Boeing 767-322
Service difficulty reports · 11,764
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013041202523Battery · inoperativeR2 DOOR EMERGENCY LIGHT BATTERY INOPERATIVE. BATTERY REPLACED AND OPS TESTED NORMAL IAW MM.SDR UALA2013041202524Hook And Loop · looseLIFE VEST POUCH ON CAPT SEAT IS LOOSE. REPLACED VELCRO ALL OPS OK.SDR UALA2013041202520Cylinder · dischargedLEFT OVERWING SLIDE INFLATION CYLINDER REQUIRES REPLACEMENT DUE TO PREVIOUS INADVERTENT DEPLOYMENT. INSTALLED LEFT OVERWING SLIDE INFLATION CYLINDER ASSY IAW 767-300 AMM.SDR UALA2013041202511Control Module · faultyINOP FORWARD TANK LIGHT ON REAR FLT ATTEND PANEL. REPLACED ALTITUDE PRESSURE SWITCH (SEQ 9312011) LOGIC CONTROL MODULE AND CHECK VALVE (SEQ 9312012) AIRCRAFT RETURNED TO GATE. BITE CHECK OF NEW LOGIC CONTROL MODULE SHOWED LOGIC CONTROL MODULE IS BAD. REPLACSDR UALA2013041202526Wire · damagedLEFT ENGINE FIRE LOOP 2 STATUS MESSAGE INTERMITTENTLY IN FLT. FOUND FIRE LOOP WIRES INSULATION AND BROKEN STRANDS DEFECTIVE. WIRE REPAIRED IAW MM 71-51-00. GROUND FUNCTIONAL TESTED GOOD.SDR UALA2013041202525Clamp · defectiveNR 1 ENGINE FEEDER CABLE CLAMP INSULATION BAD AT 10:00 POSITION. REPLACED DEFECTIVE CLAMP.SDR UALA2013041202510Wire · defectivePIGTAIL IN ECON GALLEY SMOKING. P52 LOC. PULLED AND CAPPED P52 CB. REPLACED PIGTAIL.SDR UALA2013041202509Connector · faultedWHEEL WELL FIRE LIGHT FAILED TO ILLUMINATE DURING TEST. RESEATED CONNECTOR M691, GROUND CHECKED OK IAW MM 26-17-00SDR UALA2013041202516Handset · malfunctionedCABIN HANDSET R2 DOOR CHIME AND COMMUNICATION INTERMITTENT SOMETIMES CUTS FROM INTERCOM TO PA. REPLACED HANDSET, OPS CHECKED NORMAL.SDR UALA2013041202522Actuator · leakingNR 10 SPOILER ACTUATOR LEAKING HYDRAULIC FLUID FROM ACTUATOR FILTER CAP. NR 10 SPOILER FILTER CAP FITTED WITH NEW SEALS FILTER CAP TIGHTENED AND WIRE LOCKED PER AMM. ACP FUNCTIONAL CHECKED, NO LEAKS DETECTED.SDR UALA2013041002417Computer · faultedRIGHT ENGINE START EGT STATUS MESSAGE CAME ON DURING CRUISE. REPLACED LEFT EICAS COMPUTER, OPS CHECKED GOOD.SDR UALA2013041102460Detection Sys · inoperativeWHEEL WELL FIRE LIGHT FAILED TO ILLUM DURING TEST. WHEEL WELL FIRE TEST OVERHEAT INOP DEFERRED IAW MEL.SDR UALA2013041002416Cover · damagedWIRE CHASE COVER HAS HOLES AND IS HANGING DOWN. REMOVED AND REPLACED COVER, AC OK TO CONTINUE.SDR UALA2013041102461Warning Light · false activationLEFT BLEED DUCT LEAK ILLUMINATED. EFTL BLEED LIGHT ON MOMENTARILY WITH APU BLEED ON ONLY. ACCOMPLISHED VISUAL INSPECTION ACCESSIBLE DUCTING FOR LEAKS, NO LEAK DETECTED. REPLACED M691 BLEED CARD AS PRECAUTION. NO LIGHT AT THIS TIME, OPS CHECKED NORMAL.SDR UALA2013041002419Motor · failedNR 2 CABIN ALTITUDE AUTO STATUS MESSAGE. REMOVED AND REPLACED OUTFLOW VALVE MOTOR PER AMM.SDR UALA2013041002418Transceiver · faultyTERR FAIL MSG ON CAPTAIN'S SIDE. REPLACED WX TRANX PER AMM, OPS CHECK GOOD AND EFIS CONTROL PANEL PER AMM, OPS CHECK GOODSDR UALA2013041002420Blade · tornRIGHT ENGINE FAN BLADE NR 15 HAS A TEAR IN THE LEADING EDGE, NEAR THE TIP. BLENDED DAMAGE OUT OF NR 2 ENGINE. FAN BLADE NR 15. DAMAGE WAS IN AREA A, WAS REMOVED PER AMM 72- 31-02.SDR UALA2013040902369Pump · leakingNR 1 ENGINE HYDRAULIC PUMP FOUND LEAKING FLUID. REPLACED EDP PER MM AND CASE DRAIN AND PRESSURE FILTERS PER MM. TEST E AND LEAK CHECKED NORMAL.SDR UALA2013040902367Anti-Ice Valve · failedEICAS MESSAGE, ENGINE ANTI-ICE DISPLAYED AND ENGINE ANTI-ICE VALVE LIGHT REMAINED ILLUMINATED WITH SWITCH OFF. NR 1 REMOVED AND REPLACED LEFT ENGINE ANTI-ICE VALVE PER AMM. NO HELP. REPLACED NOSE COWL ANTI-ICE VALVE FROM KNOWN GOOD NR 2 ENGINE AS PER AMM.SDR UALA2013040802343Window Frame · looseEMERGENCY EXIT WINDOW FRAME LOOSE. SECURED WINDOW FRAME.SDR UALA2013040902408Exciter · faultyENGINE NR 2 DID NOT START ON IGN NR 2 COMPLIED WITH MEL 7400Q. PARTS: 671-0073 MR74104 EXCITER - 671-0016 AA134S1 (PLUG) - 671-1324 10-609660-9 (LEAD). REPLACED EXCITER PER AMM, OPS CHECK GOOD.SDR UALA2013040902368Fastener · damagedDAMAGE FOUND ON RT WINGLET IN MID-SPAR AREA LOWER SURFACE. 8TH FASTENER OUTBOARD. SAMC TEXT: DAMAGE ALSO FOUND ON 7TH FASTENER OF MIDSPAR. DAMAGE ALSO FOUND ON FRONT SPAR 14TH FASTENER FROM INBD, DAMAGED FASTENER ON REAR SPAR 18TH FASTENER, DAMAGED FASTENERSDR UALA2013041002441Skin · dentedLEFT INBOARD FLAP UPPER SURFACE HAS AN AREA OF DENTS (APPROX 4) 29"-34" FROM INBOARD EDGE NEAR TRAILING EDGE OF FLAP.SDR UALA2013041002443Bolt · failedNR 3 FRONT BRAKE UNIT HAS SUSTAINED DAMAGE FROM BROKEN WHEEL TIE BOLT. REPLACED BRAKE UNIT.SDR UALA2013040802308Idg · failedEICAS MESSAGE, RIGHT GENERATOR DRIVE DISPLAYED. GENERATOR DRIVE DISCONNECTED. FOUND INTERNAL FAILURE OF IDG, REMOVED AND REPLACED IAW AMM. PERFORMED OPS TEST IAW AMM 24-11-00 STEP 6 AND RESERVICED IDG. NO DEFECTS NOTED.SDR UALA2013040802312Warning System · false activationWINDOW EICAS MSG DISPLAYED POSITION 3(1-L FWD,2=L SIDE,3= R FWD,4=R SIDE).INOP LIGHT ILLUM. INOP LIGHT DID NOT EXTINGUISH WHEN SWITCH WAS RECYCLED TO OFF THEN ON. FRM 30 41 02 -. CREW COMMENTS: CLIMBING THRU FL280 R FWD WINDOW HEAT INOP CHRONIC RAN C LIST,SDR UALA2013040802310Control Panel · faultyPWS INOP LIGHT DOES NOT TEST. REPLACED WX RADAR CONT PANEL, OPS CHECK NORMAL.SDR UALA2013040902370Toilet · failedLAVATORY ISSUES, FLT DIVERTED. LEFT REAR INBD DISABLED TOILET WAS INOPERATIVE AND BLOCKED. ALL OTHER TOILETS OPERATED OK AND TANKS BOTH SHOWED LESS THAN HALF FULL. CLEARED BLOCKAGE FROM TOILET. REPLACED TOILET SEAT ASSEMBLY AND CARRIED OUT LEAK CHECKS SDR UALA2013040802309Warning Light · false activationEIGHT HOURS INTO FLIGHT, STATUS LIGHTS LT ENG EEC C1-L ENG A-O VALVE DISPLAYED. PERFORMED AMM FIM TASK 73 -21-00. NO PROBLEMS FOUND. OK TO CONTINUE.SDR UALA2013040802311Cover · missingENGINE BOTTLE NR 2 DISCHARGE LIGHT COVER IS MISSING. REPLACED COVER, ALL OPS NOW NORMAL.SDR UALA2013040502266Connector · damagedWIRE EXPOSED PIGTAIL POSITION P51. REPAIRED PIGTAIL P51 PLUG BACK SHELL, OPS OKAY.SDR UALA2013040802333Unknown · malfunctionedPAX VIDEO AND ENT SYSTEM WHOLE AIRCRAFT INOP ENTERTAINMENT SYSTEM SCREEN FROZEN AND SOMETIMES IT KEEPS REBOOTING. CB P11 T34 PULLED AND COLLARED REF MEL PROCEDURES FOR ENTERTAINMENT SYSTEM DEACTIVATION. RESTORED ACFT TO ORIGINAL CONFIG FOR MEL 2520HY (C-B T3SDR UALA2013040802307Probe · faultyF/O ALTIMETER 120 FT LOWER THAN CAPT ALTIMETER AT FL300. PRESSURIZED PITOT STATIC SYSTEM IAW AMM. FOUND CAPT PITOT UPPER PROBE AT FAULT. REMOVED AND REPLACED IAW AMM, ALL OPS GOOD. NO LEAKS OR FAULTS NOTED.SDR UALA2013040502285Oven · malfunctionedOVEN 110 SMOKES. REMOVED AND REPLACED OVEN AT POS. 110, FUNCTION TESTED ALL OKAY.SDR UALA2013040502271Wire Harness · wornELECTRIC WIRE HARNESS INSULATION WORN AT P62. REPLACED PIGTAIL AT P62. OPS CHECKED WITH CART CONTROLLER TESTER, OPS CHECKED GOOD.SDR UALA2013040502265Valve · failedEQUIPMENT COOLING 'VALVE' LIGHT ILLUMINATED. 'STBY' SELECTED & 'VALVE' LIGHT REMAINED ILLUMINATED. FOUND FORWARD OVERBOARD VALVE UNSERVICEABLE. REPLACED VALVE PER MM 21-23-08.SDR UALA2013040502286B-Nut · leakingCREW O2 READS LOW, 820 PSI. FOUND SMALL LEAK ON SECOND OBSERVER O2 BOX HOSE B-NUT, SECURED, LEAK CK PER MM. NO LEAK. REPLACED CREW O2 BOTTLE PER MM. PRESSURE 1850 PSI.SDR UALA2013040502284Circuit Card · malfunctionedSTATUS MESSAGE LT ENG FIRE LOOP 2. INSPECTED LT ENG LOOP 2. NO FAULTS NOTED. PERFORMED FIRE LOOP TEST. UNABLE TO DUPLICATE. PROBLEM REOCCURED. REMOVED AND REPLACED M682 CARD PER AMM 26-11- 02 AND TROUBLESHOT PER FIM 26-11-00 FIG 104. NO EICAS MSDR UALA2013040502267Flashlight · inoperativeEMERGENCY TORCH AT LEFT OVERWING POSITION HAS BROKEN SEAL AND LED IS NOT FLASHING. LEFT OVERWING EMERGENCY FLASHLIGHT DEFERRED IAW MEL. REPLACED AS REQUIRED PER MM 25-00.SDR UALA2013040502269Smoke Detector · faultyEICAS MESSAGE - FWD SMOKE DET 1. FORWARD SMOKE DETECTOR NR 1 REPLACED AND OP CHECK OKAY.SDR UALA2013040502268O-Ring · cutCENTER SYSTEM HYDRAULIC RESERVOIR READS .09 ON EICAS. TROUBLESHOT FOUND HYD LEAK AT NR 10 SPOILER ACTUATOR FILTER HOUSING CAP. FOUND O-RING CUT. REPLACED O-RING IAW MM 20-10-19. RESERVICED CTR HYD SYSTEM. LEAK AND OPS CHECKED GOOD.SDR UALA2013040502270Fitting · leakingADP HAS A LEAKING HYD FITTING. TIGHTENED FITTING HALF A TURN. RAN ADP FOR 5 MIN NO LEAKAGE NOTED.SDR UALA2013040302179Satcom · faultyNO COMM DISPLAYED ON ACARS DISPLAY UNIT OVER OCEAN, ACARS SENDS OK IN VHF RANGE. ACCOMPLISH CHRONIC REVIEW. PLACARD SATCOM DUE TO HISTORY PER 2325A, C-B'S COLLARED. REMOVED AND REPLACED SAT DATA UNIT IAW AMM. OPS CHECK GOOD REF 23-25-00. SEE 8262003 FOR PSDR UALA2013040302178Pump · failedFUEL CONFIGURATION LIGHT ON DURING CRUISE. ALL PUMPS ON. NO LIGHTS. PERFORMED FUEL PROCESSOR BITE FOUND FAULTS RM DENS SENSOR FAILURE A01, AND RM DENS SENSOR OPEN AT SPAR A01. VERIFIED MFQ OF RT AND LT TANKS TO BE WITHIN LIMITS VIA STICK READINGS AND PER FSDR UALA2013040202116Motor · unknownHYDRAULIC MOTOR GENERATOR, INOPERATIVE AND DEACTIVATED. HMG REACTIVATED. OPS CHECKED GOOD.SDR UALA2013040202121Oxygen Bottle · leakingCREW O2 BELOW CHECK LIMITS, BOTTLE LEAKS. INSTALLED SERVICEABLE CREW O2 BOTTLE REF GMM 07-55-20 AND 11-35-20. CREW BOTTLE OPS AND LEAK CHECKS GOOD. VERIFIED O2 BOTTLE VALVE FULL OPEN.SDR UALA2013040202137Hydraulic Line · burstHYD LEAK BY RIGHT MAIN GEAR. FOUND HOSE BUSTED FOR RIGHT MAIN GEAR DOWNLOCK ACTUATOR SYS. ORIG PART NIS FRA. INSTALLED TEMPLINE PART 181-1333 FROM HYD LINE SPLICE KIT. OPS AND LEAK OK. CF ITEM FOR PERMANENT REPAIR. REMOVED AND REPLACED HYDRAULIC LINE PERSDR UALA2013040202128Wire · failedP52 PIGTAIL SMOKING AND VERY HOT. ISOLATED BY PULLING CIRCUIT BREAKER AND DISCONNECTED PIGTAIL. SMOKE STOPPED AND PIGTAIL COOLED. NO ADDITIONAL ISSUES NOTED ALL LIGHTS OPERATING & GALLEY SYS NORMAL. SMOKE IN CABIN COND INSP ACCOMPL ACC AMM 05-51-56. CARTSDR UALA2013040202115Cover · dislodgedEMERGENCY EXIT SIGN COVER BETWEEN FIRST AND ECONOMY CAME OFF. COVER SIGN FIXED.SDR UALA2013040202136Indicator · trippedEICAS MESSAGE FOR T/E FLAP DISAGREE DISPLAYED, TRAILING EDGE LIGHT ILLUMINATED, WHEN ANY T/E FLAP POSITION SELECTED. FLAPS FAIL TO MOVE TO SELECTED POSITION. WHEN SELECTING F15 EWR FLAPS ONLY WENT 5 PERFORMED FIM TASK 27-51- 00-101 FIG 105. FOUND OVERLOAD
Back to Boeing 767-322