Boeing 767-33A
Service difficulty reports · 1,978
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76733A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '76733A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HALA0700565Bleed Valve · malfunctionedETOPS SIGNIFICANT SYSTEM, R ENG BLEED VALVE CLOSES WHEN LEFT START SELECTOR POSITIONED TO GRND DURING XBLEED START PER AMM 71-00-00-712-021. STARTED BOTH ENGINES. OPS CK OK, COULD NOT DUPLICATE WRITE-UP.SDR HALA0700564Aileron · malfunctionedETOPS SIGNIFICANT SYSTEM, AILERON LOCKOUT 11000 FT 270 ORH NO ACTION. FOLLOWED FIM 27-11-00 FAULT CLEARED ON LSAM. OPS CK OF AILERON GOOD. NO DEFECTS NOTED.SDR HALA0700556Warning Light · false activationETOPS SIGNIFICANT SYSTEM, AFTER ENG SHUT DOWN APU ON LEFT PACK IN AUTO "INOP" LIGHT CAME ON. SELECTED STBY INOP LIGHT WENT OUT. BIT AIR PACK CONTROLLER PER MM 21-53-00 FIG 103. NO FAULTS. OK TO CONTINUE.SDR HALA0700555Unknown · unknownETOPS SIGNIFICANT SYSTEM, "APU FAULT" APU WILL NOT START. T/S PER FIM 49-11-00/101 FIG 103, ECU BITE SHOWED "START ABORTED" AND LRU FAULT "AC START CIRCUIT" APU STARTED NORMALLY SEVERAL TIMES AND ALL TESTS CHECK GOOD PER FIM 49-11-00, "APU FAULT" CLEARED AND SDR HALA0700551Light · malfunctionedEMERGENCY FLOOR LTS ILLUMINATED DURING FLT, WITH NO LOSS OF ELEC POWER. CHECKED OPERATION OF EMERGENCY LIGHT PER FIM 33-51-00. EMERGENCY LIGHTS CHECKED NORMAL. OK FOR SERVICE.SDR HALA0700554Unknown · unknownETOPS SIGNIFICANT SYSTEM, APU PNEUMATIC AIR INOP. BITE CHECK ECU PER AMM 49-11-00. NO FAULTS NOTED. APU STARTED ON FIRST ATTEMPT. OK FOR SERVICE. APU AIR OPS CK GOOD.
SDR HALA0700553Warning Message · false indicationFUEL IND CTR TANK WENT BLANK FUEL IND STATUS MSG DISPLAYED. PERFORMED BITE TEST FUEL QUANTITY PROCESSOR PER FIM 28-41-00, NO FAULTS DISPLAY. FUEL IND CTR TANK NORMAL AT THIS TIME AND NO STATUS MSG DISPLAY.SDR HALA0700543Transceiver · inoperativeETOPS SIGNIFICANT SYSTEM, NR 2 HF RADIO WILL NOT TRANSMIT ON ANY FREQUENCIES ALSO DATA LINK IS INOP. NO SIDE TONE OR TUNING. T/S PER FIM 23-11-00 FIG 103 SYSTEM OPS TEST NORMAL ON GROUND PDX, SFO CONTACTED ON 5547 RESPONSE LOUD AND CLEAR. NO FAULTS ON BITE,SDR HALA0700546Indicator · malfunctionedETOPS SIGNIFICANT SYSTEM, OFF FLAG IN VIEW ON CAPT'S ALTM WITH BOTH NORM AND ALT AIR DATA SW SELECTED. REPLACED CAPT'S ALTIMETER INDICATOR. OPS CK OK PER MM 34-13-01.SDR HALA0700542Actuator · malfunctionedETOPS SIGNIFICANT SYSTEM, SINGLE FUEL CROSSFEED VALVE LGT REMAINED ILLUM WHEN "CLOSE" SELECTED. EICAS MSG "FUEL CROSSFEED" DISPLAYED. REMOVED AND REPLACED FUEL CROSSFEED VALVE ACTUATOR PER AMM 28-22-12. OPS CHECKED GOOD.SDR HALA0700545Warning Light · intermittentETOPS SIGNIFICANT SYSTEM, RIGHT PACK OFF LIGHT DOES NOT COME ON WHEN RIGHT PACK SELECTED OFF. LIGHT TEST OK PACK DOES SHUT DOWN. CYCLED RT PACK SW 3X OPS CHK OK NO DEFECTS NOTED CAN NOT DUPLICATE WRITE UP, OK FOR SVC, RT PACK OPS CHK (NORMAL) OPS CK OK PER ASDR HALA0700533Audio Video Unit · odorELECTRICAL SMOKE ODOR AROUND SEATS 14HJ (NO VISIBLE SMOKE). POWERED OFF ENTERTAINMENT SYSTEM ODOR DIMINISHED. FOUND BAD AVU AT SEAT 14HJ REPLACED AVU AND ORCHESTRATED ENTERTAINMENT SYSTEM OPS CKS NORMAL.SDR HALA0700531Controller · faultedETOPS SIGNIFICANT SYSTEM, RIGHT PACK "INOP LIGHT ON IN AUTO POSITION. FOUND PACK TEMPERATURE CONTROLLER, "CONTROLLER FAULT LIGHT ON." REPLACED RIGHT PACK TEMPERATURE CONTROLLER PER AMM 21-51-14. OPS CHECK GOOD.
SDR HALA0700529Warning Light · false activationETOPS SIGNIFICANT SYSTEM, LT FWD FUEL PUMP EICAS LIGHT ILLUMINATED ON DESCENT. CHECKED AND PERFORMED OPERATIONAL TEST OF THE ENGINE FUEL FEED SYSTEM PER MM 28-22-00-715-001 OF THE LT FWD FUEL PUMP. PUMP OPS CHECK OK. A/C OK FOR SERVICE.SDR HALA0700527Deu · malfunctionedETOPS SIGNIFICANT SYSTEM, LEFT TANK FUEL QUANTITY INDICATOR BLANK. EICAS MSG 'FUEL QTY IND' PRESENT. FUEL QUANTITY BITE TEST SHOWS HARD FAULT CODES '63' AND 'D5'. CLEANED AND RESEATED LEFT TANK HI-Z AND LO-Z CONNECTORS, NO HELP. REMOVED AND REPLACED RT DEUSDR HALA0700524Brake Assy · fireNR 6 TIRE AND WHEEL AND TIRE CAUGHT FIRE AFTER PARKING. REMOVED NR 6 TIRE FOUND EXCESSIVE GREASE ON THE AXLE. REPLACED NR 5 AND NR 6 TIRE PER AMM 32-45-01 INSPECTED AXLE AND BRAKE. LATER REPLACED NR 6 BRAKE AND PERFORMED AXLE OVER TEMPERATURE INSPECTION PRESDR HALA0700522Relay · malfunctionedETOPS SIGNIFICANT SYSTEM, AT 3+30 IN CRUISE LEFT FORWARD FUEL BOOST PUMP CIRCIUT BREAKER TRIPPED. REPLACED K-00188 LEFT FWD BOOST PUMP RELAY PER FIM767 28-22-00. GRND OPS CK OK.
SDR HALA0700515Apu · shutdownETOPS SIGNIFICANT SYSTEM, APU SHUT DOWN ON TAXI IN, PER FIM 49-11-01. BITE ECU NO FAULTS OPS CK GOOD APU OK TO CONTINUE.
SDR HALA0700516Apu · unknownETOPS SIGNIFICANT SYSTEM, APU FAILED TO START. FAULT LGT ILLUM AND EICAS MSG APU FAULT DISPLAYED. BITE CK ECU, NO FAULTS NOTED. CHECKED APU OIL QTY OK. STARTED APU ON GRD 2X, NORMAL STARTS OK FOR SERVICE.
SDR HALA0700507Unknown · unknownETOPS SIGNIFICANT SYSTEM, LEFT AND RIGHT ENGINES ARE OUT OF SYNC DURING CLIMB AND DESCENT. RIGHT ENGINE IS 1 PERCENT HIGHER THAN LEFT ENGINE. PER HAL ENGINEERING PERF DATA ALL NORMAL ACCOMP BITE CK, NO DEFECTS NOTED. TELEX SVC TO GENERATE TSI TO MONITOR. RSDR HALA0700501Connector · dirtyETOPS SIGNIFICANT SYSTEM, ATTITUDE INDICATION OF STANDBY ATTITUDE INDICATION IS ABNORMAL IN PITCH ROLL GYRO FLAG IS RETRACTED. CLEANED CONNECTORS ON STANDBY ATT IND GRND CHK NML, IAW 34-20-00.SDR HALA0700500Indicator · failedETOPS SIGNIFICANT SYSTEM, CAPT A/S INDICATOR FAILED ON FINAL APPROACH. REPLACED CAPT A/S IND OPS CHECK OK PER MM 34-13-01.
SDR HALA0700502Apu · malfunctionedETOPS SIGNIFICANT SYSTEM, APU FAILED TO START. FAULT LIGHT ILLUM AND EICAS MSG APU FAULT DISP ADDITIONAL START ATTEMPTS UNSUCCESSFUL. PERFORM BIT CHECK ON ECU. NO FAULTS NOTED. RUN APU OP CHECK NORMAL. NO DEFECTS NOTED. PER FIM 49-11-00.
SDR HALA0700498Battery Pack · dischargedEMERGENCY FLOOR TRACK LIGHT INOP ROW 20 - 29. REPLACED BATTERY PACK PER MM 33-51-07-022-003-002. FLOOR TRACK LIGHTING ROWS 20-29 LEFT OPS CKS NORMAL. ALL FLOOR "E" PATH LIGHTING OP CKS NORMAL.SDR HALA0700496Electronic Unit · malfunctionedETOPS SIGNIFICANT SYSTEM , FUEL QUANTITY MESSAGE DISPLAYED ON EICAS FUEL QTY BITE MAINT MESSAGE. REMOVED AND REPLACED DENSIOMETER ELECTRONICS UNIT PER AMM28-41-03. OPS AND SECURITY CK AND BITE CK OK.SDR HALA0700491Engine · oil consumptionETOPS SIGNIFICANT SYSTEM, ON ETOPS2 CHECK, NR 1 ENG WAS SERVICED W/4 PTS OF ENG OIL. INSPECTED NR 1 ENG NO LEAKS NOTED. A/C OK FOR SERVICE. CONSUMPTION W/I LIMITS, CONFERRED W/MOC.SDR HALA0700488Light · inoperativeEMERGENCY FLOOR TRACK LIGHTING INOP FROM 20HJ-29HJ. REPLACED CONNECTOR STRIP AT 29HJ, OPS CK NML.SDR HALA0700477Pseu · malfunctioned"BTB" ON TAXI OUT, GOT LEADING EDGE FLAP ASSEMBLY LIGHT. TRIED TO RETRACT BACK UP BUT GOT STUCK IN EXTENDED POSITION. BITE CHECKED FSEU-MESS NR 27-81-02 BITE PSEU CARD FAULT. REMOVED AND REPLACED PSEU PER M/M 32-09-04 OPS CHECK GOOD.SDR HALA0700475Coupler · damagedAIR TURN BACK ETOPS SIGNIFICANT SYSTEM UNABLE TO TRANSMIT ON BOTH HF RADIOS. REPLACED NR 2 HF COUPLER PER AMM 23-11-01-024-001 AND 23-11-01-424-008.SDR HALA0700472Coupler · damagedETOPS SIGNIFICANT SYSTEM NR 1 HF WOULD NOT INITIALIZE. REPLACED NR 1 HF COUPLER UNIT PER AMM 23-11-61.SDR HALA0700470Doubler · crackedNR 1 ENGINE NACELLE LOWER PAN DOUBLER AT NAC STA 352 CRACKED. REPLACED DOUBLER PER SRM 51-40-02 AND DRAWING 313T3355.SDR HALA0700465Exciter · inoperativeETOPS SIGNIFICANT SYSTEM: AFTER LANDING APU WOULD NOT START. REMOVED AND REPLACED IGNITION UNIT PER AMM 49-41-03.SDR HALA0700467Seat Track · corrodedSEAT TRACK CORROSION BEYOND SRM LIMITS RIGHT BODY LINE 88.5 STATION 1098 TO 1197+11. REPLACED TRACK PER SRM 51-40-02.SDR HALA0700462Support · crackedSEAL SUPPORT CRACKED ON THE RIGHT MLG SUPPORT BEAM JUST I/B OF RT MLG. REPLACED SEAL SUPPORT PER SRM 51-40-02.SDR HALA0700464Bracket · crackedCRACK ON "L" SECTION BRACKET LEFT ENGINE NACELLE STRUT HYDRAULIC COMPARTMENT FORWARD LOWER CORNER. REPLACED ANGLE BRACKET PER SRM 51-40-06.SDR HALA0700463Seat Track · corrodedLEVEL 2 CORROSION ON SEAT TRACK RBL 88.5 STATION 650 TO 654+44. REPLACED SEAT TRACK PER SRM 51-40-02.SDR HALA0700480Seat Track · corrodedSEAT TRACKS CORRODED IN SECTION 46 RBL 88.5, STA 1102 THRU 1439. REPLACED SEAT TRACK FROM STA 1102 TO STA 1439 RBL 88.5 AND RBL 11, STA 1197+37.SDR HALA0700466Spar · corrodedLEVEL 1 CORROSION ON FASTENERS ON LEFT HORIZONTAL STABLIZER REAR SPAR OUTBOARD END. REMOVED CORROSION PER SRM 51-10-02 AND TREATED PER SRM 51-20-01.SDR HALA0700461Seat Track · corrodedLEVEL 2 CORROSION SEAT TRACK AT LBL88.5 STATION 955-958 CORROSION BLEND OUT BEYOND SRM LIMITS. REMOVED DAMAGED SEAT TRACK IAW SRM 53-00-52 FIG 201 REPAIR 3 FROM STATION 922-989.SDR HALA0700482Seat Track · corrodedCORROSION AROUND SEAT TRACK LBL 11, STATION 656+21 TO STATION 656+32. REPLACE SEAT TRACK AT LBL 11, STATION 656+21 TO STATION 656+32.SDR HALA070071Seat Track · corrodedLEVEL 1 CORROSION ON SEAT TRACK AT RBL 11 STAT 654+13 TO 654+18. REMOVED CORROSION IAW 767 SRM 51-10-02 WITHIN LIMITS OF SRM 53-00-52/101.SDR HALA0700468Bracket · corrodedANGLE BRACKET HAS CORROSION AT STATION 1480 LBL 71 BELOW AFT LEFT LAV DOOR THRESHOLD. REPLACED BRACKET PER DRAWING 146T5705 AND SRM 51-40-06.SDR HALA0700483Seat Track · corrodedCORROSION FOUND AT 3S 654+120 LBL 22. SEAT TRACK SECTION REPLACED IAW SRM 51-40-02.SDR HALA0700481Seat Track · corrodedCORROSION AROUND SEAT TRACK ATTACH FLANGE AT STA 654 + 88 TO 118. REPLACED SEAT TRACK.SDR HALA0700478Seat Track · corrodedSEAT TRACK CORROSION BEYOND SRM LIMITS, SECTION 43, AT FS 654+56 THRU 654+66, LBL 20. REPAIR BY SEAT TRACK REPLACEMENT STA 632 THRU 654+66, LBL 20, IAW SRM 1.40.02.SDR HALA0700474Seat Track · corrodedLEVEL 2 CORROSION SECTION 43 SEAT TRACK CORROSION BEYOND SRM LIMITS AT STA 654+56 THRU 654+66 RBL 20. REPLACED SEAT TRACK PER SRM 51-40-02.SDR HALA0700479Seat Track · corrodedSEAT TRACK CORROSION BEYOND SRM LIMITS, SECTION 43, AT FS 534 THRU FS 650 RBL 88.5. REPAIR BY REPLACEMENT OF SEAT TRACK, FS 530 THRU FS 650 AT RBL 88.5 IAW SRM 53-00-52 REPAIR 3.SDR HALA0700459Lamp · inoperativeNOSE GEAR (DOWN) LIGHT INOP. RELAMPED DOWN NOSE GEAR INDICATION LIGHT. OPS CHECK OK. OK FOR SERVICE.SDR HALA0700469Seat Track · corrodedSEAT TRACK CORRODED BEYOND SRM LIMITS AT STN 1208 TO 1428 RBL 88.5. REPLACED SEAT TRACK IAW 767 SRM 51-40-02.SDR HALA0700458Turbine Blades · damagedETOPS SIGNIFICANT SYSTEM, DURING BOROSCOPE INSP LOOKING THROUGH AP-11 ACCESS. PORT FOUND 2 STAGE HIGH STAGE PRESSURE TURBINE BLADE DAMAGE ON NR 2 ENG. ACCOMPLISHED ENGINE INSTALLATION IAW HAL M275-767 NR 2 ENGINE. OPS AND LEAK CHECK GOOD. OK FOR SERVICE.
Back to Boeing 767-33A