SDR UALA2011100505369Cylinder · reads low46 MAN LIFE RAFT OUTBOARD PRESSURE BOTTLE READS 2900 PSI. REMOVED & REPLACED LIFE RAFT IAW MM 35-62-98.SDR UALA2011100505405Control Panel · malfunctionedHEADING SELECT BUTTON ON MAIN CONTROL PANEL INTERMITTENT. REPLACED AFCS MODE CONTROL PANEL PER MM. AIRCRAFT RETURNED TO CAT III STATUS PER MM.SDR UALA2011100505398Computer · failedASA SHOWS NO LAND 3 RESET AND TEST DOES NOT HELP. MCDP SHOW "FCC CENTER FAIL ", RESET CB'S NO HELP. REPLACED FCC-C PER AMM AND ACCOMPLISHED AFDS SYS TEST PER AMM. CHECKS OKAY, ACFT RTN'D TO CAT-III STATUS.SDR UALA2011100305359Computer · malfunctionedICE DETECTION OFF EICAS MESSAGE. SYSTEM NOT INSTALLED IN AIRCRAFT. REPLACED LEFT EICAS COMPUTER PER MM AND LOADED DATA, CHECKED OKAY.SDR UALA2011100305358Oxygen Mask · brokenFIRST OBSERVERS O2 MASK BROKEN. REPLACED MASK ASSY.SDR UALA2011100305357Shutoff Valve · faultyLEFT ENGINE HPSOV EICAS MESSAGE. COMPLIED WITH MEL CARD, HIGH PRESSURE VALVE DEACTIVATED. REPLACED VALVE, OP CHECKED GOOD. RAN ENG PER JRH 2-6-4. BLEED SYS CHECKED NORMAL. NO MESSAGE. OP CHECKED NORMAL.SDR UALA2011100305350Light · unsecureEMERGENCY EXIT LIGHT FELL OFF SEAT 6H. REPLACED LIGHT. OPS CHECKED OKAY.SDR UALA2011100505381Circuit Card · faultyRIGHT ENGINE HIGH PRESSURE SHUTOFF VALVE EICAS MESSAGE ILLUMINATED AT TOP OF DESCENT POWER REDUCTION. HPSOV LOCKED IN CLOSED POSITION PER MEL. REPLACED AIR SUPPLY CONTROL CARD PER MM, OPS TESTED GOOD.SDR UALA2011100505399Display · failedTOP EICAS BECAME BLURRY AND UNREADABLE AT 1000FT ON LANDING. CAME BACK, ON TAXI IN. REPLACED UNIT, CHECKED OKAY.SDR UALA2011100305347Skin · puncturedRIGHT INBD MAIN FLAP UPPER SURFACE HAS SMALL PUNCTURE. LOCATED 32 INCHES FROM INBD END & 3.5 INCHES FWD OF T/E. REPAIRED PER SRM. RESTORED FINISH.SDR UALA2011100305346Pin · brokenSEAT 1H FWD EMERGENCY EXIT PATH LIGHT INOPERATIVE. FOUND PIN BROKEN. REPLACED PIN & OPS CHECKED GOOD.SDR UALA2011100305360Circuit Card · failedAFTER EXTERNAL POWER PULLED, "EICAS SCC" STATUS MESSAGE DISPLAYED AND WILL NOT ERASE. REPLACED EICAS SCC CARD PER MM.SDR UALA2011100305356Coupling · tornFOUND WATER POURING OUT OF DRAIN BILGE PORT JUST FORWARD OF WASTE SERVICE PANEL. FOUND DRAIN COUPLING ASSY TORN. REPAIRED DRAIN COUPLING, LEAK CHECKED GOOD.SDR UALA2011093005309Heat Shield · cokedNR 2 PYLON, HEAVY COKING AROUND INBD LOWER PYLON HEAT SHIELD AREA. REMOVED CLOG FROM AFT PYLON DRAIN TUBE OUTLET.SDR UALA2011093005306Window · scratchedCAPTAIN'S NR 1 WINDOW IS SCRATCHED AND IS UNSERVICEABLE. VISIBILITY AFFECTED. REMOVED & INSTALLED WINDOW PER MM.SDR UALA2011093005299Lamp · brokenSEAT 1B BOTTOM SIDE AFT EMERGENCY LIGHT ASSY BROKEN. REPLACED LAMP AT 1AB.SDR UALA2011100505401Servo Valve · failedNO INFC FCC L RUD SERVO CMD, FAULT DURING ADFS TEST. REPLACED LEFT RUDDER ELECTRO HYDRAULIC SERVO VALVE, OPS CHECK OKAY. ACCOMPLISHED CAT III CHECK. ALL OK PER LAX MM. RETURNED AC BACK TO CAT III STATUS.SDR UALA2011100505400Computer · failedLEFT YAW DAMPER INOPERATIVE. COMPLIED WITH MEL CARD AND LEAK CHECKED. FOUND LEFT FCC COMPUTER FAILURE THE CAUSE. REPLACED LEFT FCC PER AMM. OPS CHECKED MCDP GROUND TEST MODE 01 FCC LEFT NORMAL, AND TEST OF YAW DAMPER SYSTEM PER AMM TESTED NORMAL.SDR UALA2011093005304Blade · nickedNR 1 ENGINE HAS 2 BLADES NICKED. BLENDED BLADES.SDR UALA2011092905280Blade · crackedDURING HFEC INSPECTION FOUND CRACK IN THE MIDSPAN SHROUD ON BLADE NR 1 AND NR 3 IN NR 1 ENGINE. REPLACED NR 1 ENGINE FAN BLADES NR 1 & 19 NR 3 & 21.SDR UALA2011092905277Light · brokenSEAT 5HJ SEAT AFT EMERGENCY LIGHT BROKEN OFF. REPLACED LIGHT ASSY, OPS CHECKED GOOD.SDR UALA2011092905279Actuator · leakingON ARRIVAL FOUND EVIDENCE OF HYDRAULIC LEAKING LEFT SIDE FUSELAGE BY APU. FURTHER INVESTIGATION SHOWED FLUID COMING FROM LOWER RUDDER AFT TRAILING EDGE DRAIN HOLE. FOUND UPPER RUDDER PCU PISTON SEAL LEAK POINT SEAPING UNDER 5 DROPS PER MINUTE AND CYCLE.SDR UALA2011092805238Light · tornTHE 6H AISLE SIDE 1 EMERGENCY LIGHT TORN OFF. REPLACED EMERGENCY LIGHT ASSY, OPS GOOD.SDR UALA2011092905288Controller · faultyLEFT BLEED DID NOT OPEN AFTER START. CYCLED & PULLED S11 PER SAMC W- NO SUCCESS. REPLACED PRESSURE REGULATOR VALVE CONTROLLER FOR LEFT ENGINE. RAN ENGINE CHECKS OKAY PER MM.SDR UALA2011092905289Shutoff Valve · faultyFLT CREW REPORTING NO RT ENG BLEED PRESSURE. REF DF322 FOR HPSOV NO BLEED PRESSURE WHEN THROTTLING UP AT ALL. CYCLING OVERHEAD SWITCH NO HELP, CB CYCLE NO HELP FOR PRV. DEFER ITEM ON DF0322 TO INOP THE PRSOV PER MEL 3611BB. REMOVED AND REPLACED PRESS REG VASDR UALA2011092805254Light · missingSEAT MOUNTED EMERGENCY PATH LIGHTS ONE EA MISSING FROM THE FOLLOWING SEATS 1B, 6H AND 4H. REPLACED EMERGENCY LIGHT ASSEMBLIES.SDR UALA2011092805266Floorboard · unsecureFLOORBEAM 1R SQUEAKS. UPON TROUBLE SHOOTING OF CAUSE, FROM E&E COMPT, FOUND NUMEROUS FLOORBOARD FASTENERS NOT SECURED WITH NUTS AND WASHERS MISSING ALONGSIDE P37 CB PANEL OUTBOARD TOP SIDE. YOU'LL HAVE TO INSPECT FWD AND AFT SIDE FOR ADDITIONAL CHECK TO CONFISDR UALA2011092805237Light · tornTHE 3H AISLE SIDE 1 EMERGENCY LIGHT TORN OFF. REPLACED SEAT MOUNTED EMERGENCY LIGHT.SDR UALA2011092805246Lamp · inoperativeLEFT SQUIB TEST INOPERATIVE. RELAMPED AND CYCLED SWITCH, TEST NORMAL.SDR UALA2011092805267Battery · faultyMAIN BATT CHARGER STATUS MSG. REPLACED MAIN BATTERY. REPLACED MAIN BATTERY CHARGER, MSG CLEARED.SDR UALA2011092805262Computer · faultyAUTOPILOT MOVES YOKE BACK AND FORTH INSIDE THE MARKER APP 1 INCH EACH WAY. REPLACED CENTER FCC AND RESTORED SYSTEM OPERATIONS.SDR UALA2011092805261Light · inoperativeBACKLIGHT IN FLAP INDICATOR INOPERATIVE. REPLACED FLAP TRANSMITTER. OPS NORMAL.SDR UALA2011092605191Control Panel · faultyWX RADAR FAIL ANTENNA MESSAGE DISPLAYED ACCOMPLISHED WIRING CHECK FROM WX TRANSCEIVER TO PLANNER ASSY ALL CHECKS GOOD, REPLACED WX RADAR CONTROL PANEL M75, WX RADAR ASSY INCLUDING FLAT PLATE ANTENNA AND MOUNT M269, OPS CHECKED NORMAL ON THE GROUND.SDR UALA2011092805242Connector · damagedEMERGENCY LIGHTS LEFT SIDE AISLE ARE ON. CYCLING SWITCH DOES NOT HELP, AT SEAT 12A. REPLACED SMALL DAMAGED CONNECTOR NEAR SIDE PANEL GRILL. TESTED OKAY.SDR UALA2011092605202Actuator · out of adjustAFTER ACCOMPLISHMENT MM 27-00-97 PG 607 WITH RIG PIN R4 INSTALLED, RUDDER TRAILING EDGE WILL NOT CENTER TO INDEX PLATE. OFF 7-8TH OF A INCH TO THE RIGHT. ADJUSTED RUDDER PCU PER MM. ADJUSTED RUDDER PCA PER MM. ADJUSTED RUDDER PCA PER MM. ADJUSTED RUDDER RSDR UALA2011092605203Indicator · faultyRUDDER TRIM FAILED TO TRIM IN EITHER DIRECTION. CHECKED RUDDER TRIM AND FOUND ACTUATOR WKG OK, RUDDER TRIM POS INDICATION INOP. EICAS RUDDER TRIM POS OK. INOPED RUDDER TRIM POS INDICATION PER MEL. REPLACED RUDDER TRIM INDICATOR PER MM. OPS CHECKED OK.SDR UALA2011092605200Oxygen Mask · no testF/O'S O2 MASK TEST SWITCH STICKS IN TEST POSITION. REPLACED O2 MASK BOX PER MM.SDR UALA2011092605167Microphone · damagedCAPTAINS O2 MASK WIRES PULLED OUT NO MICROPHONE. REPLACED CAPTAIN'S O2 MASK STOWAGE BOX. COMM CHECKED OK, O2 CHECKED OK.SDR UALA2011092305153Motor · faultyALT INBOARD SLAT POWER CB TRIPPED. OPS CHECKED PER MM AFTER RT INBD ELECTRICAL SLAT MOTOR REPLACED.SDR UALA2011092305141Fan · faultyEICAS MESSAGE: LEFT RECIRCULATION FAN' DISPLAYED & 'LEFT RECIRCULATION FAN INOPERATIVE' LIGHT ILLUMINATED, WITH SWITCH 'ON'. LEFT RECIRCULATION FAN LIGHT PRECEEDED BY ODOR OF SMOKE THROUGHOUT AIRPLANE. CONFIRMED THAT ODOR DISSIPATED AND CLEARED AFTER LEFT RSDR UALA2011092305147Heat Shield · brokenNR 2 ENG OIL TANK HEAT SHIELD BROKEN IN HALF, NEEDS TO BE REPLACED. REPLACED OIL TANK HEAT SHIELD.SDR UALA2011092305138Pcu · out of adjustRUDDER TRIM NEEDS 3.5 UNITS LEFT IN LEVEL CRUISE FLT. ADJUSTED RUDDER PCU PER MM.SDR UALA2011092205120Cover · looseSEAT 5B EMERGENCY LIGHT COVER LOOSE. SECURED EMERGENCY LIGHT COVER.SDR UALA2011092205119Light · looseEXIT PATH LIGHT LOOSE AT 6H. SECURED THE LIGHT ASSY AT 6H.SDR UALA2011092105109Engine · surgesNR 2 ENGINE HAS PERFORMANCE PARAMETER SHIFT. RIGHT ENGINE CONDITION MONITORING (ECM) DETECTED A SURGE ON ROLL OUT, THIS IS A RING CASE ENGINE, VISUALLY CHECK INLET & EXHAUST, 2.5 BLEED AND 2.9 BLEED OPENINGS FOR DAMAGE OR UNUSUAL MATERIAL, CHECK IP CHECK VALVSDR UALA2011092205125Handset · inoperativeDOOR INTERCOM DOES NOT WORK TO AFT CABIN OR COCKPIT. REPLACED HANDSET AND SYSTEM OPS CHECKED OK.SDR UALA2011092105100Window · defectiveF/O'S WINDSHIELD 1R WINDOW HEAT TERMINAL BLOCK J4 AND J5 ARE LOOSE. FOUND ON LINE COA 618423, WINDSHIELD TERMINAL BLOCKS CHECK. MAINT TEXT: ON PANEL P37 WINDOW HEAT 1R CB PULLED FOR WINDOW CHANGE. P37 CB F4 PULLED. REMOVED WINDOW. RESET CB, OP CHECKS GOODSDR UALA2011092205118Light · brokenONE SEAT MOUNTED EMERGENCY LIGHT BROKEN OFF AT SEAT 1B. TAPED OFF AND STOWED WIRE ENDS. REPLACED EMERGENCY LIGHT ASSY AT 1B.SDR UALA2011092205116Light · brokenSEAT 1H FWD EEL BROKEN OFF. REPLACED SEAT 1H FWD EEL ASSY, OPS CHECKS OK.SDR UALA2011092105111Terminal Block · looseDURING ACP OF COA 618423 FOUND LOOSE TERMINAL BLOCK J5, WINDOW IS OUT. NR 1 LEFT WINDSHIELD REPLACED.
Back to Boeing 767-322