TROUBLESHOOT PER FIM 36-10 848. FOUND BROKEN TERMINAL LUG AT PIN 3 Y347. REPAIRED BROKEN TERMINAL LUG AT PIN 3 Y347 IAW SWPM 20-30-11. PERFORMED SATISFACTORY OPS CHECK IAW AMM 36-11-18.</P>)SDR UIEA2019062704605Mount · wornFWD CARGO L/H SIDE AIR COOLING FAN AFT MOUNT IS WORN.(<P>REMOVED AND REPLACED FWD CARGO L/H SIDE AIR COOLING FAN AFT MOUNT IAW B767 AMM 21-58-06. PERFORMED A SATISFACTORY POST FAN INSTALLATION CHECK. NO LEAKS NOTED IAW B767 AMM 21-58-06.</P>)SDR UIEA2019062804613Lanyard · unsecureMAIN ENTRY DOOR ESCAPE ROPE FELL OUT WHEN OPENING ENTRY DOOR. MISSING SNAP ON STORAGE BAG. SECURED SNAPS ON ESCAPE ROPE COVER IAW SRM 51-40-02, OPS NORMAL.SDR UIEA2019062654574Service Port · looseON WALK AROUND, OIL NOTICED SEEPING UNDER LH ENGINE IDG SERVICE DOOR(<P>FOUND IDG SERVICE PORT NECK LOOSE AT IDG HOUSING. SECURED FITTING AND SERVICED IDG IAW AMM 12-13-03. PERFORMED ENGINE RUN IAW AMM 71-00-00-712-168-H03, NO LEAKS NOTED. OK FOR SERVICE </P>)SDR P5CA2019062540132Terminal · looseRH ENG OVERHEAT LOOP 1 STATUS MSG. T/S IAW FIM 26-11 FT 804, TESTED FIRE DETECTION SYSTEM, NO FAULTS OR MESSAGES FOUND. INSP FIRE O/H CARDS, RE-RACKED AND SECURED. NO FAULTS FOUND. T/S PER WDM 26-11-22. CONTINUITY AND MEG CHECK OF WIRE OK. REMOVED AND REPLACEDSDR UIEA2019062104549Pressure Switch · failedWITH FUEL IN CENTER TANK 1200LBS LEFT CENTER FUEL PUMP PRESSURE LIGHT ON WHEN OPERATING PUMP EICAS. REMOVED AND REPLACED LEFT CENTER PUMP PRESSURE SWITCH IAW AMM 28-42-01. PERFORMED TEST AND SYSTEM OK. RESET BREAKERS.SDR UIEA2019062104550Unknown · noiseBLEED AIR NOISE IN COCKPIT REACHES 78.3 DB AT CLIMB POWER. COULD NOT DUPLICATE ON GROUND. OPS CHECK OF PACK SYSTEM GOOD IAW AMM 21-51-00. T/S FLIGHT DECK BLEED AIR NOISE IAW AMM 21-22-00. NO DEFECTS NOTED. RAN RH ENGINE TO TRY TO DUPLICATE THE NOISE IAW AMM SDR UIEA2019062104548Bpcu · failedAFTER START OR THE NR 2 ENGINE, GEN DRIVE LIGHT ILLUMINATED SELF EXTINGUISHED AFTER 1 MINUTE. SERVICED THE IDG IAW AMM 12-13-03. OPS CHECKED GOOD. BPCU SHOWS NO FAULTS. REMOVED AND REPLACED BPCU IAW AMM 24-41-03. OPS CHECKED GOOD.SDR UIEA2019062104546Idg · failedDURING CRUISE FLIGHT, LEFT GEN OFF EICAS, AND LEFT GEN & LEFT DRIVE LIGHTS APPEARED. QRH WAS RUN, APU STARTED, FLT CONTINUED. T/S DISCREPANCY AND SWAPPED L/H & R/H GCUS AND PERFORMED ENGIEN RUN. NO VOLTS OR FREQUENCY ON LEFT ENGINE. CONFIRMED LEFT IDG TO BE BSDR P5CA201906210129Fire Detector · faultedR ENG OH LP 1 STATUS MESSAGE PRIOR TO BLOCK OUT. REMOVED UPPER FWD FIRE DETECTOR IAW AMM 26-11-02-024-001. REPLACED DETECTOR IAW AMM 26-11-02-141-038. PERFORMED OPS CK PER AMM SUBTASK 26-11-02-861-002, OPS CK GOOD. THIS ACTION CLEARS MDDR 113417.</P>)SDR UIEA2019062004531Warning Message · false activationAT FL 400, L GEN OFF EICAS MSG WITH OTHER ASSOCIATED EICAS MSG. PERFORMED L GEN OFF QRH CHECKLIST AND ALL MSG CLEARED W/GEN RESET. PERFORMED BPCU BITE PROCEDURE IAW FIM 24-20 FT 801, NO FAULTS NOTED AT THIS TIME. VERIFIED LH IDG OIL LEVEL, LEVEL OK REF AMM 12-SDR UIEA2019062004535Warning Message · false activation"RIGHT PACK TEMP" EICAS, RIGHT PACK OVERHEAT.(<P>PERFORMED PACK TEMPERATURE CONTROLLER BITE TEST REF AMM 21-51-14-705-035. COULD NOT DUPLICATE MESSAGE. OPS CHECK OK AT THIS TIME.</P>)SDR P5CA2019062100130Controller · malfunctionedFWD CABIN TEMP EICAS. RESET ZONE TEMP CONTROLLER IAW AMM 21-61-00. NO DEFECTS NOTED.SDR UIEA2019061434486Pump · warning messageLEFT CTR FUEL PUMP PRESS LIGHT ILLUMINATED AND L CTR FUEL PUMP EICAS MSG (AMBER). REMOVED AND REPLACED LEFT CENTER OVERRIDE PUMP IAW AMM 28-22-05. LEAK CHECK GOOD, TRANSFERS GOOD, PRESS LIGHT GOOD.SDR UIEA2019061324469Status Message · false activationSTATUS MESSAGE, LEFT ENGINE SPEED CARD. PERFORMED OPS CHECK IAW PER B767 AMM 77-12-00. OPS CHECKED GOOD, NO STATUS MESSAGE DISPLAYED.SDR UIEA2019061424472Relay · failedL FWD FUEL PUMP INOPERATIVE. LIGHT STAYS ILLUMINATED DURING PUMP OPERATION. REMOVED AND REPLACED RELAYS K512 + K505 AT P37 PANEL, NO FIX, REF B767 SWPM 20-81-22. TROUBLESHOT IAW FIM 28-25 FT 808 AND WDM 28-25-11-1 PAGE 1. REMOVED AND REPLACED RELAY K513 ISDR UIEA2019061204468Pump · malfunctionedLEFT CENTER FUEL PUMP INOP. PERFORMED OPS CHECK OF PUMP PER AMM 28-22-01. OPS CHECK GOOD.SDR UIEA2019061304442Fan · inoperativeFWD EQUIPMENT EXHAUST STATUS MESSAGE. PERFORMED FIM TASK 21-58 FAULT TREE 905 AND FOUND FWD EQ EXH FAN TO BE INOP. REMOVED AND REPLACED THE FORWARD RACK EXHAUST FAN. INSTALLATION CHECKED GOOD PER AMM 21-58-06.SDR UIEA2019061104457Idg · malfunctionedEICAS MSG "RT GEN OFF". TROUBLESHOT RT GEN OFF MSG. REMOVED AND REPLACED BUS POWER CONTROL UNIT IAW B767 AMM 24-41-03. BPCU TEST GOOD. OVER VOLTAGE TRIP FAULT WAS RECORDED ON LAST FLT WAS REASON. NO FAULTS PRESENT AT THIS TIME. REMOVED AND REPLACED RIGHT ENGSDR UIEA2019061204476Escape Reel · missingDESCENT DEVICE IN POSITION 'G' IS MISSING. INSTALLED MISSING DESCENT DEVICE IN POSITION 'G' IAW AMM 25-61-05. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR UIEA2019061204477Flow Divider · unknownREMOVED AND REPLACED APU FUEL FLOW DIVIDER IAW B767 AMM 49-31-03-404-017. OPERATIONAL CHECK GOOD. LEAK CHECK GOOD. </P>)SDR UIEA2019061204478Charger · failedAPU BATTERY CHARGER FAILS TEST IAW EO 6749A003 PART 1. REMOVED AND REPLACED APU BATTERY CHARGER IAW B767 AMM 24-31-05. OPS CHECK GOOD. </P>)SDR UIEA2019061084440Gcu · malfunctionedTHRU 18,000 AFTER TURNING TAXI L&R TURNOFF LIGHTS & WING LANDING LIGHTS, ENTIRE 2 AC BUS FAILED. "R AC BUS ISLN" CAUTION MSG. RAN QRH & COMPLIED. A MAYDAY CALL WAS DECLARED. MULTIPLE SYSTEMS FAILURES OCCURRED DURING REST OF DESCENT. SDR UIEA2019061074429Connector · not seatedSTANDBY PACK TEMP CONTROLLER FAILS BITE TEST "RIGHT COMP SENSOR" RESEATED CONNECTORS TO TS5134 AND TS5135 OPS CHECK GOOD IAW AMM 21-51-14-705-036, 21-51-06, SSM 21-50-06, 21-50-05, WDM 21-51-23, 21-51-13.SDR UIEA2019061074430Unknown · damagedL/H SIDE WINDOW HEAT PB IS DAMAGED. REMOVED AND REPLACED L/H SIDE WINDOW HEAT PB IAW B767 AMM 30-41-02 AND SWPM 20-84-15. PERFORMED SAT OPS CHECK IAW AMM 30-41-02 AND 33-13-00. NO DEFECTS NOTED.SDR UIEA2019061074431Warning Message · missingEICAS IS MISSING INDICATION ON RT "PRIM HX IN". PERFORMED BITE TEST FOR MR SUPPLY BITE MODULE IAW B767 AMM 36-11-16-745-135 BITE PASSED INDICATION PRESENT.SDR UIEA2019061074432Valve · malfunctionedR/H ENG FAV CLOSED AND OPEN SWITCHES DISAGREE. REMOVED AND REPLACED THE R/H ENG FAV (SUPPLY PRE-COOLER VALVE) IAW B767 AMM 36-11-15. PERFORMED SATISFACTORY OPS CHECK IAW B767 AMM 36-11-15.</P>)SDR UIEA2019061074433Door · excess playNR 2 ENG OB CORE COWL PRESSURE RELIEF DOOR HAS PLAY. REMOVED AND REPLACED NR 2 ENG OB CORE COWL PRESSURE RELIEF DOOR HINGE PINS AND RELATED HARDWARE IAW B767 AMM 71-11-09.SDR UIEA2019061074434Connector · corrodedNR 1 ENG IGNITION BOXES HAVE CORROSION ON CANNON PLUG CONNECTION RECEPTACLES. REMOVED AND REPLACED BOTH IGNITION EXCITER BOXES AND PERFORMED SATISFACTORY OPS TESTS #1 ENG IAW AMM 74-11-01 AND AMM 74-00-00.SDR UIEA2019060704435Plug · gougedNR 2 OB BORESCOPE PLUG B3-1 GOUGED. REMOVED AND REPLACED #2 ENG BORESCOPE PLUG B3-1 IAW AMM 72-00-00. LEAK CHECK ACCOMPLISHED ON TC T2031.SDR UIEA2019061074437Wire · brokenRIGHT PACK CONTROLLER BITE FAILS MX MAN SENSOR. FOUND AND RETERMINATED BROKEN WIRES AT CONNECTOR D2826 IAW B767 WDM 21-51-22 PERFORMED SATISFACTORY OPS CHECK IAW B767 AMM 21-51-14. NO DEFECTS NOTED. FAULT CLEARED.SDR UIEA2019061004446Unknown · damagedLH SIDE WINDOW HEAT P/B IS DAMAGED. REMOVED AND REPLACED LH SIDE WINDOW HEAT P/B IAW AMM 30-41-02 AND SWPM 20-84-15. PERFORMED OPS CHECK IAW B767 AMM 30-41-02 AND 33-13-00 NO FAULTS NOTED.SDR UIEA2019061004448Filter · trippedLEFT HYD BAY RETURN FILTER MODULE PRESSURE INDICATOR POPPED. REMOVED AND REPLACED LH HYD RETURN FILTER IN LH PYLON IAW B767 AMM 29-11-17. ACCOMPLISHED OPS CHECK IAW B767 AMM 29-11-00, 29-11-17 AND 71-00-00 NO DEFECTS NOTED. </P>)
Back to Boeing 767-306