Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013042602929Spring · missingLEFT MLG FWD DRAG BRACE OVERCENTER SPRING MISSING. REPLACED MISSING SPRING.SDR UALA2013042602948Controller · no testNR 2 ENGINE HPC PNEUMATIC HEALTH CHECK TEST FAILED. NR 2 ENGINE HPC REPLACED AS PER AMM.SDR UALA2013042602947Shutoff Valve · seizedNR 2 ENGINE HPSOV TEST PORT FOUND SEIZED. NR 2 ENGINE HPSOV REPLACED AS PER AMM 36-11-07.SDR UALA2013042502903Sign · missingR1 DOOR EMERGENCY EXIT SIGN MISSING. REPLACED SIGN.SDR UALA2013042602927Accumulator · low pressureBRAKE ACCUMULATOR PRESSURE BLED DOWN QUICKLY WITHOUT PUMPS ON. TROUBLESHOT PER FIM 32-41-00. FOUND ACCUMULATOR PRECHARGE LOW. SERVICED ACCUMULATOR PER AMM AND OPS CHECKED GOOD, NO LEAKS NOTED.SDR UALA2013042302823Pump · vibrationDUE TO REPEAT AIRFRAME VIBRATION, FOUND VIBRATION COMING FROM ADP HYD PUMP AND ADP PRSOV. ADP HYD PUMP REMOVED PER AMM. ADP HYD PUMP INSTALLED PER AMM. OPS CHECKED NORMAL & NO VIBRATION. ADP PRSOV CHANGED PER AMM 29-11-30. VALVE OPS CHECKED NORMAL.SDR UALA2013042402848Light · dimCOCKPIT DOOR AREA OVERHEAD EMERGENCY LIGHT IS DIM. EMERGENCY LIGHT ASSY REPLACED AND OP TESTED NORMAL AMM.SDR UALA2013042402847Light · inoperativeSEAT 39B EMERGENCY LIGHT INOPERATIVE. EMERGENCY LIGHT ASSY REPLACED, OPS CHECKED NORMAL IAW MM.SDR UALA2013042402846Inlet · dentedNR 1 ENGINE INLET COWL DENTED. REPAIRED.SDR UALA2013042402845Fairing · delaminatedRIGHT ENGINE PYLON INBD AFT FAIRING HAS DELAMINATION. PERFORMED METAL BOND REPAIR PER AMM.SDR UALA2013042502902Pcu · leakingLEFT HYD FLUID LOSS, FLIGHT DIVERTED. REPLACED MIDDLE RUDDER PCU DUE TO A RUNNING LEAK IAW MM. OPS CHECKED NORMAL, NO LEAKS.SDR UALA2013042302827Selector Panel · faultyEICAS DISPLAY SELECT PANEL TEST BUTTON DOES NOT WORK. REPLACED EICAS DISPLAY PANEL, TESTED OKAY.SDR UALA2013042302822Clamp · leakingLEFT BLEED DUCT LEAK EICAS ON AND LEFT DUCT LEAK LIGHT. FOUND CLAMP LOOSE AT SENSE LINE FROM ACM TO HEAT EXCHANGER. RETORQUED NUMEROUS DUCT CLAMPS IN RIGHT AC BAY AND LEAK WENT AWAY. RAN ENGINE 5 MINUTES. NO FURTHER DUCT LEAK MESSAGES.SDR UALA2013042302821Brake Assy · leakingRIGHT TRUCK OUTER AFT WHEEL ASSEMBLY LEAKING FLUID. NR 4 AFT BRAKE LEAKING ONE DRIP PER MINUTE. NO LEAK WITH PRESSURE OFF. REPLACED BRAKE AS PER AMM 32-41-08 P603.SDR UALA2013042302837Lamp · inoperativeEMERGENCY LIGHT AT SEAT 9HJ INOPERATIVE. REPLACED LAMPS, OPS NORMAL.SDR UALA2013042302825Altimeter · inoperativeCAPTAIN`S ALTIMETER ANNUNCIATOR INOPERATIVE. REPLACED DEFECTIVE ALTIMETER. GROUND TESTED GOOD IAW MM.SDR UALA2013042302820Line · leakingRIGHT HYD SYSTEM LEAK AT PYLON. REMOVED NR 2 ENGINE THRUST REVERSER ISOLATION VALVE HYD PRESSURE LINE. REPLACED LINE WITH A FLEXIBLE LINE IAW GPM 1-0-13-003 PG 10. OPS AND LEAK CHECKED OK.SDR UALA2013042302819Wire · chafedFOUND WIRE W288-002-8 CHAFED AT SPLICE SM002. REMOVED AND REPLACED WIRE FROM RT ELECTRIC HYDRAULIC PUMP TO SM2 IAW WDM 29-11-22 AND SWP 20-30-13. OPS CHECKED IAW AMM 29-11-01. LEAK CHECK OK.SDR UALA2013042302838Lamp · inoperativeEMERGENCY LIGHT AT SEATS 27, 30, 31, 34 & 37 JK ONE LAMP INOPERATIVE. REPLACED LAMP, OPS NORMAL.SDR UALA2013042302836Lamp · inoperativeEMERGENCY LIGHT AT SEAT 35B INOPERATIVE. REPLACED LAMPS, OPS NORMAL.SDR UALA2013042302828Light · inoperativeEMERGENCY LIGHT AT OVER WING EXIT LOWER NEAR SEAT 19HJ INOPERATIVE. TROUBLESHOT AND FOUND DEFECTIVE LIGHT. REPLACED OVERWING EXIT LIGHT ASSY. OP'S CHECKED GOOD.SDR UALA2013042302826Warning Light · false activationLT PACK BITE AND RT PACK BITE EICAS MAINTENANCE MESSAGES DISPLAYED. BITE CHECKED RT AND LT PACKS, MESSAGES GONE. CHECKED GOOD REF MM.SDR UALA2013042302824Lens · missingEMERGENCY LIGHT AT SEAT 27JK MISSING LENS. REPLACED LENS. GROUND TESTED GOOD.SDR UALA2013042202753Actuator · leakingRUNNING HYD LEAKAGE FROM VERTICAL STABILIZER. INDENTIFIED LEAKING COMING FROM RUDDER RATIO ACTUATOR (RRCA) ROD END. RRCA NEED REPLACEMENT REF AMM 27-21-15.SDR UALA2013042202778Shutoff Valve · faultyDUE TO REPORTS OF LEFT PACK WOULD NOT COME ON WITH ENG BLEED, REPLACE LEFT PACK FLOW CONTROL AND SHUTOFF VLV PER MM. FLOW CTL AND SHUT OFF VLV REPLACED, LEAK CHECK PERFORMED WITH APU BLEED SATISFACTORY.SDR UALA2013042202780Actuator · leakingHYDRAULIC LEAK COMING FROM LEFT OUTBD AILERON. LEAK WAS FROM AILERON ACTUATOR ROD, APPROX 15 DRIPS PER MINUTE WITH PRESSURE ON 0 WITH PRESSURE OFF.SDR UALA2013042202779Hose · leakingBLUE FLUID LEAKING FROM BELLY DRAIN JUST FWD OF SERVICE PANEL WHEN RINSING LAV TANKS. REPLACED FILL LINE HOSE PER AMM 38-00 AND LEAK CHECKED.SDR UALA2013042202782Unknown · leakingHYDRAULIC FLUID STREAMING DOWN APU COMPARTMENT, LEAK IS COMING FROM RUDDER AREA, SUSPECT PCU OR BROKE LINE. INSPECTED AREA FOUND NO LEAKS.SDR UALA2013042202754Indicator · faulted"L/E SLAT ASSY" EICAS, RETURNED TO FIELD. REMOVED AND REPLACED FLAP INDICATOR. OK FOR SERVICE, NO FAULTS NOTED.SDR UALA2013042202770Blocker Door · damagedDURING ARRIVAL, WALK AROUND FOUND NR 1 ENGINE 2 O'CLOCK BLOCKER DOOR NOT FLUSH. REMOVED LEFT ENGINE BLOCKER DOOR AND DRAG LINK. LEFT THRUST REVERSER OPS CHECKED OK. REPLACED BLOCKER DOOR AND BLOCKER DOOR DRAG LINK, OP CHECKED GOOD.SDR UALA2013042202771Controller · inoperativeLEFT FWD WINDOW HEAT INOPERATIVE. REMOVED AND REPLACED THE WINDOW HEAT CONTROLLER M191, REF 30-41-01. OPS CHECKED GOOD.SDR UALA2013042202752Pitot Tube · failedIN FLIGHT, EICAS MESSAGE DISPLAYED FOR PITOT. PITOT PROBE HEAT LIGHT ILLUMINATED. PERFORMED FIM TASK AS 30-31-00, FOUND F/O PITOT AT FAULT. REMOVED AND REPLACED PITOT PROBE AS PER MM. OPS CHECKED GOOD, ALL INDICATIONS GOOD.SDR UALA2013041902709Circuit Breaker · failedRUDDER TRIM INDICATION WHITE NEEDLE GONE. FOUND CIRCUIT BREAKER K18, RUDDER IND OUT. RESET BY CREW. INDICATION NORMAL.SDR UALA2013042202781Fastener · missingWHILE PERFORMING MF8840, FOUND ONE MISSING FASTENER ON NR 2 ENGINE OUTBD PYLON HEATSHIELD. REPAIRED.SDR UALA2013041902710Display · failedCREW REPORTED ACARS INOPERATIVE. REPLACED ACARS IDU AND OPS CHECKED.SDR UALA2013041802658Indicator · failedSTANDBY ATTITUDE INDICATOR FAILED, RETURNED TO FIELD. CIRCUIT BREAKER DID NOT TRIP AND GYRO TUMBLED. REPLACED STANDBY ATTITUDE INDICATOR.SDR UALA2013041802660Receiver · faultedCAPTAIN`S RIGHT NAV HAS OFF FLAG. FAULT TRACED TO RT VOR RECEIVER. RT VOR RECEIVER REPLACED IAW AMM. RT VOR RECEIVER BITE ACCOMPLISHED. SATISFACTORY.SDR UALA2013041702626Cable · looseCABIN TEMP TOO HOT & UNCONTROLLABLE. FOUND RESTRAINT CABLES LOOSE ON ELBOW AT REHEATER. TIGHTEN AND SECURED HARDWARE ON RESTRAINT CABLE. OPERATED PACKS AND LEAK CHECK ALL INDICATIONS NORMAL, NO LEAK NOTED.SDR UALA2013041802659Pump · faultedFUEL CONFIGURATION LIGHT AT 2.6 OUT OF BALANCE. FOLLOWED QRH PROCEDURE AND REBALANCED. TROUBLESHOT IAW SERVICE TIP 28-11-94. NO DISCREPANCIES NOTED. REMOVED AND REPLACED RIGHT CTR OVERRIDE FUEL PUMP IAW AMM, OPS AND LEAK CHECKED GOOD.SDR UALA2013041802657Pump · unknownCENTER FUEL PUMP PRESSURE LIGHT DOES NOT ILLIMINATE ON EICAS, BUT SHOWS ON OVERHEAD PUMP SWITCHES. TURNED ON OTHER MAIN BOOST PUMPS, CENTER FUEL BOOST PUMPS TEST NORMALLY.SDR UALA2013041702624Control Unit · failedAPU AUTO SHUTDOWN. RAPID EGT RISE 775-790, THEN AUTO SHUTDOWN AFTER RPM STABILIZED AT 22. REPLACED APU CONTROL UNIT AS PER AMM. APU STARTS AND OPERATES NORMALLY.SDR UALA2013041702625Wire Harness · failedNR 2 ENGINE EGT MESSAGE. REPLACED RIGHT AFT EGT HARNESS AND 'J' BOX. RAN ENGINE AND FOUND NORMAL OPS AND INDICATIONSSDR UALA2013041502577Pump · faultyRIGHT ELEC HYD PUMP PRESSURE IS LOW (2500 PSI) AS INDICATED ON HYD PAGE & BRAKE PRESSURE INDICATOR. REMOVED RIGHT HYD AC MOTOR PUMP. PUMP IS ON TABLE NEXT TO NR 2 ENGINE. INSTALLED RIGHT HYDRAULIC ACMP, LEAK CHECK GOOD.SDR UALA2013041602603Switch · unsecureCENTER OVERHEAD RIGHT BOOST PUMP SWITCH IS HANGING DOWN FROM THE PANEL. REPLACED SWITCH ASSEMBLY, OPS CHECKED NORMAL.SDR UALA2013041502595Charger · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEATS 1AB TO 9AB. REPLACED EMERGENCY LIGHT CHARGER PER AMM.SDR UALA2013041502576Actuator · leakingCENTER HYD LEAK ON RIGHT WING SPOILER. FOUND NR 10 SPOILER PCA LEAKING FROM FILTER CASE. REPLACED PCA AS PER MM 27-61-02 ALL OPS AND INDICATIONS NORMAL NO LEAKS AFTER FUNCTIONAL TEST.SDR UALA2013041502562Charger · failedMAIN BATTERY CHARGER STATUS MESSAGE. REMOVED AND REPLACED MAIN BATTERY CHARGER IAW AMM. ALSO BATTERY REPLACED. STATUS MESSAGE CLEARED AND MAIN BATTERY CHARGER OPS OKAY.SDR UALA2013041502544Pressure Switch · failedLEFT AFT FUEL PUMP LIGHT IN SWITCH STAYS ILLUMINATED WITH SWITCH ON. REPLACED PRESSURE SWITCH.SDR UALA2013041502543Seal · missingA SIX INCH RUBBER SEAL MISSING FROM RIGHT ENGINE INBD PYLON WING ROOT. REPLACED SEAL.SDR UALA2013041502542Contact · dirtyAFT CARGO FIRE EXTINGUISHER ARM LIGHT DOES NOT ILLUMINATE DURING FIRE TEST. CLEANED AND RESEATED CONTACTS ON ARM LIGHT. OPS TESTED NORMAL.
Back to Boeing 767-322