What was found
RIGHT CTR PUMP PRESSURE LIGHT WON'T ILLUMINATE. LIGHT LENS COVERS INSTALLED. WHEN CLEARING DEFERRED REMOVE COVERS AND RETURN TO SPARE BULB CONTAINER. NOT A PUMP PROBLEM SUSPECT CENTER TANK RIGHT PUMP LOW PRESSURE LIGHT DOES NOT COME ON WITH FUEL PANEL CLOSED AND PUMP SWITCH ON AND ENGINES NOT RUNNING. ALSO LIGHT LENS COVERS WERE NOT INSTALLED. PUMP SWITCHES WERE TAPED INOP PER MEL. RESEATED SWITCH COVER AND RESET SYSTEM, OPS TESTED OK.