Boeing 767-322
Service difficulty reports · 11,768
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009113003669Skin · dentedDENT IN FUSELAGE BETWEEN STA 456 AND 478 D ENT IS 6 IN BY 6 N AND APPROX .380 DEEP BY- 10212 :DENT IS AT STA 570 NOT AT 456 AND 478 CONT OF AMIS ITEM 5892005 :REMOVED BELLY SKIN AND UPPER LAP ROW ON STR 36R FROM STA 573 THRU STA 626 DOWN TO BETWEEN STR 37R ANDSDR UALA2009112503662Pump · leakingLEFT HYD QTY SLOWLY DECREASING NOW AT .32. FOUND HYD LEAK COMING FROM LEFT ENG DRIVEN PUMP BODY. PUMP REPLACED. LEAK CHECK PERFORMED OKAY. LEFT HYD SYS FILLED UP. ALL OPS NORMAL.SDR UALA2009112503661Duct · rupturedON ARRIVAL FOUND WING ANTI ICE BLOW OUT PNL DISINTEGRATED AT THE LT WING STA 523AT. FURTHER T-S SHOWED COMPOSITE DUCT RUPTURED AT STA 523 AT JOINING METAL DUCT. REPLACED TAI DUCT. DISCONNECTED AND RECONNECTED SLAT CONTROL ROD AT BOTH ENDS OF SLAT NR 4. ACCSDR UALA2009112403660Fuel Tank · leakingUNWANTED FUEL TRANSFER. FUEL XFER FROM RT MAIN TO CNTR TANK. FOUND LEAK AT RT AUX FUEL TANK UPPER RIB 3. LOCATED RIGHT UPPER OF FUEL PLATE 631BB TOP OF STRINGER, MARKED. LOCATED LOOSE SHIM BETWEEN UPPER STRINGER AND O/B OF RIB 3, I/B OF RT MAIN TANK. BLOWSDR UALA2009112403656Light · inoperativeEEL LIGHT ON SEAT 6B INOPERATIVE. REPLACED EEL LIGHT ASSY, CHECKED NORMAL ON GROUND.SDR UALA2009112303653Controller · malfunctionedRT ENG BLEED LIGHT & RT ENG HPSOV EICAS MSG DURING CRZ, WITH ENG BLEED SWITCH ON, & ENG RUNNING. CREW COMMENTS: DUCT PRESS=17. CREW REPORTS 'BLEED' LIGHT AND EICAS INTERMITTENTLY APPEAR AND DISAPPEAR WITH VLV LOCKED OUT PER MEL. REPLACED NR 2 ENG HIGH STAGSDR UALA2009112303648Wire · shortedLEFT SYSTEM AND LEFT DEMAND PUMP LOW PRESSURE LIGHT ILLUMINATED WITH PUMP ON AND EICAS SHOWING 3000 PSI. ISOLATED M925 TIME DELAY MODULE AND CHECK RESISTANCE FROM M925 TO LOW PRESS CONNECTOR. METER SHOWED 1.6 OR WIRE GROUNDED. ISOLATED GROUND IN WIRE BUNDLESDR UALA2009112303647Controller · malfunctionedRIGHT BLEED LOSES PRESS WHENEVER THROTTLE IS IN LOW THRUST CONDITION. REPLACED PRESSURE REGULATING VALVE CONTROLLER. RAN ENG PNEU PRESSURE NORMAL.SDR UALA2009112303634Light · shortedINTERIOR EMERGENCY LIGHT INOP FROM SEAT 1HJ TO 6HJ. REPLACED BATTERY PACK, NO HELP. FOUND SEAT 1HJ 1EA LIGHT ASSY SHORTED. REPLACED EMERGENCY LIGHT ASSY. OPS CHECKED OK.SDR UALA2009112303654Gcu · malfunctionedRT GEN FIELD MAN RESET LIGHT IS ON. REPLACED GCU, OPS CHECKS GOOD.SDR UALA2009112303652Oxygen Mask · inoperativeFIRST OBSERVERS O2 MASK MIC DOES NOT TEST. THE 1ST OBSERVERS SEAT INOPERATIVE. REPLACED O2 MASK ASSY.SDR UALA2009112303646Switch · faultyRT WING ANTI ICE VALVE LIGHT AND EICAS ON WHEN WING ANTI ICE SELECTED. REPLACED RT WING TAI OVERHEAT SWITCH. REPLACED RT WING TAI VALVE. AFTER REPLACEMENT OPS TEST OKAY.SDR UALA2009112303636Rod · brokenFAN COWL HOLD OPEN ROD ON ENG NR 2 O/B SIDE, IS BROKEN AND UNUSABLE. REPLACED NR 2 ENG O/B FAN COWL HOLD OPEN ROD ASSY.SDR UALA2009112303651Stowage Box · faultyCAPT O2 MASK MIC NOT WORKING. REPLACED AUDIO ACC UNIT, NO HELP. MASK STORAGE BOX BAD FROM STOCK, SWAPPED OBSERVERS WITH CAPT'S MASK BOX UNIT, ALL CHECKS OK.SDR UALA2009112303631Power Supply · dischargedOVERWING EMERGENCY EXIT SIGN L297, L322, L699 AND L700 INOP. REPLACED M1209 EMERGENCY LIGHTS PWR SUPPLY. TEST OKAY.SDR UALA2009112003628Actuator · faultyONE SPAR VALVE LIGHT REMAINED ILLUMINATED WITH FUEL CONTROL SWITCH SELECTED (CUTOFF, RICH, RUN). EICAS MSG (L, R) SPAR VALVE DISPLAYED. REPLACED ENG FUEL SHUTOFF VALVE & OPS CHECKS NORMAL.SDR UALA2009112003622Skin · damagedSTATIC DISCHARGE ON CLIMBOUT. SILENT SURGE DETECTED. FOUND 3 LIGHTNING STRIKES JUST AFT OF STA 180.5 JUST ABOVE 27L. DRILLED DAMAGE AND INSTALLED SOLID FASTENER.SDR UALA2009112003629Shutoff Valve · malfunctionedAFTER ENG START R ENG HPSOV & ASSOCIATED BLEED VALVE ILLUMINATED. REPLACED HPSOV VALVE RT, RAN ENG; NO MESSAGES.SDR UALA2009112003627Anti-Ice Valve · malfunctionedEICAS MSG ENG ANTI-ICE DISPLAYED AND ENG ANTI-ICE VALVE LIGHT REMAINED ILLUM WITH SWITCH ON, POSITION 2. CREW COMMENTS: AFTER ENG START HAD TO CYCLE SWITCH SEVERAL TIMES AND BOOST POWER TO EXTINGUISH REPEAT. REPLACED NR 2 ENGINE ANTI-ICE VALVE, RAN ENGINE. SDR UALA2009112003626Charger · faultyMAIN BATTERY CHARGER STATUS MSG. REPLACED MAIN BATTERY CHARGER, CHECKS OKAY.SDR UALA2009111803595Circuit Card · faultedRT WING SLIDE EICAS, RTFL. FOUND S219 PROX SENSOR WIRING CHAFED AT AFT SIDE OF SLIDE COMPARTMENT, REPLACED SENSOR AND ASSOCIATED WIRING. FOUND HARD FAULT ON PSEU FOR PROX, LOGIC AND DRIVER CARDS FOR S219 SENSOR. REPLACED PROX, LOGIC AND DRIVER CARDS FOR S21SDR UALA2009111903608Panel · debondedAN 8 FT BY 1 FT UNDER WING PANEL JUST AFT OF LT MLG, ABOUT A 6 FT SECTION DISBONDED AND IS MISSING. FOUND ALL SCREWS IN PLACE. TRIMMED NEW PANEL FROM TEMPLATE. DRILLED AND COUNTERSUNK HOLES. PANEL PRIMED, PAINTED AND INSTALLED.SDR UALA2009111903607Light · inoperativeEMERGENCY LIGHTS BROKEN NEAR 2H. SEAT EEL LIGHT STRIP INOPERATIVE. REPLACED MISSING EEL LIGHT STRIP AND CHECKED EEL LIGHT. OPS OKAY.SDR UALA2009111803586Feeder Cable · faultyEMERGENCY LIGHT INOP SEAT 35H. REPLACED FEEDER CABLE. CHECKED NORMAL ON GROUND.SDR UALA2009111703584Engine · separatedCREW REPORT: LEFT ENGINE WOULD NOT SHUTDOWN WITH FUEL CONTROL SWITCH, PULLED FIRE HANDLE TO SHUT DOWN. FOUND NR 1 ENG, INTERMEDIATE PRS CHECK VLV SEPARATED FWD SIDE. LOW STAGE HOT AIR DAMAGED MULTIPLE WIRES UNDER VLV ON WIRE BUNDLES "W3506"AND "W3538" BELONSDR UALA2009111603545Computer · faultyLOWER EICAS SCREEN WENT TO ALL BLUE COLOR. WORKS NORMAL ON RIGHT COMPUTER. REPLACED RT EICAS COMPUTER. ACP SOFTWARE LOAD. OPS CHECK OKAY.SDR UALA2009111803602Shutoff Valve · malfunctionedLT & RT DUCT PRESSURE SPLIT DURING CRUISE, WITH ENGS RUNNING, LT & RT ISOL VLVS CLSD & BLEED SW ON. ACCOMPLISHED PNEU HEALTH CHECK. PRV & PRV CONTROLLER CHECKS GOOD, FAN AIR VALVE CHECKED GOOD, PRSOV FAILED. REPLACED PRSOV. NO HELP. REPLACED HPSV VALVE ANSDR UALA2009111803601Actuator · malfunctionedAPU WON'T START. STATUS MSG, APU DOOR. REPLACED INLET DOOR ACTUATOR, OPS CHECKS NORMAL.SDR UALA2009111603574Controller · faultyAPU WILL NOT START. REPLACED APU CONTROLLER. OP CHKS ARE GOOD.SDR UALA2009111603565Pressure Switch · faultyRIGHT CENTER FUEL PUMP LIGHT OUT PRIOR TO ENG START. SUSPECT PRESS SWITCH. REPLACED RT CENTER OVERRIDE PUMP PRESS SWITCH, CHECK OKAY.SDR UALA2009111603563Connector · disconnected2 FOOT SECTION OF EMERGENCY EXIT FLOOR LIGHTING IN FRONT OF L SIDE MID LAV BLINKING INTERMITTENTLY. RECONNECTED EMERGENCY LIGHT PLUG. CHECKED OKAY.SDR UALA2009111603560Monitor · faultyRT & LT HYD QTY LWR EICAS, RTFL. FAULT OCCURRED AFTER STATIC DISCHARGE. REPLACED HYDRAULIC FLUID QTY MONITOR UNIT. ALL OPS CHECKS SATISFACTORY.SDR UALA2009111603548Battery Pack · dischargedEMERGENCY LIGHTS INOP FROM ROW 27-34HJ. TRIED TO REPLACE BATTERY PACKS LOCATED BETWEEN SEATS 37 & 38HJ AND AT SEAT 22HJ, NO HELP. INSTALLED ORIGINAL BATTERY. DISCONNECTED EA SEAT FROM 27-34HJ FOR SHORTS, NO HELP. RE-INSTALLED AND SECURED BACK CONNECTORS. SDR UALA2009111303543Anti-Ice Valve · inoperativeEICAS MSG ENG ANTI-ICE DISPLAYED AND ENG ANTI-ICE VALVE LIGHT REMAINED ILLUM WITH SWITCH OFF, POSITION 1. PERFORMED T-S FOUND ENG ANTI-ICE VALVE INOP. REPLACED VALVE. RAN ENGINE. ENG ANTI-ICE VALVE WORKS OKAY.SDR UALA2009111303535Pressure Switch · defectiveCENTER FUEL PRESS LIGHT INOP. INOP RT CENTER FUEL PUMP. REPLACED RT CENTER OVERRIDE PUMP LOW PRESS SWITCH CHECK OKAY.SDR UALA2009111203529Oxygen Mask · brokenSECOND OBSERVER O2 MASK BROKEN. SWAPPED WITH CAPTAIN'S, NEED MASK AND BOX ASSY. REPLACED MASK AND STOWAGE BOX.SDR UALA2009111203527Wire · chafedNR 1 ENG OIL FILTER MSSG, FLIGHT DIVERTED. FOUND CHAFED WIRE IN WIRE HARNESS ON TOP OF NR 1 ENG CLOSE TO ELEC CONNECTOR JUNCTION BOX ON PYLON. WIRE WAS CHAFING ON METAL INSULATION BLANKET ON ENG, 3" AFT OF WIRE HARNESS SUPPORT BRACKET. NO STRANDS WHERE BROKESDR UALA2009111103526Computer · malfunctionedLEFT ENGINE OIL FILTER MESSAGE ON INTERMITTENTLY. REPLACED LEFT EICAS COMPUTER, ACP SOFTWARE LOAD OF DISK OPS 3171-COL-DEO-02 AND OPC 3100-BCG-006 -E7, ACP BITE TEST OF LEFT EICAS COMPUTER, TESTED GOOD, NO MESSAGES.SDR UALA2009111103525Transmitter · faultyRT IDG DRIVE LIGHT FLICKERING, RTFL. WHILE RT IDG DRIVE LITE WAS FLICKERING, RT ENG OIL PRESS INDICATION WAS BLANK. REPLACED RT ENG IDG. FOUND RT ENG OIL PRESS REF CB TRIPPED. ACCOMPLISHED VISUAL CHECK AND RING OUT OF WIRING FROM RT ENG OIL PRESS TXMTR TO SDR UALA2009111103524Actuator · dischargedEMER ESCAPE SQUIB TEST 2 FAILED DURING THE ARMING PROCESS. FOUND LEFT OFF WING ESCAPE SYSTEM SPOILER OVERRIDE ACTUATOR DISCHARGED, (ACTUATOR EXTENDED). REPLACED SPOILER OVERRIDE ACTUATOR, NO FAULTS.SDR UALA2009111103523Lens · unsecureEMERGENCY EXIT LENS COVER LOOSE AT 2R. SECURED LENS ON EMERGENCY LIGHT. OP CHECKED OKAY.SDR UALA2009111103522Battery · inoperativeAFT LAV LT SIDE EMERGENCY LIGHT INOPERATIVE. REF PTT SEQ 9522015. REPLACED BATTERY, OPS CHECKED, OKAY.SDR UALA2009111103521Battery · dischargedSEAT 35AB -41AB EMERGENCY LIGHT INOP. REPLACED BATTERY LOC SEAT 39AB. OPS CHECKED OKAY.SDR UALA2009111003515Pump · inoperativeRIGHT EDP EICAS MSG. OVERHEAT LIGHT CAME ON WITH LOW PRESS, CREW TURNED THE PUMP OFF AND OVERHEAT LIGHT WENT OUT, PUMP LOW PRESS LIGHT ON. REPLACED NR 2 ENG EDP. OP CHECKS NORMAL.SDR UALA2009111003516Starter · faultyNO ROTATION ON LEFT ENGINE WHEN ATTEMPTING TO ENGAGE STARTER. REPLACED STARTER & STARTER VALVE. OPS ARE NORMAL.SDR UALA2009110903499Light · inoperativeSEAT LIGHTS INOP AT SEATS 32B AND 35H. REPLACED BOTH EMERGENCY LIGHTS. OP CHECKS NORMAL.SDR UALA2009110903500Light · disconnectedEMERGENCY LIGHT AT SEAT 15H INOP. RECONNECTED EMERGENCY LIGHT, OPS CHECK NORMAL.SDR UALA2009110903469Pump · leakingEDP HYD OVHT LIGHT ILLUMINATED EICAS MSG (L,R) PRIM HYD OVHT DISPLAYED. PUMP WAS DEACTIVATED. POS 2 (01=L,02=R). CREW COMMENTS: R PRIM HYD PUMP OVHT SHUT OFF PUMP OVHT CAUTION EXTINGUISHED AFTER 12MIN 20SEC. SUPPLEMENTAL DATA UPDATE, FOUND NR 2 ENGINE (EDPSDR UALA2009110903508Circuit Card · faultyLT WING SLIDE ECAM INTERMITTENTLY CAME ON. CHECKED OVER WING SLIDE SENSORS S198 PINS C-5, D-5 RESISTANCE READ 13.5, S218 PINS A-5, B-5 RESISTANCE READ 18.6. REPLACED CARD DRIVER, OPS CHECKS NORMAL. NO EICAS MSGS WERE NOTED. NO LIGHTS AT LT OVERWING SLIDE.SDR UALA2009110903506Charger · faultyMAIN BATTERY CHARGER STATUS MESSAGE WON’T CANCEL. REPLACED MAIN BATTERY CHARGER, OP CHECKS OKAY.
Back to Boeing 767-322