What was found
DURING CLIMB, C HYD DEM PUMP EICAS MESSAGE CAME ON. CENTER AIR SWITCH WAS IN AUTO, MOVED SWITCHED TO ON, SAME MSG. FOUND CENTER ISOLATION VALVE IN THE CLOSED POSITION. OPENED CENTER ISOLATION VALVE, OPS CHECKED GOOD. CHECKED HYDRAULIC SYSTEM IAW AMM 29-11-00. OPS CHECKED GOOD. NO DEFECTS NOTED, OK FOR SERVICE.