Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013070104550Skate Angle · crackedNR 2 ENGINE AFT LOWER PAN ATTACHMENT LOOSE, REMOVED NR 2 PYLON SAIL TAIL FOR INSPECTION AND REPAIRS. FOUND INBD SKATE ANGLE, STRAP, AFT FORMED WEB AND AFT VERTICAL WEB CRACKED.SDR UALA2013070104549Web · crackedNR 1 ENGINE LOWER AFT PAN ATTACHMENT APPEARS LOOSE. REMOVED NR 1 ENGINE PYLON SAIL TAIL FOR INSPECTION AND REPAIRS. FOUND AFT FORMED WEB CRACKED. ALSO FOUND AFT VERTICAL WEB CRACKED IN SAME LOCATION.SDR UALA2013062704505Ignition Unit · faultyAPU AT ALTITUDE WILL NOT START. APU HANGS BETWEEN 30 TO 50 PERCENT DURING START. APU STOPS AT 26 PERCENT. THREE ATTEMPTS. APU WILL NOT START TEST ECU SHOW INGNITION FAULT. REPLACED IGNITION UNIT AND APU STARTED SEVERAL TIMES.SDR UALA2013062704489Tray · damagedRIGHT WHEEL WELL PLASTIC WIRE HARNESS TRAY DAMAGED. RACEWAY FOUND CRACKED. RACEWAY HAS BEEN REPAIRED IAW ECRA 5700-03342.SDR UALA2013062704501Fan · failedSTATUS MESSAGE AFT EQUIPMENT EXHAUST FAN NR 1 DISPLAYED ON STATUS PAGE. PERFORMED TROUBLESHOOTING IAW FIM 21-26-00. FOUND CIRCUIT BREAKER FOR EQUIPMENT COOLING FAN NR 1 TRIPPED, UNABLE TO RESET. REPLACED RECIRCULATION FAN, OPS CHECKS GOOD.SDR UALA2013062704475Actuator · faultyAILERON LOCKOUT EICAS MESSAGE & OVERHEAD LIGHT CAME ON AT 9,000. REPLACED THE RT WING OTBD LOCKOUT ACTUATOR IAW SERVICE TIP AMM 27-11-44 P 200A. ACCOMPLISHED LOCKOUT & MECHANISM TEST IAW AMM. CLEARED ALL EICAS STATUS MESSAGES. ACFT OK FOR SERVICE.SDR UALA2013062704485Cover · missingARMREST MISSING COVER, EXPOSED WIRES. REPLACED ARM COVER, NO EXPOSED WIRES.SDR UALA2013062704486Power Supply · out of adjustCENTER PUMP LOW PRESSURE LIGHTS NOT COMING ON WITH PUMPS "ON" AND FUEL IN CENTER TANK. FOUND FUEL PANEL MAGNET POWER SUPPLY TO BE A OUT OF ADJUSTMENT. ADJUSTED SENSOR, OPS CHECKED OK.SDR UALA2013062704509Computer · faultyAUTO THROTTLE FAILED DURING TAKEOFF. TARGET EPR AND SPEED TAPE CYCLE INTERMITTENTLY ALSO. TMC FAILED FLT FAULT AND FAILS MCDP TEST 2. R & R TMC, TESTED GOOD. MCDP TEST 2,10& 30 PASS, ACFT REMAINS FULL CAPABILITY.SDR UALA2013062704502Tube · dentedTURBINE COOLING MANIFOLD, COOLING TUBE HAS A DENT EXCEEDING 20 PERCENT LIMIT ON NR 1 ENGINE RT SIDE, LOW PRESSURE SIDE. NEAR 3 O'CLOCK POSITION. REMOVED NR 1 ENGINE LPT COOLING MANIFOLD AC13 IAW MM. REPLACED ON NR 1 ENG COOLING MANIFOLD AC13.SDR UALA2013062704503Panel · missingNR 1 ENGINE NACELLE HAS ONE STRUT ACCESS PANEL MISSING OTBD 436AL. I INSTALLED PANEL 436AL OTBD NR 1 PYLON.SDR UALA2013062704488Oxygen Mask · unsecurePAX O2 MASK HAS FALLEN AT 1C. REPACKED O2 MASKS AT 1C.SDR UALA2013062704487Controller · inoperativeMID CABIN AUTO TEMP CONTROLLER INOPERATIVE.SDR UALA2013062704506Seal · damagedR2 COCKPIT WINDOW SEAL DAMAGED. REPLACED SEAL.SDR UALA2013062504422Video Monitor · failedCABIN VIDEO SCREEN PRODUCED SMOKE AND IS INOPERATIVE AT SEAT 6B. TURNED OFF ENTIRE IFE SYS AND SMOKE FROM MONITOR AT 6B STOPPED. INSPECTED ALL CABLE HARNESSES GOING TO MONITOR WITH NO DEFECTS NOTED. FOUND SMOKE ODOR AT BACK OF MONITOR AND GROUND STUD BROKESDR UALA2013062604438Fan · failedFWD EQUIPMENT EXHAUST FAN INOPERATIVE WITH STATUS MESSAGE. REPLACED FWD EQUIPMENT EXHAUST FAN IAW AMM.SDR UALA2013062704508Line · leakingHYD LEAK, RT WING JUST INBD OF INBD AILERON. FOUND DC MOTOR OPERATED SHUTOFF LATERAL CONTROL EMPENNAGE VALVE LEAKING. CYCLED LATERAL CONTROL VALVE, AND TIGHTENED PRESSURE LINE, NO LEAKS NOTED.SDR UALA2013062704512Fuel Cell · leakingDURING MX, FOUND FUEL LEAKING BS 955, RIGHT WHEEL WELL FORWARD AT S20R. FUEL LEAK REPAIRED IAW RO 5130438. LEAK CHECKED GOOD.SDR UALA2013062504408Lamp · inoperativeEMERGENCY AISLE LIGHT AT ROW 38KJ INOPERATIVE. REPLACED LAMP IAW AMM. OPS CHECKED NORMAL.SDR UALA2013062504407Lamp · inoperativeEMERGENCY AISLE LIGHT AT ROW 35AB IS INOPERATIVE. REPLACED LAMP, OPS CHECKED NORMAL.SDR UALA2013062504406Lamp · inoperativeEMERGENCY SLIDE LIGHT AT R2 DOOR INOPERATIVE. REPLACED LAMP IAW AMM, OPS CHECKED NORMAL.SDR UALA2013062504405Lamp · inoperativeEMERGENCY SLIDE LIGHT AT L1 DOOR INOPERATIVE. REPLACED LAMP IAW MM 33-51-06-902-082. OPS CHECKED NORMAL.SDR UALA2013062704507Antenna · damagedWEATHER RADAR PAINTS SIGNIFICANT GROUND RETURN ON LEFT SIDE, WITH NO VISIBLE MOISTURE (OR TERRAIN). TROUBLESHOT & CHECKED FOR MOISTURE REF 53-12-01. NO MOISTURE FOUND, INSPECTION OF FLAT ANTENNA HAS DAMAGE LOWER LEFT CORNER BENT. R & R FLAT PLATE ANTENNA.SDR UALA2013062504421Oxygen Mask · failedFIRST OFFICER`S OXYGEN MASK LOUD SQUEAL WHEN AIR COMES OUT. R & R OXYGNE MASK IAW AMM 35-11-51. LEAK AND OPS CHECKED GOOD.SDR UALA2013062504414Actuator · leakingSPOILER NR 11, SMALL HYD LEAK ON EXTENSION CHECK AND THERMAL RELIEF VALVE, 2 DROPS. REMOVED AND REPLACED NR 11 SPOILER ACTUATOR PER AMM, OPS AND LEAK CHECKED GOOD,SDR UALA2013062704511Panel · corrodedAPPEARS TO BE AREA OF CORROSION & DELAMINATION BELOW ADP EXHAUST OUTLET. REMOVED DAMAGED AREA FROM PANEL 191KL AND REPAIRED IAW SRM. SEALED PRIMED AND PAINTED IAW MM 51-21-00.SDR UALA2013062604424Drive Unit · failedRT GENERATOR DRIVE LIGHT NOT ILLUMINATED. ALSO, RT GENERATOR FIELD LIGHT NOT ILLUMINATED. REPLACED RT GENERATOR DRIVE AND RT GENERATOR FIELD PUSH BUTTON SWITCHES. OPS CHECKED GOOD.SDR UALA2013062604423Charger · failedMAIN BATTERY CHARGER STATUS MESSAGE WILL NOT CLEAR. REPLACED BATTERY AND BATTERY CHARGER.SDR UALA2013062504392Processor · inoperativeRT FUEL QTY INDICATOR IS INOPERATIVE ON OVERHEAD. R & R FUEL QTY PROCESSOR IAW MM. OPS NORMAL.SDR UALA2013062104345Pump · leakingCENTER HYD STATUS MESSAGE. C2 HYD PUMP ONLY SHOWING 2700 PSI. MIN IS 2850. REPLACED C2 HYD PUMP, LEAK AND OPS CHECKED GOOD.SDR UALA2013062504393Sign · dislodgedEMERGENCY EXIT SIGN AT ROW 21 FELL OFF. SECURED EXIT SIGN.SDR UALA2013062104343Oxygen Mask · unwanted deployCABIN OXYGEN MASK DEPLOYED AT 19K. REPACKED OXYGEN MASK IAW MM 35-21-00-501 & 35-21-10-532-116.SDR UALA2013062104348Wire · damagedFOUND FIRE LOOP WIRE W3520-501R-16 ON RT ENGINE WITH ABRASION MARKS. REPLACED NR 2 ENGINE FIRE LOOP WIRE. FIRE WALL FIRE DETECTOR TS681 REPLACED AND SYSTEM BITE TEST CARRIED OUT FOUND NORMAL IAW AMM 26-11-00, SWPW 20-00-13, & WDM 26-11-21SDR UALA2013062104322Satcom · malfunctionedSATCOM EICAS AND SATCOM HI GAIN STATUS MSG DISPLAYED. REPLACED RFU IAW AMM. OPS CHECKED GOOD.SDR UALA2013062004286Data Unit · failedSATCOM STATUS MESSAGE. REPLACED SATELLITE DATA UNIT IAW AMM.SDR UALA2013062004285Data Unit · failedSATCOM EICAS MESSAGE AND SATCOM HIGH GAIN STATUS MESSAGE DISPLAYED. R & R SATCOM DATA UNIT IAW AMM 23-25-10. ALL FUNCTIONS ARE NORMAL.SDR UALA2013062104346B-Nut · looseEVIDENCE OF HYD FLUID ON RT OTBD AILERON. FOUND LOOSE B-NUT ON PRESSURE LINE TO RT OTBD AILERON. TIGHTENED AND LEAK CHECKED. OPS CHECKED GOOD, NO LEAKS NOTED.SDR UALA2013062004287Warning Message · illuminatedSATCOM LOW GAIN STATUS MESSAGE. SATCOM HIGH GAIN VOICE DATA OPS NORMAL.SDR UALA2013062104344Coupler · failedHF RECEPTION WEAK, INTERMITTENT, ERRATIC. ALL FREQS TRANSMISSIONS OK. REPLACED LEFT HF COUPLER, IAW AMM 23-11-01, ACCOMPLISHED LOCAL AND LONG DISTANCE CHECK, TESTED GOOD.SDR UALA2013062104342Shutoff Valve · failedLEFT ENGINE HPSOV EICAS MESSAGE ON LANDING. LEFT HPSOV INOPERATIVE IN CLOSED POSITION. BOTH ENG GENERATORS & APU GEN ARE OK. REPLACED NR 1 ENGINE HPSOV IAW MM.SDR UALA2013062104341Insulation · missingNR 1 ENGINE IDG CABLE LUG INSULATION MISSING ON TOP TERMINAL END. REPLACED POWER FEEDER CABLE COLOR SLEEVE REF SWPM 20-10-14.SDR UALA2013061904251Lamp · inoperativeEMERGENCY EXIT LIGHT BETWEEN ROWS 37 AND 38 RIGHT INOPERATIVE. REPLACED LAMPS, OPS CHECKED NORMAL.SDR UALA2013062004289Indicator · malfunctionedFUEL TANK AND TOTAL FUEL QTY INDICATOR INOPERATIVE. INDICATOR BLANK EICAS MESSAGE, FUEL QTY INDICATOR NOT DISPLAYED. PERFORMED OPS AND BITE CHECK OF FQIS. ALL OPS, INDICATION AND BITE CHECKED GOOD. PROCESSOR SHOWS NO CURRENT FAULTS.SDR UALA2013062004284Duct · looseLOUD AIR NOISE AT ROW 32 OVER MIDDLE SEATS. FOUND OFF TAKE FROM GASPER DUCT ABOVE ROW 32 DEF LOOSE. INTERIM REPAIR CARRIED OUT. OFF TAKE SECURED WITH TIE WRAPS OK.SDR UALA2013062004291Shutoff Valve · failedLEFT ENGINE BLEED OFF EICAS, NO AIR AVAILABLE WHEN ENGINE UP AND CYCLED S11 BREAKER. ACCOMPLISHED HEALTH CHECK IAW 36-00-99. FOUND PRSOV FILTER MORE THAN 90% CLOGGED. FOUND PRV SHAFT WORN OUT AND PRV CONTROLLER OUTSIDE OF HEALTH CHECK PARAMETERS. REPLACED SSDR UALA2013061904255Actuator · leakingRUNNING HYDRAULIC LEAK OBSERVED FROM THE TAIL AREA. RT HYDRAULIC INDICATING 0.80. FOUND LOWER RUDDER PCA LEAKING. R & R LOWER PCA IAW AMM. RII PERFORMED.SDR UALA2013062004290Cover · damagedR1 DOOR SLIDE RAFT COVER DAMAGED. COMPLIED WITH EC RA 5211-01348 REQUIREMENTS. TAPE APPLIED AS INTERIM.SDR UALA2013062004288Line · leakingFOUND LEAK ON FLEX LINE BETWEEN STAB TRIM CONTROL MODULE AND STAB TRIM ACTUATOR. REPLACED LINE, LEAK CHECKED NORMAL.SDR UALA2013061804231Actuator · leakingLEFT HYDRAULIC SYS DOWN TO .85 ON ARRIVAL. NOTED HYD FLUID ON TAIL AREA OF ACCESS PANEL TO HORIZONTAL STABILIZER. SERVICED HYD SYS TO FULL. CLEANED TAIL AREA ENTERED ACCESS PANEL TO HORIZONTAL STABILIZER BAY FOUND LEFT AP ELEVATOR SERVO ACTUATOR ROD LEAKINGSDR UALA2013061704177Selector Panel · faultedNR 2 AUDIO SELECTOR PANEL VOLUME CONTROL DEFECTIVE. REMOVED AND REPLACED FIRST OBSERVER`S AUDIO SELECTOR PANEL.
Back to Boeing 767-322