SDR UIEA2018083001848Wire · damagedRT ENG FIRE LOOP 2 INTERMITTENTLY DISPLAYED(STATUS MESSAGE). REMOVED AND REPLACED WIRE W5306-455R-16 AT RT ENG REPLACED WITH NEW BMS513-67 WIRE MATERIAL, RE CLAMPED & RETERMINATED WIRE TO ENG LOOP 2 TS682% A & TS683 A IAW WDM 26-11-21, SWPM 20-10-12 & 20-10-15SDR UIEA2018090401883Fire Loop · damagedRIGHT ENGINE FIRE LOOP2 PERMANENT REPAIR. C/W HIGH TEMP TAPE IAW SWP 20-10-13, WIRE W-5324-455R-16 TO BE REPLACED DURING THE NEXT A CHECK.SDR UIEA2018083001846Modulating Valve · faultyAFT CAB TEMP EICAS MESSAGE ON TAXI IN. REMOVED AND REPLACED AFT CABIN TRIM OUR MODULATING VALVE IAW AMM 21-61-01-004-006 AND 21-61-404-041 OPS CHECKS GOOD.SDR UIEA2018082801826Generator · faultyAPU LOW OIL SHUTDOWN. REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01. OPS CHECK GOOD.SDR UIEA2018082701806Warning System · false activationRIGHT ENGINE FIRE LOOP 2 STATUS MESSAGE DISPLAYED AFTER NR 2 ENGINE START. NO CURRENT FAULTS, PERFORMED FIRE/OVERHEAT TEST IAW AMM 26-11-00.SDR UIEA2018082701809Warning System · false activationAFTER LANDING, RIGHT FWD WINDOW EICAS MSG COMPLIED WITH QRH. MSG CLEARED. OPS CHECK IAW AMM 30-41-00. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018082601796Connector · looseREPEAT WRITE UP (04TH TIME) REFERENCE AIRCRAFT LOG DATES 22AUG18, 25AUG18, 25AUG18, EICAS MSG RT FWD WINDOW. PERFORMED INSPECTION OF WINDOW HEAT WIRING, FOUND LOOSE CONNECTIONS AT CB C392 WITH CARBON BUILDUP. CLEANED AND TIGHTENED CONNECTION ALL WORK PERFORMEDSDR UIEA2018082501792Warning System · false activationAFTER LANDING RIGHT FWD WINDOW EICAS MESSAGE. PERFORMED OPS CHECK IAW AMM 30-41-00. NO FAULT NOTED AT THIS TIME.SDR UIEA2018082201775Warning System · false activationAFTER LANDING RECEIVED RIGHT FWD WINDOW ADVISORY MSG, COMPLIED WITH QRH, MSG CLEARED. OPS CHECK IAW AMM 30-40-01, NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018082101763Warning System · false activationRT ENG NR 2 FIRE LOOP STATUS MESSAGES, INTERMITTENT DURING FLIGHT. PERFORMED FIRE DETECT OPS CHECK IAW AMM 26-11-00, RT ENG LOOPS. NO DEFECTS NOTED.SDR UIEA2018082101757Apu · shutdownAPU FAULT FIRST ATTEMPT AUTO SHUTDOWN, SECOND ATTEMPT SUCCESSFUL. PERFORMED APU BITE CHECK IAW FIM 49-11 FT 988, PERFORMED OPERATIONALTEST IAW AMM 49-11-00, OPS NORMAL.SDR UIEA2018082101759Sensor · faultyAPU AUTO SHUT DOWN. BITE CODE "REVERSE FLOW". T/S IAW FIM 49-11 FT 987. R&R LC TT SENSOR IAW AMM 49-61-03. APU OPS CHK GOOD PER 49-00-00. ERASED ECU PER FIM 49-11 FT 987. NO DEFECTS AT THIS TIME.SDR UIEA2018082201768Plenum · contaminatedAT CRUISE, APPROX 5 MIN AFTER APU START A STRONG ODOR WAS DETECTED. AFTER APU SHUTDOWN THE ODOR DISSIPATED. IT CAME BACK DURING DESCENT AT APPROX 60,000, WITH L PACK OFF THE ODOR WAS LESS NOTICEABLE. PERFORMED FIM 21-00-21 LEFT PACK. FOUND NO TRACES OF OIL IN SDR UIEA2018081801736Circuit Card · faultyONBOARD FLIGHT CREW REPORTED RT ENGINE FIRE LP 2 STATUS MESSAGE DURING NR 2 ENGINE START. MSG CLEARED SHORTLY AFTER. REMOVED AND REPLACED NR 2 ENGINE LOOP 2 CONTROL/FIRE OVERHEAT CARD, PRECAUTIONARY OPERATIONAL CHECKOF ENG/APU CARGO FIRE/OVERHEAT TESTED GOOD NSDR UIEA2018081701733Warning System · false activationRT ENGINE FIRE LOOP 1 STATUS MESSAGE DISPLAYED AFTER ENGINE START, MESSAGE EXTINGQUISHED. FLIGHT PERFORMED SYSTEM TEST FIRE DETECTION SYSTEM IAW AMM 26-11-00, OPS CHECK GOOD.SDR UIEA2018081801738Warning System · false activationRIGHT FORWARD WINDOW EICAS ON TAXI IN. PERFORMED WINDOW HEAT OPS CHECK IAW AMM 30-41-00, NO FAULTS NOTED AT THIS TIME.SDR UIEA2018082201770Warning System · false activationAPU FAULT ON FIRST START, SECOND ATTEMPT SUCCESSFUL. PERFORMED APU STARTING AND OPERATION PROCEDURE, NO DEFECTS NOTED AT THIS TIME PER AMM 49-11-00-802-002.SDR UIEA2018091101945Engine · chafedLT ENGINE BEHIND GEAR BOX EWIS CHAFING. NR 1 REMOVED AND REPLACED ON T/C E1029-1, FAS W/O N1229-01-01.SDR UIEA2018081501703Warning System · false activationRT FWD WINDOW HEAT. ACCOMPLISHED OPS CK OF WINDOW HEAT SYSTEM IAW 30-11-00, OPS CK GD, NO DEFECTS NOTED.SDR UIEA2018081501695Fire Loop · defectiveRT ENG FIRE LOOP 2 INOP. INSPECTED AND RESISTANCE CHECK OF RT ENG LOWER AFT DETECTOR FAILING WHEN SHAKING/NOT WITHIN LIMITS. REPLACEDLOWER AFT DETECTOR IAW AMM 26-11-02. OPS CHECK IAW AMM 26-22-00, TEST OK.SDR UIEA2018081301668Status Message · activatedRIGHT ENGINE FIRE LOOP 2 STAUS MESSAGE. TRANSFERED TO MDDR 97917 IAW MEL 26-11-01-01 CAT C PLACARD INSTALLED.SDR UIEA2018081301669Switch · malfunctionedRT FWD WINDOW HEAT EICAS AFTER LANDING. RESET R FWD WINDOW SWITCH IAW AMM 30-41-00 OPS CHECKS GOOD ON GROUND.SDR UIEA2018081301679Warning System · false activationRIGHT FWD WINDOW EICAS MESSAGE RECEIVED AFTER LANDING. PERFORMED OPS CHECK OF FLIGHT COMPARTMENT WINDOW ANTI ICING SYSTEM GOOD IAW AMM 30-41-00, NO DEFECT NOTED AT THIS TIME.SDR UIEA2018081401689Switch · malfunctionedRT FWD WINDOW HEAT EICAS AFTER LANDING. RESET R FWD WINDOW SWITCH IAW 30-41-00/501. OPS CHECK GOOD, NO EICAS MESSAGE.SDR UIEA2018081201662Warning System · false activationSTATUS MESSAGE RT ENG FIRE LOOP 2 AFTER ENGINE START, MSG GOES AWAY AFTER TAKE OFF. C/W FIM 26-11 FAULT TREE 806 NO FAULTS AT THIS TIME.SDR UIEA2018081201663Switch · malfunctionedRT FWD WINDOW HEAT EICAS AFTER LANDING. RESET RFWD WINDOW SWITCH IAW AMM 30-41-00. OPS CHECK GOOD, NO EICAS MSG.SDR UIEA2018081301670Warning System · false activationRT ENG FIRE LOOP NR 2 WAS INTERMITTENT DURING ALL PHASES OF A/C OPERATION AFTER ENG START. T/S IAW FIM 26-11 FT 804 & WDM 26-11-21. LOOP 2 RT ENG RESISTANCE VALVE FALLS IN RANGE PER FIG 104 SHEET II. INSULATION CHECK IS WITHIN RANGE PER FIG SHEET II. NO DEFECTSDR UIEA2018081301672Starter · malfunctionedLT STARTER WOULD NOT CUT OUT. R&R LT ENGINE STARTER IAW AMM 80-11-01. OPS GOOD.SDR UIEA2018080701632Warning System · false activationRT FWD WINDOW EICAS MESSAGE ON AFTER LANDING REPEAT WRITE UP. PERFORMED OP/BITE TEST IAW AMM 30-44-00, TEST PASSED. OPS GOOD.SDR UIEA2018080601627Warning System · false activationRT FWD WINDSHIELD EICAS MSG WITH RT FWD W/S HEAT INOP LIGHT. PERFORMED BIT TEST OF WINDOW HEAT CONTROLLER IAW AMM 30-41-00, NO FAULTS NOTED.SDR UIEA2018080601626Warning System · false activationON LANDING RT FWD WINDOW HEAT MSG AND INOP LIGHT ILLUMINATED. PERFORMED OPS /BIT TEST IAW AMM 30-41-00. NO FAULTS, OPS GOOD.SDR UIEA2018080801640Shutoff Valve · faultyFWD CARGO AIR CONDITIONING EICAS MESSAGE. R&R CARGO A/C SOV IAW AMM 21-28-01-404-92.SDR UIEA2018080801641Packing · damagedFUEL IS LEAKING FROM LT WING BOOST PUMP PANEL 532AB. R&R MOTIVE FUEL SCREEN PACKING LT FWD BOOST PUMP, PERFORMED SAT LEAK CK IAW AMM 28-11-03.SDR UIEA2018080601625Circuit Card · faultyRT ENG FIRE LP2 STATUS MSG ON PUSHBACK. REMOVED AND REPLACED AFOLT CARD M10274, P/N 285N0027-136 IAW 26-10-01. OPS CHECK GOOD AT THIS TIME.SDR UIEA2018080301621Warning System · false activationRIGHT ENGINE FIRE LOOP 2 STATUS MSG. PERFORMED FIM TASK 26-11 FAULT TREE 806, NO FAULT NOTED. OK FOR SERVICES.SDR UIEA2018080301622Start Valve · failedRT START VALVE FAILED TO OPEN. REMOVED AND REPLACED RT ENG STARTER VALVE IAW AMM 80-11-02, OPS CHECK LEAK GOOD.SDR UIEA2018080301610Relay · failedAFTER BOTH ENGINE STARTED AND IGNITION SELECTED IN AUTO RECEIVED " LEFT START CUTOUT MESSAGE WITH NO LIGHT. COMPLIED WITH QRH CHECK. LEFT ENGINE ISOLATION VALVE MESSAGE EXTINGUISHED. REMOVED AND REPLACED NR 1 ENGINE START CONTROL RELAY IN REFERENCE TO SWPM 20-SDR UIEA2018080201606Warning System · false activationRIGHT FWD WINDOW EICAS MSG ON TOUCHDOWN. ACCOMPLISHED FIM 30-41 TASK 802 STEP A, NO DEFECTS FOUND OK FOR SERVICE.SDR UIEA2018080101598Warning System · false activationRIGHT FWD WINDOW EICAS. PERFORMED BITE TEST IAW 34-41-00, NO FAULTS FOUND OK FOR SERVICE.SDR UIEA2018073101594Unknown · malfunctionedWX RANGER DISAGREE ON CAPT'S HSI DISPLAY ALL RANGES INTERMITTENT. CAPT SIDE ONLY LT SYS REPEAT WRITE UP. PERFORMED FAULT ISOLATION PROCEDURES AS PER FIM 34-43 FT 104 AND EFIS BITE TEST IAW FIM 34-22 FIG 108, FOUND OK.SDR UIEA2018080101596Warning System · false activationRT FORWARD WINDOW HEAT EICAS AFTER LANDING. PERFORMED BITE TEST IAW 30-41-00, NO FAULTS FOUND OK FOR SERVICE.SDR UIEA2018080101602Unknown · malfunctionedRADAR WX DEPLICTION VERY WEAK NEED FULL GAIN ON SYSTEMS 1 AND 2. PERFORMED BITE TEST AS PER FIM 34-43 FAULT TREE 205 TEST PASS NO FAULTS FOUND.SDR UIEA2018080101601Warning System · false activationRT FWD WINDOW EICAS MSG. PERFORMED RT FWD WINDOW ANTI-ICE OPERATIONAL TEST IAW AMM 30-41-00. OPS CHECK GOOD, MESSAGE ERASED.SDR UIEA2018073001582Warning System · false activationRT FWD WINDOW EICAS MSG. PERFORMED RT FWD WINDOW ANTI-ICE OPERATIONAL TEST IAW 30-41-00. OPS CHECK GOOD. MESSAGE ERASED.SDR P5CA2018073100170Controller · failedAPU BLEED AIR NO BLEED AIR PRESSURE FROM APU. REPLACED APU INLET GUIDE VANE ACTUATOR IAW AMM 49-52-02. P/N A64847-5 S/N1514 APU OPER STILL NO PNEUMATIC FUNCTION. APUC BITE P2 SENSEN FAULT REF FIM 49-11 FT A21. REPLACED APUC IAW 49-01-04. OPERATED APU PACKS. ADSDR UIEA2018073001580Warning System · false activationSTATUS ANNUNCIATION " WXR RANGE DISAGREE" ON CAPTAINS HSI DISPLAYED WHEN RANGE SELECTED OUTSIDE OF 80NM (LT SYS). PERFORMED FIM 34-43 FT 809. NO FAULTS OR MESSAGES NOTED AT THIS TIME. OPS NORMAL.SDR P5CA2018073100171Inverter · not reportedSTBY INVERTER REMOVED AND REPLACED. STATIC INVERTER PER AMM 24-33-03. OPS CHECK OK.SDR P5CA2018073100169Isolation Valve · failedLEFT BLEED ISOLATION VALVE STATUS MESSAGE. SWAPPED LEFT ISOLATION VALVE WITH CENTER ISOLATION VALVE AND TESTED LEFT ISOLATION VALVE IAW AMM 36-11-04 OPS CHECK GOOD. REMOVED AND REPLACED CTR ISOLATION VALVE IAW AMM 36-11-04 TEST OK.SDR UIEA2018072701565Warning System · false activationSTATUS MESSAGE BLOCK: RT ICE DETECTOR, LT ICE DETECTOR. REF FIM 30-81, FT 803, MESSAGE CLEARED WITH NO OTHER FAULTS NOTED AT THIS TIME.SDR P5CA2018072400143Check Valve · malfunctionedAPU PNEUMATIC FUNCTION INOP. REMOVED AND REPLACED APU PNEUMATIC CHECK VALVE IAW AMM 36-11-11. OPS CHECK GOOD AT THIS TIME.
Back to Boeing 767-306