SDR DALA1246711607Charger · inoperativeDURING DRC, FOUND RIGHT EMERGENCY ESCAPE SQUIB TEST 1 WILL NOT TEST. TROUBLESHOT PER FIM 25-65. FOUND FAULTY BATTERY PACK. DISARMED OFFWING ESCAPE SYS IAW B767-300 AMM 25-65. REPLACED BATTERY CHARGER IAW AMM 25-65. REARMED OFF-WING ESCAPE SYSIAW AMM 25-65SDR DALA2015082707893Skin · crackedCRACK AT BS 687, STRINGER 36R AT CARRY THOUGH HOLE, RT AIRFONE BLANKING PLATE, 1/8TH INCH CRACK.SDR DALA1245820124Skin · crackedSKIN CRACKED ONE EIGTH INCH CRACK RT AIRFONE BLANKING PLATE INST STA 687 STR 36R AT CARRY THRU HOLE LOC MARKED REF ERA 389647-14 REV A. REPAIRED PER SRM B767-300 53-00-01 REPAIR 12.SDR DALA1245760174Connector · brokenEMERGENCY ESCAPE PATH LIGHTS AT SEAT 20 GH ARE INOPERATIVE. MAINTENANCE REPLACED THE PIN CONNECTION AT SIDEWALL PER SPWM. OPS CHECKED GOOD.SDR DALA1245750172Light · inoperativeDURING L/O INSPECTION, FOUND RT WING NR 2 EMERGENCY ESCAPE SLIDE LIGHT INOPERATIVE. MAINTENANCE FOUNDS REFLECTOR BAD AND REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1245770196Socket · looseEMERGENCY LIGHTS LEFT 3RD AND 4TH ARE INOPERATIVE. MAINTENANCE SECURED LAMP SOCKET AT BOTH POSITIONS. SYSTEM CHECKED NORMAL.SDR DALA1245570185Pin · brokenEMERGENCY LIGHTS AT 30B ARE INOPERATIVE. MAINTENANCE REPLACED A BROKEN PIN. SYSTEM OPERATION IS NORMAL.SDR DALA1244761611Charger · inoperativeAFT LEFT ENTRY DOOR LOWER FWD EMERGENCY LIGHT NOT WORKING. REPLACED CHARGER PER AMM 33-51. LIGHT NOW CHECKED GOOD.SDR DALA1244740196Power Supply · inoperativeDURING DRC, FOUND EXTERIOR EMERGENCY LIGHT OUT OAT LET SIDE AFT OF TRAILING EDGE. THE POWER SUPPLY UNIT WAS REPLACED PER AMM. SYSTEM OPERATION IS NORMAL.SDR HALA2012080500190Circuit Card · faultyRIGHT FIRE LOOP MESSAGE DISPLAYED DURING CLIMB OUT AT APPROXIMATELY 9,200 FT, WENT OUT ON ITS OWN AT 24,000 FT. R & R PRINTED CIRCUIT CARD IAW AMM 26-10-01. ENGINE RUN OPS CHECKED OK ON GROUND. OK FOR SERVICE. ACCOMPLISHED FIM 26-11. FAULT TREE 804 WIRINSDR HALA2012080400191Fire Warning · false activationRIGHT FIRE LOOP NR 2, MESSAGE DISPLAYED ON CLIMB OUT FROM 8000'-16000'. WENT OUT ON IT'S OWN. ALL OTHER INDICATIONS NORMAL. TROUBLESHOOTING FOUND TWO CLAMPS ON INTERMEDIATE BLEED AIR DUCT AND CHECK VALVE LOOSE. ALSO FOUND ONE CLAMP ON TURBINE CASE COOLING SDR DALA1244671707Power Supply · inoperativeDURING DRC, FOUND SEAT PATH EMERGENCY LIGHTS INOPERATIVE AT 21FG TO 31FG. TROUBLESHOT AND FOUND POWER SUPPLY M737 INOPERATIVE. REPLACED PER AMM 33-51. OPS CHECKED GOOD. OK FOR SERVICE.SDR HALA2012073000186Idg · malfunctionedRIGHT ENG "FIELD OFF" LEFT ILLUMINATED ON P61 PANEL. R & R NR 2 RIGHT ENGINE IDG REF AMM 24-11-01. RAN ENG 5 MIN ID L/E OPS CHECKED GOOD, DISCONNECTED IDG - CONNECTED IDG - RAN ENG 5 MIN IDLE, OPS - LEAK CHECKED GOOD - OK FOR SERVICE.SDR HALA2012072700185Terminal · shortedETOPS SIGNIFICANT SYSTEM, UPON APU START, ARCING WAS NOTICED AT APU BATTERY GROUNDING STUDS/LUGS. REPLACED GROUND LUG IAW SWPM 20-30-11. R & R APU BATTERY GROUND BRACKET AND STUD ASSY, SECURITY CHECKED GOOD.SDR HALA2012072700184Ground Stud · arcedETOPS SIGNIFICANT SYS - UPON APU START, ARCING WAS NOTICED AT APU BATTERY GROUNDING STUDS/LUGS. REPLACED GROUND LUG IAW SWPM 20-30-11. R & R APU BATTERY GROUND BRACKET AND STUD ASSY SECURITY CK GOOD.SDR RYNA201207250031Connector · looseFOUND EMERGENCY LIGHTING WIRE HARNESS CONNECTOR LOOSE UNDER SEAT 26B AND 25F. RECONNECTED CONNECTOR AND SECURED WIRE HARNESS UNDER SEAT 26B AND25F AND EMERGENCY LIGHTING OPS CHECK GOOD PER MM 33-51-00.SDR HALA2012072400180Engine · power lossON INITIAL THROTTLE UP FOR TAKE OFF PUSHED THROTTLES UP TO APPROX 23 PERCENT N1 RT ENG SPOOLED UP NORMAL, LEFT ENG LAGGED APPROX 2-3 SECONDS BEFORE SPOOLING UP FOR NORMAL THROTTLE POSITION. ACCOMPLISHED TEST NR 4 - GROUND TEST FOR TAKEOFF POWER, ACCELERATION SDR HALA2012072400179Circuit Card · malfunctionedRT FIRE LOOP 2 STATUS MESSAGE DISPLAYED AFTER TAKE OFF UNTIL APPROX 12000 FT AGL, ALL OTHER INDICATIONS NORMAL. ACCOMPLISHED FIM 26-11-00/101, FIG 104, RESISTANCE CHECK OF NR 2 ENG FIRE DETECTION SYS, LP 2 IS OK. R & R M684 FIRE DETECTION CARD AS PREVENTATIVSDR HALA2012072400178Circuit Card · malfunctionedRT FIRE LOOP 2 STATUS MESSAGE DISPLAYED AFTER TAKE OFF UNTIL APPROX 12000 FT AGL, ALL OTHER INDICATIONS NORMAL. ACCOMPLISHED FIM 26-11-00/101, FIG 104 RESISTANCE CHECK OF NR 2 ENG FIRE DETECTION SYS, LP 2 IS OK. R & R M684 FIRE DETECTION CARD AS PREVENTATIVSDR DALA1242150198Slide · no testDURING PDC DL91 FOUND SPOILER SQUIB LIGHT AND SLIDE NOT TESTING ON RIGHT SIDE ON PANEL. TROUBLESHOT PER FIM 25-65-00-101, BATTERY REMOVED. ELECTRICAL CONNECTIONS CLEANED AND REINSTALLED. SYSTEM TESTS NORMAL.SDR DALA1242340195Contact · dirtyDURING DRC, FOUND RT EMERGENCY LIGHT FWD OF AFT CARGO DOOR INOPERATIVE. MAINTENACE CHECK LIGHT ASSY AND FND DUTY SOCKET CONTACT AND CLEANED. SYSTEM OPERATES NORMAL.SDR HALA2012071700175Warning Light · false activationAFTER RT ENGINE START, RT GENERATOR OFF EICAS. RESET IAW QRH. RAN RT ENGINE, GENERATOR OPERATED NORMALLY. OK FOR SERVICE.SDR DALA1241821403Unknown · odorFLIGHT ATTENDANT DETECTED AN INTERMITTENT ELECTRICAL ODOR. NO SMOKE NEAR 19E AND STORAGE 735. MAINTENANCE RAN PACKS. PERFORMANED IFE MASTER TEST ALL CABIN LIGHTS ON. NO ELECTRICAL ODOR OR ABNORMALITIES NOTED. OK FOR SERVICE.SDR DALA1242331611Light · inoperativeEMERGENCY LIGHTS ABOVE 1D ARE INOPERATIVE.SDR HALA2012071400174Fire Warning · false activationRIGHT ENGINE FIRE LP 2 STATUS MESSAGE DISPLAYED AFTER TAKEOFF UNTIL REACHING APPROX 9000 FT. MESSAGE WENT OUT AND DID NOT REAPPEAR FOR THE REMAINDER OF THE FLIGHT. TS IAW FIM 26-11-00-101, FIG 104 AND 106. INSPECTED LOOPS AND VERIFIED SECURITY OF CONNECTIONSDR DALA1241801705Wire · looseDURING PDC, FOUND EMERGENCY PATHWAY LIGHT OUT AT SEAT 26F. MAINTENANCE REPOSITIONED AND SECURED WIRE PER AMM. SYSTEM OPERATION IS NORMAL.SDR DALA1241630186Wire Harness · inoperativeEMERGENCY ESCAPE PATH LIGHTS AT SEAT 2B ARE INOPERATIVE. WIRE HARNESS REPLACED. SYSTEM OPERATION IS NORMAL.SDR HALA2012070800168Ground Wire · brokenON CLIMB OUT, RECEIVED STATUS MSG ONLY " AFT EQ EXH FAN 2". TROUBLESHOT IAW FIM 21-26-00, FIG 104, SHEET 1. FOUND WIRES GD1338 AND GD1340 BROKEN AT GROUND TERMINALS. R & R STUDS IAW SWPM 20-30-11. CLEARED MSG. OPS CK GOOD.SDR DALA1240800138Battery Pack · inoperativeFOUND DURING A CHECK EMERGENCY EXIT PATHWAY LIGHTS ROW 35 AFT ARE INOPERATIVE. THE BATTERY PACK REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1240740183Structure · crackedLEFT FWD OUTER CHORD AT BS 1809.5 NEAR THE AFT PRESSURE BULKHEAD WAS FOUND TO HAVE TWO FASTENER HOLES SHOWING CRACKS AND TWO WERE OBLONG. REPAIRS WERE MADE PER ERA 505173-14AD REV ORIG.SDR DALA1620520178Support · corrodedLT & RT INBOARD FLAP. INBOARD AND OUTBOARD SUPPORT CORROSION OR TOOLING DAMAGE.SDR DALA201618280176Support · unknownWING LT & RT INBD FLAP INBD AND OTBD SUPPORT CORROSION OR TOOLING DAMAGE 089397-14.SDR DALA1240810177Wire · brokenEMERGENCY LIGHTS AT SEAT 24FG ARE INOPERATIVE. MAINTENANCE FOUND BROKEN WIRE ON OTBD SEAT. SECURED WIRE. REPLACED PIN ON WIRE PER PM.SDR DALA1240450176Light · inoperativeDURING DRC FOUND EMERGENCY LIGHT PATH LIGHT INOPERATIVE AT SEAT 37G. REPLACED LT ASSEMBLY ILLUMINATED CHECKED OK.SDR DALA1239581607Power Supply · inoperativePOST SLIDE CHANGE FOUND LT AND RT OFF WING ESCAPE SYSTEM POWER SUPPLY BATTERIES DEAD. REMOVED AND REPLACED LT AND RT OFF WING ESCAPE SYSTEM POWER SUPPLIES PER AMM 25-65-17.SDR DALA1238450184Unknown · odorONE HOUR INTO FLIGHT LEFT PACK TEMP EICAS FOLLOWED BY PACK INOPERATIVE. LIGHT ON OVERHEAD PANEL BOTH EXTINGUISHED WITHIN 30 SECONDS WITHOUT ANY CREW ACTION. HOT METAL ODOR IN MID CABIN AT SAME TIME. THE LEFT PACK TEMP CONTROL VALVE WAS REPLACED. SYSTEM OPESDR DALA1238321201Wire · brokenEMERGENCY LIGHTS ON SEAT 31AB U/S WIRING IS BROKEN. MAINTENANCE FOUND LIGHT DISCONNECTED AND RECONNECTED THE CONNECTOR. SYSTEM OPERATIONS IS NORMAL.SDR DALA1237941601Battery Pack · inoperativeEMERGENCY LIGHTS IN SEATS INOPERATIVE RT AND LT SIDES 32 AND AFT. REMOVED AND REPLACED BATTERY PACK IAW AMM 33-51. OPS CHECKED GOOD.SDR RYNA201206150026Battery Pack · dischargedEMERGENCY LIGHTS INOPERATIVE AT ALL PASSENGER SEATS AND LOWER EXIT SIGNS AT ALL DOORS. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACKS AT SEATS 2A, 29A, AND 45G PER AMM 33-51-09. OPERATIONAL CHECKED NORMAL.SDR DALA1237561200Battery Pack · inoperativeEMERGENCY LIGHTS AT SEAT 6GF-20GF ARE INOPERATIVE. THE BATTERY PACK AND FUSE M9011 WERE REPLACED. SYSTEM OPS NORMAL.SDR DALA1237550177Connector · brokenEMERGENCY LIGHT AT SEAT 28B IS INOPERATIVE. MAINTENANCE FOUND THE CONNECTOR BROKE AT SEAT HARNESS 28A AND SPLICED IN NEW CONNECTION. SYSTEM OPERATION IS NORMAL.SDR DALA1237101603Pump · inoperativeLT CENTER FUEL PUMP INOPERATIVE.SDR DALA1236711607Fuse · inoperativeDURING PDC, FOUND EMERGENCY PATH LIGHTS 24GF-32GF INOPERATIVE. REMOVED AND REPLACED FUSE AT BATTERY CHARGER M732. INSTALLED BATTERY AND ALLOWED TO CHARGE. OPS CHECKED NORMAL. OK FOR SERVICE.SDR DALA1236701200Fuse · inoperativeDURING DRC, FOUND EMERGENCY PATH LIGHTS AT SEAT 6GF AND 16GF TO 20GF INOPERATIVE. THE FUSE WAS REPLACED ON BATTERY CHARGER M9011. OPS CHKS GOOD.SDR DALA1235780121Fitting · crackedRT FUSELAGE UNDERWING LONGERON FITTING IS CRACKED AND REPLACED PER EA 01-499898-03 ME-04 REV ORIG.SDR DALA1235770121Fitting · crackedLT FUSELAGE UNDERWING LONGERON FITTING IS CRACKED AND REPLACED PER EA 01-499898-03 ME-03 REV ORIG.SDR DALA1235810190Battery Pack · dischargedDURING CHECK FOUND EMERGENCY LIGHTS DIM FROM SEAT 32 AFT. MAINTENANCE REPLACED THE BATTERY PACK AND CHARGER M9010 AT SEAT 39G. SYSTEM OPERATION IS NORMAL.SDR HALA2012060300156Blade · damagedNR 2 ENGINE BOROSCOPE INDICATES ENGINE DAMAGED. FOUND FIRST STAGE HPT BLADES DAMAGED BEYOND AMM LIMITS. CHANGED NR 2 ENGINE. LEAK CHECK & OPS CHECK GOOD. OK FOR SERVICE.SDR DALA1235540182Charger · inoperativeSECTION OF EMERGENCY LIGHTS ARE INOPERATIVE. MAINTENANCE REPLACED THE CHARGER BASE AT M7361P11/F2. OPS CHECKED GOOD.SDR DALA1235470138Charger · inoperativeEMERGENCY PATCH LIGHTING ROW 35 ON INOPERATIVE. REPLACED BATTERY CHARGER ASSY M9010 PER 767 AMM 33. OPS CHECK NORMAL OK FOR SERVICE.
Back to Boeing 767-332