Boeing 767-332
Service difficulty reports · 11,959
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767332' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1204910139Skin · bulgedRT WING 11 L/E SLAT WEDGE SKIN FOUND BULGED. HOT METAL BOND REPAIR PERFORMED ON AREA AS PER SRM 57-43-02 REPAIR 1 FIGURE 201 AND SRM 51-70-10 REPAIR 4 FIG 202.SDR DALA1204881707Fairing · damagedLT WING I/B AILERON L/E FAIRING HAS COMPOSITE DAMAGE. COMPOSITE REPAIR CARRIED OUT AS PER B767-300 SRM 57-60-01 REPAIR 1 AND SRM 51-70-05 PAR 5.G.SDR DALA1204871707Fairing · crackedI/B AILREON L/E FAIRING CRACKED. COMPOSITE REPAIR CARRIED OUT AS PER B767-300 SRM 57-60-01 REPAIR 1 AND SRM 51-70-05 PARAGRAPH 5.G.SDR DALA1204860139Skin · corrodedCORROSION FOUND AFT CARGO INTERIOR FUSELAGE SKIN AT FS 1077 STRINGER 39L.SDR DALA1204850139Skin · corrodedCORROSION FOUND AFT CARGO INTERIOR SKIN AREA FS STA 1077 FROM STRINGER 39L TO 39R. CP53-151-02I/CP53-152-02I (NRC 51757)SDR DALA1204840139Fairing · crackedDURING HMV 3 VISIT FOUND RT WING INBOARD MAIN FLAP OUTBOARD LEADING EGDE FAIRING CRACKED. COMPOSITE REPAIR CARRIED OUT AS PER B767-300 SRM 57-53-01 REPAIR 1 AND SRM 51-70-05 PAR 5.A(1).SDR DALA1207000182Strap · crackedFAIL SAFE STRAP FAILED U/T INSPECTION AT LT BS 955 REPAIR REQUIRED. BS 955 REAR SPAR BULKHEAD LT FAIL SAFE STRAP REPAIRED PER ERA 499093-14AD REV 0 09FEB2012 (ERA 499093-14AD).SDR DALA1206371708Light · inoperativeEMERGENCY LIGHT AT SEAT 25F IS INOPERATIVE. THE LIGHT ASSY WAS REPLACED. SYSTEM OPERATION IS NORMAL.SDR DALA1204970125Battery Pack · dischargedEMERGENCY EXIT LIGHT AFT R3 ARE INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA1204010192Strap · crackedHMV2 FAIL SAFE STRAP CRACKED STA 995 LT SIDE OPN 8701AD. REPAIR PER ERA 499083-14AD REV 0.SDR DALA1302241612Battery · inoperativeRT EMERGENCY ESCAPE SLIDE FAILS TEST 1 AND TEST 2 C/A T/S IAW FIM 25-65-00 RT EMERG BATT. REPLACED IAW AMM 25-65-17. OPS CK GOOD. RII TASK C/W PINS VERIFIED REMOVED AND STOWED.SDR DALA1209970139Frame · crackedMAIN DECK BS 903 RBL 89 FRAME CRACKED. REPAIRED PER ERA 499047-14AD REV ORIG SECT 1.SDR DALA1209840139Frame · crackedMAIN DECK BS 903 LBL 89 FRAME CRACKED. REPAIRED PER ERA 499046-14AD REV ORIG.SDR DALA1209490139Frame · crackedMAIN DECK BS 883 LBL 89 FOUND FRAME CRACKED. REPAIRED PER ERA 499048-14AD REV ORIG SECTION 1.SDR DALA1209430139Frame · crackedMAIN DECK BS 883 RBL 89 FRAME CRACKED. REPAIR ACCOMPLISHED PER ERA 499049-14AD REV ORIG SECTION I.SDR DALA1204961611Terminal · looseMAINTENANCE FOUND EMERGENCY PATH LIGHTS AT SEAT 33AB INOP. SECURED TERMINAL AT SIDEWALL.SDR DALA1204301200Connector · damagedEMERGENCY LIGHTS AT SEAT 30AB ARE INOPERATIVE. MAINTENANCE REPAIRED CONNECTOR. SYSTEM OPERATION IS NORMAL.SDR DALA1203490139Skin · crackedM/D L1 DOOR AFT CUTOUT LWR CORNER SKIN CRACKED. THE SKIN REPAIR AS PER B767-300 SRM 53-10-01 REPAIR 1 FIG 201 CAT B REPAIR.SDR DALA1203500139Floorbeam · crackedCABIN - BS 325 RBL 26-50 FLOORBEAM UPPER CHORD FOUND CORROSION CRACK. THE FLOORBEAM REPAIR AS PER B767-300 SRM 53-00-51 REPAIR 1 FIG 201 CAT A REPAIR.SDR DALA1203340191Pin · backed outEMERGENCY PATH LIGHTS AT 5G ARE INOPERATIVE. MAINTENANCE FOUND A PIN PUSHED BACK ON POWER SUPPLY WIRE AND RESECURED. SYSTEM OPERATION IS NORMAL.SDR DALA1203520139Floorbeam · corrodedM/D STA 1518 LBL 25 FLOORBEAM CORROSION. THE FLOORBEAM REPAIR AS PER B767-300 SRM 53-00-51 REPAIR 1 FIG 201 CAT A REPAIR.SDR DALA1203510139Floorbeam · corrodedM/D STA 1518 BL R25 FLOORBEAM CORROSION. THE FLOORBEAM REPAIR AS PER B767-300 SRM 53-00-51 REPAIR 1 FIG 201 CAT A REPAIR.SDR DALA1203480139Skin · crackedFUSELAGE LT STAB LWR GATE CUTOUT SKIN FOUND CRACKED. REPAIR THE SKIN AS PER B767-300 SRM 53-80-01 REPAIR 3 FIG 201 CAT A REPAIR.SDR DALA1209210171Failsafe · crackedLEFT BS 955 FAIL SAFE FOUND CRACKED DURING ULTRASONIC INSPECTION. OPENSDR DALA1203330185Connector · looseEMERGENCY PATH LIGHTS AT 17A ARE INOPERATIVE. MAINTENANCE FOUND A LOOSE CONNECTION AT 17A AND SECURED. SYSTEM OPS NORMAL.SDR HALA2012011900048Sensor · dirtyETOPS SIGNIFICANT SYS - UNABLE TO REGULATE MID CABIN TEMPERTURE WITH AUTO CONTROL. FLUCTUATED ENTIRELY HOT THEN SMALL ADJUSTMENT CAUSES IT TO SWING EXTREMELY COLD. REQUIRES CONSTANT ADJUST AND STILL CAN NOT CONTROL. CLEANED MID CABIN TEMPERTURE SENSOR INLET SDR DALA1202740185Connector · disconnectedDURING DRC FOUND EMERGENCY PATH LIGHTS AT 20A INOPERATIVE. MAINTENANCE PLUGGED IN CONNECTOR. SYSTEM OPS NORMAL.SDR DALA1202580196Failsafe · crackedCRACK FOUND IN RMLG FAILSAFE DURING ULTRA-SONIC INSPECTION PER SI 01-086393-12AD. REPAIRED PER ERA 499436-14AD.SDR HALA2012011800043Irs · splitETOPS SIGNIFICANT SYS- FMC MESSAGE SPLIT IRS OPERATION LT IRS 034/0.5, CENTER IRS. RT IRS 350/0.6. REMOVED POWER FROM ACFT RE-ESTABLISHED POWER AND ALIGNED TRU'S IAW SUB TASK 34-45-00, 745-075-003 AMM, NO SPLIT NOTED, OPS CHECKED OK.SDR DALA1202271707Floorbeam · corrodedCABIN STA 654+110 RBL 21, FLOORBEAM UPPER CHORD CORROSION. THE FLOORBEAM REPAIR AS PER B767-300 SRM 53-00-51 FIG 201 REPAIR 1.SDR HALA2012011600037Warning Light · false activationETOPS SIGNIFICANT SYS - FWD EQUIPMENT VALVE ON EICAS & OVERHEAD PANEL. TROUBLESHOT PER FIM 21-58-00 FIG 105 NO DEFECTS NOTED. OK FOR SERVICE.SDR HALA2012011600028Eec · malfunctionedETOPS SIGNIFICANT SYS - AFTER ENGINE START, RIGHT EEC INOPERATIVE, LIGHT ILLUMINATED. RESET RT EEC. PERFORMED ENGINE RUN. ALL OPS CHECKED GOOD.SDR HALA2012011500020Warning Light · false activationETOPS SIGNIFICANT SYS - FWD EQUIPMENT VALVE ON EICAS AND OVERHEAD PANEL. TROUBLESHOT IAW FIM 21-58-00, FIG 105. NO DEFECTS NOTED, OK FOR SERVICE.SDR DALA1517300174Fitting · not reportedWINGS DIAGONAL BRACE AFT PITCH LOAD FITTING, LWR WIN IAW EA 01-451812-03.SDR DALA1201840192Strap · crackedFAIL SAFE STRAP-INSP (OPN 8701AD) ULTRASONIC INSP CARRIED OUT ON STA 955 FAIL SAFE STRAP (LT SIDE) & FOUND CRACK INDICATION NRC # 0015 RAISED TO REMOVED AFFECTED FASTENER & CONFIRM CRACK INDICATION AT 2 O`CLOCK & 8 O`CLOCK POSITION. BS 955 REAR SPAR BULKHEAD SDR DALA1201851707Seat Track · corrodedCABIN STA 654+121 TO STA 680 RBL 55 SEAT TRACK CORRODED. FABRICATE AND INSTALL SEAT TRACK PER PRI 499040-14 13JAN12 14:30.SDR DALA1201661706Channel · chafedAFT CARGO DOOR LWR CHANNEL P/N 140T2982-10 FOUND WITH EXISTING REPAIR ANGLE CHAFED & EXCEED LIMITS AS PER SRM. DAMAGED CHANNEL P/N 140T2982-10 REMOVED & REPLACED WITH NEW CHANNEL BY FABRICATION IAW BOEING B767 DWG 140T2982 REV C.SDR DALA1201770176Fuse · openLEFT WING OUTSIDE EMERGENCY EXIT LIGHT INOP ON PDC PER SSM 33-51-01. FOUND FUSE 2 BLOWN ON M736 AND CONTACTS DIRTY ON LIGHT ASSY. REPLACED FUSE AND CLEANED CONTACTS. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPSSDR DALA1201391706Structure · crackedBULK CARGO DOOR PROTECTOR SUPPORT STRUCTURE BETWEEN STA 1395 TO STA 1417 LBL 20.30 TO LBL 24.40 WL 192.43 (FLOORBEAM/MD AREA) DAMAGED (P/N 452T3251-1 INTERCOSTAL P/N 452T3252-2 BRACKET &P/N 452T3288-5 PLATE). REFER TO DRC#0281 INTERCOSTAL BRACKET & PLATE REMOSDR HALA2012011100019Warning Light · false activationETOPS SIGNIFICANT SYS - MX LEVEL EICAS MESSAGE FOR ENGINE EEC LATCHED. PERFORMED TROUBLESHOOTING IAW FIM 767-FIM HWI D633T6A8, FIG 104, SHEET 1, STEP 1 THUR 4. EEC MX MONITOR UNIT BITE PROCEDURES. NO FAULT NOTED, ACFT OK FOR SERVICE.SDR DALA1201331604Wedge · delaminatedNR 6 SLAT WEDGE UPPER SURFACE IS DELAMINATED. REPAIRED PER B767-+300 SRM 57-43-02 REPAIR 1 AND 51-70-10 REPAIR 4 FIG 202.SDR DALA1201321604Skin · delaminatedNR 10 SLAT UPPER SKIN IS DELAMINATED. REPAIRED PER B767-300 SRM 57-43-02 REPAIR 1 AND 51-70-10 REPAIR 4 FIG 202.SDR DALA1201311604Wedge · delaminatedNR 3 SLAT WEDGE UPPER SURFACE DELAMINATED AND REPAIRED PER B767-300 SRM 57-43-02 REPAIR 1 AND 51-70-10 REPAIR FIG 201.SDR DALA1201301604Skin · delaminatedLEFT WING I/B AFT FLAP UPPER SURFACE IS DELAMINATED. REPAIRED PER B767-300 SRM 57-53-01 REPAIR 1 AND 51-70-10 REPAIR 4 FIG 203.SDR DALA1201260190Wire Harness · damagedDURING FLIGHT, SEAT 4G PERSONAL VIDEO MONITOR STARTED SMOKING AND BECAME HOT. DISCONNECTED MONITOR FROM POWER SOURCE AND CAPED AND STOWED CONNECTORS. FOUND MONITOR WITH SPILL AND SDU HARNESS DAMAGED. REPLACED MONITOR AND SDU HARNESS AT 4G. OPS CHECKED NORMASDR DALA1301191705Light · inoperativeSEAT 1A-4A EMERGENCY LIGHT INOPERATIVE. REPAIRED EMERGENCY LIGHTS IAW ERA01-510375-14, REV ORIG. EMERGENCY LIGHTS NOW OPERATE NORMAL.SDR HALA2012010500005Rudder · malfunctionedETOPS SIGNIFICANT SYS - AFTER ENGINE START RUDDER RATIO DISPLAYED ON THE OVERHEAD PANEL AND ON EICAS DISPLAY. RESET LT AND RT RRCM PERFORMED FIM 27-21-00, FIG 104. NO FAULTS NOTED, OK FOR SERVICE.SDR DALA1201050191Wire Harness · defectiveEMERGENCY PATH LIGHTS AT SEAT 38B ARE INOPERATIVE. MTC REPLACED THE HARNESS. SYSTEM OPERATION IS NORMAL.SDR DALA1200541607Unknown · odorEN ROUTE ELECTRICAL SMELL IN AFT GALLEY BY C/B PANEL LEFT OF OVENS. RAN BOTH PACKS AND BOTH GALLEY VENTS FANS NO ELECTRICAL SMELL. PULLED OUT BOTH AFT GALLEY CIRCUIT BREAKER PANELS. NO SMELL OR SIGNS OF ELECTRICAL BURNS. RAN ALL OVENS AND COFFEEMAKERS. WESDR HALA2012010200003Display · malfunctionedETOPS SIGNIFICANT SYS - WEATHER RADAR AND TERRAIN DISPLAY ON F/O NAV DISPLAY DOES NOT GET BRIGHT ENOUGH WHEN NAV INTENSITY IS DIMMED. EHSI TEST OK IAW AMM 34-22-05 & GPWS TEST OK IAW AMM 34-46-00 & WXR TEST OK IAW AMM 34-43-00.
Back to Boeing 767-332