Boeing 767-306
Service difficulty reports · 2,510
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767306' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2018072301533Control Unit · faultyRIGHT FWD WINDOW HEAT MESSAGE DISPLAY. FOUND WIRING TO BE ROUTED INCORRECTLY AROUND R1 WINDOW, PERFORMED CHECK OF WIRE ROUTING ALL THE WAY RT WINDOW WINDOW HEAT CONTROL UNIT IAW WPM 30-41-12. FOUND LOOSE AND CONTAMINATED CONNECTOR D4294P CLEANED AND RE-SECUREDSDR UIEA2018072301535Warning System · activatedFWD CARGO A/C EICAS MSG AND COND CARGO VALVE STATUS MESSAGE DISPLAYED. TRANSFERRED TO MDDR 96902 AS PER MEL 21-28-01 CAT D.SDR UIEA2018072301536Not Reported · malfunctionedRIGHT FWD WINDOW. PERFORMED WINDOW HEAT BITE TEST AS PER AMM 30-41-00. NO FAULTS NOTED AT THIS TIME.SDR UIEA2018072101528Controller · faultySTATUS PAGE RT ENG HPSOV. RT ENG HPC FAULT ON AIR SUPPLY BITE MODULE. REMOVED AND REPLACED RT ENGINE HP CONTROLLER IAW AMM 36-11-08. LEAK AND OPS CHECK OK.SDR UIEA2018081901746Warning System · false activationRT FWD WINDOW EICAS MSG ON TAXI IN. PERFORMED WINDOW HEAT OPS CHECK IAW AMM 30-41-00, NO FAULTS NOTED.SDR UIEA2018071901517Not Reported · malfunctionedAPU INOP WILL NOT SUPPLY BLEED AIR. TRANSFERRED TO MDDR 96746 IAW MEL 49-11-01A CAT C DUE DATE 29JUL18 PLACARD INSTALLED.SDR UIEA2018071801515Warning System · false activationRT FWD WINDOW EICAS MSG ON LANDING. PERFORMED OPS FOR WINDOW HEAT IAW AMM 30-41-00. OPS GOOD AT THIS TIME.SDR P5CA2018071800138Shutoff Valve · malfunctionedRT ENGINE BLEED OFF EICAS MSG AFTER START, NO BLEED PRESSURE. PER AMM 36-11-09 REPLACED RIGHT ENGINE PRSOV AND LEAK CHECK, NO LEAK LEAK FOUND.SDR P5CA2018071800137Relief Valve · malfunctionedRT ENGINE BLEED/PACK OFF LIGHT REMAINS ON AFTER ENGINE START DUCT PRESSURE RT 0 UNTIL THRUST IS INCREASED. IAW AMM 36-11-18 REMOVED AND REPLACED RT ENGINE PRV AND PERFORMED LEAK CHECK NORMAL IAW AMM 36-13-00 PERFORM AIR SUPPLY CONTROL BITE TEST AND NO FAULTS FSDR UIEA2018071601476Clamp · not seatedPNEUMATIC CLAMP NOT SEATED PROPERLY. RE-SEATED CLAMP, FUNCTION CHECK PASSED.SDR UIEA2018071601477Starter · wornAPU STARTER MOTOR BRUSH WEAR INDICATOR IS WORN. REMOVED AND REPLACED STARTER IAW AMM 49-41-11.SDR UIEA2018071601479Feeder Cable · damagedLEFT AND RIGHT IDG'S POWER FEEDERS INSULATION DAMAGED. REMOVED AND REPLACED LEFT AND RIGHT IDG'S POWER FEEDER INSULATION IAW AMM 20-30-14.SDR UIEA2018071601486Ignition Lead · cutNR 1 ENGINE INBD SIDE (BRACKET) CUT THROUGH UPPER IGNITER LEAD. REMOVED AND REPLACED LEAD, OPS CHECK GOOD.SDR P5CA2018071800136Packing · damagedRT ENGINE BLEED LIGHT STAYS ON AFTER START UNTIL POWER IS INCREASED. INSPECTION FOUND PRV MUSCLE AIR TUBE DAMAGE, REMOVED AND REPLACED PACKING AND PERFORM LEAK TEST OK IAW AMM 36-11-18.SDR UIEA2018071501466Control Panel · defectiveLT ENG START SW DID NOT STAY IN GND POSITION ON 1ST ATTEMPT. ON 2ND ETTEMPT, SWITCH OPERATED NORMAL. REMOVED AND REPLACED GROUND START CONTROL PANEL IAW AMM 80-11-51. RAT NEEDS TO BE CYCLED. PERFORMED RAT OPS CHECK IAW AMM 29-21-00. OPS CHECK GOOD - EXTENDED &SDR UIEA2018071201445Oil System · leakingAPU INOP. WHILE SEARCHING FOR SOURCE OF SMELL PERFORMED GVI OF LEFT PACK AS PER AMM 21-51-00 FOUND EVIDENCE OF OIL AT DUCT FWD OF AC BEFORE TRIM AIR VALVE, LT PACK CLEAN OIL ON AN DIN DUCTS AS PER AMM 21-00-21, CLEANED RESIDUAL OIL IN MIXING MANIFOLD AS PER AMSDR P5CA2018071300133Warning System · false activationRT ENG STARTER CUTOUT AFTER START, SHUT DOWN ENGINE, MSG CLEARED. NORMAL START- 2ND ATTEMPT. RT ENG SAV OPERATION CHECK NORMAL WITH MOTORING IAW AMM 71-00-00.SDR P5CA2018071300134Shutoff Valve · malfunctionedRT ENG BLEED LIGHT STAYS ON AFTER START UNTIL POWER IS INCREASED. RT ENG HPSOV PFM THUMB TEST ONLY. 10 SEC, R&R RT ENG HPSOV PFM ENG RUN TEST, NO LEAK FND. COND CHK NML IAW AMM 36-11-07, 71-00-00.SDR UIEA2018071001416Shutoff Valve · malfunctionedFWD CARGO A/C EICAS MESSAGE DISPLAYED. DEACTIVATED FWD CARGO A/C SHUTOFF VALVE PER ACTION PLAN 14302 PERFORMED WIRING CHECK.SDR UIEA2018071101429Apu · inoperativeAPU INOP. THIS ITEM DEFERRED UNDER 49-11-01A, CAT "C". DUE DATE: 20JUL18.SDR UIEA2018071001426Shutoff Valve · faultyRT ENG HPSOV STATUS. DEFERRED RT ENG HPSOV IAW DDG 36-11-02-02, REF M5 FOR TR DEACTIVATION REQUIRED BY DDG 36-11-02-02.SDR UIEA2018071001411Status Message · intermittentRT ENG FIRE LOOP 2 STATUS INTERMITTENT. TROUBLESHOOT PER FIM 26-11 FAULT TREE 806. NO DEFECTS NOTED AT THIS TIME. OPS CHECKS GOOD. A/C OK FOR SERVICE.SDR UIEA2018071001425Unknown · malfunctionedRT FWD WINDOW HEAT. PERFORMED OPS CHECK OF WINDOW HEAT/FLT. COMPARTMENT ANTI-ICE SYSTEM IAW AMM 30-41-00-715-001. OPS CHECK GOOD AT THIS TIME.SDR UIEA2018070901405Warning System · false activationSTATUS MSG AFT EQ EXH FAN 2. PERFORMED FIM 21-26 FAULT TREE 808 SYS NORMAL, CLEARED.SDR UIEA2018070901403Warning System · false activationRT FWD WINDOW EICAS AFTER LANDING REPEAT WRITE UP. PERFORMED FLIGHT COMPARTMENT WINDOW ANTI-ICE SYSTEM OPERATIONAL TEST, OPS CHECK GOOD AS PER AMM 30-41-00.SDR UIEA2018070901402Warning System · false activationRT FWD WINDOW EICAS AFTER LANDING. PERFORMED FLIGHT COMPARTMENT WINDOW ANTI-ICE SYSTEM OPERATIONAL TEST, OPS CHECK GOOD PER AMM 30-41-00.SDR P5CA2018071100111Fire Detector · faultyRT ENG FIRE LP 2 STATUS MESSAGE. REMOVED AND REPLACED RT ENGINE UPPER AFT FIRE DETECTOR. OPERATIONAL TEST PASSED IAW AMM 26-11-02.SDR UIEA2018071001415Unknown · odorSTRANGE OFFENSIVE ODOR EMANATING FROM THE AIRCRAFT VENTILATING SYSTEM WHEN THE PACKS ARE RUNNING. PERFORMED INSPECTION FOR SMOKE AND FUMES FROM AIRCRAFT VENTILATION SYSTEM IAW AMM 05-51-56, NO OFFENSIVE ODOR OR SMOKE DETECTED AT THIS TIME.SDR UIEA2018070801385Relay · faultyFWD CARGO A/C EICAS MSG DISPLAYED ON PUSHBACK. REPLACED FWD CARGO AC VALVE PER AMM 21-28-01. OPS NO GOOD. REMOVED AND REPLACED RELAY K01212 IAW SWOM 20-61-00 SHOW NO FAULTS. P/N BACR13CF2A.SDR UIEA2018070801384Warning System · false activationRT FWD WINDOW EICAS DURING TAXI AFTER LANDING. PERFORMED FLIGHT COMPARTMENT WINDOW ANTI-ICE SYSTEM OPERATIONAL TEST, OPS CHECK GOOD PER AMM 30-41-00.SDR UIEA2018070801383Warning System · false activationSTATUS MSG, AFT EQ EXH FAN 2. PERFORMED FIM 21-26 FT 808 SYSTEM NORMAL, MSG CLEARED.SDR P5CA2018071100108Contact · dirtyRT ENG FIRE LP 2. PERFORMED FIRE TEST & INSPECTION. CAK CONTACTED CLEANED, OPS CHK AS PER AMM TASK 26-11-00-16501.SDR UIEA2018070901395Warning System · false activationREPEAT WRITE UP - RT FWD WINDOW HEAT EICAS MESSAGE. PERFORMED OPS CHECK IAW AMM 30-41-00 OPS CHECK GOOD NO DEFECTS NOTED, CHECK MAIN PINS FOR SPARES FA195, FC 192 CHECKED GOOD, CHECK WIRE CONNECTORS D2898A, AFT PIN 19 WIRE CHECK GOOD, CHECKED WIRE D2998B PIN 5SDR P5CA2018070500109Controller · not seatedAPU BLEED INOP. RE-RACKED APUC & OPS CHK OK AS PER AMM TASK 49-11-00-802-002.SDR UIEA2018070401334Warning System · false activationON LANDING RIGHT FWD WINDOW EICAS. PERFORMED FLIGHT COMPARTMENT OPS TEST. OPS CHECK GOOD PER AMM 30-41-00-715-001.SDR UIEA2018070401335Warning System · false activationRT FWD WINDOW HEAT EICAS MESSAGE CAME ON AFTER LANDING. COULD NOT DUPLICATE AT THIS TIME. INTERCHANGED LEFT AND RIGHT WINDOW HEAT CONTROLLERS REF AMM 30-41-01, BOTH SYSTEMS CHECK NORMAL AT THIS TIME. P/N OFF 624066-5, S/N OFF 030C-4104 POS RT.SDR UIEA2018070501341Warning System · false activationLT BLEED DUCT LEAK CAUTION MESSAGE. RESET BLEED SYSTEM IAW AMM 21-51-00, OPS GOOD.SDR UIEA2018070301327Control Unit · malfunctionedAPU INOP. REMOVED AND REPLACED APU CONTROL UNIT IAW MM 49-61-05. APU PNEUMATIC CHECK GOOD.SDR UIEA2018070301329Warning System · false activationRIGHT FWD WINDOW EICAS ON TAXI IN. PERFORMED FLIGHT COMPARTMENT WINDOW ANTI ICING SYSTEM OPERATIONAL TEST, OPS CHECK GOOD PER AMM 30-41-00-715-001.SDR UIEA2018070201315Shutoff Valve · faultyON START AT RIGHT ENG NO SPAR VALVE LIGHT. R&R SPAR FUEL SHUTOFF VALVE IAW AMM 28-21-02. OPS CHECKED GOOD.SDR UIEA2018070201316Warning System · false activationTR FWD WINDOW HEAT EICAS ON LANDING. PERFORMED FLIGHT COMPARTMENT WINDOW ANTI-ICING SYSTEM OPERATIONAL TEST, OPS CHECKED GOOD PER AMM 30-41-00-715.SDR UIEA2018070201317Warning System · false activationRT FWD WDW EICAS MESSAGE ON TAXI IN. CHECKED WIRE 713-24 AS PER WIRING DIAGRAM 30-41-12. OPS CHECK GOOD.SDR UIEA2018070201319Warning System · false activationRT ENG HPSOV STATUS MESSAGE UPON SHUTDOWN. INSPECTED,TORQUE AND PERFORMED. OPS TEST OF HPSOV IAW AMM 36-11-07, MSG CLEARED NO FURTHER FAULTS NOTED AT THIS TIME. OPS TEST SATISFACTORY.SDR UIEA2018070301323Warning System · activatedON START OF RIGHT ENG- NO SPAR VALVE "LIGHT". DISPATCH NOTIFIED.SDR UIEA2018070101301Status Message · false activationAFTER BLOCK OUT FIRST ENGINE START, RT ENGINE FIRE LOOP STATUS MESSAGE, WENT OUT AFTER T/O. TROUBLE SHOT NR 2 ENGINE FIRE LOOP IAW FIM 26-11 F/T 806, NO DEFECTS NOTED. OPS CHECK GOOD AT THIS TIME.SDR UIEA2018070101302Warning System · false activationRT FWD WINDOW MSG AFTER LANDING MULTIPLE REPEAT WRITE UP. PERFORMED BITE PROCEDURES FOR RT FWD WINDOW HEAT IAW FIM 30-41 FT 804. NO DEFECTS NOTED, OPS CHECK GOOD AT THIS TIME.SDR P5CA2018070200105Status Message · false activationRT ENG FIRE LP2 STATUS MSG. PERFORMED CHECK PER FIM 26-11 FAULT TREE 804 AND CHK NML.SDR UIEA2018062901293Warning System · false activationAFTER LANDING RECEIVED EICAS RT FWD WINDOW. PERFORMED BITE PROCEDURE FOR RT FWD WINDOW HEAT AS PER FIM 30-41 FT 804. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018062901291Wire · not seatedRT FWD WINDOW EICAS AFTER LANDING. PERFORMED BITE CHECK ON WINDOW HEAT CONTROLLER IAW AMM 30-41-00. CLEANED & RESEATED WINDOW HEAT WIRING AS PER AMM 56-11-01, OPS CHECK OK.SDR UIEA2018062901292Warning System · false activationAFTER ENGINE START STATUS MSG, RT ENG FIRE LP 2 DISPLAYED ON LOWER EICAS. PERFORMED OPS CHECK OF RIGHT ENGINE FIRE LOOP IAW AMM 26-11-00. OPS CHECK GOOD AT THIS TIME, A/C OK FOR CONTINUED SERVICE.
Back to Boeing 767-306