Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010112204308Fan · faulty"FWD EQ EXH FAN" MSG DISPLAYED. CANNOT GET STATUS MSG TO CLEAR. REPLACED FAN, OPS NORMAL.SDR HALA2010112000551Generator · faultyETOPS SIGNIFICANT SYSTEM - APU SHUTDOWN AT GATE. PERFORMED APU BITE. NO FAULTS NOTED. RESTARTED APU -
COULD NOT GET GENERATOR ONLINE. REPLACED APU GCU PER AMM 24-22-02. NO HELP. RE-INSTALLED ORGINAL APU GCU PER AMM 24-22-02. REPLACED APU GENERATOR PERSDR UALA2010111804268Anti-Ice Valve · failedLEFT ENGINE ANTI-ICE VALVE LIGHT ON WITH SWITCH ON AND BLEED SWITCH OFF. LEFT ENG ANTI-ICE VALVE FAIL TO OPEN WITH ENG BLEED OFF. PER OFF GATE DEICING. DEFER IN THE LOCKED OPEN POSITION. REF MEL CARD 30065. SECURED HPSOV IN CLOSED POSITION. REPLACED LEFTSDR UALA2010111804272Feeder Cable · damagedEMERGENCY LIGHT ON SEAT 33A IS INOP. REPLACED SEAT CABLE. CHECKS GOOD.SDR UALA2010111804271Actuator · faultyAPU DOOR EICAS MESSAGE DISPLAYED ON GROUND. NOT RESETABLE. SEVERAL DOOR FUNCTION PERF AND ECU RESET, NO HELP. BITE CHK EICAS FOR MSG'S. REPLACED INLET DOOR ACTUATOR. OPS CHECKS GOOD.SDR UALA2010111704261O-Ring · leakingLEFT WING INBOARD AILERON INBOARD POWER CONTROL ACTUATOR LEAKING HYD FLUID AT PRESSURE LINE UNION. REPLACED O-RING. PCA OP'S CHECK NORMAL AND NO LEAKS. CLEANED AS MUCH AS POSSIBLE HYD FLUID. MAY HAVE RESIDUAL FLUID AT NEXT LEG.SDR UALA2010111704262Actuator · faultyTEMP UNCONTROLLABLE ALL CABINS AND CP. ALL TEMP CONTROLS FULL COLD OR BOTH PACKS STB C TEMPS 75. ZONE TEMP BITE OK. FOUND RT PACK RAM AIR EXHAUST DOOR ACTUATOR INOP. DOOR MOVES BY ITSELF. A ACTUATOR NO STOCK FRA. REMOVED EXHAUST DOOR PER CDL. DOOR AND ACSDR UALA2010111604243Generator · faultyAPU GENERATOR FAILED AT DEPARTURE. REPLACED GENERATOR AND GCU, OP CHECKS NORMAL.SDR UALA2010111804263Battery Pack · inoperativeEXTERIOR EMERGENCY LITES AFT OF RT WING WHICH OPERATE VIA M733 EMERGENCY LIGHTS BATTERY PACK DO NOT ILLUMINATE WHEN TESTED. REPLACED AND OPS CHECKED THE M733 EMERGENCY LIGHT BATTERY ASSEMBLY PER MM. INSPECTED BY QC STAMP NR 822. OPS CHECKED GOOD. PEMCO NR SDR UALA2010111704255Battery Pack · inoperativeEMERGENCY CEILING LIGHTS ON THE LEFT SIDE ROWS 19JK THRU 22JK AND EMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK M1209 DO NOT OPERATE. REPLACED EMERGENCY LIGHT BATTERY PACK AT M1209 POWER SUPPLY PER MM. OPS CHECKS GOOD.SDR UALA2010111604242Light · missingEMERGENCY LIGHTS MISSING SEATS 1H, 5H. REPLACED EMERGENCY LIGHTS SEATS 1H, 5H, CHECKED GOOD.SDR UALA2010111604240Floorbeam · crackedBS 770, MID GALLEY FLOOR CENTER RIGHT TRANSITION FLOORBEAM CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED TRANSITION BEAM IAW SRM, LOCATED, DRILLED AND DEBURRED NEW BEAM P/N STA 770 MID GALLEY FLOOR. INSTALLED NEW FLOORBEAM IAW SRM.SDR UALA2010111504230Oven · smokeWARMING OVEN NR W13 SMOKES AND SMELLS. REPLACED WARMING OVEN R13. OPS NORMAL.SDR UALA2010111504206Spring · faultyL1 DOOR DISARMED ALL BY ITSELF DURING LANDING. FLT ATTENDANT STATED THAT SHE FOUND DOOR DISARMED WHEN DUTIES CALLED FOR DIS-ARMING AT ARRIVAL. INSPECTED ARM-DISARM OVERCENTER SPRING, VERY GOOD.SDR UALA2010111504207Battery Pack · inoperativeEMERGENCY LIGHT INOP FWD OF DR2L. REPLACED BATTERY PACK, CHECKS GOOD.SDR UALA2010111504202Bushing · missingLEFT OVERWING BSLIDE DOOR DEPLOY CABLE IS MISSING SPACER, BUSHING ON THE FWD LOWER PULLEY. SUPPLEMENTAL DATA UPDATE, INSTALLED BUSHING INTO OVERWING SLIDE DOOR DEPLOY CABLE LOWER FWD PULLEY. OPS CHECKS GOOD.SDR UALA2010111504201Light · malfunctionedEXIT PATH LIGHTING ON RIGHT SIDE OF COACH ILLUMINATED. ACCOMPLISHED A TEST OF THE EMERGENCY LIGHTS, OPS CHECKED NORMAL ON GROUND.SDR UALA2010111204190Relay · faultyON POWER UP - EICAS MESSAGES EQUIPMENT COOLING AFT FAN - CARGO FIRE DET FAN - BATTERY CHARGER AND HYD QTY DISPLAYED - NO HYD QTY INDICATIONS. ACCOMPLISHED WIRING CHECKS PER WD 24-51-52 PG1A SHT 1 FOUND NO POWER ON K102 PIN A2 WHEN APU OR EXTERNAL CONNECTED ANSDR UALA2010111104188Sensor · faultyL/E SLAT ASSY DISAGREE, RTFL. FOUND NR 4 LE SLAT SENSOR S285 FAULTED DURING PROX BOX BITE. PRIOR TO SENSOR REPLACEMENT FOUND WIRE LENGTH OF W430-04TB-20 AND W430-04TR-20 TOO SHORT TO SPLICE IN NEW SENSOR. LENGTHENED WIRES BY REPOSITIONING 25577 SHIELD TERMINSDR UALA2010111204189Switch · faultyCENTER RT FUEL PUMP PRESS LIGHT NOT ON BEFORE ENG START WITH SWITCH ON. SWITCH FOUND FAULTY. REPLACED CTR RT PUMP LOW PRESSURE SWITCH. OPS NORMAL.SDR UALA2010111004170O-Ring · leakingCTR HYD LEAK, FLIGHT DIVERTED. CENTER HYD QTY DROPPING TO .49. REFILL EICAS CENTER HYD SYS TURNED OFF. LEAKING O-RING ON RT CENTER HYDRAULIC ACCMP WAS CHANGED.SDR UALA2010111004174Power Supply · faultyFLOOR EXIT LIGHTS INTERMITTENT AT DOOR 2L & LAV AREA 112. REPLACED POWER SUPPLY M1561 AT 38A AND M732 AT 23J. OPS CHECKED OKAY.SDR UALA2010110804147Bulkhead · damagedLEFT SIDE COAX FEED THRU AT AFT PRESSURE BULKHEAD WAS LEAKING. SEALANT PR1458-B2 APPLIED TO AREA. NO FURTHER LEAKS.SDR UALA2010110804132Light · brokenSEAT 4H EEL LITE STRIP IS BROKEN. REPLACED SEAT 4H EEL LITE. OPS CKS OKAY.SDR UALA2010110804154B-Nut · leakingOIL LEAK NR 1 ENGINE AT B-NUT ON LARGE SUPPLY LINE AT FUEL OIL COOLER. SUPPLEMENTAL DATA UPDATE SECURED LINE. MOTORED NR 1 ENGINE, NO ACTIVE LEAKS NOTED AT THIS TIME.SDR UALA2010110804152Cover · out of toleranceRIGHT CTR PUMP PRESSURE LIGHT WON'T ILLUMINATE. LIGHT LENS COVERS INSTALLED. WHEN CLEARING DEFERRED REMOVE COVERS AND RETURN TO SPARE BULB CONTAINER. NOT A PUMP PROBLEM SUSPECT CENTER TANK RIGHT PUMP LOW PRESSURE LIGHT DOES NOT COME ON WITH FUEL PANEL CLOSED ASDR UALA2010110804153Battery · dischargedFOUND APU BATTERY UNDER VOLTAGE 13V. REPLACED BATTERY, OPS CHECK OKAY. APU STARTS NORMALSDR UALA2010110804123Circuit Card · unsecureR ENG FIRE LP 2 ON STATUS PAGE. RESEATED FIRE LOOP CARDS M683, M684, M689 AND M690 FOR RIGHT ENGINE INDICATION AND DETECTION. OPS OKAY PER MM.SDR UALA2010110904166Control Unit · malfunctionedSATCOM HIGH GAIN STATUS MSG WON'T CLEAR. BOTH HIGH AND LOW GAIN INOP. DEFERRED PER MEL. REPLACED PORT SATCOM BEAM STEERING UNIT. PERFORMED TEST PER MM. NORMAL OPERATION NOTED.SDR UALA2010110504104Actuator · leakingLT WING AFT OF PYLON SAIL TAIL AREA HAS EVIDENCE OF HYD LEAK. LEAK IS AT LT INBD AILERON INBD ACTUATOR ON ACT ROD SEAL. LEAK IS MEASURED AT 4 DROPS PER MIN. COMPLETED ACTUATOR REPLACEMENT.SDR UALA2010110504111Lamp · unsecureEMERGENCY LIGHT 6H FALLS OUT. SECURED LAMP, OPS CKD OK.SDR UALA2010110504110Shutoff Valve · inoperativeLEFT PACK WILL NOT STAY ON. SUPPLEMENTAL DATA UPDATE LEFT PACK INOP. SEVERAL PREV HITS, ACP CHK PER MM. CONFIRM WITH ONLINE IPC. RPL'D FLOW CONTROL CARD M863, NO HELP. RPL'D FCSOV. OPS CK NORMAL.SDR UALA2010110304089Light · brokenEMERGENCY LIGHT ON SIDE OF SEAT 17B BROKEN IN HALF. REPLACED EMERGENCY LIGHT. CHECKS GOOD.SDR UALA2010110304081Lamp · inoperativeFOUND COVE LIGHT AT SEAT 26 HJ INOP. REPLACED LAMP OPS. CHECKED GOOD.SDR UALA2010110304092Roller · obstructedSMOKE ODOR FROM MID CABIN TO AFT CABIN. RAN ALL ELECTRICAL SYSTEMS, GALLEY EQUIPMENT, PES SYSTEMS. NO OBVIOUS ODORS OR DEFECTS NOTED. F/O AND AMT NOTED THAT RAMP HAD A PALLET STUCK IN FWD CARGO DOORWAY AND DRIVE UNITS ROLLER WAS CREATING A "PUNGENT" ODOR.SDR UALA2010110304080Light · missingEMERGENCY STRIP LIGHT ON SIDE OF SEAT 6H MISSING. INSTALLED MISSING EMERGENCY LIGHT. OPS CHECK GOOD.SDR UALA2010110304088Strap · missingLIFE RAFT ON ROW 20AB MISSING TIE DOWN STRAP.SDR UALA2010110104037Torque Tube · wornLEFT AILERON BINDS DURING FLT CONTROL CHECK WITH FLAPS 5 AROUND 6 UNIT. FOUND BEARING ON LEFT LATERAL CONTROL ACTUATOR INPUT CRANK WORN AND RUSTED. REMOVED LT LATERAL CENTRAL INPUT CRANK TORQUE TUBE ASSEMBLY. NOTE: CABLE GUIDE REMOVED UPPER BRKT. HANGING ON CSDR UALA2010110104040Actuator · bypassingOPERATED HYD & TURNED CONTROL WHEEL LEFT, CAN FEEL SHUTTER, VIBRATION IN COCKPIT AIRFRAME, CONTROL WHEEL & FROM INBD AILERON TO OTBD AILERON WHILE IT STILL HELD IN LT TURN. ISOLATED TO CTR HYD SYS. NO VIB IN RT & LT HYD SYS ON. RT WING AILERON OK NO VIBS. ISDR UALA2010110104024Adc · faultyLEFT NAV SYS FAILURE, RTFL REPLACED NR 1 ADC IAW MM PROCEDURE, CHECKED OK.SDR UALA2010110104049Diplexer · malfunctionedSATCOM FAILED TWICE DURING CALLS. INITIALLY COMMS ESTABLISHED BRIEFLY AND THEN DROPPED. REPLACED M1791, DUE TO A LGA HPA VSWR FAULT. OPS CK OK.SDR UALA2010110104043Light · inoperativeEMERGENCY LIGHT INOP ON SEAT 5H AFT. REPLACED LIGHT ASSY, CHECKED NORMAL ON GROUND.SDR UALA2010102904007O-Ring · leakingNR 1 ENG STRUT DRAIN HAS FUEL LEAKING AT ENG SHUTDOWN. FOUND MAIN FUEL LINE COUPLING ABOVE NR 1 ENG FIREWALL IS LEAKING FUEL. DISASSEMBLED NR 1 ENG. FWD MOST FUEL LINE COUPLING INSIDE PYLON IMMEDIATELY ABOVE FIREWALL, FOUND WEAR DAMAGE ON LINE UNDER UPPER HALSDR UALA2010102904006Fire Warning · false activationEICAS MESSAGE "ENG 2 FIRE LP 2" DISPLAYED. (LT=1, RT=2). SHOOK OUT ENG WIRING, UNABLE TO DUPLICATE. REPLACED M684 FIRE DET CARD AS PRECAUTIONARY.SDR UALA2010102904015Wire · brokenSMALL PART CAME OFF ABOVE SEAT 6H. FOUND SEAT 6H AFT EMERGENCY LIGHT ON SIDE OF SEAT WIRES BROKEN. TAPED WIRES, TAPED LIGHT STRIP TO SEAT. ALL OTHER EMERGENCY LIGHTS CHECK OK.SDR UALA2010102803980Light · dislodgedSEAT 17HJ EMERGENCY LIGHT ATTACHED TO SEAT TORN OFF. TAPPED OVER AREA WHERE EMERGENCY LIGHT ATTACHES. REPLACED EMERGENCY LIGHT SEAT 17HJ.SDR UALA2010102804000Engine · cokedNR1 ENGINE HAS COAKING ON VSV AND COMPRESSOR CASE. REPLACED ENGINE.SDR UALA2010102904014Damper · faultyRT YAW DAMPER INOPERATIVE. ACCOMPLISHED YAW DAMPER SYS BITE. SYS TESTED NORMAL. STORED FLIGHT LEG FAULTS IN RT YAW DAMPER MODULE FAULTING RT YAW DAMPER ACTUATOR. LT YAW DAMPER MODULE HAS NO FAULTS.SDR UALA2010102904022Battery Pack · inoperativeEMERGENCY EXIT OVERHEAD LIGHT OUT ROW 32-39 LT SIDE. REPLACED BATTERY PACK, OPS CHECKS GOOD.SDR UALA2010102803999Cable · faultedRT HF RADIO FREQUENCY FAULTY. ANYTIME RT HF RADIO FRQ TUNED WILL CAUSE OVERSPEED MSG ON EADI AND AUTOTHROTTLE BACK TO IDLE, PER CREW. PER CREW, GOT MESSAGE AND THROTTLES WENT TO IDLE, BUT AUTOTHROTTLE DID NOT DISENGAGE. NO PROBLEM USING LEFT HF. FOUND OPE
Back to Boeing 767-322