Boeing 767-332
Service difficulty reports · 11,959
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015102006452Skin · crackedLT WING TIP STR 9.5 HAS CRACK INDICATIONS. REPAIRED.SDR DALA2015102006352Fuse · blownEMERGENCY LIGHTS FROM ROW 12 TO CENTER LAVS ARE INOPERATIVE ON BOTH SIDES. MAINTENANCE POWER PACK WITH BLOWN FUSE, FOUND SHORT TO GROUND AT SEAT 15 LEFT AND REPINNED PLUG AT SEAT 16 LEFT. SYSTEM OPERATION IS NORMAL.SDR DALA2015102006351Connector · damagedEMERGENCY LIGHT AT SEAT 30 RT SIDE ARE INOPERATIVE. MAINTENANCE FOUND PIN PULLED OUT OF PLUG AND REPINNED. SYSTEM OPERATION IS NORMAL.SDR DALA2015101606353Skin · crackedDURING C-CK, REWORK OF LOWER WING SKIN. GROUP A FASTENER HOLES. STG L 9.5/NDT, STEP 3C. HFEC. FOUND CRACK INDICATION OF HOLES 1 AND 2. REPAIRED IAW AMDS 5724-01010-03B, JOB 006-001, STEP 3D, NO FURTHER CRACK INDICATION.SDR DALA2015101506317Failsafe · damagedDO OPEN HOLE AND SURFACE INSPECTIONS, AND REMOVE DAMAGE FROM RT FAILSAFE STRAP IAW SB 767-53A0100, REV 3, PARA 3.B. STEPS 15 THRU 17. TREATED AND PAINTED REPAIR.SDR DALA2015101906316Connector · unsecureSEAT 31A EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE SECURED SEAT CONNECTOR AT 31A, SYSTEM OPS NORMAL.SDR DALA2015100806009Support · damagedRIGHT WING OTBD T/E FLAP, THREE HOLES ON NR 7 SUPPORT 1-2-3 BEAM FASTNER HOLES HAS TOOLING DAMAGE. REPAIRED IAW ERA 539808-14.SDR DALA2015100606010Frame · crackedTAIL COMPARTMENT, DURING HFEC INSPECTION OF THE RT SIDE BS 1809.5 BULKHEAD OUTER FRAME CRACKED. REPAIRED IAW ERA 539816-14AD.SDR DALA2015100706008Charger · inoperativeAFT LEFT EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE CHARGER AT ROW 39FG. SYSTEM OPS NORMAL.SDR DALA2015100105910Angle · crackedAT C-CHECK, BS 1809, RT OF HORIZONTAL ANGLE WL 257, BL 28, CRACKED AT FASTENER HOLE. ANGLE REPAIRED IAW SRM 53-80-08, REPAIR 10.SDR DALA2015092905911Battery Pack · inoperativeDURING SERVICE CHECK, FOUND EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK. SYS OPS NORMAL.SDR DALA2015093005909Connector · disconnectedEMERGENCY LIGHTS AT SEAT 36F ARE INOPERATIVE. MAINTENANCE CONNECTED THE CONNECTOR. SYSTEM OPS NORMAL.SDR DALA2015092305908Battery Pack · inoperativeDURING SERVICE CHECK FOUND LT SIDE OF OVERHEAD EMERGENCY LIGHTS FROM ROW 17-31 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK. SYSTEM OPS IS NORMAL.SDR HALA2015091700194Warning Message · false activationRUDDER RATIO EICAS AFTER ENGINE START. ACCOMPLISHED FIM 27-21-804, NO FAULTS NOTED; STARTED ENGINE AT GATE; NO EICAS MSG OR RUDDER RATIO LIGHT; OK FOR SERVICE.SDR DALA2015091205677Structure · crackedLEFT HORIZONTAL INNER CHORD CRACKED OUT OF FASTENER, BS 1809, REPAIRED IAW SRM 53-80-08.SDR DALA2015091005676Power Supply · inoperativeAFT GALLEY EMERGENCY RECESSED LIGHT, PILOTS SIDE, ARE INOPERATIVE. REPLACED M739 CEILING LIGHT POWER SUPPLY. SYSTEM OPS IS NORMAL.SDR HALA2015090600190Radar · malfunctionedWEATHER FAIL MESSAGE ON WEATHER RADAR SCREEN, WITH LOSS OF WEATHER DATA. RESET A/C POWER. WEATHER RADAR, OPS CHECK OK IAW MM 34-43-00.SDR HALA2015082900176Carriage · damagedT/E FLAP DISAGREE EICAS MESSAGE. FOUND RT OTBD FLAP INBD CARRIAGE JOINT 9 INNER PIN PULLED OUT & BENT, INSPECTED AREA & REPLACED INNER & OUTER PINS AT JOINT 9 IAW AMM 27-51-20. ACCOMPLISHED E105-594-INI. VISUALLY INSPECTED LT AND RT WING OTBD FLAP LINKAGE SDR HALA2015082500170Warning Message · false activationDURING CLIMB, C HYD DEM PUMP EICAS MESSAGE CAME ON. CENTER AIR SWITCH WAS IN AUTO, MOVED SWITCHED TO ON, SAME MSG. FOUND CENTER ISOLATION VALVE IN THE CLOSED POSITION. OPENED CENTER ISOLATION VALVE, OPS CHECKED GOOD. CHECKED HYDRAULIC SYSTEM IAW AMM 29-11-00SDR DALA2015082305237Electrical Box · contaminatedF/A REPORTED ELECTRICAL ODOR IN FIRST CLASS NEAR SEAT 4AB. TROUBLESHOT ENTIRE FIRST CLASS SECTION FOR ELECTRICAL ODOR, NONE FOUND. SUSPECT PASSENGER CHARGING UNIT. REPLACED VIDEO SEAT ELECTRIC BOX UNDER ROW 3A/D DUE TO EVIDENCE OF LIQUID SPILLAGE ON UNIT. SDR DALA2015082005239Battery Pack · inoperativeDURING PDC INSPECTION FOUND EMERGENCY LIGHTS INOPERATIVE FROM ROW 32 UP TO LAST. MAINTENANCE REPLACED BATTERY PACK AND SLADE CHARGER. SYSTEM OPERATION IS NORMAL.SDR DALA2015082705238Lamp · inoperativeEMERGENCY SEAT MOUNTED LIGHT DAMAGED AT SEAT 12B. REPLACED BUMPER, SHROUD AND REPLACED THE LAMP. SYSTEM OPS NORMAL.SDR DALA2015081505236Skin · puncturedFUSELAGE PUNCTURED 34 INCHES AFT OF L1 DOOR CUTOUT. SKIN REPAIRED IAW ERA 538496-14.SDR HALA2015080600154Cap · missingAPU OIL CAP MISSING. REPLACED OIL CAP IAW AMM 49-00-00, NO LEAKS NOTED OK TO CONTINUE.SDR HALA2015073100145Slide · unwanted deploySLIDE DOOR BLOWN AT R1 DOOR. MAIN ENTRY DOOR SLIDES PASSSENGER CONFIGURATION. INSTALLED R1 DOOR SLIDE IAW TC 25-035-51. OPS CHECKED GOOD, OK FOR SERVICE.SDR DALA2015080404795Receiver · odorPERFORMED AN AIR TURNBACK DUE TO AN ELECTRICAL BURNING ODOR THROUGHOUT THE ACFT. FOUND CIRCUIT BREAKER POSITION F6, LEFT ADF, WAS TRIPPED. VERIFIED THE ADF RECEIVER AS THE CAUSE. REPLACED THE LT ADF RECEIVER IAW AMM 34-57. INSPECTED ACFT CARGO BIN AND E/E SDR DALA2015072704660Light · inoperativeEMERGENCY EXIT SIGN ABOVE COKCPIT DOOR IS INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND BATTERY. SYSTEM OPS NORMAL.SDR DALA2015072704659Charger · inoperativeON SERVICE CHECK, FOUND EMERGENCY LIGHTS FROM SEATS 31 INOPERATIVE. MAINTENENCE REPLACED THE BATTERY AND CHARGER. SYSTEM OPS NORMAL.SDR DALA2015072104575Light · inoperativeEMERGENCY LIGHTS AT SEAT 1A ARE INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR DALA2015072804797Spring · weakEMERGENCY LIGHT SWITCH GUARD, SWITCH SPRING IS WEAK. REPLACED LIGHT SWITCH GUARD. SYSTEM OPERATION IS NORMAL.SDR DALA2015072704661Connector · disconnectedEMERGENCY LIGHTS AT 17B ARE INOPERATIVE. MAINTENANCE FOUND DISCONNECTED FROM CONNECTOR BEHIND SEAT LEG. MAINTENANCE RECONNECTED AND SECURED WIRING SYSTEM, OPS NORMAL.SDR DALA2015072904796Skin · damagedACFT SKIN DAMAGED AT BS 742. STRINGER 36R ACROSS 2 FASTENERS BY LAP SEAM REPAIRED IAW SRM 53-00-01.SDR DALA2015071404576Fuse · inoperativeEMERGENCY LIGHT AND AFT EXIT SIGN AT L2 ARE INOPERATIVE. MAINTENANCE REPLACED FUSE 4 IN CHARGER M739. SYSTEM OPERATION IS NORMAL.SDR HALA2015070600132Circuit Card · unknownWHILE PERFORMING MCDP TEST 40, DISCOVERED RT AURAL WARNING SYSTEM INOPERATIVE T/S TO CARD M619. RT SIREN, OWL MODULE. R & R CARD, OPS CHECKED GOOD IAW AMM 31-51-04.SDR DALA2015070404188Structure · crackedVERIFIED CRACK ON NR 2 ENGINE PYLON, INBD SIDE, ADJ TO T/R. REPAIRED IAW ERA537382-14.SDR DALA2015061703949Wire · looseOVERHEAD PANEL EMERGENCY LIGHTS WIRE IS LOOSE. MAINTENACE RESECURED WIRE. SYS OPERATION IS NORMAL.SDR DALA2015060903950Filter · not reportedTHE CREW SHUTDOWN RT ENGINE IAW QRH DUE TO LOSS OF FUEL FROM RT TANK. CREW ALSO REPORTED A RT HYDRAULIC EICAS MESSAGE. REPLACED RT ENGINE FUEL FILTER. SYSTEM OPERATION IS NORMAL.SDR DALA2015060803691Skin · puncturedFUSELAGE HAS PUNCTURE DAMAGE/HOLE AT FS 331 - FS 337 BETWEEN S-31R AND S-32R. REPAIRED IAW ERA 536785-14. LP 7122848.SDR DALA2015060803692Connector · unsecureFOUND SEAT 36F EMERGENCY LIGHT NOT ILLUMINATED. RESEATED EMERGENCY LIGHT CONNECTOR. SYSTEM OPERATION IS NORMAL.SDR DALA2015060503690Stringer · crackedLEFT WING STRINGER L 6.5 HAS CRACK INDICATIONS IN HOLE NR 1 AND HOLE NR 2. REPAIRED IAW PRI 536622-14.SDR DALA2015060303584Skin · crackedENGINE NR 2 PYLON INBD SIDE ACCESS 446BL CUT OUT DOUBLER UPPER SIDE IS CRACKED. REPAIRED IAW SRM 54-53-01.SDR DALA201618560196Skin · damagedINSPECTED IAW SB 767-57-010, REV 9, PART 2. REPAIRED IAW SB 767-57-010, REV 9, PARTS 3 THRU 6 AND AA 5724-01010.SDR DALA2015060203585Acm · failedPERFORMED AN AIR TURN BACK, DUE TO STRONG ACRID ODOR REPORTED BY THE FLIGHT CREW IMMEDIATELY AFTER TAKEOFF THEN DISSIPATED. LAVATORY SMOKE DETECTORS WERE GOING OFF AS WELL. OXYGEN MASKS WERE NOT DONNED, AND NO EMERGENCY WAS DECLARED. LANDED OVERWEIGHT WITHSDR DALA2015060203583Ground Wire · looseFOUND CEILING EMERGENCY LIGHT INOPERATIVE AT 40. MAINTENANCE FOUND GROUND WIRE LOOSE AND SECURED. SYSTEM OPERATION IS NORMAL.SDR DALA2015060103569Indicator · odorREPORTED THE CAPTAIN'S VSI BLANKED DURING FLIGHT CAUSING THE COCKPIT TO FILL WITH A STRONG ELECTRICAL ODOR. THE FLIGHT CREW PULLED THE VSI CIRCUIT BREAKER AND CONTINUED TO THEIR DESTINATION. REPLACED CAPTAIN'S VSI IAW AMM 34-22.SDR DALA2015053003568Charger · inoperativeEMERGENCY LIGHTS IN ROW 31FG-41FG ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK CHARGER ASSEMBLY. SYSTEM OPERATION IS NORMAL.SDR DALA2017042703426Skin · corrodedON WALK AROUND FOUND CORRODED HOLE IN FUSELAGE 1" X 1" ON LT FWD SIDE OF SECTION FS 456.0. REPAIRED DOUBLER.SDR DALA2015053103567Light · brokenEMERGENCY LIGHTS ON AISLE 26B ARE BROKEN. REPLACED LIGHT ASSEMBLY. OPERATION IS NORMAL.SDR DALA2017011900491Failsafe · crackedINSPECTION SHOWS CRACK INDICATION RT SIDE FAILSAFE FITTING AND REPAIRED.SDR DALA2017011900489Stringer · crackedLEFT WING 9.5 STRINGER SHOWS CRACK INDICATION REPAIRS C/W ON N/R 0002. C/W ERA 535954-14.
Back to Boeing 767-332