SDR UIEA2020090981959Warning Message · false activationLT ENG FIRE LP 1 STS MSG APPEARED IN FLT. TESTED LT ENG FIRE LP 1, IAW AMM 26-11-01, FAULT COULD NOT BE DUPLICATED.SDR UIEA2020083191893Radar · unknownWX RADAR INOP(<P>PERFORMED OPS TEST IAW FIM 34-43 FAULT TREE 805. OPS CHECK GOOD. NO FAULT NOTED AT THIS TIME</P>)SDR UIEA2020082491816Pressure Switch · malfunctionedR CENTER FUEL PUMP. VERIFIED C1 PUMP OPERATING. PULLED AND COLLARD RT CENTER PUMP JT 2145Z. "1". OPS CHECKED RT CENTER FUEL PUMP IAW 28-22-00. NO FAULTS NOTED, BOOST PUMP OPS GOOD. REMOVED AND REPLACED FUEL PRESSURE SWITCH CENTER IAW 28-42-00. OPS CHECKED GSDR UIEA2020081411748Apu · malfunctionedAPU FAULT. APU WOULD NOT START. THREE ATTEMPTS MADE.(<P>PERFORM BITE AND SELF TEST OF ECU PER B767 AMM 49-61-05 START ABORT MESSAGE DISPLAYED. NO FAULTS NOTED AT THIS TIME. APU START BY MX SUCCESSFUL. OPS CHECK GOOD.<BR /></P>)SDR UIEA2020080321675Clamp · looseRIGHT BLEED DUCT LEAK ILLUMINATED AT FL 410. PERFORMED INSPECTION. FOUND AIR SUPPLY DUCT CLAMP LOOSE. SECURED AND REINSTALLED PER AMM 21-51-23. OPS NORMAL. LEAK CHECKED NORMAL.SDR UIEA2020080325614Skin · crackedCRACK INDICATION NOTED ON LH LOWER WING SKIN STA 990.2 STR L 9.5 HOLE 1 AT APPROX 12 O'CLOCK POSITION LOOKING AFTPERFORMED DOUBLER, TRIPLER, AND FILLER REPAIR ON LH LOWER WING SKIN STA 990.2 STR L 9.5 IAW EO 6757A088 AND SB AP767-57-010 R12SDR UIEA2020080326616Skin · crackedCRACK INDICATION NOTED ON THE RT LOWER WING SKIN WS 990.2 STR 9.5, HOLE 1 AT APPROX 12 O'CLOCK POSITION LOOKING FWD. PERFORMED A DOUBLER, TRIPLER, AND FILLER REPAIR IAW EO 6757A088, AND SB AP767-57-010 R12.SDR UIEA2020063001447Unknown · malfunctionedFLT DECK TEMP UNCONTROLLABLE FLT DECK TEMP (28-26)C. PERFORMED BITE CHECK ON ZONE TEMP CONTROLLER IAW AMM 21-61-03 FOUND NO FAULTS. MOVED TEMP CONTROLLER TO FULL C AND FULL W IAW AMM 21-51-00, PACK PROVIDED COLD AND HOT AIR OPS CHECK GOOD.SDR UIEA2020070201472Fuel Filter · faultedEICAS MSG R ENG FUEL FILT (W/ ASSOCIATED STATUS MSG) AT HIGH THRUST CONDITIONS. MSG EXTINGUISHED AT CRUISE THRUST. FOLLOWED FIM 73-11 T/R 863, REMOVED AND REPLACED FUEL FILTER ELEMENT PER AMM 73-11-02. PERFORMED NR 2 ENGINE RUN PER AMM 71-00-00. OPS CHECKSDR UIEA2020061801310Elt · inoperativeELT INOPERATIVE. REMOVED AND REPLACED THE ELT IAW EO SB034-0220-00, REV 3. OPS CHECKED NORMAL.SDR UIEA2020061531280Fault Message · false activationAPU FAULT ON GROUND, BITE CHECK OF THE APU ECU IAW AMM 49-61-05 AND SELF TEST. NO FAULT FOUND. OPS CHECKED GOOD IAW AMM 49-11-00.SDR UIEA2020052901148Warning System · false activationLEFT PACK TEMP ILLUMINATED IN FLIGHT, INOPERATIVE LIGHTS STAYS ILLUMINATED. PERFORMED RESET AND & TEST OF PACK TEMP CONTROLLER IAW AMM 21-51-00. NO FAULTS FOUND.SDR UIEA2020052701128A/C Pack · noisyON GROUND AND CLIMB TO FL180 PACK OUTPUT NOISE LEVEL DETRIMENTAL TO COCKPIT COMMUNICATION. OPS CHECKED PACKS IAW AMM 21-51-00. NO DEFECTS NOTED. ALL OPS NORMAL.SDR UIEA2020051801066Symbol Generator · malfunctionedRT FLT DIRECTOR INOP ON CLIMB OUT(<P>REMOVED AND REPLACED RT SYMBOL GENERATOR PER B767 AMM 34-22-01. OPS CHECK GOOD.</P>)SDR UIEA2020051601043Control Valve · malfunctionedRIGHT PACK TEMP EICAS MESSAGE(<P>RESET R PACK CONTROLLER. RT PACK OPERATES NORMAL IN STANDBY MODE, REF AMM 21-61-00. TRANSFERRED TO MDDR 128437 PER DDG 21-51-03-01, CAT 'C', DUE 26MAY2020.</P><P>LP 1150826: REMOVED AND REPLACED PAX TEMP CONTROL VALVE IAW AMM 2SDR UIEA2020051401035Unknown · malfunctionedRIGHT PACK AUTO FUNCTION INOP(<P>TRANSFER TO MDDR 128348 IAW DDG 21-51-03-01, CAT C, DUE DATE 24-MAY-20.</P><P>14MAY, ONT. LOG PAGE 1137900, ITEM M3: PERF BITE OF R/H TEMP CONTROLLER IAW FIM 21-51 F/T 844, NO FAULTS NOTED. OPERATED R/H PACK ON/OFF AND WITH BOTSDR UIEA2020051201019Filter · dirtyEQUIPMENT COOLING FILTER DIRTY.(<P>REMOVED AND REPLACED EQUIPMENT COOLING FILTER IAW AMM 21-58-30. NO ODOR IN FLT DECK NOTED. OPS CHECK NORMAL AT THIS TIME.<BR /></P>)SDR UIEA2020051101005Unknown · odorON APPROACH STRONG DIRTY PACK SMELL(<P>PERFORMED PACK SYSTEM TEST ON BOTH REF AMM 21-51-00/501. NO SMELLS ON GROUND AFTER RUNNING BOTH PACKS SEPARATELY. OK FOR RTS.</P>)SDR UIEA2020051101010Cooling Fan · failedNOTICEABLE ODOR CHEMICAL OR SMELLS LIKE WET PAINT WITH THRUST CHANGES ON CLIMB OUT AND DESCENT.(<P>INSPECTED FILTER IAW 21-58-30, FOUND FILTER DIRTY WITH BITS OF BROKEN PLASTIC, FOUND FWD SUPPLY FAN BLADES BROKEN. REMOVED AND REPLACED FWD SUPPLY FAN IAW AMM 21SDR UIEA2020050700954Display · malfunctionedNOTE - ACFT ATB TO IAH DUE TO: CAPT ADI WENT BLANK DURING CLIMB FOLLOWED BY AN ELECTRICAL BURNING ODOR. CAPT ND WAS INTERMITTENT ON CLIMB ALSO.(<P>A) REMOVED AND REPLACED EADI (CAPT) IAW AMM 31-20-00 - OPS TEST OK.</P><P>B) PERFORMED OPS TEST ON CAPT EHSI IAW SDR UIEA2020042700843Warning System · false activation"WXR WEAK" MESSAGE ON MFD.(<P>PERFORMED FIM BITE PROCEDURE PER 34-43 FAULT TREE 805. TEST PASSED.</P>)SDR UIEA2020042210807Control Valve · inoperativeRIGHT PACK TEMP CONTROL VALVE EICAS INDICATION INOPERATIVE. REMOVED AND REPLACED RT TEMP CNTL VALVE, OPS CHECK OK IAW AMM 21-51-04.SDR UIEA2020041680720Shutoff Valve · failedL ENG BLEED VALVE CAUTION WHEN CHANGING THRUST. REMOVED & REPLACED THE LT HPSOV IAW AMM 36-11-07. OPS CHECKED GOOD IAW 36-11-07.SDR UIEA2020041000733Unknown · malfunctionedWX AND TERR DO NOT DISPLAY ON F/O NAV DISPLAY(<P>PERFORMED OPS CHECK OF WEATHER RADAR SYSTEM ON FO SIDE IAW AMM 34-43-00. OPS CHECK GOOD. TEST OK.</P>)SDR UIEA2020040200677A/C Pack · noisyPACKS EXCESSIVELY LOUD DURING ALL PHASES OF FLIGHT. WORSE DURING THRUST CHANGES. OVER 80DB RECORDED IN CRUISE.(<P>PERFORMED OPS CHECK OF A/C PACKS IAW AMM 21-00-00. COULD NOT DUPLICATE DEFECT. </P><P>OSHA REQUIREMENTS ALLOW FOR 90 DB OF CONTINUOUS LOUDNESS FORSDR UIEA2020032000500A/C Pack · malfunctionedLEFT PACK INOP.(<P>TRANSFER TO MDDR 126021 IAW DDG 21-51-01-01, CAT C, DUE DATE 30-MAR-20. PLACARD INSTALLED.</P><P>LP 1071108: PERFORMED OPS CHECK OF LEFT PACK IAW B767 AMM 21-51-00. OPS CHECKS OK. NO FAULTS NOTED ON BITE CHECK/OPS CHECK. THIS CLEARS DMI 1260SDR UIEA2020031700459Unknown · malfunctionedWEATHER SYSTEM #1 DISPLAY WXR WEAK.(<P>PERFORMED OPERATIONAL TEST OF WEATHER RADAR SYSTEM IAW B767 AMM 34-43-00. NO DEFECTS NOTED AT THIS TIME.</P>)SDR UIEA2020022640316Warning Message · false activationWXR WEAK AMBER MESSAGE ON CAPT'S AND FO'S NAV DISPLAY ON LEFT RADAR SYSTEM.(<P>PERFORMED BITE TEST IAW FIM TASK 34-43 FAULT TREE 805. TEST OK.</P>)SDR UIEA2020022420302Charger · failedAPU INOP(<P>ATTEMPTED 3 STARTS. WILL NOT START. FOUND ECU FLAGS 34. THIS BECAME MDDR 124952 PER 49-11-01A CAT C, DUE 3MAR20. DISPATCH SP AT 08:45Z. MCC NOTIFIED. PLACARD INSTALLED.</P><P>LP 1071042, ITEM M3: REMOVED AND REPLACED APU BATTERY ASSY IAW AMM 24-31-SDR UIEA2020022420306Fan · failedSTATUS MSG: AFT EQ EXH FAN 2.(<P>T/S PER FIM 21-26, FAULT CLEARED. OPS CHECK GOOD. PER ATLAS MCC SWAP AFT EQ EXHAUST FANS 1 & 2. LP 1071043 - M4: PER MCC SWAPPED AFT EXH FANS 1 & 2 IAW AMM 21-58-41.</P><P>P/N OFF: 645890-1, S/N 1140; P/N ON: 645890-1, S/N 1142SDR UIEA202002210296Battery · dischargedAPU FAILED TO START.(<P>FOUND APU BATTERY LOW VOLT AT START 9VDC. REMOVE AND REPLACE APU BATTERY IAW AMM 24-31-04. OPS CHECK NORMAL AT THIS TIME.</P>)SDR UIEA2020013090140Unknown · unknownEXCESSIVE AIRFLOW WITH BOTH PACKS OPERATING. BOTH LT AND RT PACKS OPERATION WAS CHECKED. OPS CHECKED NORMAL IAW TASK 21-51-00/501.SDR UIEA2020012700130Radar · malfunctionedON CLIMBOUT IN VISIBLE PRECIPITATION, WXR FAIL MESSAGE DISPLAYED ON CAPT'S AND FO'S EHSI WITH LEFT RADAR SELECTED. SWITCHED TO RIGHT RADAR, NO FURTHER DEFECTS NOTED. PERFORMED TROUBLESHOOTING OF WXR LEFT AND RIGHT SYSTEMS. NO FAULTS NOTED AS PER FIM 34-43 FSDR UIEA2020012190097Warning Message · false activationAFT EQUIPMENT EXHAUST FAN 2 STATUS MESSAGE. TROUBLESHOT PER FIM 21-26 FT 806. MESSAGE ERASED. NO FURTHER FAULTS AT THIS TIME.SDR UIEA2020011800090Pressure Switch · failedDURING PRE-FLIGHT APU FAULT MESSAGE. APU AUTO SHUTDOWN. PERFORMED FIM 49-11 FT 995 LOW OIL PRESSURE ON BITE TEST, SUSPECTED BAD LOW PRESSURE SWITCH. REMOVED AND REPLACED SWITCH IAW AMM 49-94-02. OPERATIONAL TEST OK. PERFORMED FIM 49-11 FT 995, OIL WAS OVERSDR UIEA2020011700087Unknown · malfunctionedAPU FAILED ON GROUND TUG AND TAXI 3 TIMES IN 45 MINUTES. 3 STARTS SUCCESSFUL IN 1 HOUR. PERFORMED APU ECU BITE IAW FIM 49-11 FT 958. NO FAULTS NOTED. CLEARED MEMORY ON ECU. OPS CHECK NORMAL AT THIS TIME.SDR UIEA2020011700078Oil System · lowAPU FAILED TO START, LOW OIL. SERVICED APU TO LIMITS IAW 12-13-04. PERFORMED APU STARTUP, OPS CK GOOD.SDR UIEA2020011500071Wire · brokenRIGHT ENGINE BLEED LIGHT ON DURING PRE-DEPARTURE CHECK. FOUND BROKEN WIRE AT TERMINAL 2. REPAIRED IAW SWPM 20-10-13. PERFORMED AIR SUPPLY BITE TEST IAW AMM 36-23-00. NO MESSAGES NOTED.SDR UIEA2020010800038A/C Pack · noisyPACKS ARE TOO LOUD AND MAKE COMMUNICATION TOO DIFFICULT.(<P>PERFORMED OPS TEST OF OF BOTH L/H AND R/H PACKS. OPS TEST GOOD IAW B 767 AMM 21-51-00. PERFORMED BIT TEST OF TEMP CONTROLLER IAW B767 AMM 21-51-14. NO DEFECTS NOTED.</P>)SDR UIEA201912316173Warning Message · malfunctionedR ENG BLEED OFF EICAS, CYCLES ON AND OFF CONSTANTLY DURING FLIGHT WITH FLUCTUATING R BLEED DUCT PRESSURE.(<P>PERFORMED FIM 36-10 FT 838. NO DEFECTS NOTED WITH ENGINE RUN SYSTEM CHECKS OPS NORMAL, RH ENGINE.</P>)SDR UIEA2019122326121A/C Pack · nonePACKS ARE EXTREMELY LOUD AND SURGE SIGNIFICANTLY. ACCOMPLISHED AN OPERATIONAL TEST ON BOTH PACKS WITH ENGINE BLEED AND ALSO APU BLEED IAW AMM 21-51-00. OBSERVED NO SURGE OR LOUD NOISE WHILE RUNNING WITH APU BLEED. WHEN RUNNING PACKS WITH ENGINE BLEED, OBSERVSDR UIEA2019121986097A/C Pack · noisyIN FLIGHT WITH BOTH PACKS ON, THERE IS EXCESSIVE NOISE. WITH ONE PACK OFF, NOISE IS NORMAL. PERFORMED OPS TEST ON RT PACK WITH APU RUNNING IAW AMM 21-51-00.OPS CHECKED GOOD.SDR UIEA2019121876095Ignition Lead · failedAPU INOP. REMOVED AND REPLACED EXCITER IGNITION IAW AMM 49-41-03. OPS CHECKED GOOD. REMOVED AND REPLACED THE IGNITION LEAD ON APU IAW AMM 49-41-04. OPS CHECKED GOOD.SDR UIEA2019121306065Warning Message · false activationCABIN ALT AUTO 1 STATUS MESSAGE DISPLAYED.(<P>PERFORMED BITE TEST #1 CABIN PRESS CONTROL UNIT IAW FIM 21-31 FT 809, TEST OK.</P>)SDR UIEA2019121216052Housing · damagedITEM 1: EICAS MSG RH ENG FUEL FILTER CLIMBING THROUGH 10,000, N1 106.4. CLEARED WHEN THRUST REDUCED FOR CRUISE. NO ENGINE ABNORMALITIES NOTED. ITEM 2: STATUS MSG RH ENG FUEL FILTER SDR UIEA2019120215968Warning Light · false activationWEATHER RADAR WEAK MESSAGE FLASHING ON CAPTAIN'S LOWER DISPLAY DURING CLIMB OUT PERFORMED OPS TEST OF THE WEATHER RADAR SYSTEM, FOUND NO FAULTS AT THIS TIME. OPS CHECK GOOD IAW AMM 34-43-00SDR UIEA2019111205878Oxygen Mask · inoperativeCAPTAIN'S OXYGEN MASK DOES NOT STOP FLOW OF OXYGEN WHEN IN USE.(<P>SWAPPED LEFT SUPERNUMERARY SEAT MASK (OFF PART: P/N MC10-08-114, S/N B119143) WITH CAPTAIN MASK (OFF PART: P/N MC10-08-109, S/N SE63145) IAW B767 AMM 35-11-51. TRANSFERRED LEFT SUPERNUMERARY SESDR UIEA2019111005877Bulb · inoperativeBOTH GEN DRIVE LIGHTS ILLUMINATED IN BRIGHT MODE.(<P>FOUND INCORRECT LIGHT BULBS IN BOTH GEN DRIVE DISC SWITCHES. RELAMPED BOTH SWITCHES IAW AMM 33-16-02. PERFORMED BITE TEST AND RESET TEST OF BPCU IAW AMM 24-11-00-745-001. NO FAULTS OR DEFECTS NOTED AT THIS TSDR UIEA2019110405850Transceiver · malfunctionedWX RADAR DOES NOT PAINT VISIBLE BUILD UPS. DISPLAYS ONLY PAINTS SPLATTER PATTERN, FAILS TO ADVISE CREW OF PRECIPITATION. (<P>RERACKED LEFT R/T. PERFORMED OPERATIONAL TEST OF LEFT AND RIGHT WEATHER RADAR IAW AMM 34-43-00, SELF TEST AND OPS TEST GOOD.</P>)SDR UIEA2019101105693Generator · failedAPU POWER DID NOT AUTO TRANSFER UPON ENGINE SHUTDOWN. APU POWER DID NOT TRANSFER FROM GPU TO APU. REMOVED AND REPLACED APU GENERATOR IAW AMM 24-21-01, AND TESTED IAW AMM 24-21-01/501. FOUND GOOD, OPS CHECK NORMAL.
Back to Boeing 767-31B