Boeing 767-322
Service difficulty reports · 11,768
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009110903491Connector · unsecureEMERGENCY LIGHT AT SEAT 33HJ INOP. SECURED EEL CONNECTOR UNDER SEAT, CHECKS OKAY.SDR UALA2009110903490Light · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 1R INOP. REPLACED LAMP, OPS CHECKS GOOD.SDR UALA2009110903488Connector · unsecureEMERGENCY LIGHT AT SEAT 20AB INOP. SECURED EEL CONNECTOR, OPS OKAY.SDR UALA2009110903467Light · brokenEEL STRIP ON SEAT 22H BROKEN. REPLACED EEL LIGHT.SDR UALA2009110603462Engine · vibrationNR 2 ENG VIBRATION. NR 2 ENG EICAS VIB READS HIGH. HIGHEST READING 35 (X.X, RANGE 0.0 TO 5.0, ABNORMAL ON 767-322 IF ABOVE 4.0). EXCESSIVE VIBRATION NOT FELT IN AIRFRAME. 3.5 IS REACHED AT 1.11EPR. AT ALL OTHER EPR SETTINGS THE VIB IS LOWER. ACPD VISUAL INSDR UALA2009110603461Idg · malfunctionedCREW COMMENTS: RT ENG DRIVE LIGHT ON. RIGHT IDG LOW OIL PRESSURE. RIGHT ENGINE IDG REMOVED. REPLACED RIGHT ENGINE IDG. RAN ENGINE, SYSTEM CHECKS OKAY.SDR UALA2009110403425Fuel Tank · leakingUNWANTED FUEL XFER TO CTR TANK. 3 PREV HITS ALL SINCE TANK WAS ENTERED IN GSO OCT 11. REQ AT LEAST 3-4 SHIFTS FOR TANK ENTRY AT SMB. AT PUSH BACK CTR FUEL READ 0, AT LEVEL OFF WENT TO 1000 NR. LEAK CHECKS GOOD, TANKS AND FUEL PLATE FOR THE SLAT DRAIN ARE CLSDR UALA2009110403420Sensor · out of adjustLT WING SLIDE EICAS MSG, RTFL. FOUND SENSOR S218 ON LT OVERWING PACK DOOR LOOSE BUT APPEARED TO BE WITHIN TOLERANCE (0.10) BUT WITH MOVEMENT CAUSED EICAS MSG. REMOVED SHIM FROM SENSOR S218 FOR TROUBLESHOOTING, NO HELP. WILL NEED TO RE-GAP S-218. AFTER REMOVISDR UALA2009110403419Shutoff Valve · failedLEFT DUCT PRESSURE FLUCTUATES BETWEEN 25 TO 40 PSI ON DESCENT. FOUND PRSOV FAILED HEALTH CHECK. REPLACED PRSOV, OPS CHECKS GOOD.SDR UALA2009110403417Blade · bentNR 1 ENG BLADE 17 BENT ABOVE MIDSPAN SHROUD. REPLACED BLADES 17 AND 36 WITH A MATCH SET OF BLADES.SDR UALA2009110403416Blade · bentNR 1 ENG FAN BLADE 18 BENT ON LEADING EDGE ABOVE MIDSPAN SHROUD. SUPPLEMENTAL DATA UPDATE REPLACED BLADES 18 AND 37 WITH MATCH SET OF BLADES.SDR UALA2009110403415Shutoff Valve · malfunctionedEICAS "R ENG HPSOV". FOUND WIRE CHAFING ON HPSOV ACTUATOR ARM RT ENG. MAYBE CAUSING EICAS MESSAGE. REPLACED RIGHT ENGINE HPSOV. OPS OK, NO EICAS MSGS DISPLAYED.SDR UALA2009110403406Actuator · malfunctionedAILERON LOCKOUT EICAS MSG AND OVERHEAD ANNUNCIATOR LIGHT. REPLACED AILERON LOCKOUT ACTUATOR, CHECKS OKAY.SDR UALA2009103003395Light · missingEEL LIGHT MISSING AT 31AB. INSTALLED EEL LIGHT AND OPS CHECK GOOD.SDR UALA2009103003391Light · inoperativeEEL LIGHTS INOP AT SEAT 29H. REPLACED LIGHT ASSY AND OPS CHECK GOOD.SDR UALA2009103003390Light · inoperativeEEL LIGHTS INOP AT SEAT 36A. INSTALLED NEW LIGHT ASSY AND OPS CHECK GOOD.SDR UALA2009103003389Cable · faultyEEL LIGHTS INOP AT SEAT 34A. INSTALLED NEW CABLE ASSY AND OPS NOW NORMAL.SDR UALA2009103003388Light · inoperativeEEL LIGHTS INOP AT SEAT 17A. REPLACED EEL LIGHT AND OPS CHECK GOOD.SDR UALA2009102903382Connector · corrodedLT MAIN FQIS CONNECTOR M1944 ASSY IS CORRODED. INSTALLED NEW FQIS CONNECTOR M1944. OPS CHECKS GOOD. REF FUEL BITE.SDR UALA2009102803377Valve · malfunctionedRT PACK INOP AFTER ENGINE STARTED. CONTROLLER FAULTED LOW LIMIT VALVE. REPLACED LOW LIMIT VALVE. RAN ENG AND PACK CHECKS OKAY.SDR UALA2009102803367Stator · defectiveUPON LANDING GOT 'L ENG CONTROL' EICAS MESSAGE. EICAS DISAPPEARS AFTER TOUCH DOWN BUT SHOWS ON STATUS MSG. LEFT ENGINE PMA STATOR REPLACED ACC. ALL TEST PASSED.SDR UALA2009102803366Light · missingINTERIOR EMER AISLE LIGHT AT SEAT 6AB MISSING, AFT POSITION. REPLACED LIGHT ASSY. OPS CHECKED OKAY.SDR UALA2009102803365Light · inoperativeEXTERIOR EMER LIGHT AT FUSELAGE AFT OF LT TRAILING EDGE INOP. RELAMPED, OPS CHECKED OKAY.SDR UALA2009102803364Light · inoperativeEXTERIOR EMER LIGHT FWD LT DR GRD ILLUM LIGHT INOP. CLEANED ASSY CONTACTS AND REPLACED LAMP. CHECKED OKAY.SDR UALA2009102703358Light · missingINTERIOR EMER AISLE LIGHT AT SEAT 6AB MISSING, AFT POSITION. REPLACED LIGHT ASSY. OPS CHECKED, OKAY.SDR UALA2009102703352Adc · activatedRECEIVED "ALT DISAGREE" MSG, RTFL. REPLACED NR 2 AIR DATA COMPUTER - ACCOMPLISHED ALTIMETER ACCURACY CHECK OF CAPTS - F/O - STBY ALTIMETERS. ALTITUDE READOUT WITHIN LIMITS PLUS-MINUS 40 FT ON ALL 3 SYSTEMS AT 5000-10000-20000-40000 FT OF ALTITUDE. NO PITOT SDR UALA2009102703357Light · missingEEL STRIPS MISSING AT SEAT 2H AND 2J. REPLACED STRIPS.SDR UALA2009102703345Sealant · damagedFUEL LEAK FROM L PACK BAY AT 20DPM. CENTER FUEL TANK UNDER PANEL 193PL LT WING TO BODY FAIRING STATION 955.10 REAR SPAR CENTER TANK FASTENERS LEAKING. FOUND LEAK AT AFT SPAR BELOW AND JUST FWD OF LOWER LEFT BATHTUB FITTING. FOUND INTERNAL LEAK, REMOVED DAMASDR UALA2009102703362Intercostal · damagedCABIN FLOOR PANEL SUPPORT INTERCOSTAL NUT INSERTS PULLED THRU AT STATION 1087 APPROX ROW 23. INTERCOSTAL REPAIRED AT C CHECK ON WU Z3461N. FLOOR PANEL REPLACED AT C CHECK ON WU Z3460N.SDR UALA2009102703360Fire Loop · failedEICAS MSG "ENG2 FIRE LP2" DISPLAYED. REPLACED LOWER FORWARD FIRE LOOP, OPS CHECKED OKAY.SDR UALA2009102703356Light · brokenREPLACED EEL LAMP ASSY. EEL OPS CHECKS OKAY. REPLACED EEL LAMP ASSY. EEL OPS CHECKS OKAY.SDR UALA2009102703354Idg · malfunctionedEICAS MSG R GEN DRIVE DISPLAYED. GEN DRIVE LIGHT ILLUM. GEN DRIVE DISCONNECTED. REPLACED RT ENG IDG. NO LEAKS DETECTED. IDG OPERATIONAL TEST IS GOOD.SDR UALA2009102603328Power Supply · faultyAFT GALLEY EMERGENCY FLOOR LIGHTING AS WELL AS DOOR 2R EXIT LIGHTING FLASHING. EXAMINED WIRING AT SPLICE SM45, CONNECTOR D13244 AND D5086, NO DEFECTS NOTED. REPLACED POWER SUPPLY M1556.SDR UALA2009102603327Power Supply · faultyEMERGENCY EXIT LIGHTS COMING ON AND OFF IN ECONOMY. FLOOR LIGHTS AS WELL AS EXIT LIGHT AT 2L. EXAMINED WIRING AT SPLICE SM23, CONNECTOR D13210, AND D5084 NO DEFECTS NOTED REPLACED PWR SUPPLY M1561.SDR UALA2009102703359Sensor · faultyLEFT PACK TEMP EICAS ON FINAL APPROACH. PERFORMED BITE ON LEFT PACK CONTROLLER. HAD RAM INLET ACT FAULT ON BITE AND PACK SENSOR FAULT ON PREVIOUS FLIGHT. ACT HAS BEEN REPLACED 2X. REPLACED PACK TEMP SENSOR. REPLACED RIGHT AND LEFT TEMP CONTROLLERS, OPS CHESDR UALA2009102303321Selector Knob · jammedCABIN PRESS LDG ALT SELECTOR KNOB JAMMED. REPLACED CABIN PRESS SELECTOR PANEL.SDR UALA2009102303306Actuator · inoperativeCABIN PRESSURE SELECTOR PANEL MANUAL MODE FAILED TEST. REPLACED CABIN PRESSURE OUTFLOW VALVE ACTUATOR. OPS CHECKED NORMAL.SDR UALA2009102603326Gasper Fan · overheatedELECTRICAL BURNING ODOR AT MIDDLE GALLEY AREA. CHECKED MIDDLE GALLEY AREA ABOVE CEILING AND NOTHING ABNORMAL FOUND. NOTICED GASPER FAN MOTOR VERY HOT. DEACTIVATED GASPER FAN AND ODOR DISAPPEARED. SUGGEST GASPER FAN REPLACEMENT.SDR UALA2009102603324Stiffener · crackedFLOORBEAM FWD FACE VERTICAL STIFFENER IS CRACKED STA 246, LBL 9. MAJOR REPAIR ACCOMPLISHED. INSTALLED ANGLE STIFFENER.SDR UALA2009102603323Stiffener · crackedCABIN FLOORBEAM FWD FACE VERTICAL STIFFENER CRACKED STA 246, RBL 11. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW STIFFENER.SDR UALA2009102303319Static Inverter · malfunctionedCREW REPORT STANDBY INVERTER MSG ON EICAS WITH SMOKE IN COCKPIT. STATIC INVERTER REPLACED. ALL CHECKS GOOD.SDR UALA2009102303317Anti-Ice Valve · stuckLEFT ENG ANTI ICE EICAS LIGHT CAME ON ATTEMPTING TO CLOSE ON GRD. APPEARS VALVE STUCK OPEN. REPLACED ENGINE INLET ANTI-ICE VALVE. OPS CHECK OKAY.SDR UALA2009102303310Light · unsecureSEAT 2B EEL LIGHTS LOOSE AND HANGING. RIPPED LOOSE FROM CARTS OR ROLLING ONBOARD LUGGAGE. RE-SECURED LIGHTS, OPS CHECK NORMAL.SDR UALA2009102303305Valve · malfunctionedENGINE NR 2 START VALVE LIGHT ILLUMINATED WITH START SELECTOR IN GND, ENGINE ROTATION WAS NORMAL. DID NOT ADD FUEL. NO START. REPLACED NR 2 ENG START VALVE. ENGINE STARTED NORMALLY WITH ALL INDICATIONS NORMAL.SDR UALA2009102303304Slide · unsecureDOOR 2L SLIDE AFT SIDE IS PARTIALLY UNLACED. RELACED & REINSTALLED SLIDE.SDR UALA2009102303318Starter · failedNO LIGHT OFF ON START OF LEFT ENG. RAN QRC. PUSH CREW ADVISED SPARKS SEEN FROM FRONT OF ENG. FOUND STARTER FAILED. REPLACED STARTER AND START VALVE. ACP'D IDLE RUN AND ALL OPS GOOD.SDR UALA2009102303307Oxygen System · faultyCAPTAIN'S O2 MASK SPRING TO TEST FLOW MALFUNCTIONING. REPLACED O2 MASK BOX.SDR UALA2009102303303Battery · dischargedEMERGENCY FLOOR LIGHTING LAST 6 ROWS ALTERNATINGLY COMING ON, WINDOW SEATING SECTIONS FOUND OVERHEAD EMERGENCY LIGHTS ON FIRST 6 ROWS ON RIGHT SIDE OF AIRCRAFT BY OVERWING EXIT DOORS TO BE MALFUNCTIONING. REPLACED BATTERY IN POWER SUPPLY UNIT M732, OPS CHECK SDR UALA2009102203291Valve · malfunctionedCHRONIC HYD TXF RT & CTR. CONDITION SUGGESTS FLUID XFER VIA ANTISKID SHUTTLE VALVES. REPLACED RT INBOARD SHUTTLE VALVE. NO LEAKS NOTED.SDR UALA2009102203289Battery · dischargedAISLE EMERGENCY LIGHTS FLICKERING ON IN AFT CABIN DURING FLT. REPLACED BATTERY AT 24AB AND OPS CHECK NOW NORMAL.
Back to Boeing 767-322