Boeing 767-322
Service difficulty reports · 11,768
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010040601156Line · leakingC HYD SYS PRESS ON UPPER EICAS. FLUID LEVEL IS .14. FOUND CTR HYD LINE ON LT MAIN GEAR TRUCK POSITIONER LEAKING. REPLACE HYD LINE AND ACCOMPLISH TEST IAW MM. OPS CKS OK.SDR UALA2010040601151Light · malfunctionedFLOOR EXIT PATH LIGHTS ON IN BACK THIRD OF AIRPLANE. PERFORMED EEL RESET TEST. EEL RESET AS NEEDED. NO DEFECTS NOTED.SDR UALA2010040601127Display · inoperativeLOWER EICAS SCREEN BLANK. LOWER EICAS DEFERRED. ACFT REROUTED NON-ETOPS TO HNL FOR PARTS REPLACEMENT. REPLACED LOWER EICAS SCREEN, OPS CHECKED OK.SDR UALA2010040601126Switch · improper partRAT SWITCH DOES NOT ENGAGE WHEN SELECTED. FOUND IMPROPER SWITCH INSTALLED ON THE CONTROL BOX. THIS CAUSED THE RAT SWITCH TO NOT 'LATCH' FLUSH WITH THE CONTROL BOX WHEN PRESSED. REMOVED SWITCH AND REPLACED WITH CORRECT SWITCH. OPS CHECKED RAT SWITCH. OPS CHESDR UALA2010040601124Connector · looseEEL LIGHT AT SEAT 33HJ INOPERATIVE. SECURED CONNECTOR, OPS CHECK OK.SDR UALA2010040601123Connector · unsecureEEL LIGHT AT SEAT 7A INOPERATIVE. SECURED CONNECTOR, CHECK OKAY.SDR UALA2010040501121Controller · failedLEFT ENG BLEED LGT & LT ENG HPSOV EICAS MSG WITH ENG BLEED SW ON, & ENG RUNNING. COMPONENT FOUND DEFECTIVE. REPLACED HPSOV AND HP CONTROLLER. ACP'D BLEED SHIFT THREE TIMES, NO HPSOV EICAS MSG OR ENG BLEED LIGHT.SDR UALA2010040501115Actuator · faultyRUDDER TRIM INOP, FLIGHT DIVERTED. ACTUATOR FOUND DEFECTIVE. REPLACED RUDDER TRIM ACTUATOR. ACCOMPLISHED RII INSPECTION OF RUDDER TRIM ACTUATOR INSTALLATION. VISUAL FLT CONTROL MOVEMENT CHKS ACCOMPLISHED. ALL OPS & INDICATIONS NORMAL.SDR UALA2010040501113Windshield · leakingA STRONG HISS NOISE COMES FROM THE CAPT UPPER LT CORNER IN THE FRONT WINDSHIELD. PRESSURIZED ON THE GROUND AND NOTED A MODERATE LEAK DEVELOPING AT CABIN 2.0 PSI. SUSPECT WINDSHIELD NEEDS REPLACED, REMOVED AND RESEALED. WINDSHIELD AVAIL SFO. REPLACED CAPTAINSDR UALA2010040501107Fitting · looseALT DISAGREE EICAS, RTFL. TROUBLESHOT SYS AND FOUND FITTINGS LOOSE ON F/O PITOT HEAD. SECURED FITTINGS. ACCOMPLISHED THE LOW RANGE AND HIGH RANGE LEAKAGE CHECK, SYS TESTS GOOD.SDR UALA2010040501106Sign · inoperativeFLIGHT DECK EMERGENCY EXIT LIGHT ILLUMINATES WITH POWER OFF AND EMERGENCY LIGHTS DISARMED. REPLACED SIGN, NO HELP. NO LIGHTS AT ALL. ON OR OFF. A PIECE CAME OFF OF MOUNT BASE. REPLACED MOUNT BASE AND LIGHT ASSY, OP CK OK.SDR UALA2010040201100Oxygen Mask · no testPASSENGER OXYGEN MASKS TEST DROP, ZONES A AND B CTR DID NOT DROP. REPACKED MASK. OPS CHECKS GOOD.SDR UALA2010040201096Light · faultyAFT GALLEY CROSS AISLE EMERGENCY LIGHT LEFT LIGHT IS INOP. PULLED UP CARPET TO EXPOSE EMERGENCY LIGHT CONNECTOR. TRIED ANOTHER EMERGENCY STRIP, NO HELP. NO POWER AT POWER FEEDER. REPLACED BAD POWER STRIP FROM SIDEWALL TO AFT MID LAV AREA AND REPLACED AFT GALLSDR UALA2010040101093Apu · inoperativeUNABLE TO START APU, RTFL. APU ALTITUDE NO START. APU ROTATES BUT NO EGT INDICATIONS DURING START. VERIFIED APU OIL IN SERVICE BAND AT SIGHT GAUGE. BITE CHECK FAULTS "HOT OIL TEMP". FOUND METAL ON GEARBOX CHIP DETECTOR. CLEANED DETECTOR. RAN APU AND GOT MORE SDR UALA2010033101078Pump · inoperativeADP INOP, REMOVE AND REPLACE ADP AND ASSOCIATED AIR MODULATING VALVE.SDR UALA2010033101079Warning System · activatedON GEAR RETRACTION C HYD DEM PUMP EICAS AND ASSOC OVERHEAD PSI LIGHT ILLUM, RAN FLT MAN SOP NO HELP.SDR UALA2010033001069Modulating Valve · faultyADP FAILURE, RTFL. ON GEAR RETRACTION C HYD DEM PUMP EICAS AND ASSOC OVHD PSI LIGHT ILLUM. RAN FLT MAN SOP, NO HELP. REMOVED AND REPLACED ADP AND ASSOCIATED AIR MODULATING VALVE.SDR UALA2010033001059Isolation Valve · faultyRT ISLN VALVE LIGHT ON WITH SWITCH IN OR OUT. VALVE DEEMED DEFECTIVE. REPLACED RIGHT ISOLATION VALVE. OPS ARE GOOD.SDR UALA2010032901044Wire · chafedOFF THE GATE RT GEN TRIPPED OFF, RESET RT GEN AND AGAIN TRIPPED OFF. FOUND YELLOW WIRE FOR IDG PMG CHAFED. NO DAMAGED WIRES. REPAIRED INSULATION. RAN ENG TWICE, GENERATOR OPS NORMAL.SDR UALA2010032901032Relay · inoperativeC ADP LOW PRESS LIGHT ILLUMINATED IN AUTO. EICAS MSG DISPLAYED C HYD DEM PUMP. ADP PRESS IS NORMAL. COMMENTS: C HYD DEM PUMP. FOUND ADP INOP IN AUTO AND ON MODE. TROUBLESHOT AND REPLACED K443 RELAY. OPS CHK OKAY.SDR UALA2010033001071Light · unsecureEEL STRIP INOP AT SEAT ROW 6AB. SECURED EEL STRIP.SDR UALA2010032901043Light · inoperativeEEL STRIP INOP AT SEAT ROW 3AB. SEAT ROW 6AB EEL STRIP ALSO INOP. SECURED EEL STRIP. REPLACED BOTH EEL LIGHTS. OP CHECKS ARE NORMAL.SDR UALA2010032901041Light · inoperativeEEL STRIP AT SEAT ROW 15HJ INOPERATIVE. REPLACED EEL STRIP, OPS CHECKED OKAY.SDR UALA2010032901040Power Strip · damagedAFT GALLEY RIGHT X-AISLE EEL STRIP INOP. REPAIRED DAMAGED POWER STRIP.SDR UALA2010032901031Attach Angle · damagedLEFT WING OTBD LWR LE PANEL AT WS 1022. LOWER ATTACH ANGLE, LOWER LOCK FASTENER INCORRECTLY INSTALLED WITH HOLE ELONGATED. REAMED HOLES, ACOMP DVI INSP AND ROTO-PROBE INSP. INSTALLED FREEZE PLUG, REPAIR CLIP AND REPAIR STRAP.SDR UALA2010032601025Nose Cowl · delaminatedNR 2 ENG NOSE COWL HAS AN AREA OF DELAMINATION AT 2 O'CLOCK POSITION, 24 INCHES BY 18 INCHES. REPLACED NOSE COWL.SDR UALA2010032601028Gyro · tumblesSTANDBY GYRO HAS TUMBLED, RTFL. REPLACED STANDBY ATTITUDE IND, GROUND CHECK NORMAL.SDR UALA2010032601015Light · inoperativeAFT GALLEY FLOOR EMERGENCY LIGHT STRIP INOPERATIVE. REPLACED EMERGENCY LIGHT STRIP, CHECK OK.SDR UALA2010032601014Light · inoperativeFWD EMERGENCY LIGHT STRIP AT SEAT 2H INOPERATIVE. REPLACED FWD EMERGENCY LIGHT STRIP, CHECKS OK.SDR UALA2010032601011Light · inoperativeMID GALLEY FLOOR EMERGENCY LIGHT STRIP INOPERATIVE. REPLACED LIGHT ASSY, CKS OK.SDR UALA2010032501004Accelerometer · faultyNR 2 ENG VIBRATION. ACP'D HIGH POWER RUN, ENG PARAMETERS: AT 1.40 EPR, VIB = L ENG 1.4, R ENG 2.0, AT 1.26 EPR L ENG 1.5, R ENG 3.1, AT 1.15 EPR L ENG 0.6, R ENG 1.4. ACP'D T ROUBLESHOOTING IAW FIM71-05-00, FIG 104, BLOCKS 1-8. NO DEFECTS FOUND. ACCOMPLISHEDSDR UALA2010032300994Wire · openAPU BITE MX MESSAGE DISPLAYED ON ECS PAGE. ECU BITE SHOW DEOIL SOLENOID CIRCUIT FAILED. WIRES RANG OPEN FROM ECU. REPLACED DE-OIL SOLENOID VALVE, NO HELP. FOUND WIRE OPEN BETWEEN D4024P PIN 5 AND DE-OIL SOL CONNECTOR P11 PIN 1. FOUND WIRE FROM PIN 5 D4024P TSDR UALA2010032300962Satcom · faultySATCOM STATUS ON LINK STATUS PAGE IS INOP. BOTH HIGH AND LOW GAIN FOR MOST OF FLIGHT. NO TIME TO TROUBLESHOOT. ACP'D FIM. REPLACED SDU AND RFU. ACP'D OP TEST PER MM. ACP'D VISUAL INSPECTION OF DIPLEX UNITS AND BSU FOR MOISTURE INTRUSION AND SECURITY. NO DEFECSDR UALA2010032200952Valve · malfunctionedRIGHT ENG BLEED OFF AND RT PACK OFF LIGHTS CAME ON DURING T/O ROLL AND STAYED ON THRU CLIMB AND L-O, THEN BLEED SHUTS OFF. DID BITE CHECK ON AIR SUPPLY BITE MODULE. HITS PRV AND WIRING. SWAPPED LT AND RT AIR SUPPLY CONTROL CARDS-NO HELP, RETURNED CARDS TO OSDR UALA2010032200946Transducer · misriggedFLAP SPLIT FSPM SHOWING A FAULT OF THE O/B SLAT PDU RVDT, RTBL.SDR UALA2010032200933Panel · leakingRT WING MID SEAM FWD OF PLATE 641FB IS LEAKING 24 INCHES IN 30 MINS, LOWER WING SURFACE. FUELED RT WING TO 33,000 LBS RT WING MID SEAM FWD OF PLATE 641FB IS LEAKING 24 INCHES IN 30 MINS. LOWER WING SURFACE. SEALED ON SMC24, FUELED AND LEAK CHECK GOODSDR UALA2010032200948Control Valve · faultyOFF THE GATE RT PACK WOULD NOT COME ON WITH ANY ENGS AIR, PER CREW. REPLACED FLOW CONTROL AND SHUTOFF VALVE IAW AMM. OPS CHECK NOW OKAY.SDR UALA2010032200936Light · brokenEEL LIGHTS FLASHING ON AND OFF IN FIRST CLASS. FOUND 1 SEAT MOUNTED LIGHT STRIP AT SEAT 1H HAS HALF OF STRIP BROKEN OFF. REMAINING PORTION OF STRIP OPERATES AND ALL OTHER LIGHTS OPERATE NORMALLY. REPLACED SEAT 1H FWD EMERGENCY PATH LIGHT ASSY, OPS NORMAL. SDR UALA2010032200928Floorbeam · corrodedFLOORBEAM UPPER CAP AT BS 347 RBL 29-50 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE RBL 29 TO 50 RBL, STA 347. HFEC INSP PER NDT PT6. VERIFIED DAMAGE REMOVED. INSTALLED REPAIR ANGLES, SHIMS AND STRAP REPAIR, REPAIR 4.SDR UALA2010032200927Floorbeam · corrodedMAIN CABIN STA 287 FLOORBEAM UPPER CAP HAS CORROSION O/B END, RBL 72. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION, HFEC INSP. VERIFIED DAMAGE REMOVED, AREA OF RPR 3.0 X 1.5 INCH. INSTALLED T-CHORD AND REPAIR ANGLES PER SRM.SDR UALA2010031900916Window · crazedR2 AND L2 WINDOWS VERTICALLY CRAZED TO THE POINT OF RESTRICTING VISIBILITY. REPLACED BOTH L2 & R2 SLIDING WINDOWS.SDR UALA2010031900915Transmitter · faultyHYD QTY READS ZERO, HYD QTY LIGHT ILLUM. EICAS MSG DISPLAYED (L,R,C) HYD QTY HYDRAULIC LOW PRESS LIGHT IS EXTINGUISHED. POS 1 (01=L,02=R,03=C). REPLACED HYD QTY IND PER MM. REPLACED HYD QTY MONITOR UNIT. OPS CHECK OKAY. SERVICED HYD LEFT SYSTEM.SDR UALA2010031900917Light · inoperativeRIGHT MAIN GEAR DOWN INDICATOR LIGHT INOP. REPLACED LIGHT ASSEMBLY. AS PRECAUTION PERFORMED PSEU LANDING GEAR SYSTEM NR 1 AND NR 2 AND SYSTEM TEST NORMAL.SDR UALA2010031900913Floorbeam · corrodedCABIN FLOOR BEAM LBL 23 STA 852 - 905 HAS CORROSION SEVERAL LOCATIONS. REMOVED CORROSION & EVAL FLOORBEAM REF SRM. FABRICATED & INSTALLED UPPER 'T' CHORD EXTRUSION AND SPLICE REPAIR AT FWD & AFT ENDS OF FLOORBEAM.SDR UALA2010031900912Floorbeam · puncturedCABIN FLOORBEAM PUNCTURED STA 1502 LBL 28. MAJOR REPAIR ACCOMPLISHED. TRIMMED OUT DAMAGE PER ST AEROSPACE EA 767-5365-13-A1932. ACP NDT OF DAMAGE CUT OUT & OPEN HOLES REF NTM 51-00-19 PT 6. NO DEFECTS FOUND. FABRICATED & INSTALLED DOUBLER REPAIR PER EA. SDR UALA2010031800905Oven · dirtyF/A'S SMELLED ELECTRICAL BURNING SMELL BUT NO SMOKE IN THE OVERWING JUMPSEAT AREA. PER SAM TURNED OFF THE F/A OVERWING READING LIGHTS. NO REOCCURRENCE OF SMELL. ALL MID GALLEY FLIGHT ATTENDANT READING LIGHTS AT MID GALLEY AREA TURNED ON FOR DURATION OF GROUSDR UALA2010031700894Window · crazedCAPTAIN'S FIXED SIDE-FORWARD WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS. REPLACE FIRST AVAILABLE. CREW COMMENTS: WITH CERTAIN LIGHT ANGLES WINDOW VISIBILITY REDUCED. CAPTAINS FIX SIDE FORWARD WINDOW VISIBILITY IS AFFECTED BY DEFECTS REPLACE OR REPAIR FIRSTSDR UALA2010031700893Window · crazedTHE 1ST OFFICER'S FIXED SIDE-AFT WINDOW'S VISIBILITY IS AFFECTED BY DEFECTS, REPLACE FIRST AVAILABLE. CREW COMMENTS: WITH CERTAIN ANGLES OF LIGHT WINDOW VISIBILITY REDUCED. THE 1ST OFFICERS FIX SIDE AFT WINDOW VISIBILITY AFFECTED REPLACE OR REPAIR FIRST MAISDR UALA2010031700892Valve · faultyFL390 DUCT PRESS SPLIT: L= 20 PSI, R= 45-50. REPLACED PRV ON LEFT ENGINE. GROUND RUN CHKS BOTH LEFT & RIGHT DUCT PRESSURES MATCHED APPROX 33PSI.SDR UALA2010031700891Trim System · malfunctionedRUDDER TRIM ISSUE. NO MOVEMENT OF RUDDER WITH RUDDER TRIM KNOB. AFTER TURNING, TRIM OPERATION RETURNED TO NORMAL. RUDDER TRIM FUNCTION CHECK ACCOMPLISHED. NO DEFECT NOTED. SAMC ADVISED NO ACTION REQUIRED. THE SAMC CONTROLLER AND MANAGER CONCURR THAT THE
Back to Boeing 767-322