SDR CALA2017071002153Slide · low pressureL2 DOOR SLIDE PSESSURE GUAGE READING SLIGHTLY LOW. REPLACED THE SLIDE IAW AMM 25-66-01-404-072 ,OPS CHECKED GOOD.SDR CALA2017071002130Altimeter · malfunctionedSTANDBY ALTIMETER 500 FT OFF. READS 32500 WHEN LEVEL 32000 ALTITUDE WITHIN LIMITS PER FIM CHART FIM 34-13-00-990-805 ALTIMETER TOLERANCE CHART.SDR CALA2017071002135Wire · burnedCREW REPORTED AFTER REACHING CRUISE ALTITUDE, NO POWER TO AFT GALLEYS. NO CIRCUIT BREAKERS TRIPPED, ALL GALLEY EQUIPMENT OFF. RESET UTILITY BUSS, GALLEY POWER RESTORED. JUST PRIOR TO TURNING GALLEY APPLIANCES ON, THE FLT ATTENDANT REPORTED AN ACRID ODOR FRSDR CALA2017070702107Blades · damagedDAMAGE FOUND TO A FAN BLADE ON NR 1 ENG, SUSPECT BIRD INGESTION. REMOVED 2 EACH BLADES BLADE NUMBER 12 AND BLADE NUMBER 31 BLADE IN NUMBER 12 POS S/N 3505 OFF S/N ON 9068 BLADE IN POS 31 S/N OFF 3444 S/N ON 9050 REF AMM TASK 72-31-02-004-001-N00 AND TASK 72-3SDR CALA2017070302093Cover · detachedEMERGENCY EXIT SIGN COVER IN LEFT AISLE DETACHED. SECURED THE SIGN COVER.SDR CALA2017070102075Oven · sparksMID CABIN OVEN R12 HAD SMOKE AND SPARKS WHEN TURNED ON. REMOVED AND REPLACED OVEN R12, IAW MM 25-31-00, OPS CHECK GOOD.SDR CALA2017070102066Battery Pack · not seatedEMERGENCY LIGHT KEEPS GOING ON AND OFF, RESEATED AND SECURED BATTERY PACK ASSY M737 AND ACCOMPLISHED EMERGENCY LIGHTS OPERATIONAL TEST IAW 33-51-00 PG 501 ALL OPS AND INDICATIONS NORMAL.SDR CALA2017063002029Lamp · inoperativeEXTERNAL EMERGENCY LIGHT AT BS 1197 + 33 DOES NOT COME ON DURING TEST. REPLACED THE LAMPS. OPS CHECKED GOOD.SDR CALA2017063002028Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT THE L2 DOOR DOES NOT COME ON DURING TEST. REPLACED THE LAMP. OPS CHECKED GOOD.SDR CALA2017063002030Lamp · inoperativeCEILING EMERGENCY LIGHT AT RIGHT ROW 27 DOES NOT TEST. REPLACED THE LAMP, TESTED OK.SDR CALA2017063002019Skin · corrodedDEEP BLEND OUT UNDER LOCK FASTENER HEAD EXPOSING PART OF COUNTERSINK THAT HAD LIGHT CORROSION UNDERNEATH ON UPPER SURFACE FUSELAGE CROWN SKIN BS 1307 OTBD OF STRINGER 1R. THE AREA WAS REPAIRED IAW SRM 53-00-01, RPR 29, FIG 201.SDR CALA2017063002018Skin · scratchedBS 654+30 - 654+36, STRINGERS 4L - 5L SKIN FOUND SCRATCHED. THE SKIN WAS REPAIRED IAW SRM 53-00-01, REPAIR 14, FIG 201.SDR CALA2017063002023Altimeter · out of toleranceSTANDBY ALTIMETER SHOWS +500 FEET WHEN LEVEL AT 34000. FOUND THE STANDBY ALT VIBRATOR INOPERATIVE, REMOVED AND REPLACED THE STANDBY ALTIMETER IAW AMM 34-13-06-334-031. OK TO CONTINUE.SDR CALA2017063002014Skin · crackedCRACKS WERE FOUND ON THE SKIN AT BS 1175, STRINGER 25L. REPAIRED IAW ECRA 5330-06113.SDR CALA2017062301951Lamp · inoperativeL1 DOOR SLIDE GREEN ILLUMINATION LIGHT INOPERATIVE. TROUBLESHOT IAW WDM 33-51-21, FOUND LIGHT NEEDS THE LAMP REPLACED. REPLACED THE LAMP. OPS CHECKED GOOD.SDR CALA2017062301950Sign · detachedEMERGENCY LIGHT MID ACFT, CAME DOWN AFTER LANDING. SECURED THE SIGN IAW AMM 33-15-02, OPS CHECKED GOOD.SDR CALA2017062301928Warning Message · false activationSELECTING FLAPS FROM 1 TO 5 LE SLAT ASYMETRY. EMERGENCY DECLARED. RAN QRH AND LANDED. TROUBLESHOT IAW WDM 27-88-22 PG1. COULD NOT DULPICATE FAULT. REMOVED AND REPLACED THE SENSOR S294 AS PRECAUTION IAW AMM 27-88-01-902-001. OPS CHECKED GOOD.SDR CALA2017061901904Light · pulledEMERGENCY EXIT ROW FLOOR STRIP LIGHT IS PULLED OUT OF FLOOR AND WIRES ARE EXPOSED. REINSTALLED LIGHT STRIP OPS CKS OK.SDR CALA2017061601823Controller · faultyPRESSURIZATION CONTROL AUTO INOPERATIVE LIGHT ILLUMINATED. OPERATION IN MANUAL MODE WAS OK. EMERGENCY DECLARED. FOLLOWED FIM 21-31-00-815-803. REMOVED AND REPLACED THE NR 2 AUTOMATIC PRESSURE CONTROLLER, OPS CHECKED GOOD IAW AMM 21-31-02.SDR CALA2017061201804Hose · leakingLOST CENTER HYD SYS IN FLIGHT. EMREGENCY DECLARED. REPLACED RIGHT MAIN GEAR RETRACT PRESSURE FLEX HOSE IAW GPM 1-13-021. OPS CHECKED NORMAL AND SERVICED CENTER HYD SYSTEM.SDR CALA2017061001787Oven · failedOVEN 106 FWD BURNS FOOD AND SMOKES. TEMP UNCONTROLABLE. FIRE HAZARD. R & R THE OVEN. ALL OPS OK.SDR CALA2017060901768Light · unsecureEMERGENCY FLOOR LIGHT STRIP CAME OFF. SECURED LT STRIP. OPS NML.SDR CALA2017060901767Lens · missing2 EA CEILING EMERG LIGHT LENS COVERS MISSING IN AFT PAX COMP. REPLACED LENS COVERS.SDR CALA2017060901766Lens · crackedEXT EMERG LIGHT SMALL LENS CRACKED LOC. LT JUST AFT OF IB FLAP T/E REPLACED LENS ASSY.SDR CALA2017060901765Lens · missingEMERGENCY CEILING LIGHT FIRST CLASS GALLEY MISSING COVER. REPLACED LENS COVER.SDR CALA2017060901741Fan · faultySTRONG BURNING SMELL IN FLIGHT DECK FOLLOWED BY L RECIRC FAN INOP LIGHT. REPLACED LT RECIRC FAN AND PERFORMED OPS CHECK. NO FAULTS FOUND IAW AMM21-25-01SDR CALA2017060901740Controller · faultyOVEN 106 OVERHEATS WHILE COOKING. BURNS FOOD AND SMOKES. TEMP CONTROL UNCONTROLLABLE. REMOVED AND REPLACED OVEN TEMP CONTROLLER. OVEN OPERATES NORMAL WITH CONTROLLING (CYCLING) TEMPERATURE.SDR CALA2017060501698Latch · wornLT WING SLIDE EICAS ADVISORY DISPLAYED AND OVERHEAD EMERG DOORS LIGHT ILLUMINATED. WHILE T/S FOUND SLIDE COMPARTMENT LATCHES WITH EXCESSIVE PLAY. REPLACED LATCHES AND ATTACHING HARWARE PRECAUTIONARILY. AMM 25-65-09 & AMM 52-21-01. EICAS ADVISORY MESSAGE EXTINSDR CALA2017060501690Wire Harness · damagedACRID ODOR BY SEATS 7AB/8AB. DISSAPATED AFTER IFE OFF. ABOVE SEATS WOULD ONLY RESET MAN BEFORE DEP. R & R THE WIRE HARNESS ASSY SEB TO SDU DISC AT 7ABSDR CALA2017060501680Altimeter · stickingSTBY ALTIMETER STICKING DURING CLIMB AND DECENT. REMOVED AND REPLACED STANDBY ALTIMETER IAW MM:34-13-06. OPS CHECKED GOOD.SDR CALA2017060501679Altimeter · inaccurateSTANDBY ALTIMETER 100 FOOT HAND. LAGS BY 500 FEET IN CLIMB. DESCENT AND IN LEVEL FLIGHT. REPLACED STAND BY ALTIMETER IAW AMM 34-13-06, PG 401.SDR CALA2017060201657Switch · failedFUMES IN COCKPIT DURING DESCENT. SMELLED LIKE ELECTRICAL FIRE. TRACED FUMES TO A FAULTY LEFT TURNOFF LIGHT SWITCH. REMOVED AND REPLACED PANEL ASSEMBLY AND TESTED IAW AMM 33-42-00-715-030. ALL OPS NOW NORMAL. R & R OF LIGHT ASSEMBLY PANEL.SDR CALA2017060201653Wire Harness · chafedLEFT ENGINE WIRE BUNDLE CHAFED AT PNEUMATIC LINE AFT & INBD OF FWD MOUNT. REMOVED & REPLACED WIRES W002-725/726-YR, & W002-727/725-YR IAW WDN 71-51-14 PG 1.B, BSWPM 20-10- 11, BSWPM 20-63-19 & RAN THE NR 1 ENGINE IAW JRH & AMM 71-00-00, TESTED GOOD.SDR CALA2017052701611Battery Pack · defectiveNUMEROUS EMERGENCY LIGHTS NOT STAYING ILLUMINATED MORE THAN 20 SECOND WHEN SWITCHED ON. TROUBLESHOT THE EMERGENCY LIGHTS AND REPAIR THE TIMING DELAY IAW AMM 33-51-02. OPS CHECKED GOOD IAW 33-51-02, 20 SECOND TIME DELAY OPS CHECKED GOOD IAW AMM 25-22-01, AND SDR CALA2017052701607Chiller · odorELECTRICAL ODOR IN AFT GALLEY. REMOVED AND REPLACED THE RT CHILLER. OPS CHECKED GOOD IAW AMM 25-33-02.SDR CALA2017052701622Strap · gougedDISCOVERED TWO GOUGES ON THE LOWER END ATTACH STRAP, REPAIRED IAW SRM 53-30-01, RPR 6, PAGES 201-5.SDR CALA2017052701620Frame · damaged(AD 5310-05292-9) DURING ACCOMPLISHMENT OF AD RELATED CARD FOR LH FRAME INNER CHORD REPAIR AT STA 883.5 FRAME WAS DAMAGED AT AREA OF REPAIR. REPAIRED LT INNER FRAME CHORD AT MAIN CABIN BS 883.5 IAW UNITED ECRA 5310-07141SDR CALA2017052701619Skin · corrodedAFT WASTE SERVICE PAN ATTACH DOUBLER BS 1570, BL 0 IS CORRODED. REMOVED, FABRICATED, AND INSTALLED AFT WASTE SERVICE PAN ATTACH DOUBLER IAW DWG 146T3250 AND SRM 51-40-02, PAR 7D, FIG 12.SDR CALA2017052601587Light · looseEMERGENCY LIGHT CENTER FLOOR STRIP AT ROW 21 HAS COME LOOSE. SECURED THE LIGHT.SDR CALA2017052601577Indicator · frozenDURING CLIMB FROM FL340 TO FL360, LEFT ALTIMETER FROZE AND OFF FLAG CAME INTO VIEW. REMOVED AND REPLACED THE CAPTAIN`S BAROMETRIC ALTIMETER INDICATOR IAW AMM 34-13-01. OPS CHECKED GOOD.SDR CALA2017052601567Shear Tie · corrodedAFT CARGO BAY, BS 1540 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 38L & 39L, FOUND TO BE OUT OF LIMITS. REMOVED, FABRICATED, LOCATED, DRILLED AND INSTALLED A NEW SHEAR TIE IAW SRM 51-40-02, PAR 4, & ENGINEERING DOCUMENT 140T2102, TYPE PL, REV FR.SDR CALA2017052601566Shear Tie · corrodedAFT CARGO BAY, BS 1562 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 39 L AND 39R. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02, PARA 4 AND 7.SDR CALA2017052601565Shear Tie · corrodedAFT CARGO BAY BS 1540 HAS CORROSION ON THE SHEAR TIE BETWEEN STRINGERS 38R AND 39R, OUT OF SRM LIMITS. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-40-02, PAR 4.SDR CALA2017052401553Fan · failedLEFT RECIRCULATION FAN EICAS C THE LEFT RECIRCULATION/ELECTRICAL EQUIPMENT EXHAUST FAN HAS A FA ILURE. ACCOMPANIED WITH BRIEF ELECTRICAL ODOR FOR TWO MINUTES THEN DISSIPATED. FLT ATTENDANTS BOTH CONFIRMED ODOR DISSIPATED AFTER LEFT RECIRCULATION FAN TRIP.SDR CALA2017052601559Stringer · corrodedCORROSION ON STRINGER 39R AT BS 1400. REMOVED DAMAGED SECTION OF STRINGER AND REPLACED WITH REPAIR IAW SRM 53-00-03, FIG 201, REPAIR 2.SDR CALA2017052201543Light · dirtyOUTSIDE DOOR 4R EMERGENCY LIGHT INOP. CLEANED CONTACTS ON THE BULB OPS CHECK GOOD PER AMM 33-51-06.SDR CALA2017052201542Fuse · burnedFOUND 1ST CLASS EMERGENCY AISLE LIGHTING NOT OPERABLE. (ROWS 1,2 AND 3) FROM FLIGHT ATTENDANT PANEL. OPENED OVERHEAD CEILING PANEL FOR ACCESS TO BATTERY PACK. FOUND 1 BURNT FUSE. REPLACED ALL 4 FUSES BITE CHECK FROM BATTERY PACK PROVES GOOD. DOES NOT OPERATE WSDR CALA2017052101510Unknown · odorELECTRICAL ODOR AND SHORT-LIVED THUMPING SOUND EMANATING FROM THE AFT GALLEY FLOOR. AMM 25-33-00. OPS CK NORMAL OK TO CONTINUE.SDR CALA2017051501420Battery Pack · inoperativeOVERWING FLOOR LEVEL EMERGENCY LIGHTS RIGHT SIDE INOPERATIVE. REPLACED THE BATTERY ASSY M01554 IAW AMM 33-51-07-002-014-002, AND 33 -51-07-402-018-002. TEST PASSED. OK FOR SERVICE.SDR CALA2017050801331Floorbeam · corrodedFLOORBEAM CORRODED AT BS 287, RBL 30 - 80. CORROSION REMOVED IAW SRM 51-10-02, BLEND OUT FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101. THE FLOORBEAM UPPER TEE WAS REPAIRED IAW SRM 53-00-51, REPAIR 1, FIG 201.
Back to Boeing 767-322